TIP bit not set when generating STOP condition #37
Closed shuckc opened this issue about 11 years ago
shuckc commented about 11 years ago

I noticed in my test bench that 'tip' bit is not set when issuing a STOP command, only during read/write commands. This might give the impression the bus is free when it is busy.

I fixed this by changing tip <= (rd | wr); to: tip <= (rd | wr | sto);

In the top level class. It can take hundreds of cycles for the tip bit to be cleared by 'done' depending on the pre-scaler value.

shuckc commented about 11 years ago

The comment parser ate my verilog example. I changed

<pre> tip <= (rd | wr); </pre>

to:

<pre> tip <= (rd | wr | sto); </pre>
shuckc commented about 11 years ago

I changed: tip <= (rd | wr); to:

  tip      &lt;= (rd | wr | sto);
shuckc commented about 11 years ago

Withdrawn - polling the 'busy' bit in status register is sufficient for detecting end of stop.

What confused me was the testing of 'tip' after stop condition in tst_bench_top.v lines 440-444. This should be polling busy bit q6.

rherveille commented about 11 years ago

As you already noted; TIP (Transfer In Progress) indicates a read/write transfer. When a master owns the i2c bus, the BUSY bit is asserted.

rherveille closed this about 11 years ago
uecasm commented over 6 years ago

FWIW, having TIP support STOP condition checks is probably the better solution -- in a multi-master scenario polling BUSY is not correct because as soon as you release the bus but before you poll BUSY some other master might start a transfer, which will activate BUSY again even though your STOP is completed. You could be stuck like this indefinitely if the other masters are chatty.