OpenCores

SPI Master/Slave Interface

Issue List
MISO top-bit preload #9
Closed jdoin opened this issue over 12 years ago
jdoin commented over 12 years ago

The spi_slave.vhd has a MUX at the MISO output that preloads the top bit of the shifter before any spi clock. BUG: the mux will glitch when CPHA='1' at the first clock edge.

jdoin was assigned over 12 years ago
jdoin commented over 12 years ago

The glitch was due to using SSEL as the MUX selector, and when SSEL went LOW miso was updated at the first clock edge, the wrong edge for CPHA='1'.<br/> <br/> At the scope screen below, the 1st word transferred is 0x51.<br/> We can see the miso preload to '0', and the update to '1' taking place at the correct clock edge:<br/><br/> <img src="usercontent,img,1314589018" alt="slave_top_bit_preload" title="slave miso preload" /> <br/>

jdoin closed this over 12 years ago

Assignee
jdoin
Labels
Bug