OpenCores
URL https://opencores.org/ocsvn/zipcpu/zipcpu/trunk

Subversion Repositories zipcpu

Compare Revisions

  • This comparison shows the changes necessary to convert path
    /zipcpu
    from Rev 198 to Rev 199
    Reverse comparison

Rev 198 → Rev 199

/trunk/doc/spec.pdf Cannot display: file marked as a binary type. svn:mime-type = application/octet-stream
/trunk/doc/src/spec.tex
2,10 → 2,10
%%
%% Filename: spec.tex
%%
%% Project: Zip CPU -- a small, lightweight, RISC CPU soft core
%% Project: ZipCPU -- a small, lightweight, RISC CPU soft core
%%
%% Purpose: This LaTeX file contains all of the documentation/description
%% currently provided with this Zip CPU soft core. It supersedes
%% currently provided with this ZipCPU soft core. It supersedes
%% any information about the instruction set or CPUs found
%% elsewhere. It's not nearly as interesting, though, as the PDF
%% file it creates, so I'd recommend reading that before diving
66,7 → 66,7
% environment, very little optimization by hand ...
%
%
% The FPGA's achilles heel: Reconfigurability. It is very difficult, although
% The FPGA's Achille's heel: Reconfigurability. It is very difficult, although
% I'm sure major vendors will tell you not impossible, to reconfigure an FPGA
% based upon the need to process time-sensitive data. If you need one of two
% algorithms, both which will fit on the FPGA individually but not together,
83,11 → 83,11
\usepackage{import}
\usepackage{bytefield} % Install via apt-get install texlive-science
% \graphicspath{{../gfx}}
\project{Zip CPU}
\project{ZipCPU}
\title{Specification}
\author{Dan Gisselquist, Ph.D.}
\email{dgisselq (at) opencores.org}
\revision{Rev.~0.91}
\revision{Rev.~1.0}
\definecolor{webred}{rgb}{0.5,0,0}
\definecolor{webgreen}{rgb}{0,0.4,0}
\hypersetup{
95,7 → 95,7
pdfpagelabels,
hypertexnames,
pdfauthor={Dan Gisselquist},
pdfsubject={Zip CPU},
pdfsubject={ZipCPU},
anchorcolor= black,
colorlinks = true,
linkcolor = webred,
118,13 → 118,16
for more details.
 
You should have received a copy of the GNU General Public License along
with this program. If not, see \hbox{<http://www.gnu.org/licenses/>} for a
copy.
with this program. If not, see \hbox{$<$http://www.gnu.org/licenses/$>$} for
a copy.
\end{license}
\begin{revisionhistory}
0.9 & 4/20/2016 & Gisselquist & Modified ISA: LDIHI replaced with MPY, MPYU and MPYS replaced with MPYUHI, and MPYSHI respectively. LOCK instruction now
permits an intermediate ALU operation. \\\hline
0.91& 7/16/2016 & Gisselquist & :escribed three more CC bits\\\hline
1.0 & 11/4/2016 & Gisselquist & Major rewrite,
includes compiler info\\\hline
0.91& 7/16/2016 & Gisselquist & Described three more CC bits\\\hline
0.9 & 4/20/2016 & Gisselquist & Modified ISA: LDIHI replaced with MPY,
MPYU and MPYS replaced with MPYUHI, and MPYSHI respectively. LOCK
instruction now permits an intermediate ALU operation. \\\hline
0.8 & 1/28/2016 & Gisselquist & Reduced complexity early branching \\\hline
0.7 & 12/22/2015 & Gisselquist & New Instruction Set Architecture \\\hline
0.6 & 11/17/2015 & Gisselquist & Added graphics to illustrate pipeline discussion.\\\hline
140,38 → 143,39
\listoffigures
\listoftables
\begin{preface}
Many people have asked me why I am building the Zip CPU. ARM processors are
good and effective. Xilinx makes and markets Microblaze, Altera Nios, and both
have better toolsets than the Zip CPU will ever have. OpenRISC is also
Many people have asked me why I am building the ZipCPU. ARM processors are
good and effective. Xilinx makes and markets Microblaze, Altera Nios, and both
have better toolsets than the ZipCPU will ever have. OpenRISC is also
available, RISC--V may be replacing it. Why build a new processor?
 
The easiest, most obvious answer is the simple one: Because I can.
 
There's more to it, though. There's a lot that I would like to do with a
processor, and I want to be able to do it in a vendor independent fashion.
There's more to it though. There's a lot of things that I would like to do with
a processor, and I want to be able to do them in a vendor independent fashion.
First, I would like to be able to place this processor inside an FPGA. Without
paying royalties, ARM is out of the question. I would then like to be able to
generate Verilog code, both for the processor and the system it sits within,
that can run equivalently on both Xilinx and Altera chips, and that can be
easily ported from one manufacturer's chipsets to another. Even more, before
purchasing a chip or a board, I would like to know that my soft core works. I
would like to build a test bench to test components with, and Verilator is my
chosen test bench. This forces me to use all Verilog, and it prevents me from
using any proprietary cores. For this reason, Microblaze and Nios are out of
the question.
that can run equivalently on both Xilinx, Altera, and Lattice chips, and that
can be easily ported from one manufacturer's chipsets to another. Even more,
before purchasing a chip or a board, I would like to know that my soft core
works. I would like to build a test bench to test components with, and
Verilator is my chosen test bench. This forces me to use all Verilog, and it
prevents me from using any proprietary cores. For this reason, Microblaze and
Nios are out of the question.
 
Why not OpenRISC? That's a hard question. The OpenRISC team has done some
wonderful work on an amazing processor, and I'll have to admit that I am
envious of what they've accomplished. I would like to port binutils to the
Zip CPU, as I would like to port GCC and GDB. They are way ahead of me. The
OpenRISC processor, however, is complex and hefty at about 4,500 LUTs. It has
a lot of features of modern CPUs within it that ... well, let's just say it's
not the little guy on the block. The Zip CPU is lighter weight, costing only
about 2,300 LUTs with no peripherals, and 3,200 LUTs with some very basic
peripherals.
Why not OpenRISC? Because the ZipCPU has different goals. OpenRISC is designed
to be a full featured CPU. The ZipCPU was designed to be a simple, resource
friendly, CPU. The result is that it is easy to get a ZipCPU program running
on bare hardware for a special purpose application--such as what FPGAs were
designed for, but getting a full featured
Linux distribution running on the ZipCPU may just be beyond my grasp. Further,
the OpenRISC ISA is very complex, defining over 200~instructions--even though
it has never been fully implemented. The ZipCPU on the other hand has only
a small handful of instructions, and all but the Floating Point instructions
have already been fully implemented.
 
My final reason is that I'm building the Zip CPU as a learning experience. The
Zip CPU has allowed me to learn a lot about how CPUs work on a very micro
My final reason is that I'm building the ZipCPU as a learning experience. The
ZipCPU has allowed me to learn a lot about how CPUs work on a very micro
level. For the first time, I am beginning to understand many of the Computer
Architecture lessons from years ago.
 
184,20 → 188,26
\pagenumbering{arabic}
\setcounter{page}{1}
 
 
The original goal of the Zip CPU was to be a very simple CPU. You might
think of it as a poor man's alternative to the OpenRISC architecture.
The goal of the ZipCPU was to be a very simple CPU. You might think of it as
a poor man's alternative to the OpenRISC architecture. You might also think of
it as an Open Source microcontroller.
For this reason, all instructions have been designed to be as simple as
possible, and the base instructions are all designed to be executed in one
instruction cycle per instruction, barring pipeline stalls. Indeed, even the
bus has been simplified to a constant 32-bit width, with no option for more
or less. This has resulted in the choice to drop push and pop instructions,
pre-increment and post-decrement addressing modes, and more.
instruction cycle per instruction, barring pipeline stalls.\footnote{The
exceptions to this rule are the multiply, divide, and load/store instructions.
Once the floating point unit is built, I anticipate these will also be
exceptions to this rule.} Indeed, even the bus has been simplified to a
constant 32-bit width, with no option for more or less. This has resulted in
the choice to drop push and pop instructions, pre-increment and post-decrement
addressing modes, the integrated memory management unit (MMU), and
more.\footnote{A not--so integrated MMU is currently under development.}
 
For those who like buzz words, the Zip CPU is:
For those who like buzz words, the ZipCPU is:
\begin{itemize}
\item A 32-bit CPU: All registers are 32-bits, addresses are 32-bits,
instructions are 32-bits wide, etc.
instructions are 32-bits wide, etc. Indeed, the ``byte size''
for this processor, as per the C--language definition of a
``byte'' being the smallest addressable unit, is 32--bits.
\item A RISC CPU. There is no microcode for executing instructions. All
instructions are designed to be completed in one clock cycle.
\item A Load/Store architecture. (Only load and store instructions
204,43 → 214,54
can access memory.)
\item Wishbone compliant. All peripherals are accessed just like
memory across this bus.
\item A Von-Neumann architecture. (The instructions and data share a
common bus.)
\item A Von-Neumann architecture. The instructions and data share a
common bus.
\item A pipelined architecture, having stages for {\bf Prefetch},
{\bf Decode}, {\bf Read-Operand}, a
combined stage containing the {\bf ALU},
{\bf Memory}, {\bf Divide}, and {\bf Floating Point}
units, and then the final {\bf Write-back} stage.
{\bf Decode}, {\bf Read-Operand}, a combined stage containing
the {\bf ALU}, {\bf Memory}, {\bf Divide}, and {\bf Floating Point}
units, and then the final {\bf Write-back} stage.
See Fig.~\ref{fig:cpu}
\begin{figure}\begin{center}
\includegraphics[width=3.5in]{../gfx/cpu.eps}
\caption{Zip CPU internal pipeline architecture}\label{fig:cpu}
\caption{ZipCPU internal pipeline architecture}\label{fig:cpu}
\end{center}\end{figure}
for a diagram of this structure.
\item Completely open source, licensed under the GPL.\footnote{Should you
need a copy of the Zip CPU licensed under other terms, please
need a copy of the ZipCPU licensed under other terms, please
contact me.}
\end{itemize}
 
The Zip CPU also has one very unique feature: the ability to do pipelined loads
The ZipCPU also has one very unique feature: the ability to do pipelined loads
and stores. This allows the CPU to access on-chip memory at one access per
clock, minus a stall for the initial access.
clock, minus any stalls for the initial access.
 
\section{Characteristics of a SwiC}
 
Here, we shall define a soft core internal to an FPGA as a ``System within a
Chip,'' or a SwiC. SwiCs have some very unique properties internal to them
that have influenced the design of the Zip CPU. Among these are the bus,
memory, and available peripherals.
This section might also be called {\em the ZipCPU philosophy}. It discusses
the basis for the ZipCPU design decisions, and why a low logic count CPU
is or can be a good thing.
 
Most other approaches to soft core CPU's employ a Harvard architecture.
Many other FPGA processors have been defined to be good Systems on a Chip, or
SoC's. The entire goal of such designs, then, is to provide an interface
to the processor and its external environment. This is not the case with the
ZipCPU. Instead, we shall define a new concept, that of a soft core internal to
an FPGA, as a ``System within a Chip,'' or a SwiC. SwiCs have some very
unique properties internal to them that have influenced the design of the
ZipCPU. Among these are the bus, memory, and available peripherals.
 
Many other approaches to soft core CPU's employ a Harvard architecture.
This allows these other CPU's to have two separate bus structures: one for the
program fetch, and the other for the memory. The Zip CPU is fairly unique in
its approach because it uses a von Neumann architecture. This was done for
simplicity. By using a von Neumann architecture, only one bus needs to be
implemented within any FPGA. This helps to minimize real-estate, while
maintaining a high clock speed. The disadvantage is that it can severely
degrade the overall instructions per clock count.
program fetch, and the other for the memory. Indeed, Xilinx's proprietary
Microblaze processor
goes so far as to support four busses: two for cacheable memory, and two for
peripherals, with each of those split between instructions and data. The
ZipCPU on the other hand is fairly unique in its approach because it uses a
Von Neumann architecture, requiring only one bus within any FPGA. This
structure was chosen for its simplicity. Having only the one bus helps to
minimize real-estate, logic, and the number of wires that need to be passed
back and forth, while maintaining a high clock speed. The disadvantage is
that both prefetch and memory access units need to contend for time on the
same bus.
 
Soft core's within an FPGA have an additional characteristic regarding
memory access: it is slow. While memory on chip may be accessed at a single
256,14 → 277,17
complicated.
 
As may be noticed from the above discussion about memory speed, a second
characteristic of memory is that all memory accesses may be pipelined, and
that pipelined memory access is faster than non--pipelined access. Therefore,
a SwiC soft core should support pipelined operations, but it should also
allow a higher priority subsystem to get access to the bus (no starvation).
characteristic of memory is sequential memory accesses may be optimized for
minimal delays (pipelined), and that pipelined memory access is faster than
non--pipelined access. Therefore, a SwiC soft core should support pipelined
operations, but it should also allow a higher priority subsystem to get access
to the bus (no starvation).
 
As a further characteristic of SwiC memory options, on-chip cache's are
expensive. If you want to have a minimum of logic, cache logic may not be
the highest on the priority list.
the highest on the priority list. Any SwiC capable processor must be able
to either be built without caches, or to scale up or down the logic required
by any cache.
 
In sum, memory is slow. While one processor on one FPGA may be able to fill
its pipeline, the same processor on another FPGA may struggle to get more than
274,259 → 298,314
Specifically, FPGA's are highly reconfigurable. Soft peripherals can easily
be created on chip to support the SwiC if necessary. As an example, a simple
30-bit peripheral could easily support reversing 30-bit numbers: a read from
the peripheral returns it's bit--reversed address. This is cheap within an
the peripheral returns its bit--reversed address. This is cheap within an
FPGA, but expensive in instructions. Reading from another 16--bit peripheral
might calculate a sine function, where the 16--bit address internal to the
peripheral was the angle of the sine wave.
 
Indeed, anything that must be done fast within an FPGA is likely to already
be done--elsewhere in the fabric. This leaves the CPU with the simple role
of solely handling sequential tasks that need a lot of state.
be done--elsewhere in the fabric. Further, the application designer gets to
choose what tasks are so important they need fabric dedicated to them, and which
ones can be done more slowly in a CPU. This leaves the CPU with the simple role
of solely handling sequential tasks, and tasks that need a lot of state.
 
This means that the SwiC needs to live within a very unique environment,
separate and different from the traditional SoC. That isn't to say that a
SwiC cannot be turned into a SoC, just that this SwiC has not been designed
for that purpose.
for that purpose. Indeed, some of the best examples of the ZipCPU are
System on a Chip examples.
 
\section{Lessons Learned}
\section{Scope}\label{sec:limits}
 
Now, however, that I've worked on the Zip CPU for a while, it is not nearly
as simple as I originally hoped. Worse, I've had to adjust to create
capabilities that I was never expecting to need. These include:
\begin{itemize}
\item {\bf External Debug:} Once placed upon an FPGA, some external means is
still necessary to debug this CPU. That means that there needs to be
an external register that can control the CPU: reset it, halt it, step
it, and tell whether it is running or not. My chosen interface
includes a second register similar to this control register. This
second register allows the external controller or debugger to examine
registers internal to the CPU.
The ZipCPU is itself nothing more than a CPU that can be placed within a
larger design. It is not a System on a Chip, but it can be used to create
a system on a chip. As a result, this document will not discuss more than a
small handful of CPU--related peripherals, as the actual peripherals used
within a design will vary from one design to the next. Further, because
control access will vary from one environment to the next, this document will
not discuss any host control programs, leaving those to be discussed and defined
together with the environments the ZipCPU is placed within.
 
\item {\bf Internal Debug:} Being able to run a debugger from within
a user process requires an ability to step a user process from
within a debugger. It also requires a break instruction that can
be substituted for any other instruction, and substituted back.
The break is actually difficult: the break instruction cannot be
allowed to execute. That way, upon a break, the debugger should
be able to jump back into the user process to step the instruction
that would've been at the break point initially, and then to
replace the break after passing it.
\chapter{CPU Architecture}\label{chap:arch}
 
Incidentally, this break messes with the prefetch cache and the
pipeline: if you change an instruction partially through the pipeline,
the whole pipeline needs to be cleansed. Likewise if you change
an instruction in memory, you need to make sure the cache is reloaded
with the new instruction.
This chapter describes the general architecture of the ZipCPU. It first
discusses
the configuration options to the CPU and then breaks into two threads. These
last two threads are a discussion of the internals of the ZipCPU, such as its
instruction set architecture and the details and consequences of it, and then
the external architecture describing how the ZipCPU fits into the systems
surrounding it, and what those systems must do to support it. Specifically,
the external architecture section will discuss both the ZipSystem, the
peripherals provided by it, as well as the debug interface.
 
\item {\bf Prefetch Cache:} My original implementation, {\tt prefetch}, had
a very simple prefetch stage. Any time the PC changed the prefetch
would go and fetch the new instruction. While this was perhaps this
simplest approach, it cost roughly five clocks for every instruction.
This was deemed unacceptable, as I wanted a CPU that could execute
instructions in one cycle.
\section{Build Options/defines}\label{ssec:build-options}
 
My second implementation, {\tt pipefetch}, attempted to make the most
use of pipelined memory. When a new CPU address was issued, it would
start reading
memory in a pipelined fashion, and issuing instructions as soon as they
were ready. This cache was a sliding window in memory. This suffered
from some difficult performance problems, though. If the CPU was
alternating between two diverse sections of code, both could never be
in the cache at the same time--causing lots of cache misses. Further,
the extra logic to implement this window cost an extra clock cycle
in the cache implementation, slowing down branches.
One problem with a simple goal such as being light on logic, is that some
architectures have some needs, others have other needs. What is light logic
in some architectures might consume all the available logic in others.
As an example, the CMod~S6 board built by Digilent uses a very spare Xilinx
Spartan~6 LX4 FPGA. This FPGA doesn't have enough look up tables (LUTs) to
support pipelined mode, whereas another project running on a XuLA2 LX25 board
made by Xess, having a Spartan~6 LX25 on board, has more than enough logic
to support a pipelined mode. Very quickly it becomes clear that LUTs can be
traded for performance.
 
The Zip CPU now has a third cache implementation, {\tt pfcache}. This
new implementation takes only a single cycle per access, but costs a
full cache line miss on any miss. While configurable, a full cache
line miss might mean that the CPU needs to read 256~instructions from
memory before it can execute the first one of them.
To make this possible, the ZipCPU has both a configuration file as well as a
set of parameters that it can be built with. Often, those parameters can
override the configuration file, but not all configuration file changes can
be overridden. Several options are available within the configuration file,
such as making the Zip CPU pipelined or not, able to handle a faster clock
with more stalls or a slower clock with no stalls, etc.
 
\item {\bf Operating System:} In order to support an operating system,
interrupts and so forth, the CPU needs to support supervisor and
user modes, as well as a means of switching between them. For example,
the user needs a means of executing a system call. This is the
purpose of the {\bf `trap'} instruction. This instruction needs to
place the CPU into supervisor mode (here equivalent to disabling
interrupts), as well as handing it a parameter such as identifying
which O/S function was called.
The {\tt cpudefs.v} file encapsulates those control options. It contains a
series of {\tt `define} statements that can either be commented or left
active. If active, the option is considered to be in effect. The number of
LUTs the Zip CPU uses varies dramatically with the options defined in this file.
This section will outline the various configuration options captured by this
file.
 
My initial approach to building a trap instruction was to create an external
peripheral which, when written to, would generate an interrupt and could
return the last value written to it. In practice, this approach didn't work
at all: the CPU executed two instructions while waiting for the
trap interrupt to take place. Since then, I've decided to keep the rest of
the CC register for that purpose so that a write to the CC register, with the
GIE bit cleared, could be used to execute a trap. This has other problems,
though, primarily in the limitation of the uses of the CC register. In
particular, the CC register is the best place to put CPU state information and
to ``announce'' special CPU features (floating point, etc). So the trap
instruction still switches to interrupt mode, but the CC register is not
nearly as useful for telling the supervisor mode processor what trap is being
executed.
The first couple of options control the Zip CPU instruction set, and how
it handles various instructions within the set:
 
Modern timesharing systems also depend upon a {\bf Timer} interrupt
to handle task swapping. For the Zip CPU, this interrupt is handled
external to the CPU as part of the CPU System, found in {\tt zipsystem.v}.
The timer module itself is found in {\tt ziptimer.v}.
 
\item {\bf Bus Errors:} My original implementation had no logic to handle
what would happen if the CPU attempted to read or write a non-existent
memory address. This changed after I needed to troubleshoot a failure
caused by a subroutine return to a non-existent address.
{\tt OPT\_MULTIPLY} controls whether or not the multiply is built and included
in the ALU by default, and if it is which of several multiply options is
selected. Unlike many of the defines that follow within {\tt cpudefs.v} that
are either defined or not, this option requires a value. A value of zero means
no multiply support, whereas a value of one, two, or three, means that a
multiply will be included that takes one, two, or three clock cycles to
complete. The option, however, only controls the default value that the
{\tt IMPLEMENT\_MPY} parameter to the CPU, having the same interpretation, is
given. Because this is just the default value, it can easily be overridden
upon instantiation. If the {\tt IMPLEMENT\_MPY} parameter is set to zero,
then any attempt to execute a multiply instruction will cause an illegal
instruction exception.
 
My next problem bus problem was caused by a misbehaving peripheral.
Whenever the CPU attempted to read from or write to this peripheral,
the peripheral would take control of the wishbone bus and not return
it. For example, it might never return an {\tt ACK} to signal
the end of the bus transaction. This led to the implementation of
a wishbone bus watchdog that would create a bus error if any particular
bus action didn't complete in a timely fashion.
{\tt OPT\_DIVIDE} controls whether or not the divide instruction is built and
included into the ZipCPU by default. Set this option and the
{\tt IMPLEMENT\_DIVIDE} parameter will have a default value of one, meaning that
unless it is overridden with zero, the divide unit will be included. If the
divide is not included, then any attempt to use a divide instruction will
create an illegal instruction exception that will send the CPU into supervisor
mode.
 
\item {\bf Pipeline Stalls:} My original plan was to not support pipeline
stalls at all, but rather to require the compiler to properly schedule
all instructions so that stalls would never be necessary. After trying
to build such an architecture, I gave up, having learned some things:
{\tt OPT\_IMPLEMENT\_FPU} will (one day) control whether or not the floating
point unit (once I have one) is built and included into the ZipCPU by default.
This option sets the {\tt IMPLEMENT\_FPU} parameter to one, so alternatively
it can be set and adjusted upon instantiation. If the floating point unit is
not included then, as with the multiply and divide, any floating point
instruction will result in an illegal instruction exception that will send the
CPU into supervisor mode.
 
First, and ideal pipeline might look something like
Fig.~\ref{fig:ideal-pipeline}.
\begin{figure}
\begin{center}
\includegraphics[width=4in]{../gfx/fullpline.eps}
\caption{An Ideal Pipeline: One instruction per clock cycle}\label{fig:ideal-pipeline}
\end{center}\end{figure}
Notice that, in this figure, all the pipeline stages are complete and
full. Every instruction takes one clock and there are no delays.
However, as the discussion above pointed out, the memory associated
with a SwiC may not allow single clock access. It may be instead
that you can only read every two clocks. In that case, what shall
the pipeline look like? Should it look like
Fig.~\ref{fig:waiting-pipeline},
\begin{figure}\begin{center}
\includegraphics[width=4in]{../gfx/stuttra.eps}
\caption{Instructions wait for each other}\label{fig:waiting-pipeline}
\end{center}\end{figure}
where instructions are held back until the pipeline is full, or should
it look like Fig.~\ref{fig:independent-pipeline},
\begin{figure}\begin{center}
\includegraphics[width=4in]{../gfx/stuttrb.eps}
\caption{Instructions proceed independently}\label{fig:independent-pipeline}
\end{center}\end{figure}
where each instruction is allowed to move through the pipeline
independently? For better or worse, the Zip CPU allows instructions
to move through the pipeline independently.
{\tt OPT\_SINGLE\_FETCH} controls whether or not the prefetch has a cache, and
whether or not it can issue one instruction per clock. When set, the
prefetch has no cache, and only one instruction is fetched at any given time.
This effectively sets the CPU so that only one instruction is ever
in the pipeline at a time, and hence you may think of this as a ``no
pipeline'' option. However, since the pipeline uses so much area on the FPGA,
this is an important option to use in trimming down used logic if necessary.
Hence, it needs to be maintained for that purpose. Be aware, though, setting
this option will disable all pipelining, and therefore will drop your
performance by a factor of 8x or even more.
 
One approach to avoiding stalls is to use a branch delay slot,
such as is shown in Fig.~\ref{fig:brdelay}.
\begin{figure}\begin{center}
\includegraphics[width=4in]{../gfx/bdly.eps}
\caption{A typical branch delay slot approach}\label{fig:brdelay}
\end{center}\end{figure}
In this figure, instructions
{\tt BR} (a branch), {\tt BD} (a branch delay instruction),
are followed by instructions after the branch: {\tt IA}, {\tt IB}, etc.
Since it takes a processor a clock cycle to execute a branch, the
delay slot allows the processor to do something useful in that
branch. The problem the Zip CPU has with this approach is, what
happens when the pipeline looks like Fig.~\ref{fig:brbroken}?
\begin{figure}\begin{center}
\includegraphics[width=4in]{../gfx/bdbroken.eps}
\caption{The branch delay slot breaks with a slow memory}\label{fig:brbroken}
\end{center}\end{figure}
In this case, the branch delay slot never gets filled in the first
place, and so the pipeline squashes it before it gets executed.
If not that, then what happens when handling interrupts or
debug stepping: when has the CPU finished an instruction?
When the {\tt BR} instruction has finished, or must {\tt BD}
follow every {\tt BR}? and, again, what if the pipeline isn't
full?
These thoughts killed any hopes of doing delayed branching.
I recommend only defining or enabling this option if you {\em need} to,
such as if area is tight and speed isn't as important. Otherwise, leave the
option undefined since the pipelined options have a much better speed
performance.
 
So I switched to a model of discrete execution: Once an instruction
enters into either the ALU or memory unit, the instruction is
guaranteed to complete. If the logic recognizes a branch or a
condition that would render the instruction entering into this stage
possibly inappropriate (i.e. a conditional branch preceding a store
instruction for example), then the pipeline stalls for one cycle
until the conditional branch completes. Then, if it generates a new
PC address, the stages preceding are all wiped clean.
The next several options are pipeline optimization options. They make no
sense in a single instruction fetch mode, hence they are all disabled if
{\tt OPT\_SINGLE\_FETCH} is defined.
 
This model, however, generated too many pipeline stalls, so the
discrete execution model was modified to allow instructions to go
through the ALU unit and be canceled before writeback. This removed
the stall associated with ALU instructions before untaken branches.
{\tt OPT\_PIPELINED} is the natural result and opposite of using the single
instruction fetch unit. It is an internal parameter that doesn't need user
adjustment, but if you look through the {\tt cpudefs.v} file you may see
and notice it. If you have not set the {\tt OPT\_SINGLE\_FETCH} parameter,
{\tt cpudefs.v} will set the {\tt OPT\_PIPELINED} option. This is more for
readability than anything else, since {\tt OPT\_PIPELINED} makes more
intuitive readability sense than {\tt OPT\_SINGLE\_FETCH}. In other words,
define or comment out {\tt OPT\_SINGLE\_FETCH}, and let {\tt OPT\_PIPELINED} be
taken care of automatically.
 
The discrete execution model allows such things as sleeping, as
outlined in Fig.~\ref{fig:sleeping}.
\begin{figure}\begin{center}
\includegraphics[width=4in]{../gfx/sleep.eps}
\caption{How the CPU halts when sleeping}\label{fig:sleeping}
\end{center}\end{figure}
If the
CPU is put to ``sleep,'' the ALU and memory stages stall and back up
everything before them. Likewise, anything that has entered the ALU
or memory stage when the CPU is placed to sleep continues to completion.
To handle this logic, each pipeline stage has three control signals:
a valid signal, a stall signal, and a clock enable signal. In
general, a stage stalls if it's contents are valid and the next step
is stalled. This allows the pipeline to fill any time a later stage
stalls, as illustrated in Fig.~\ref{fig:stacking}.
\begin{figure}\begin{center}
\includegraphics[width=4in]{../gfx/stacking.eps}
\caption{Instructions can stack up behind a stalled instruction}\label{fig:stacking}
\end{center}\end{figure}
However, if a pipeline hazard is detected, a stage can stall in order
to prevent the previous from moving forward.
Assuming you have chosen not to define {\tt OPT\_SINGLE\_FETCH},
{\tt OPT\_TRADITIONAL\_PFCACHE} allows you to switch between one of two
prefetch cache modules. If enabled (recommended), a more traditional cache
will be implemented in the CPU. This more traditional cache reduces
the stall count tremendously over the alternative pipeline cache, and its
LUT usage is quite competitive. As there is little downside to defining
this option if pipelining is enabled, I would recommend including it.
 
This approach is also different from other pipeline approaches.
Instead of keeping the entire pipeline filled, each stage is treated
independently. Therefore, individual stages may move forward as long
as the subsequent stage is available, regardless of whether the stage
behind it is filled.
\end{itemize}
The alternative prefetch and cache, sometimes called the pipeline cache, tries
to read instructions ahead of where they are needed, while maintaining what it
has read in a cache. That cache is cleared anytime you jump outside of its
window, and it often competes with the CPU for access to the bus. These
two characteristics make this alternative bus often less than optimal.
 
With that introduction out of the way, let's move on to the instruction
set.
 
\chapter{CPU Architecture}\label{chap:arch}
{\tt OPT\_EARLY\_BRANCHING} is an attempt to execute a {\tt BRA} (branch or
jump) statement as early
in the pipeline as possible, to avoid as many pipeline stalls on a branch as
possible. As an example, if you have {\tt OPT\_TRADITIONAL\_PFCACHE} defined
as well, then branches within the cache will only cost a single stall cycle.
Indeed, using early branching, a {\tt BRA} instruction can be used as the
compiler's branch prediction optimizer: {\tt BRA}'s barely stall, while
branches on conditions will always suffer about 6~stall cycles. Setting
this option causes the parameter, {\tt EARLY\_BRANCHING}, to be set to one,
so it can be overridden upon instantiation.
 
The Zip CPU supports a set of two operand instructions, where the second operand
(always a register) is the result. The only exception is the store instruction,
where the first operand (always a register) is the source of the data to be
stored.
Given the performance benefits achieved by early branching, setting this flag
is highly recommended.
 
\section{Simplified Bus}
The bus architecture of the Zip CPU is that of a simplified WISHBONE bus.
It has been simplified in this fashion: all operations are 32--bit operations.
The bus is neither little endian nor big endian. For this reason, all words
are 32--bits. All instructions are also 32--bits wide. Everything has been
built around the 32--bit word.
{\tt OPT\_PIPELINED\_BUS\_ACCESS} controls whether or not {\tt LOD}/{\tt STO}
instructions can take advantage of the pipelined wishbone bus. To be
eligible, the operations to be pipelined must be adjacent, must be all
{\tt LOD}s or all {\tt STO}s, and the addresses must all use the same base
address register and either have identical immediate offsets, or immediate
offsets that increase by one for each instruction. Further, the
{\tt LOD}/{\tt STO} string of instructions must all have the same conditional
(if any). Currently, this approach and benefit is most effectively used
when saving registers to or restoring registers from the stack at the
beginning/end of a procedure, when using assembly optimized programs, or
when doing a context swap.
 
\section{Register Set}
The Zip CPU supports two sets of sixteen 32-bit registers, a supervisor
and a user set as shown in Fig.~\ref{fig:regset}.
I recommend setting this flag, for performance reasons, especially if your
wishbone bus implementation can handle pipelined bus accesses. The logic
impact of this setting is minimal, the performance impact can be significant.
 
{\tt OPT\_VLIW} includes within the instruction set the Very Long Instruction
Word packing, which packs up to two instructions within each instruction word.
Non--packed instructions will still execute as normal, this just enables the
decoding and running of packed instructions.
 
The two next options, {\tt INCLUDE\_DMA\_CONTROLLER} and
{\tt INCLUDE\_ACCOUNTING\_COUNTERS}
control whether the DMA controller is included in the ZipSystem, and
whether or not the eight accounting timers are also included. Set these to
include the respective peripherals, comment them out not to. These only
affect the ZipSystem implementation, and not any ZipBones implementations.
 
Finally, if you find yourself needing to debug the core and specifically needing
to get a trace from the core to find out why something specifically failed,
you may find it useful to define {\tt DEBUG\_SCOPE}. This will add a 32--bit
debug output from the core, as the last argument to the core, to the ZipSystem,
or even to ZipBones. The actual definition and composition of this debugging
bit--field changes from one implementation to the next, depending upon needs
and necessities, so please look at the code at the bottom of {\tt zipcpu.v}
for more details.
 
That ends our discussion of CPU options, but there remain several implementation
parameters that can be defined with the CPU as well. Some of these, such as
{\tt IMPLEMENT\_MPY}, {\tt IMPLEMENT\_DIVIDE}, {\tt IMPLEMENT\_FPU}, and
{\tt EARLY\_BRANCHING} have already been discussed. The remainder shall be
discussed quickly here.
 
The {\tt RESET\_ADDRESS} parameter controls what address the CPU attempts to
fetch its first instruction from upon any CPU reset. The default value is
not likely to be particularly useful, so overriding the default is recommended
for every implementation.
 
The {\tt ADDRESS\_WIDTH} parameter can be used to trim down the width of
addresses used by the CPU. For example, although the Wishbone Bus definition
used by the CPU has 32--address lines, particular implementations may have
fewer. By setting this value to the actual number of wires in the address
bus, some logic can be spared within the CPU. The default is a 32--bit wide
bus.
 
The {\tt LGICACHE} parameter specifies the log base two of the instruction
cache size. If no instruction cache is used, this option has no effect.
Otherwise it sets the size of the instruction cache to be
$2^{\mbox{\tiny\tt LGICACHE}}$ words. The traditional prefetch cache, if used,
will split this cache size into up to thirty two separate cache lines.
 
The {\tt IMPLEMENT\_LOCK} parameter controls whether or not the {\tt LOCK}
instruction is implemented. If set to zero, the {\tt LOCK} instruction will
cause an illegal instruction exception, otherwise it will be implemented if
pipelining is enabled.
 
Other parameters are defined within the ZipSystem parent module, and affect
the performance of the system as a whole.
 
The {\tt START\_HALTED} parameter, if set to non--zero, will cause the
CPU to be halted upon startup. This is useful for debugging, since it prevents
the CPU from doing anything without supervision. Of course, once all pieces
of your design are in place and proven, you'll probably want to set this to
zero.
 
The {\tt EXTERNAL\_INTERRUPTS} parameter controls the number of interrupt
wires coming into the CPU. This number must be between one and sixteen,
or if the performance counters are disabled, between one and twenty four.
 
\section{Internal Architecture}\label{sec:internals}
 
This section discusses the general architecture of the CPU itself, separated
from its environment. As such, it focuses on the instruction set layout
and how those instructions are implemented.
 
\subsection{Register Set}
 
Fundamental to the understanding of the ZipCPU is its register set, and the
performance model associated with it.
The ZipCPU register set contains two sets of sixteen 32-bit registers, a
supervisor and a user set as shown in Fig.~\ref{fig:regset}.
\begin{figure}\begin{center}
\includegraphics[width=3.5in]{../gfx/regset.eps}
\caption{Zip CPU Register File}\label{fig:regset}
\begin{tabular}{|c|c|c|c|c|}
\multicolumn{2}{c}{Supervisor Register Set} &
\multicolumn{1}{c}{} &
\multicolumn{2}{c}{User Register Set} \\
\multicolumn{2}{c}{\#'s 0-15} & \multicolumn{1}{c}{} &
\multicolumn{2}{c}{\#'s 16-31} \\\hline\hline
sR0(LR) & sR8 && uR0(LR) & uR8 \\\cline{1-2}\cline{4-5}
sR1 & sR9 && uR1 & uR9 \\\cline{1-2}\cline{4-5}
sR2 & sR10 && uR2 & uR10 \\\cline{1-2}\cline{4-5}
sR3 & sR11 && uR3 & uR11 \\\cline{1-2}\cline{4-5}
sR4 & sR12(FP)&& uR4& uR12(FP)\\\cline{1-2}\cline{4-5}
sR5 & sSP && uR5 & uSP \\\cline{1-2}\cline{4-5}
sR6 & sCC && uR6 & uCC \\\cline{1-2}\cline{4-5}
sR7 & sPC && uR7 & uPC \\\hline\hline
\multicolumn{2}{c}{Interrupts Disabled} &
\multicolumn{1}{c}{} &
\multicolumn{2}{c}{Interrupts Enabled} \\
\end{tabular}
\caption{ZipCPU Register File}\label{fig:regset}
\end{center}\end{figure}
The supervisor set is used in interrupt mode when interrupts are disabled,
whereas the user set is used otherwise. Of this register set, the Program
Counter (PC) is register 15, whereas the status register (SR) or condition
code register
(CC) is register 14. By convention, the stack pointer will be register 13 and
noted as (SP)--although there is nothing special about this register other
than this convention. Also by convention register~12 will point to a global
offset table, and may be abbreviated as the (GBL) register.
The CPU can access both register sets via move instructions from the
supervisor state, whereas the user state can only access the user registers.
The supervisor set is used when interrupts are disabled, whereas the user set
is used any time interrupts are enabled. This choice makes it easy to set up
a working context upon any interrupt, as the supervisor register set remains
what it was when interrupts were enabled. This sets up one of two modes
the CPU can run within: a {\em supervisor mode}, which runs with interrupts
disabled using the supervisor register set, and {\em user mode}, which runs
with interrupts enabled using the user register set.
 
The status register is special, and bears further mention. As shown in
This separation is so fundamental to the CPU that it is impossible to enable
interrupts without switching to the user register set. Further, on any
interrupt, exception, or trap, the CPU simply clears the pipeline and switches
instruction sets.
 
In each register set, the Program Counter (PC) is register 15, whereas
the status register (SR) or condition code register (CC) is register 14. All
other registers are identical in their hardware functionality.\footnote{Jumps
to {\tt R0}, an instruction used to implement a return from a subroutine, may
be optimized in the future within the early branch logic.} By convention, the
stack pointer is register 13 and noted as (SP)--although there is nothing
special about this register other than this convention. Also by convention, if
the compiler needs a frame pointer it will be placed into register~12, and may
be abbreviated by FP. Finally, by convention, R0 will hold a subroutine's
return address, sometimes called the link register (LR).
 
When the CPU is in supervisor mode, instructions can access both register sets
via the {\tt MOV} instruction, whereas when the CPU is in user mode, {\tt MOV}
instructions will only offer access to user registers. We'll discuss this
further in subsection.~\ref{sec:isa-mov}.
 
\subsection{The Status Register, CC}
The status register (CC) is special, and bears further mention. As shown in
Fig.~\ref{tbl:cc-register},
\begin{table}\begin{center}
\begin{bitlist}
31\ldots 23 & R & Reserved for future uses\\\hline
22\ldots 15 & R/W & Reserved for future uses\\\hline
14 & W & Clear I-Cache command\\\hline
22\ldots 16 & R/W & Reserved for future uses\\\hline
15 & R & Reserved for MMU exceptions\\\hline
14 & W & Clear I-Cache command, always reads zero\\\hline
13 & R & VLIW instruction phase (1 for first half)\\\hline
12 & R & (Reserved for) Floating Point Exception\\\hline
11 & R & Division by Zero Exception\\\hline
544,9 → 623,8
\end{bitlist}
\caption{Condition Code Register Bit Assignment}\label{tbl:cc-register}
\end{center}\end{table}
the lower 15~bits of the status register form
a set of CPU state and condition codes. Writes to other bits of this register
are preserved.
the lower sixteen bits of the status register form a set of CPU state and
condition codes. The other bits are reserved for future uses.
 
Of the condition codes, the bottom four bits are the current flags:
Zero (Z),
553,23 → 631,32
Carry (C),
Negative (N),
and Overflow (V).
On those instructions that set the flags, these flags will be set based upon
the output of the instruction. If the result is zero, the Z flag will be set.
If the high order bit is set, the N flag will be set. If the instruction
caused a bit to fall off the end, the carry bit will be set. Finally, if
the instruction causes a signed integer overflow, the V flag will be set
afterwards.
These flags maintain their usual definition from other CPUs that use them, for
all but the shift right instructions. On those instructions that set the flags,
these flags will be set based upon the output of certain instructions. If the
result is zero, the Z (zero) flag will be set. If the high order bit is set,
the N (negative) flag will be set. If the instruction caused a bit to fall off
the end, the carry bit will be set. In comparisons, this is equivalent to a
less--than unsigned comparison. Finally, if the instruction causes a signed
integer overflow, the V (overflow) flag will be set afterwards.
 
The next bit is a sleep bit. Set this bit to one to disable instruction
We'll walk through the next many bits of the status register in order from
least significant to most significant.
 
\begin{enumerate}
\setcounter{enumi}{3}
\item The next bit is a sleep bit. Set this bit to one to disable instruction
execution and place the CPU to sleep, or to zero to keep the pipeline
running. Setting this bit will cause the CPU to wait for an interrupt
(if interrupts are enabled), or to completely halt (if interrupts are
disabled). In order to prevent users from halting the CPU, only the
supervisor is allowed to both put the CPU to sleep and disable
interrupts. Any user attempt to do so will simply result in a switch
to supervisor mode.
disabled). This leads to the {\tt WAIT} and {\tt HALT} opcodes
which will be discussed more later. In order to prevent users from
halting the CPU, only the supervisor is allowed to both put the CPU to
sleep and disable interrupts. Any user attempt to do so will simply
result in a switch to supervisor mode.
 
The sixth bit is a global interrupt enable bit (GIE). When this
\item The sixth bit is a global interrupt enable bit (GIE). This bit also
forms the top, or fifth, bit of any register address. When this
sixth bit is a `1' interrupts will be enabled, else disabled. When
interrupts are disabled, the CPU will be in supervisor mode, otherwise
it is in user mode. Thus, to execute a context switch, one only
580,11 → 667,14
GIE register at the same time, with clearing the GIE register taking
precedence.
 
The seventh bit is a step bit. This bit can be set from supervisor mode only.
After setting this bit, should the supervisor mode process switch to
user mode, it would then accomplish one instruction in user mode
before returning to supervisor mode. Then, upon return to supervisor
mode, this bit will be automatically cleared. This bit has no effect
Whenever read, the supervisor CC register will always have this bit
cleared, whereas the user CC register will always have this bit set.
 
\item The seventh bit is a step bit in the user CC register, and zero in the
supervisor CC director. This bit can only be set from supervisor
mode. After setting this bit, should the supervisor mode process switch
to user mode, it would then accomplish one instruction in user mode
before returning to supervisor mode. This bit has no effect
on the CPU while in supervisor mode.
 
This functionality was added to enable a userspace debugger
591,70 → 681,83
functionality on a user process, working through supervisor mode
of course.
 
The CPU can be stepped in supervisor mode. Doing so requires the
CPU debug functionality, not the step bit.
 
The eighth bit is a break enable bit. When applied to the supervisor CC
register, this controls whether a break instruction in user mode will halt
the processor for an external debugger (break enabled), or whether the break
instruction will simply send send the CPU into interrupt mode. Encountering
a break in supervisor mode will halt the CPU independent of the break enable
bit. This bit can only be set within supervisor mode. However, when applied
to the user CC register, from supervisor mode, this bit will indicate whether
or not the reason the CPU entered supervisor mode was from a break instruction
or not. This break reason bit is automatically cleared upon any transition to
user mode, although it can also be cleared by the supervisor writing to the
user CC register.
 
% Should break enable be a supervisor mode bit, while the break enable bit
% in user mode is a break has taken place bit?
%
\item The eighth bit is a break enable bit. When applied to the supervisor CC
register, this controls whether a break instruction in user mode will
halt the processor for an external debugger (break enabled), or
whether the break instruction will simply send send the CPU into
interrupt mode. This bit can only be set within supervisor mode.
However, when applied to the user CC register, from supervisor mode,
this bit will indicate whether or not the reason the CPU entered
supervisor mode was from a break instruction or not. This break
reason bit is automatically cleared upon any transition to user mode,
although it can also be cleared by the supervisor writing to the
user CC register.
 
This functionality was added to enable an external debugger to
set and manage breakpoints.
Encountering a break in supervisor mode will halt the CPU independent
of the break enable bit.
 
The ninth bit is an illegal instruction bit. When the CPU
tries to execute either a non-existant instruction, or an instruction from
an address that produces a bus error, the CPU will (if implemented) switch
to supervisor mode while setting this bit. The bit will automatically be
cleared upon any return to user mode.
This functionality was added to enable a debugger to set and manage
breakpoints in a user mode process.
 
The tenth bit is a trap bit. It is set whenever the user requests a soft
interrupt, and cleared on any return to userspace command. This allows the
supervisor, in supervisor mode, to determine whether it got to supervisor
mode from a trap or from an external interrupt or both.
\item The ninth bit is an illegal instruction bit. When the CPU tries to
execute either a non-existent instruction, or an instruction from
an address that produces a bus error, the CPU will (if implemented)
switch to supervisor mode while setting this bit. The bit will
automatically be cleared upon any return to user mode.
 
The eleventh bit is a bus error flag. If the user program encountered a bus
error, this bit will be set in the user CC register and the CPU will switch to
supervisor mode. The bit may be cleared by the supervisor, otherwise it is
automatically cleared upon any return to user mode. If the supervisor
encounters a bus error, this bit will be set in the supervisor CC register
and the CPU will halt. In that case, either a CPU reset or a write to the
supervisor CC register will clear this register.
\item The tenth bit is a trap bit. It is set whenever the user requests a
soft interrupt, and cleared on any return to userspace command. This
allows the supervisor, in supervisor mode, to determine whether it got
to supervisor mode from a trap, from an external interrupt or both.
 
The twelth bit is a division by zero exception flag. This operates in a fashion
similar to the bus error flag. If the user attempts to use the divide
instruction with a zero denominator, the system will switch to supervisor mode
and set this bit in the user CC register. The bit is automatically cleared
upon any return to user mode, although it can also be manually cleared by
the supervisor. In a similar fashion, if the supervisor attempts to execute
a divide by zero, the CPU will halt and set the zero exception flag in the
supervisor's CC register. This will automatically be cleared upon any CPU
reset, or it may be manually cleared by the external debugger writing to this
register.
\item The eleventh bit is a bus error flag. If the user program encountered
a bus error, this bit will be set in the user CC register and the CPU
will switch to supervisor mode. The bit may be cleared by the
supervisor, otherwise it is automatically cleared upon any return to
user mode. If the supervisor encounters a bus error, this bit will be
set in the supervisor CC register and the CPU will halt. In that
case, either a CPU reset or a write to the supervisor CC register will
clear this register.
 
The thirteenth bit will operate in a similar fashion to both the bus error
and division by zero flags, only it will be set upon a (yet to be determined)
floating point error.
\item The twelfth bit is a division by zero exception flag. This operates
in a fashion similar to the bus error flag. If the user attempts
to use the divide instruction with a zero denominator, the system
will switch to supervisor mode and set this bit in the user CC
register. The bit is automatically cleared upon any return to user
mode, although it can also be manually cleared by the supervisor. In
a similar fashion, if the supervisor attempts to execute a divide by
zero, the CPU will halt and set the zero exception flag in the
supervisor's CC register. This will automatically be cleared upon any
CPU reset, or it may be manually cleared by the external debugger
writing to this register.
 
Finally, the fourteenth bit references a clear cache bit. The supervisor may
write a one to this bit in order to clear the CPU instruction cache. The
bit always reads as a zero.
\item The thirteenth bit will operate in a similar fashion to both the bus
error and division by zero flags, only it will be set upon a (yet to
be determined) floating point error.
 
\item In the case of VLIW instructions, if an exception occurs after the first
instruction but before the second, the fourteenth bit of the CC register
will be set to indicate this fact.
 
\item The fifteenth bit references a clear cache bit. The supervisor may
write a one to this bit in order to clear the CPU instruction cache.
The bit always reads as a zero.
 
\item Last, but not least, the sixteenth bit is reserved for a page not found
memory exception to be created by the memory management unit.
 
\end{enumerate}
 
Some of the upper bits have been temporarily assigned to indicate CPU
capabilities. This is not a permanent feature, as these upper bits officially
remain reserved.
 
\section{Instruction Format}
All Zip CPU instructions fit in one of the formats shown in
\subsection{Instruction Format}\label{sec:isa-fmt}
All ZipCPU instructions fit in one of the formats shown in
Fig.~\ref{fig:iset-format}.
\begin{figure}\begin{center}
\begin{bytefield}[endianness=big]{32}
732,124 → 835,100
\end{center}\end{figure}
The basic format is that some operation, defined by the OpCode, is applied
if a condition, Cnd, is true in order to produce a result which is placed in
the destination register, or DR. The load 23--bit signed immediate instruction
(LDI) is different in that it accepts no conditions, and uses only a 4-bit
opcode.
the destination register (DR). There are three basic exceptions to this
model. The first is the {\tt MOV} instruction, which steals bits~13 and~18
to allow supervisor access to user registers. The second is the load 23--bit
signed immediate instruction ({\tt LDI}), in that it accepts no conditions and
uses only a 4-bit opcode. The last exception is the {\tt NOOP} instruction
group, containing the {\tt NOOP}, {\tt BREAK}, and {\tt LOCK} opcodes. These
instructions ignore their register and immediate settings.\footnote{A future
version of the CPU may repurpose the immediate bits within the {\tt NOOP}
instruction to be simulator commands, while the immediate/register bits within
the {\tt BREAK} instruction may be used by the debugger for whatever purpose
it chooses to use them for--such as a breakpoint table index.}
 
This is actually a second version of instruction set definition, given certain
lessons learned. For example, the original instruction set had the following
problems:
\begin{enumerate}
\item No opcodes were available for divide or floating point extensions to be
made available. Although there was space in the instruction set to
add these types of instructions, this instruction space was going to
require extra logic to use.
\item The carveouts for instructions such as NOOP and LDIHI/LDILO required
extra logic to process.
\item The instruction set wasn't very compact. One bus operation was required
for every instruction.
\item While the CPU supported multiplies, they were only 16x16 bit multiplies.
\end{enumerate}
This second version was designed with two criteria. The first was that the
new instruction set needed to be compatible, at the assembly language level,
with the previous instruction set. Thus, it must be able to support all of
the previous menumonics and more. This was achieved with the sole exception
that instruction immediates are generally two bits shorter than before.
(One bit was lost to the VLIW bit in front, another from changing from 4--bit
to 5--bit opcodes.) Second, the new instruction set needed to be a drop--in
replacement for the decoder, modifying nothing else. This was almost achieved,
save for two issues: the ALU unit needed to be replaced since the OpCodes
were reordered, and some condition code logic needed to be adjusted since the
condition codes were renumbered as well. In the end, maximum reuse of the
existing RTL (Verilog) code was achieved in this upgrade.
The ZipCPU also supports a very long instruction word (VLIW) set of
instructions. These aren't truly VLIW instructions in the sense that the CPU
still only issues one instruction at a time, but they do pack two instructions
into a single instuction word. The number of bits used by the immediate field
are adjusted to make space for these instruction words. Other than instruction
format, the only basic difference between VLIW and normal instructions is that
the CPU will not switch to interrupt mode in between the two instructions,
unless an exception is generated by the first instruction. Likewise a new job
given to the assembler is that of automatically packing as many instructions as
possible into the VLIW format.
 
As of this second version of the Zip CPU instruction set, the Zip CPU also
supports a very long instruction word (VLIW) set of instructions. These
instruction formats pack two instructions into a single instuction word,
trading immediate instruction space to do this, but in just about all other
respects these are identical to two standard instructions. Other than
instruction format, the only basic difference is that the CPU will not switch
to interrupt mode in between the two instructions. Likewise a new job given
to the assembler is that of automatically packing as many instructions as
possible into the VLIW format. Where necessary to place both VLIW instructions
on the same line, they will be separated by a vertical bar.
The disassembler will represent VLIW instructions by placing a vertical bar
between the two components, but still leaving them on the same line.
 
One belated change to the instruction set violates some of the above
principles. This latter instruction set change replaced the {\tt LDIHI}
instruction with a 32--bit multiply instruction {\tt MPY}, and then changed
the two 16--bit multiply instructions {\tt MPYU} and {\tt MPYS} for
{\tt MPYUHI} and {\tt MPYSHI} respectively. This creates a 32--bit
multiply capability, while removing the 16--bit multiply that wasn't very
useful. Further, the {\tt LDIHI} instruction was being used primarily by the
assembler and linker to create a 32--bit load immediate pair of instructions.
This instruction set combination, {\tt LDIHI} followed by {\tt LDILO} was
replaced with an equivalent instruction set, {\tt BREV} followed by {\tt LDILO},
save that linking has been made more complicated in the process.
 
\section{Instruction OpCodes}
\subsection{Instruction OpCodes}\label{sec:isa-opcodes}
With a 5--bit opcode field, there are 32--possible instructions as shown in
Tbl.~\ref{tbl:iset-opcodes}.
\begin{table}\begin{center}
\begin{tabular}{|l|l|l|c|} \hline \rowcolor[gray]{0.85}
OpCode & & Instruction &Sets CC \\\hline\hline
5'h00 & SUB & Subtract & \\\cline{1-3}
5'h01 & AND & Bitwise And & \\\cline{1-3}
5'h02 & ADD & Add two numbers & \\\cline{1-3}
5'h03 & OR & Bitwise Or & Y \\\cline{1-3}
5'h04 & XOR & Bitwise Exclusive Or & \\\cline{1-3}
5'h05 & LSR & Logical Shift Right & \\\cline{1-3}
5'h06 & LSL & Logical Shift Left & \\\cline{1-3}
5'h07 & ASR & Arithmetic Shift Right & \\\hline
5'h08 & MPY & 32x32 bit multiply & Y \\\hline
5'h09 & LDILO & Load Immediate Low & N\\\hline
5'h0a & MPYUHI & Upper 32 of 64 bits from an unsigned 32x32 multiply & \\\cline{1-3}
5'h0b & MPYSHI & Upper 32 of 64 bits from a signed 32x32 multiply & Y \\\cline{1-3}
5'h0c & BREV & Bit Reverse & \\\cline{1-3}
5'h0d & POPC& Population Count & \\\cline{1-3}
5'h0e & ROL & Rotate left & \\\hline
5'h0f & MOV & Move register & N \\\hline
5'h10 & CMP & Compare & Y \\\cline{1-3}
5'h11 & TST & Test (AND w/o setting result) & \\\hline
5'h12 & LOD & Load from memory & N \\\cline{1-3}
5'h13 & STO & Store a register into memory & \\\hline\hline
5'h14 & DIVU & Divide, unsigned & Y \\\cline{1-3}
5'h15 & DIVS & Divide, signed & \\\hline\hline
5'h16/7 & LDI & Load 23--bit signed immediate & N \\\hline\hline
5'h18 & FPADD & Floating point add & \\\cline{1-3}
5'h19 & FPSUB & Floating point subtract & \\\cline{1-3}
5'h1a & FPMPY & Floating point multiply & Y \\\cline{1-3}
5'h1b & FPDIV & Floating point divide & \\\cline{1-3}
5'h1c & FPCVT & Convert integer to floating point & \\\cline{1-3}
5'h1d & FPINT & Convert to integer & \\\hline
5'h00 & {\tt SUB} & Subtract & \\\cline{1-3}
5'h01 & {\tt AND} & Bitwise And & \\\cline{1-3}
5'h02 & {\tt ADD} & Add two numbers & \\\cline{1-3}
5'h03 & {\tt OR} & Bitwise Or & Y \\\cline{1-3}
5'h04 & {\tt XOR} & Bitwise Exclusive Or & \\\cline{1-3}
5'h05 & {\tt LSR} & Logical Shift Right & \\\cline{1-3}
5'h06 & {\tt LSL} & Logical Shift Left & \\\cline{1-3}
5'h07 & {\tt ASR} & Arithmetic Shift Right & \\\hline
5'h08 & {\tt MPY} & 32x32 bit multiply & Y \\\hline
5'h09 & {\tt LDILO} & Load Immediate Low & N\\\hline
5'h0a & {\tt MPYUHI} & Upper 32 of 64 bits from an unsigned 32x32 multiply & \\\cline{1-3}
5'h0b & {\tt MPYSHI} & Upper 32 of 64 bits from a signed 32x32 multiply & Y \\\cline{1-3}
5'h0c & {\tt BREV} & Bit Reverse B operand into result& \\\cline{1-3}
5'h0d & {\tt POPC}& Population Count & \\\cline{1-3}
5'h0e & {\tt ROL} & Rotate Ra left by OpB bits& \\\hline
5'h0f & {\tt MOV} & Move OpB into Ra & N \\\hline
5'h10 & {\tt CMP} & Compare (Ra-OpB) to zero & Y \\\cline{1-3}
5'h11 & {\tt TST} & Test (AND w/o setting result) & \\\hline
5'h12 & {\tt LOD} & Load Ra from memory (OpB) & N \\\cline{1-3}
5'h13 & {\tt STO} & Store Ra into memory at (OpB) & \\\hline\hline
5'h14 & {\tt DIVU} & Divide, unsigned & Y \\\cline{1-3}
5'h15 & {\tt DIVS} & Divide, signed & \\\hline\hline
5'h16/7 & {\tt LDI} & Load 23--bit signed immediate & N \\\hline\hline
5'h18 & {\tt FPADD} & Floating point add & \\\cline{1-3}
5'h19 & {\tt FPSUB} & Floating point subtract & \\\cline{1-3}
5'h1a & {\tt FPMPY} & Floating point multiply & Y \\\cline{1-3}
5'h1b & {\tt FPDIV} & Floating point divide & \\\cline{1-3}
5'h1c & {\tt FPI2F} & Convert integer to floating point & \\\cline{1-3}
5'h1d & {\tt FPF2I} & Convert floating point to integer & \\\hline
5'h1e & & {\em Reserved for future use} &\\\hline
5'h1f & & {\em Reserved for future use} &\\\hline
5'h18 & & NOOP (A-register = PC)&\\\cline{1-3}
5'h19 & & BREAK (A-register = PC)& N\\\cline{1-3}
5'h1a & & LOCK (A-register = PC)&\\\hline
5'h18 & & \hbox to 0.5in{\tt NOOP} (A-register = PC)&\\\cline{1-3}
5'h19 & & \hbox to 0.5in{\tt BREAK} (A-register = PC)& N\\\cline{1-3}
5'h1a & & \hbox to 0.5in{\tt LOCK} (A-register = PC)&\\\hline
\end{tabular}
\caption{Zip CPU OpCodes}\label{tbl:iset-opcodes}
\caption{ZipCPU OpCodes}\label{tbl:iset-opcodes}
\end{center}\end{table}
%
Of these opcodes, the {\tt BREV} and {\tt POPC} are experimental, and may be
replaced later, and two floating point instruction opcodes are reserved for
future use.
Of these opcodes, {\tt ROL} and {\tt POPC} are experimental and may be
replaced in future revisions. (If you have a reason to like or wish to keep
these opcodes, please contact me. If you know of alternatives that might be
better, please let me know as well.) There is also room for six more
register-less instructions in the {\tt NOOP} instruction space,
and two floating point instruction opcodes have been reserved for future use.
 
\section{Conditional Instructions}
\subsection{Conditional Instructions}\label{sec:isa-cond}
Most, although not quite all, instructions may be conditionally executed.
The 23--bit load immediate instruction, together with the {\tt NOOP},
{\tt BREAK}, and {\tt LOCK} instructions are the only exception to this rule.
{\tt BREAK}, and {\tt LOCK} instructions are the exceptions to this rule.
All other instructions may be conditionally executed.
 
From the four condition code flags, eight conditions are defined for standard
instructions. These are shown in Tbl.~\ref{tbl:conditions}.
\begin{table}\begin{center}
\begin{tabular}{l|l|l}
Code & Mneumonic & Condition \\\hline
Code & Mnemonic & Condition \\\hline
3'h0 & None & Always execute the instruction \\
3'h1 & {\tt .LT} & Less than ('N' set) \\
3'h1 & {\tt .LT}& Less than ('N' set) \\
3'h2 & {\tt .Z} & Only execute when 'Z' is set \\
3'h3 & {\tt .NZ} & Only execute when 'Z' is not set \\
3'h4 & {\tt .GT} & Greater than ('N' not set, 'Z' not set) \\
3'h5 & {\tt .GE} & Greater than or equal ('N' not set, 'Z' irrelevant) \\
3'h3 & {\tt .NZ}& Only execute when 'Z' is not set \\
3'h4 & {\tt .GT}& Greater than ('N' not set, 'Z' not set) \\
3'h5 & {\tt .GE}& Greater than or equal ('N' not set, 'Z' irrelevant) \\
3'h6 & {\tt .C} & Carry set (Also known as less-than unsigned) \\
3'h7 & {\tt .V} & Overflow set\\
\end{tabular}
856,40 → 935,41
\caption{Conditions for conditional operand execution}\label{tbl:conditions}
\end{center}\end{table}
There is no condition code for less than or equal, not C or not V---there
just wasn't enough space in 3--bits. Conditioning on a non--supported
condition is still possible, but it will take an extra instruction and a
pipeline stall. (Ex: \hbox{\em (Stall)}; \hbox{\tt TST \$4,CC;} \hbox{\tt
STO.NZ R0,(R1)}) As an alternative, it is often possible to reverse the
condition, and thus recovering those extra two clocks. Thus instead of
\hbox{\tt CMP Rx,Ry;} \hbox{\tt BNC label} you can issue a
\hbox{\tt CMP 1+Ry,Rx;} \hbox{\tt BC label}.
just wasn't enough space in 3--bits. Ways of handling non--supported
conditions are discussed in Sec.~\ref{sec:in-mcond}.
 
Conditionally executed instructions will not further adjust the
condition codes, with the exception of \hbox{\tt CMP} and \hbox{\tt TST}
instructions. Conditional \hbox{\tt CMP} or \hbox{\tt TST} instructions
will adjust conditions whenever they are executed. In this way,
multiple conditions may be evaluated without branches. For example, to do
something if \hbox{\tt R0} is one and \hbox{\tt R1} is two, one might try
code such as Tbl.~\ref{tbl:dbl-condition}.
With the exception of \hbox{\tt CMP} and \hbox{\tt TST} instructions,
conditionally executed instructions will not further adjust the condition codes.
Conditional \hbox{\tt CMP} or \hbox{\tt TST} instructions will adjust conditions
whenever they are executed. In this way, multiple conditions may be evaluated
without branches, creating a sort of logical and--but only if all the conditions
are the same. For example, to do something if \hbox{\tt R0} is one and
\hbox{\tt R1} is two, one might try code such as Tbl.~\ref{tbl:dbl-condition}.
\begin{table}\begin{center}
\begin{tabular}{l}
{\tt CMP 1,R0} \\
{;\em Condition codes are now set based upon R0-1} \\
{\em ; Condition codes are now set based upon R0-1} \\
{\tt CMP.Z 2,R1} \\
{;\em If R0 $\neq$ 1, conditions are unchanged.} \\
{;\em If R0 $=$ 1, conditions are set based upon R1-2.} \\
{;\em Now do something based upon the conjunction of both conditions.} \\
{;\em While we use the example of a STO, it could be any instruction.} \\
{\em ; If R0 $\neq$ 1, conditions are unchanged, {\tt Z} is still false.} \\
{\em ; If R0 $=$ 1, conditions are now set based upon R1-2.} \\
{\em ; Now some instruction could be done based upon the conjunction} \\
{\em ; of both conditions.} \\
{\em ; While we use the example of a {\tt STO}, it could easily be any
instruction.} \\
{\tt STO.Z R0,(R2)} \\
\end{tabular}
\caption{An example of a double conditional}\label{tbl:dbl-condition}
\end{center}\end{table}
 
The real utility of conditionally executed instructions is that, unlike
conditional branches, conditionally executed instructions will not stall
the bus if they are not executed.
 
In the case of VLIW instructions, only four conditions are defined as shown
in Tbl.~\ref{tbl:vliw-conditions}.
\begin{table}\begin{center}
\begin{tabular}{l|l|l}
Code & Mneumonic & Condition \\\hline
Code & Mnemonic & Condition \\\hline
2'h0 & None & Always execute the instruction \\
2'h1 & {\tt .LT} & Less than ('N' set) \\
2'h2 & {\tt .Z} & Only execute when 'Z' is set \\
897,61 → 977,15
\end{tabular}
\caption{VLIW Conditions}\label{tbl:vliw-conditions}
\end{center}\end{table}
Further, the first bit is given a special meaning. If the first bit is set,
the conditions apply to the second half of the instruction, otherwise the
conditions will only apply to the first half of a conditional instruction.
Of course, the other conditions are still available by mingling the
non--VLIW instructions with VLIW instructions.
Further, the first bit of the three is given a special meaning: If the first
bit is set, the conditions apply to the second half of the instruction,
otherwise the conditions will only apply to the first half of a conditional
instruction. Of course, the other conditions are still available by mingling
the non--VLIW instructions with VLIW instructions.
 
\section{Operand B}
Many instruction forms have a 19-bit source ``Operand B'' associated with them.
This ``Operand B'' is shown in Fig.~\ref{fig:iset-format} as part of the
standard instructions. This Operand B is either equal to a register plus a
14--bit signed immediate offset, or an 18--bit signed immediate offset by
itself. This value is encoded as shown in Tbl.~\ref{tbl:opb}.
\begin{table}\begin{center}
\begin{bytefield}[endianness=big]{19}
\bitheader{0-18} \\
\bitbox{1}{0}\bitbox{18}{18-bit Signed Immediate} \\
\bitbox{1}{1}\bitbox{4}{Reg}\bitbox{14}{14-bit Signed Immediate}
\end{bytefield}
\caption{Bit allocation for Operand B}\label{tbl:opb}
\end{center}\end{table}
 
Fourteen and eighteen bit immediate values don't make sense for all
instructions. For example, what is the point of an 18--bit immediate when
executing a 16--bit multiply? Or a 16--bit load--immediate? In these cases,
the extra bits are simply ignored.
 
VLIW instructions still use the same operand B, only there was no room for any
instruction plus immediate addressing. Therefore, VLIW instructions have either
a register or a 4--bit signed immediate as their operand B. The only exception
is the load immediate instruction, which permits a 5--bit signed operand
B.\footnote{Although the space exists to extend this VLIW load immediate
instruction to six bits, the 5--bit limit was chosen to simplify the
disassembler. This may change in the future.}
 
\section{Address Modes}
The Zip CPU supports two addressing modes: register plus immediate, and
immediate address. Addresses are therefore encoded in the same fashion as
Operand B's, shown above. Practically, the VLIW instruction set only offers
register addressing, necessitating a non--VLIW instruction for most memory
operations.
 
A lot of long hard thought was put into whether to allow pre/post increment
and decrement addressing modes. Finding no way to use these operators without
taking two or more clocks per instruction,\footnote{The two clocks figure
comes from the design of the register set, allowing only one write per clock.
That write is either from the memory unit or the ALU, but never both.} these
addressing modes have been
removed from the realm of possibilities. This means that the Zip CPU has no
native way of executing push, pop, return, or jump to subroutine operations.
Each of these instructions can be emulated with a set of instructions from the
existing set.
 
\section{Modifying Conditions}
A quick look at the list of conditions supported by the Zip CPU and listed
in Tbl.~\ref{tbl:conditions} reveals that the Zip CPU does not have a full set
\subsection{Modifying Conditions}\label{sec:in-mcond}
A quick look at the list of conditions supported by the ZipCPU and listed
in Tbl.~\ref{tbl:conditions} reveals that the ZipCPU does not have a full set
of conditions. In particular, only one explicit unsigned condition is
supported. Therefore, Tbl.~\ref{tbl:creating-conditions}
\begin{table}\begin{center}
981,57 → 1015,101
shows examples of how these unsupported conditions can be created
simply by adjusting the compare instruction, for no extra cost in clocks.
Of course, if the compare originally had an immediate within it, that immediate
would need to be loaded into a register in order to do some of these compares.
This case is shown as the last case above.
would need to be loaded into a register in order to do make some of these
adjustments. That case is shown as the last case above.
 
\section{Move Operands}
The previous set of operands would be perfect and complete, save only that
the CPU needs access to non--supervisory registers while in supervisory mode.
Therefore, the MOV instruction is special and offers access to these registers
\ldots when in supervisory mode. To keep the compiler simple, the extra bits
are ignored in non-supervisory mode (as though they didn't exist), rather than
being mapped to new instructions or additional capabilities. The bits
indicating which register set each register lies within are the A-User, marked
`A' in Fig.~\ref{fig:iset-format}, and B-User bits, marked as `B'. When set
to a one, these refer to a user mode register. When set to a zero, these
refer to a register in the current mode, whether user or supervisor. Further,
because a load immediate instruction exists, there is no move capability
between an immediate and a register: all moves come from either a register or
a register plus an offset.
Many of these alternate conditions are chosen by the compiler implementation.
 
This actually leads to a bit of a problem: since the {\tt MOV} instruction
encodes which register set each register is coming from or moving to, how shall
a compiler or assembler know how to compile a MOV instruction without knowing
the mode of the CPU at the time? For this reason, the compiler will assume
all MOV registers are supervisor registers, and display them as normal.
Anything with the user bit set will be treated as a user register and displayed
special. Since the CPU quietly ignores the supervisor bits while in user mode,
anything marked as a user register will always be specific.
Users should be aware of any signed overflow that might take place within the
modified conditions, especially when numbers close to the limit are used.
 
\section{Multiply Operations}
 
The ZipCPU originally only supported 16x16 multiply operations. GCC, however,
wanted 32x32-bit operations and building these from 16x16-bit multiplies
is painful. Therefore, the ZipCPU was modified to support 32x32-bit multiplies.
\subsection{Operand B}\label{sec:isa-opb}
Many instruction forms have a 19-bit source ``Operand B'', or OpB for short,
associated with them. This ``Operand B'' is shown in
Fig.~\ref{fig:iset-format} as part of the standard instructions. An Operand B
is either equal to a register plus a 14--bit signed immediate offset, or an
18--bit signed immediate offset by itself. This value is encoded as shown in
Tbl.~\ref{tbl:opb}.
\begin{table}\begin{center}
\begin{bytefield}[endianness=big]{19}
\bitheader{0-18} \\
\bitbox{1}{0}\bitbox{18}{18-bit Signed Immediate} \\
\bitbox{1}{1}\bitbox{4}{Reg}\bitbox{14}{14-bit Signed Immediate}
\end{bytefield}
\caption{Bit allocation for Operand B}\label{tbl:opb}
\end{center}\end{table}
This format represents a deviation from many other RISC architectures that use
{\tt R0} to represent zero, such as OpenRISC and RISC-V. Here, instead, we use
a bit within the instruction to note whether or not an immediate is used.
The result is that ZipCPU instructions can encode larger immediates within their
instruction space.
 
In particular, the ZipCPU supports three separate 32x32-bit multiply
In those cases where a fourteen or eighteen bit immediate doesn't make sense,
such as for {\tt LDILO}, the extra bits associated with the immediate are
simply ignored. (This rule does not apply to the shift instructions,
{\tt ASR}, {\tt LSR}, and {\tt LSL}--which all use all of their immediate bits.)
 
VLIW instructions still use the same operand B as regular instructions, only
there was no room for any instruction plus immediate addressing. Therefore,
VLIW instructions have either
a register or a 4--bit signed immediate as their operand B. The only exception
is the load immediate instruction, which permits a 5--bit signed operand
B.\footnote{Although the space exists to extend this VLIW load immediate
instruction to six bits, the 5--bit limit was chosen to simplify the
disassembler. This may change in the future.}
 
\subsection{Address Modes}\label{sec:isa-addr}
The ZipCPU supports two addressing modes: register plus immediate, and
immediate addressing. Addresses are encoded in the same fashion as
Operand B's, discussed above.
 
The VLIW instruction set only offers register addressing.
 
\subsection{Move Operands}\label{sec:isa-mov}
The previous set of operands would be perfect and complete, save only that the
CPU needs access to non--supervisory registers while in supervisory mode. The
MOV instruction has been modified to fit that purpose. The two bits,
shown as {\tt A} and {\tt B} in Fig.~\ref{fig:iset-format} above, are designed
to contain the high order bit of the 5--bit register index. If the {\tt B}
bit is a `1', the source operand comes from the user register set. If the
{\tt A} bit is a `1', the destination operand is in the user register set. A
zero bit indicates the current register set.
 
This encoding has been chosen to keep the compiler simple. For the most part,
the extra bits are quietly set to zero by the compiler. Assembly instructions,
or particular built--in instructions, can be used to get access to these
cross register set move instructions.
 
Further, the {\tt MOV} instruction lacks the full OpB capability to use a
register or a register plus immediate as a source, since a load immediate
instruction already exists. As a result, all moves come from a register plus a
potential offset.
 
\subsection{Multiply Operations}\label{sec:isa-mpy}
 
The ZipCPU supports three separate 32x32-bit multiply
instructions: {\tt MPY}, {\tt MPYUHI}, and {\tt MPYSHI}. The first of these
produces the low 32-bits of a 32x32-bit multiply result. The second two
produce the upper 32-bits. The first, {\tt MPYUHI}, produces the upper 32-bits
assuming the multiply was unsigned, whereas the second assuming it was signed.
Each multiply instruction is independent of each other in execution, although
the compiler may use them quite dependently.
assuming the multiply was unsigned, whereas {\tt MPYSHI} assumes it was signed.
Each multiply instruction is independent of every other in execution, although
the compiler is likely to use them in a dependent fashion.
 
In an effort to maintain single clock pipeline timing, all three of these
multiplies have been slowed down in logic. Thus, depending upon the setting
of {\tt OPT\_MULTIPLY} within {\tt cpudefs.v}, the multiply instructions
will either 1)~cause an ILLEGAL instruction error, 2)~take one additional clock,
or 3)~take two additional clocks.
In an effort to maintain a fast clock speed, all three of these multiplies
have been slowed down in logic. Thus, depending upon the setting of
{\tt OPT\_MULTIPLY} within {\tt cpudefs.v}, or the corresponding
{\tt IMPLEMENT\_MPY} parameter that may override it, the multiply instructions
will either 1)~cause an ILLEGAL instruction error ({\tt OPT\_MULTIPLY=0}, or
no multiply support), 2)~take one additional clock ({\tt OPT\_MULTIPLY=2}),
or 3)~take two additional clock cycles ({\tt OPT\_MULTIPLY=3}).\footnote{Support
also exists for a one clock multiply (no clock slowdown), or a four clock
multiply, and I am anticipating supporting a much longer multiply for FPGA
architectures with no accelerated hardware multiply support.}
 
 
\section{Divide Unit}
The Zip CPU also has a divide unit which can be built alongside the ALU.
This divide unit provides the Zip CPU with another two instructions that
\subsection{Divide Unit}
The ZipCPU also has an optional divide unit which can be built alongside the
ALU. This divide unit provides the ZipCPU with another two instructions that
cannot be executed in a single cycle: {\tt DIVS}, or signed divide, and
{\tt DIVU}, the unsigned divide. These are both 32--bit divide instructions,
dividing one 32--bit number by another. In this case, the Operand B field,
1038,35 → 1116,39
whether it be register or register plus immediate, constitutes the denominator,
whereas the numerator is given by the other register.
 
The Divide is also a multi--clock instruction. While the divide is running,
the ALU, any memory loads, and the floating point unit (if installed) will be
idle. Once the divide completes, other units may continue.
As with the multiply, the divide instructions are also a multi--clock
instructions. While the divide is running, the ALU, any memory loads, and the
floating point unit (if installed) will be idle. Once the divide completes,
other units may continue.
 
Of course, divides can have errors: division by zero. In the case of division
by zero, an exception will be caused that will send the CPU either from
user mode to supervisor mode, or halt the CPU if it is already in supervisor
mode.
Of course, any divide instruction can result in a division by zero exception.
If this happens the CPU will either suddenly transition from user mode to
supervisor mode, or it will halt if the CPU is already in supervisor mode. Upon
exception, the divide by zero bit will be set in the CC register. In the
case of a user mode divide by zero, this will be cleared by any return to user
mode command. The supervisor bit may be cleared either by a reboot or by the
external debugger.
 
\section{NOOP, BREAK, and Bus Lock Instruction}
\subsection{NOOP, BREAK, and Bus LOCK Instruction}
Three instructions within the opcode list in Tbl.~\ref{tbl:iset-opcodes}, are
somewhat special. These are the {\tt NOOP}, {\tt Break}, and bus {\tt LOCK}
somewhat special. These are the {\tt NOOP}, {\tt BREAK}, and bus {\tt LOCK}
instructions. These are encoded according to
Fig.~\ref{fig:iset-noop}, and have the following meanings:
Fig.~\ref{fig:iset-noop}.
\begin{figure}\begin{center}
\begin{bytefield}[endianness=big]{32}
\bitheader{0-31}\\
\begin{leftwordgroup}{NOOP}
\bitbox{1}{0}\bitbox{3}{3'h7}\bitbox{1}{}
\bitbox{2}{11}\bitbox{3}{000}\bitbox{22}{Ignored} \\
\bitbox{2}{11}\bitbox{3}{000}\bitbox{22}{Reserved for Simulator} \\
\bitbox{1}{1}\bitbox{3}{3'h7}\bitbox{1}{}
\bitbox{2}{11}\bitbox{3}{000}\bitbox{22}{---} \\
\bitbox{1}{1}\bitbox{9}{---}\bitbox{3}{---}\bitbox{5}{---}
\bitbox{3}{3'h7}\bitbox{1}{}\bitbox{2}{11}\bitbox{3}{001}
\bitbox{5}{Ignored}
\bitbox{5}{Rsrvd}
\end{leftwordgroup} \\
\begin{leftwordgroup}{BREAK}
\bitbox{1}{0}\bitbox{3}{3'h7}
\bitbox{1}{}\bitbox{2}{11}\bitbox{3}{001}\bitbox{22}{Ignored}
\bitbox{1}{}\bitbox{2}{11}\bitbox{3}{001}\bitbox{22}{Reserved for debugger}
\end{leftwordgroup} \\
\begin{leftwordgroup}{LOCK}
\bitbox{1}{0}\bitbox{3}{3'h7}
1077,55 → 1159,66
\end{center}\end{figure}
 
The {\tt NOOP} instruction is just that: an instruction that does not perform
any operation. While many other instructions, such as a move from a register to
itself, could also fit these roles, only the NOOP instruction guarantees that
it will not stall waiting for a register to be available. For this reason,
it gets its own place in the instruction set.
any operation. While many other instructions, such as a move from a register
to itself, could also fit this role, only the NOOP instruction guarantees
that it will not stall waiting for a register to be available. For this
reason, it gets its own place in the instruction set. Bits 21--0 of this
instruction are reserved for commands which may be given to a simulator, such
as simulator exit, should the code be run from a simulator. However, such
simulation codes have not yet been defined.
 
The {\tt BREAK} instruction is useful for creating a debug instruction that
will halt the CPU without executing. If in user mode, depending upon the
setting of the break enable bit, it will either switch to supervisor mode or
halt the CPU--depending upon where the user wishes to do his debugging.
halt the CPU--depending upon where the user wishes to do his debugging. The
lower 22~bits of this instruction are likewise reserved for the debuggers
use.
 
Finally, the {\tt LOCK} instruction was added in order to provide for
atomic operations. The {\tt LOCK} instruction only works in pipeline mode.
It works by stalling the ALU pipeline stack until all prior stages are
filled, and then it guarantees that once a bus cycle is started, the
wishbone {\tt CYC} line will remain asserted until the LOCK is deasserted.
This allows the execution of one instruction that was waiting in the load
operands pipeline stage, and one instruction that was waiting in the
instruction decode stage. Further, if the instruction waiting in the decode
stage was a VLIW instruction, then it may be possible to execute a third
instruction.
atomic operations. The {\tt LOCK} instruction only works when the CPU is
configured for pipeline mode. It works by stalling the ALU pipeline stack
until all prior stages are filled, and then it guarantees that once a bus
cycle is started, the wishbone {\tt CYC} line will remain asserted until the
LOCK is deasserted. This allows the execution of three instructions, one
memory (ex. {\tt LOD}), one ALU (ex. {\tt ADD}), and another memory instruction
(ex. {\tt STO}), to take place in an unbreakable fashion. Example uses of this
capability include an atomic increment, such as {\tt LOCK}, {\tt LOD (Rx),Ry},
{\tt ADD \#,Ry}, and then {\tt STO Ry,(Rx)}, or even a two instruction pair
such as a test and set sequence: {\tt LDI 1,Rz}, {\tt LOCK}, {\tt LOD (Rx),Ry},
{\tt STO Rz,(Rx)}.
 
This was originally written to implement an atomic test and set instruction,
such as a {\tt LOCK} followed by {\tt LOD (Rx),Ry} and a {\tt STO Rz,(Rx)},
where Rz is initially set.
 
Other instructions using a VLIW instruction combining a single ALU instruction
with a store, such as an atomic increment, or {\tt LOCK}, {\tt LOD (Rx),Ry},
{\tt ADD 1,Ry}, {\tt STO Ry,(Rx)}, should be possible as well. Many of these
combinations remain to be tested.
 
\section{Floating Point}
Although the Zip CPU does not (yet) have a floating point unit, the current
\subsection{Floating Point}
Although the ZipCPU does not (yet) have a floating point unit, the current
instruction set offers eight opcodes for floating point operations, and treats
floating point exceptions like divide by zero errors. Once this unit is built
and integrated together with the rest of the CPU, the Zip CPU will support
and integrated together with the rest of the CPU, the ZipCPU will support
32--bit floating point instructions natively. Any 64--bit floating point
instructions will still need to be emulated in software.
instructions will either need to be emulated in software, or else they will
need an external floating point peripheral.
 
Until that time, of even after if the floating point unit is not installed,
floating point instructions will trigger an illegal instruction exception,
which may be trapped and then implemented in software.
Until the FPU is built and integrated, of even afterwards if the floating point
unit is not installed by option, floating point instructions will trigger an
illegal instruction exception, which may be trapped and then implemented in
software.
 
\section{Derived Instructions}
The Zip CPU supports many other common instructions, but not all of them
are single cycle instructions. The derived instruction tables,
Tbls.~\ref{tbl:derived-1}, \ref{tbl:derived-2}, \ref{tbl:derived-3}
and~\ref{tbl:derived-4},
help to capture some of how these other instructions may be implemented on
the Zip CPU. Many of these instructions will have assembly equivalents,
\subsection{Load/Store byte}
One difference between the ZipCPU and many other architectures is that there are
no load byte {\tt LB}, store byte {\tt SB}, load halfword {\tt LH} or store
halfword {\tt SH} instructions. This lack is by design in an attempt to keep
the 32--bit bus simple.
 
Because the ZipCPU's addresses refer to 32--bit values, i.e. address one
will refer to a completely different 32--bit value than address two, simulating
these load and store byte instructions is difficult.
 
This is just the nature of the ZipCPU, as a result of the design choices that
were made.
 
\subsection{Derived Instructions}
The ZipCPU supports many other common instructions by construction, although
not all of them are single cycle instructions. Tables~\ref{tbl:derived-1}, \ref{tbl:derived-2}, \ref{tbl:derived-3} and~\ref{tbl:derived-4} show how these
other instructions may be implemented on the ZipCPU. Many of these
instructions will have assembly equivalents,
such as the branch instructions, to facilitate working with the CPU.
\begin{table}\begin{center}
\begin{tabular}{p{1.4in}p{1.5in}p{3in}}\\\hline
1132,32 → 1225,41
Mapped & Actual & Notes \\\hline
{\tt ABS Rx}
& \parbox[t]{1.5in}{\tt TST -1,Rx\\NEG.LT Rx}
& Absolute value, depends upon derived NEG.\\\hline
& Absolute value, depends upon the derived {\tt NEG} instruction
below, and so this expands into three instructions total.\\\hline
\parbox[t]{1.4in}{\tt ADD Ra,Rx\\ADDC Rb,Ry}
& \parbox[t]{1.5in}{\tt Add Ra,Rx\\ADD.C \$1,Ry\\Add Rb,Ry}
& Add with carry \\\hline
{\tt BRA.Cond +/-\$Addr}
& \hbox{\tt ADD.cond \$Addr+PC,PC}
& Branch or jump on condition. Works for 18--bit
{\tt BRA.$x$ +/-\$Addr}
& \hbox{\tt ADD.$x$ \$Addr+PC,PC}
& Branch or jump on condition $x$. Works for 18--bit
signed address offsets.\\\hline
{\tt BRA.Cond +/-\$Addr}
& \parbox[t]{1.5in}{\tt LDI \$Addr,Rx \\ ADD.cond Rx,PC}
& Branch/jump on condition. Works for 23 bit address offsets, but
costs a register and an extra instruction. With LDIHI and LDILO
this can be made to work anywhere in the 32-bit address space, but yet
cost an additional instruction still. \\\hline
{\tt BNC PC+\$Addr}
& \parbox[t]{1.5in}{\tt Test \$Carry,CC \\ ADD.Z PC+\$Addr,PC}
& Example of a branch on an unsupported
condition, in this case a branch on not carry \\\hline
{\tt BUSY } & {\tt ADD \$-1,PC} & Execute an infinite loop \\\hline
% {\tt BRA.Cond +/-\$Addr}
% & \parbox[t]{1.5in}{\tt LDI \$Addr,Rx \\ ADD.cond Rx,PC}
% & Branch/jump on condition. Works for 23 bit address offsets, but
% costs a register and an extra instruction. With LDIHI and LDILO
% this can be made to work anywhere in the 32-bit address space, but yet
% cost an additional instruction still. \\\hline
% {\tt BNC PC+\$Addr}
% & \parbox[t]{1.5in}{\tt Test \$Carry,CC \\ ADD.Z PC+\$Addr,PC}
% & Example of a branch on an unsupported
% condition, in this case a branch on not carry \\\hline
{\tt BUSY } & {\tt ADD \$-1,PC} & Execute an infinite loop. This is used
within ZipCPU simulations as the execute simulation on error
instruction. \\\hline
{\tt CLRF.NZ Rx }
& {\tt XOR.NZ Rx,Rx}
& Clear Rx, and flags, if the Z-bit is not set \\\hline
{\tt CLR Rx }
& {\tt LDI \$0,Rx}
& Clears Rx, leaves flags untouched. This instruction cannot be
& Clears Rx, leaving the flags untouched. This instruction cannot be
conditional. \\\hline
{\tt CLR.NZ Rx }
& {\tt BREV.NZ \$0,Rx}
& Clears Rx, leaving the flags untouched. This instruction can be
executed conditionally. The assembler will quietly choose
between {\tt LDI} and {\tt BREV} depending upon the existence
of the condition.\\\hline
{\tt EXCH.W Rx }
& {\tt ROL \$16,Rx}
& Exchanges the top and bottom 16'bit words of Rx \\\hline
1164,7 → 1266,10
{\tt HALT }
& {\tt Or \$SLEEP,CC}
& This only works when issued in interrupt/supervisor mode. In user
mode this is simply a wait until interrupt instruction. \\\hline
mode this is simply a wait until interrupt instruction.
 
This is also used within the simulator as an exit simulation on
success instruction.\\\hline
{\tt INT } & {\tt LDI \$0,CC} & This is also known as a trap instruction\\\hline
{\tt IRET}
& {\tt OR \$GIE,CC}
1171,33 → 1276,41
& Also known as an RTU instruction (Return to Userspace) \\\hline
{\tt JMP R6+\$Offset}
& {\tt MOV \$Offset(R6),PC}
& \\\hline
& Only works for 13--bit offsets. Other offsets require adding the
offset first to R6 before jumping.\\\hline
{\tt LJMP \$Addr}
& \parbox[t]{1.5in}{\tt LOD (PC),PC \\ {\em Address }}
& Although this only works for an unconditional jump, and it only
works in a Von Neumann architecture, this instruction combination makes
for a nice combination that can be adjusted by a linker at a later
time.\\\hline
works in an architecture with a unified instruction and data address
space, this instruction combination makes for a nice combination that
can be adjusted by a linker at a later time.\\\hline
{\tt LJMP.x \$Addr}
& \parbox[t]{1.5in}{\tt LOD.x 2(PC),PC \\ ADD 1,PC \\ {\em Address }}
& Long jump, works for a conditional long jump. \\\hline
\end{tabular}
\caption{Derived Instructions}\label{tbl:derived-1}
\end{center}\end{table}
\begin{table}\begin{center}
\begin{tabular}{p{1.1in}p{1.8in}p{3in}}\\\hline
Mapped & Actual & Notes \\\hline
{\tt LJSR \$Addr }
& \parbox[t]{1.5in}{\tt MOV \$2+PC,R0 \\ LOD (PC),PC \\ {\em Address}}
& Similar to LJMP, but it handles the return address properly.
\\\hline
{\tt JSR PC+\$Offset }
& \parbox[t]{1.5in}{\tt MOV \$1+PC,R0 \\ ADD \$Offset,PC}
& This is similar to the jump and link instructions from other
architectures, save only that it requires a specific link
instruction, also known as the {\tt MOV} instruction on the
instruction, seen here as the {\tt MOV} instruction on the
left.\\\hline
\end{tabular}
\caption{Derived Instructions}\label{tbl:derived-1}
\end{center}\end{table}
\begin{table}\begin{center}
\begin{tabular}{p{1.4in}p{1.5in}p{3in}}\\\hline
Mapped & Actual & Notes \\\hline
{\tt LDI.l \$val,Rx }
& \parbox[t]{1.8in}{\tt LDIHI (\$val$>>$16)\&0x0ffff, Rx \\
LDILO (\$val\&0x0ffff),Rx}
{\tt LDI \$val,Rx }
& \parbox[t]{1.8in}{\tt BREV REV($val$)\&0x0ffff, Rx \\
LDILO ($val$\&0x0ffff),Rx}
& \parbox[t]{3.0in}{Sadly, there's not enough instruction
space to load a complete immediate value into any register.
Therefore, fully loading any register takes two cycles.
The LDIHI (load immediate high) and LDILO (load immediate low)
instructions have been created to facilitate this.
The {\tt LDILO} (load immediate low) instruction has been
created to facilitate this together with {\tt BREV}.
\\
This is also the appropriate means for setting a register value
to an arbitrary 32--bit value in a post--assembly link
1231,30 → 1344,30
instruction order is now backwards, to keep the conditions valid.
That is, LSL sets the carry flag, so if we did this the other way
with Rx before Ry, then the condition flag wouldn't have been right
for an OR correction at the end. \\\hline
for an {\tt OR} correction at the end. \\\hline
\parbox[t]{1.5in}{\tt LSR \$1,Rx \\ LSRC \$1,Ry}
& \parbox[t]{1.5in}{\tt CLR Rz \\
LSR \$1,Ry \\
LDIHI.C \$8000h,Rz \\
BREV.C \$1,Rz \\
LSR \$1,Rx \\
OR Rz,Rx}
& Logical shift right with carry \\\hline
{\tt NEG Rx} & \parbox[t]{1.5in}{\tt XOR \$-1,Rx \\ ADD \$1,Rx} & \\\hline
{\tt NEG.C Rx} & \parbox[t]{1.5in}{\tt MOV.C \$-1+Rx,Rx\\XOR.C \$-1,Rx} & \\\hline
{\tt NOOP} & {\tt NOOP} & While there are many
operations that do nothing, such as MOV Rx,Rx, or OR \$0,Rx, these
operations have consequences in that they might stall the bus if
Rx isn't ready yet. For this reason, we have a dedicated NOOP
instruction. \\\hline
{\tt NOT Rx } & {\tt XOR \$-1,Rx } & \\\hline
{\tt POP Rx }
& \parbox[t]{1.5in}{\tt LOD \$(SP),Rx \\ ADD \$1,SP}
& \\\hline
& Logical shift right with carry. Unlike the shift left, this
approach doesn't extend well to numbers larger than two words. \\\hline
\end{tabular}
\caption{Derived Instructions, continued}\label{tbl:derived-2}
\end{center}\end{table}
\begin{table}\begin{center}
\begin{tabular}{p{1.4in}p{1.5in}p{3in}}\\\hline
\begin{tabular}{p{1.2in}p{1.5in}p{3.2in}}\\\hline
{\tt NEG Rx} & \parbox[t]{1.5in}{\tt XOR \$-1,Rx \\ ADD \$1,Rx} & Negates Rx\\\hline
{\tt NEG.C Rx} & \parbox[t]{1.5in}{\tt MOV.C \$-1+Rx,Rx\\XOR.C \$-1,Rx}
& Conditionally negates Rx\\\hline
{\tt NOT Rx } & {\tt XOR \$-1,Rx } & One's complement\\\hline
{\tt POP Rx }
& \parbox[t]{1.5in}{\tt LOD \$(SP),Rx \\ ADD \$1,SP}
& The compiler avoids the need for this instruction and the similar
{\tt PUSH} instruction when setting up the stack by coalescing all
the stack address modifications into a single instruction at the
beginning of any stack frame.\\\hline
{\tt PUSH Rx}
& \parbox[t]{1.5in}{\hbox{\tt SUB \$1,SP}
\hbox{\tt STO Rx,\$(SP)}}
1261,7 → 1374,7
& Note that for pipelined operation, it helps to coalesce all the
{\tt SUB}'s into one command, and place the {\tt STO}'s right
after each other. Further, to avoid a pipeline stall, the
immediate value for the store must be zero.
immediate value for the first store must be zero.
\\\hline
{\tt PUSH Rx-Ry}
& \parbox[t]{1.5in}{\tt SUB \$$n$,SP \\
1270,13 → 1383,15
STO Ry,\$$\left(n-1\right)$(SP)}
& Multiple pushes at once only need the single subtract from the
stack pointer. This derived instruction is analogous to a similar one
on the Motoroloa 68k architecture, although the Zip Assembler
does not support this instruction (yet). This instruction
on the Motorola 68k architecture, although the Zip Assembler
does not support the combined instruction. This instruction
also supports pipelined memory access.\\\hline
{\tt RESET}
& \parbox[t]{1in}{\tt STO \$1,\$watchdog(R12)\\NOOP\\NOOP}
& This depends upon the peripheral base address being
preloaded into R12.
& \parbox[t]{1in}{\tt STO \$1,\$watchdog(R12)\\BUSY}
& This depends upon the existence of a watchdog peripheral, and the
peripheral base address being preloaded into {\tt R12}. The BUSY
instructions are required because the CPU will continue until the
{\tt STO} has completed.
 
Another opportunity might be to jump to the reset address from within
supervisor mode.\\\hline
1284,19 → 1399,26
& This depends upon the form of the {\tt JSR} given on the previous
page that stores the return address into R0.
\\\hline
{\tt SEX.b Rx }
& \parbox[t]{1.5in}{\tt LSL 24,Rx \\ ASR 24,Rx}
& Signed extend an 8--bit value into a full word.\\\hline
{\tt SEX.h Rx }
& \parbox[t]{1.5in}{\tt LSL 16,Rx \\ ASR 16,Rx}
& Sign extend a 16--bit value into a full word.\\\hline
{\tt STEP Rr,Rt}
& \parbox[t]{1.5in}{\tt LSR \$1,Rr \\ XOR.C Rt,Rr}
& Step a Galois implementation of a Linear Feedback Shift Register, Rr,
using taps Rt \\\hline
{\tt STEP}
& \parbox[t]{1.5in}{\tt OR \$Step|\$GIE,CC}
& Steps a user mode process by one instruction\\\hline
%
%
{\tt SEX.b Rx }
& \parbox[t]{1.5in}{\tt LSL 24,Rx \\ ASR 24,Rx}
& Signed extend a byte into a full word.\\\hline
{\tt SEX.h Rx }
& \parbox[t]{1.5in}{\tt LSL 16,Rx \\ ASR 16,Rx}
& Sign extend a half word into a full word.\\\hline
%
\end{tabular}
\caption{Derived Instructions, continued}\label{tbl:derived-3}
\end{center}\end{table}
\begin{table}\begin{center}
\begin{tabular}{p{1.4in}p{1.5in}p{3in}}\\\hline
{\tt STO.b Rx,\$addr}
& \parbox[t]{1.5in}{\tt %
LDI \$addr,Ra \\
1310,32 → 1432,35
ROL Rb,Rx \\
OR Rx,Ry \\
STO Ry,(Ra) }
& \parbox[t]{3in}{This CPU and it's bus are {\em not} optimized
& \parbox[t]{3in}{This CPU and its bus are {\em not} optimized
for byte-wise operations.
Note that in this example, \$addr is a
byte-wise address, whereas in all of our other examples it is a
32-bit word address. This also limits the address space
of character accesses from 16 MB down to 4MB.F
of character accesses from 16 MB down to 4MB.
Further, this instruction implies a byte ordering,
such as big or little endian.} \\\hline
{\tt SUBR Rx,Ry }
& \parbox[t]{1.5in}{\tt SUB 1+Rx,Ry\\ XOR -1,Ry}
& Ry is set to Rx-Ry, rather than the normal subtract which
sets Ry to Ry-Rx. \\\hline
\parbox[t]{1.4in}{\tt SUB Ra,Rx\\SUBC Rb,Ry}
& \parbox[t]{1.5in}{\tt SUB Ra,Rx\\SUB.C \$1,Ry\\SUB Rb,Ry}
& Subtract with carry. Note that the overflow flag may not be
set correctly after this operation.\\\hline
{\tt SWAP Rx,Ry }
& \parbox[t]{1.5in}{\tt XOR Ry,Rx \\ XOR Rx,Ry \\ XOR Ry,Rx}
& While no extra registers are needed, this example
does take 3-clocks. \\\hline
\end{tabular}
\caption{Derived Instructions, continued}\label{tbl:derived-3}
\end{center}\end{table}
\begin{table}\begin{center}
\begin{tabular}{p{1.4in}p{1.5in}p{3in}}\\\hline
{\tt TRAP \#X}
& \parbox[t]{1.5in}{\tt LDI \$x,R0 \\ AND \~\$GIE,CC }
& \parbox[t]{1.5in}{\tt LDI \$x,R1 \\ AND \textasciitilde\$GIE,CC }
& This works because whenever a user lowers the \$GIE flag, it sets
a TRAP bit within the CC register. Therefore, upon entering the
a TRAP bit within the uCC register. Therefore, upon entering the
supervisor state, the CPU only need check this bit to know that it
got there via a TRAP. The trap could be made conditional by making
the LDI and the AND conditional. In that case, the assembler would
quietly turn the LDI instruction into an LDILO and LDIHI pair,
quietly turn the LDI instruction into a {\tt BREV}/{\tt LDILO} pair,
but the effect would be the same. \\\hline
{\tt TS Rx,Ry,(Rz)}
& \hbox{\tt LDI 1,Rx}
1349,11 → 1474,8
\\\hline
{\tt TST Rx}
& {\tt TST \$-1,Rx}
& Set the condition codes based upon Rx. Could also do a CMP \$0,Rx,
ADD \$0,Rx, SUB \$0,Rx, etc, AND \$-1,Rx, etc. The TST and CMP
approaches won't stall future pipeline stages looking for the value
of Rx. (Future versions of the assembler may shorten this to a
{\tt TST Rx} instruction.)\\\hline
& Set the condition codes based upon Rx without changing Rx.
Equivalent to a CMP \$0,Rx.\\\hline
{\tt WAIT}
& {\tt Or \$GIE | \$SLEEP,CC}
& Wait until the next interrupt, then jump to supervisor/interrupt
1362,85 → 1484,103
\caption{Derived Instructions, continued}\label{tbl:derived-4}
\end{center}\end{table}
 
\section{Interrupt Handling}
The Zip CPU does not maintain any interrupt vector tables. If an interrupt
takes place, the CPU simply switches to interrupt mode. The supervisor code
continues in this interrupt mode from where it left off before, after
\subsection{Interrupt Handling}
The ZipCPU does not maintain any interrupt vector tables. If an interrupt
takes place, the CPU simply switches to from user to supervisor (interrupt)
mode. The supervisor code then continues from where it left off after
executing a return to userspace {\tt RTU} instruction.
 
At this point, the supervisor code needs to determine first whether an
interrupt has occurred, and then whether it is in interrupt mode due to
an exception and handle each case appropriately.
Since the CPU may return from userspace after either an interrupt, a
trap, or an exception, it is up to the supervisor code that handles the
transition to determine which of the three has taken place.
 
\section{Pipeline Stages}
\subsection{Pipeline Stages}
As mentioned in the introduction, and highlighted in Fig.~\ref{fig:cpu},
the Zip CPU supports a five stage pipeline.
the ZipCPU supports a five stage pipeline.
\begin{enumerate}
\item {\bf Prefetch}: Reads instruction from memory and into a cache, if so
configured. This
stage is actually pipelined itself, and so it will stall if the PC
ever changes. Stalls are also created here if the instruction isn't
\item {\bf Prefetch}: Reads instructions from memory. If the CPU has been
configured with a cache, the cache has been integrated into the
prefetch. Stalls are also created here if the instruction isn't
in the prefetch cache.
 
The Zip CPU supports one of three prefetch methods, depending upon a
flag set at build time within the {\tt cpudefs.v} file. The simplest
The ZipCPU supports one of three prefetch methods, depending upon the
flags set at build time within the {\tt cpudefs.v} file.
 
The simplest
is a non--cached implementation of a prefetch. This implementation is
fairly small, and ideal for users of the Zip CPU who need the extra
fairly small, and ideal for users of the ZipCPU who need the extra
space on the FPGA fabric. However, because this non--cached version
has no cache, the maximum number of instructions per clock is limited
to about one per five.
to about one per eight--depending upon the bus/memory delay.
This prefetch option is set by leaving the {\tt OPT\_SINGLE\_FETCH}
line uncommented within the {\tt cpudefs.v} file. Using this option
will also turn off the ZipCPU pipeline.
 
The second prefetch module is a pipelined prefetch with a cache. This
module tries to keep the instruction address within a window of valid
instruction addresses. While effective, it is not a traditional
cache implementation. One unique feature of this cache implementation,
however, is that it can be cleared in a single clock. A disappointing
feature, though, was that it needs an extra internal pipeline stage
The second prefetch module is a non--traditional pipelined prefetch
with a cache. This module tries to keep the instruction address
within a window of valid instruction addresses. While effective, it
is not a traditional cache implementation. A disappointing feature of
this implementation is that it needs an extra internal pipeline stage
to be implemented.
 
The third prefetch and cache module implements a more traditional cache.
While the resulting code tends to be twice as fast as the pipelined
cache architecture, this implementation uses a large amount of
distributed FPGA RAM to be successful. This then inflates the Zip CPU's
FPGA usage statistics.
The third prefetch and cache module implements a more traditional
cache. This cache provides for the fastest CPU speed. The only
drawback is that, when a cache line is loading, the CPU will be stalled
until the cache is completely loaded.
 
\item {\bf Decode}: Decodes an instruction into OpCode, register(s) to read,
and immediate offset. This stage also determines whether the flags
will be set or whether the result will be written back.
\item {\bf Decode}: Decodes an instruction into it's OpCode, register(s) to
read, condition code, and immediate offset. This stage also
determines whether the flags will be read or set, whether registers
will be read (and hence the pipeline may need to stall), or whether the
result will be written back. In many ways, simplifying the CPU also
meant simplifying this pipeline stage and hence the instruction set
architecture.
 
\item {\bf Read Operands}: Read registers and apply any immediate values to
them. There is no means of detecting or flagging arithmetic overflow
or carry when adding the immediate to the operand. This stage will
stall if any source operand is pending.
\item {\bf Read Operands}: Read from the register file and applies any
immediate values to the result. There is no means of detecting or
flagging arithmetic overflow or carry when adding the immediate to the
operand. This stage will stall if any source operand is pending
and the immediate value is non--zero.
 
\item Split into one of four tracks: An {\bf ALU} track which will accomplish
a simple instruction, the {\bf MemOps} stage which handles {\tt LOD}
(load) and {\tt STO} (store) instructions, the {\bf divide} unit,
and the {\bf floating point} unit.
\item At this point, the processing flow splits into one of four tracks: An
{\bf ALU} track which will accomplish a simple instruction, the
{\bf MemOps} stage which handles {\tt LOD} (load) and {\tt STO}
(store) instructions, the {\bf divide} unit, and the
{\bf floating point} unit.
\begin{itemize}
\item Loads will stall instructions in the decode stage until the
entire pipeline until complete, lest a register be read in
the read operands stage only to be updated unseen by the
Load.
\item Condition codes are available upon completion of the ALU,
divide, or FPU stage.
\item Loads will stall instructions in the read operands stage until the
entire memory is complete, lest a register be read only to be
updated unseen by the Load.
\item Condition codes are set upon completion of the ALU, divide,
or FPU stage. (Memory operations do not set conditions.)
\item Issuing a non--pipelined memory instruction to the memory unit
while the memory unit is busy will stall the entire pipeline.
while the memory unit is busy will stall the entire pipeline
until the memory unit is idle and ready to accept another
instruction.
\end{itemize}
\item {\bf Write-Back}: Conditionally write back the result to the register
set, applying the condition. This routine is quad-entrant: either the
ALU, the memory, the divide, or the FPU may write back a register.
The only design rule is that no more than a single register may be
written back in any given clock.
set, applying the condition and any special CC logic. This routine is
quad-entrant: either the ALU, the memory, the divide, or the FPU may
commit a result. The only design rule is that no more than a single
register may be written in any given clock cycle.
 
This is also the stage where any special condition code logic takes
place.
\end{enumerate}
 
The Zip CPU does not support out of order execution. Therefore, if the memory
The ZipCPU does not support out of order execution. Therefore, if the memory
unit stalls, every other instruction stalls. The same is true for divide or
floating point instructions--all other instructions will stall while waiting
for these to complete. Memory stores, however, can take place concurrently
with non--memory operations, although memory reads (loads) cannot.
with non--memory operations, although memory reads (loads) cannot. This is
likely to change with the integration of an memory management unit (MMU), in which case a store
instruction must stall the CPU until it is known whether or not the store
address can be mapped by the MMU.
 
\section{Pipeline Stalls}
% \subsection{Instruction Cache}
% \subsection{Data Cache}
 
\subsection{Pipeline Stalls}
The processing pipeline can and will stall for a variety of reasons. Some of
these are obvious, some less so. These reasons are listed below:
\begin{itemize}
1455,7 → 1595,8
fill before instruction execution can continue.
 
\item While waiting for the pipeline to load following any taken branch, jump,
return from interrupt or switch to interrupt context (4 stall cycles)
return from interrupt or switch to interrupt context (4 stall cycles,
minimum)
 
Fig.~\ref{fig:bcstalls}
\begin{figure}\begin{center}
1470,12 → 1611,12
for the four stalls. (Were the {\tt pipefetch} cache chosen, there would
be another stall internal to the {\tt pipefetch} cache.)
 
The Zip CPU handles the {\tt ADD \$X,PC} and
{\tt LDI \$X,PC} instructions specially, however. These instructions, when
not conditioned on the flags, can execute with only a single stall cycle,
such as is shown in Fig.~\ref{fig:branch}.\footnote{Note that when using the
{\tt pipefetch} cache, this requires an additional stall cycle due to that
cache's implementation.}
The decode stage can handle the {\tt ADD \$X,PC}, {\tt LDI \$X,PC}, and
{\tt LOD (PC),PC} instructions specially, however, when {\tt EARLY\_BRANCHING}
is enabled. These instructions, when
not conditioned on the flags, can execute with only a single stall cycle (two
for the {\tt LOD(PC),PC} instruction),
such as is shown in Fig.~\ref{fig:branch}.
\begin{figure}\begin{center}
\includegraphics[width=4in]{../gfx/bra.eps} %0.4in per clock
\caption{An expedited branch costs a single stall cycle}\label{fig:branch}
1501,8 → 1642,9
scheduled into the stall slot.
 
This is also the reason why, when setting up a stack frame, the top of the
stack frame is used first: it eliminates this stall cycle. Hence, to save
registers at the top of a procedure, one would write:
stack frame is used first: it eliminates this stall cycle.\footnote{This only
applies if there is no local memory to allocate on the stack as well.} Hence,
to save registers at the top of a procedure, one would write:
\begin{enumerate}
\item\ {\tt SUB 2,SP}
\item\ {\tt STO R1,(SP)}
1542,7 → 1684,7
\item\ {\tt OPCODE I+RA,RB}
\end{enumerate}
 
Remember, the Zip CPU does not support out of order execution. Therefore,
Remember, the ZipCPU does not support out of order execution. Therefore,
anytime the memory unit becomes busy both the memory unit and the ALU must
stall until the memory unit is cleared. This is illustrated in
Fig.~\ref{fig:memrd},
1593,109 → 1735,175
stall while waiting for it to complete before the load instruction can
start.
 
The Zip CPU does have the capability of supporting pipelined memory access,
but only under the following conditions: all accesses within the pipeline
must all be reads or all be writes, all must use the same register for their
address, and there can be no stalls or other instructions between pipelined
memory access instructions. Further, the offset to memory must be increasing
by one address each instruction. These conditions work well for saving or
storing registers to the stack. Indeed, if you noticed, both
Fig.~\ref{fig:memrd} and Fig.~\ref{fig:memwr} illustrated pipelined memory
accesses.
The ZipCPU has the capability of supporting a form of burst memory access,
often called pipelined memory access within this document due to its use of
the Wishbone B4 pipelined access mode.
When using this mode, the CPU may issue multiple loads or stores at a time,
to the extent that all but the first take only a single clock. Doing this
requires several conditions to be true:
\begin{enumerate}
\item Aall accesses within the burst must all be reads or all be writes,
\item All must use the same base register for their address, and
\item There can be no stalls or other instructions between memory access instructions within the burst.
\item Further, the immediate offset to memory must be either indentical or
increasing by one address each instruction.
\end{enumerate}
These conditions work well for saving or storing registers to the stack in a
burst operation. Indeed, if you noticed, both Fig.~\ref{fig:memrd} and
Fig.~\ref{fig:memwr} illustrated pipelined memory accesses. Beyond saving and
restoring registers to the stack, the compiler does not optimize well (yet)
for using this burst mode.
 
\end{itemize}
 
% \subsection{Debug}
 
\chapter{Peripherals}\label{chap:periph}
\section{External Architecture}
 
While the previous chapter describes a CPU in isolation, the Zip System
includes a minimum set of peripherals as well. These peripherals are shown
in Fig.~\ref{fig:zipsystem}
Having now described the CPU registers, instructions, and instruction formats,
we now turn our attention to how the CPU interacts with the rest of the world.
Specifically, we shall discuss how the bus is implemented, and the memory
model assumed by the CPU.
 
\subsection{Simplified Wishbone Bus}\label{ssec:bus}
The bus architecture of the ZipCPU is that of a simplified, pipelined, WISHBONE
bus built according to the B4 specification. Several changes have been made to
simplify this bus. First, all unnecessary ancillary information has been
removed. This includes the retry, tag, lock, cycle type indicator, and burst
indicator signals. It also includes the select lines which would enable the
CPU to act on less than 32--bit words. As a result all operations on the bus
are 32--bit operations. The bus is neither little endian nor big endian. For
this reason, all words are 32--bits. All instructions are also 32--bits wide.
Everything has been built around the 32--bit word. Even the byte size (the
size of the minimum addressable unit) is 32--bits. Second, we insist that all
accesses be pipelined, and simplify that further by insisting that pipelined
accesses not cross peripherals---although we leave it to the user to keep that
from happening in practice. Finally, we insist that the wishbone strobe line
be zero any time the cycle line is inactive. This makes decoding simpler
in slave logic: a transaction is initiated whenever the strobe line is high
and the stall line is low. For those peripherals that do not generate stalls,
only the strobe line needs to be tested for access. The transaction completes
whenever either the ACK or the ERR lines go high.
 
\subsection{Memory Model}\label{ssec:memory}
The memory model of the ZipCPU is that of a uniform 32--bit address space.
The CPU knows nothing about which addresses reference on--chip or off-chip
memory, or even which reference peripherals. Indeed, there is no indication
within the CPU if a particular piece of memory can be cached or not, save that
the CPU assumes any and all instruction words can be cached.
 
The one exception to this rule revolves around addresses beginning with
{\tt 2'b11} in their high order word. These addresses are used to access a
variety of optional peripherals that will be discussed more in
Sec.~\ref{sec:zipsys}, but that are only present within the {\tt ZipSystem}.
When used with the bare {\tt ZipBones}, these addresses will cause a bus error.
 
The prefetch cache currently has no means of detecting an instruction that
was changed, save by clearing the instruction cache. This may be necessary
when loading programs into previously used memory, or when creating
self--modifying code.
 
Should the memory management unit (MMU) be integrated into the ZipCPU, the MMU
will be able to be configured to instruct the ZipCPU as to which addresses may
be cached and which not.
 
This topic is discussed further in the linker section, Sec.~\ref{sec:ld-mem}
of the ABI chapter, Chap.~\ref{chap:abi}.
 
% \subsection{Measured Performance}\label{sec:perf}
 
\subsection{ZipSystem}\label{sec:zipsys}
 
While the previous chapter describes a CPU in isolation, the ZipSystem
includes a small minimum set of peripherals that can be tightly integrated into
the CPU. These peripherals are shown in Fig.~\ref{fig:zipsystem}
\begin{figure}\begin{center}
\includegraphics[width=3.5in]{../gfx/system.eps}
\caption{Zip System Peripherals}\label{fig:zipsystem}
\caption{ZipSystem Peripherals}\label{fig:zipsystem}
\end{center}\end{figure}
and described here. They are designed to make
the Zip CPU more useful in an Embedded Operating System environment.
the ZipCPU more useful in an Embedded Operating System environment.
 
\section{Interrupt Controller}\label{sec:pic}
\subsubsection{Interrupt Controller}\label{sec:pic}
 
Perhaps the most important peripheral within the Zip System is the interrupt
controller. While the Zip CPU itself can only handle one interrupt, and has
Perhaps the most important peripheral within the ZipSystem is the interrupt
controller. While the ZipCPU itself can only handle one interrupt, and has
only the one interrupt state: disabled or enabled, the interrupt controller
can make things more interesting.
 
The Zip System interrupt controller module supports up to 15 interrupts, all
controlled from one register. Bit~31 of the interrupt controller controls
overall whether interrupts are enabled (1'b1) or disabled (1'b0). Bits~16--30
control whether individual interrupts are enabled (1'b1) or disabled (1'b0).
Bit~15 is an indicator showing whether or not any interrupt is active, and
bits~0--15 indicate whether or not an individual interrupt is active.
The ZipSystem interrupt controller module supports up to 15 interrupts, all
controlled from one register. Further, it has been designed so that individual
interrupts can be enabled or disabled individually without having any knowledge
of the rest of the controller setting. To enable an interrupt, write to the
register with the high order global enable bit set and the respective interrupt
enable bit set. No other bits will be affected. To disable an interrupt,
write to the register with the high order global enable bit cleared and the
respective interrupt enable bit set. To clear an interrupt, write a `1' to
that interrupt's status pin. A zero written to the register has the sole
effect of disabling the master interrupt enable bit.
 
The interrupt controller has been designed so that bits can be controlled
individually without having any knowledge of the rest of the controller
setting. To enable an interrupt, write to the register with the high order
global enable bit set and the respective interrupt enable bit set. No other
bits will be affected. To disable an interrupt, write to the register with
the high order global enable bit cleared and the respective interrupt enable
bit set. To clear an interrupt, write a `1' to that interrupts status pin.
Zero's written to the register have no affect, save that a zero written to the
master enable will disable all interrupts.
 
As an example, suppose you wished to enable interrupt \#4. You would then
write to the register a {\tt 0x80100010} to enable interrupt \#4 and to clear
any past active state. When you later wish to disable this interrupt, you would
write a {\tt 0x00100010} to the register. As before, this both disables the
write a {\tt 0x00100010} to the register. This both disables the
interrupt and clears the active indicator. This also has the side effect of
disabling all interrupts, so a second write of {\tt 0x80000000} may be necessary
to re-enable any other interrupts.
 
The Zip System currently hosts two interrupt controllers, a primary and a
secondary. The primary interrupt controller has one (or more) interrupt line(s)
which may come from an external interrupt source, and one interrupt line from
the secondary controller. Other primary interrupts include the system timers,
the jiffies interrupt, and the manual cache interrupt. The secondary interrupt
controller maintains an interrupt state for all of the processor accounting
counters.
The ZipSystem hosts two interrupt controllers: a primary and a secondary. The
primary interrupt controller is the one that interrupts the CPU. It has
six local interrupt lines, the rest coming from external interrupt sources.
One of those interrupt lines to the primary controller comes from the secondary
interrupt controller. This controller maintains an interrupt state for the
process accounting counters, and any other external interrupts that didn't fit
into the primary interrupt controller.
 
\section{Counter}
As a word of caution, because the interrupt controller is an external
peripheral, and because memory writes take place concurrently with any following
instructions, any attempt to clear interrupts on one instruction followed by
an immediate Return to Userspace ({\tt RTU}) instruction, may not have the
effect of having interrupts cleared before the {\tt RTU} instruction executes.
 
\subsubsection{Counter}
 
The Zip Counter is a very simple counter: it just counts. It cannot be
halted. When it rolls over, it issues an interrupt. Writing a value to the
counter just sets the current value, and it starts counting again from that
value.
 
Eight counters are implemented in the Zip System for process accounting.
Eight counters are implemented in the ZipSystem for process accounting if
the {\tt INCLUDE\_ACCOUNTING\_COUNTERS} define is set within {\tt cpudefs.v}.
Four of those measure the performance of the system as a whole, four are
used for measuring user CPU usage.
This may change in the future, as nothing as yet uses these counters.
 
\section{Timer}
\subsubsection{Timer}
 
The Zip Timer is also very simple: it simply counts down to zero. When it
transitions from a one to a zero it creates an interrupt.
The Zip Timer is also very simple: it is a 31--bit counter that simply counts
down to zero. When it transitions from a one to a zero it creates an interrupt.
 
Writing any non-zero value to the timer starts the timer. If the high order
bit is set when writing to the timer, the timer becomes an interval timer and
reloads its last start time on any interrupt. Hence, to mark seconds, one
might set the timer to 100~million (the number of clocks per second), and
set the high bit. Ever after, the timer will interrupt the CPU once per
second (assuming a 100~MHz clock). This reload capability also limits the
maximum timer value to $2^{31}-1$ (about 21~seconds using a 100~MHz clock),
rather than $2^{32}-1$.
might set the 31--bits of the timer to the number of clocks per second and the
top bit to one. Ever after, the timer will interrupt the CPU once per
second--until a non--interrupt interval is set in the timer. This reload
capability also limits the maximum timer value to $2^{31}-1$, rather than
$2^{32}-1$.
 
\section{Watchdog Timer}
\subsubsection{Watchdog Timer}
 
The watchdog timer is no different from any of the other timers, save for one
critical difference: the interrupt line from the watchdog
timer is tied to the reset line of the CPU. Hence writing a `1' to the
watchdog timer will always reset the CPU.
To stop the Watchdog timer, write a `0' to it. To start it,
The watchdog timer has only two differences from the of the other timers.
The first difference is that it is a one--shot timer. The second difference,
though, is critical: the interrupt line from the watchdog timer is tied to the
reset line of the CPU. Hence writing a `1' to the watchdog timer will always
reset the CPU. To stop the Watchdog timer, write a `0' to it. To start it,
write any other number to it---as with the other timers.
 
While the watchdog timer supports interval mode, it doesn't make as much sense
as it did with the other timers.
 
\section{Bus Watchdog}
There is an additional watchdog timer on the Wishbone bus. This timer,
\subsubsection{Bus Watchdog}
There is an additional watchdog timer on the Wishbone bus of the ZipSystem.
This timer,
however, is hardware configured and not software configured. The timer is
reset at the beginning of any bus transaction, and only counts clocks during
such bus transactions. If the bus transaction takes longer than the number
1708,7 → 1916,7
implementation of the fundamental timer described above--stripped down
for simplicity.
 
\section{Jiffies}
\subsubsection{Jiffies}
 
This peripheral is motivated by the Linux use of `jiffies' whereby a process
can request to be put to sleep until a certain number of `jiffies' have
1726,21 → 1934,26
and wake up the process whose timer had expired.
 
Indeed, the Jiffies register is nothing more than a glorified counter with
an interrupt. Unlike the other counters, the Jiffies register cannot be set.
an interrupt. Unlike the other counters, the internal Jiffies counter can only
be read, never set.
Writes to the jiffies register create an interrupt time. When the Jiffies
register later equals the value written to it, an interrupt will be asserted
and the register then continues counting as though no interrupt had taken
place.
 
Finally, if the new value written to the Jiffies register is within the past
$2^{31-1}$ clock ticks, the Jiffies register will immediately cause an interrupt
and otherwise ignore the new request.
 
The purpose of this register is to support alarm times within a CPU. To
set an alarm for a particular process $N$ clocks in advance, read the current
Jiffies value, and $N$, and write it back to the Jiffies register. The
Jiffies value, add $N$, and write it back to the Jiffies register. The
O/S must also keep track of values written to the Jiffies register. Thus,
when an `alarm' trips, it should be removed from the list of alarms, the list
should be resorted, and the next alarm in terms of Jiffies should be written
to the register--possibly for a second time.
 
\section{Direct Memory Access Controller}
\subsubsection{Direct Memory Access Controller}
 
The Direct Memory Access (DMA) controller can be used to either move memory
from one location to another, to read from a peripheral into memory, or to
1748,9 → 1961,12
since the DMA controller can issue (and does issue) pipeline wishbone accesses,
any DMA memory move will by nature be faster than a corresponding program
accomplishing the same move. To put this to numbers, it may take a program
18~clocks per word transferred, whereas this DMA controller can move one
word in two clocks--provided it has bus access. (The CPU gets priority over
the bus.)
running on the CPU 18~clocks per word transferred, whereas this DMA controller
can move one word in eight clocks--provided it has bus
access\footnote{The pipeline cost of the DMA controller, including setup cost,
is a minimum of $14+2N$ clocks.} (The CPU gets priority over the bus, but once
bus access is granted to the DMA peripheral, it will not be revoked mid--read
or mid--write.)
 
When copying memory from one location to another, the DMA controller will
copy in units of a given transfer length--up to 1024 words at a time. It will
1758,7 → 1974,7
destination address from that buffer.
 
When coupled with a peripheral, the DMA controller can be configured to start
a memory copy when any interrupt line going high. Further, the controller can
a memory copy when any interrupt line goes high. Further, the controller can
be configured to issue reads from (or to) the same address instead of
incrementing the address at each clock. The DMA completes once the total
number of items specified (not the transfer length) have been transferred.
1766,62 → 1982,473
In each case, once the transfer is complete and the DMA unit returns to
idle, the DMA will issue an interrupt.
 
% \subsubsection{Memory Management Unit}
 
\chapter{Operation}\label{chap:ops}
\section{Debug Interface}\label{sec:debug}
 
The Zip CPU, and even the Zip System, is not a System on a Chip (SoC). It
needs to be connected to its operational environment in order to be used.
Specifically, some per system adjustments need to be made:
The ZipCPU supports an external debug port. Access to the port is the
same as accessing a two register peripheral on a wishbone bus, so the basic
interface is fairly simple. Using this interface, it is possible to both
control the CPU, as well as read register values and current status from the
CPU.
 
While a more detailed discussion will be reserved for Sec.~\ref{sec:reg-debug},
here we'll just discuss how it is put together. The debug interface allows
a controller access to the CPU reset line, and a halt line. By raising the
reset line, the CPU will be caused to clear it's cache, to clear any internal
exception or error conditions, and then to start execution at the
{\tt RESET\_ADDRESS}--just like a normal reboot. In a similar fashion, the
debug interface allows you to control the {\tt cpu\_halt} line into the
CPU. Holding this line high will hold the CPU in an externally halted state.
Toggling the line low for one clock allows one to step the CPU by one
instruction. Lowering the line causes the CPU to go. A final control wire,
controlled by the debug interface, will force the CPU to clear its cache.
All of these control wires are set or cleared from the debug control register.
 
The two debug command registers also make it possible to read and write
all 32 registers within the CPU. In this fashion, a debugger can halt the
CPU, investigate its state, and even modify registers so as to have the
CPU restart from a different state.
 
Finally, without halting the CPU, the debug controller can read from any
single register, and it can see if the CPU is still actively running, whether
it is in user or supervisor modes, and whether or not it is sleeping. This
alone is useful for detecting deadlocks or other difficult problems.
 
\chapter{Application Binary Interface}\label{chap:abi}
 
This chapter discusses not the CPU itself, but rather how the GCC and binutils
toolchains have been configured to support the ZipCPU.
 
% ELF Format
% Stack:
% R13 is the stack register.
% The stack grows downward.
% Memory at the current stack pointer is allocated.
% Hence, a PUSH is : SUB 1,SP; STO Rx,(SP)
% Heap:
% In general, not yet implemented.
% A less than adequate Heap has been implemented as a pointer, from which
% malloc requests simply decrement it. Free's are NOOPs, leaving
% allocated memory allocated forever.
 
\section{Executable File Format}\label{sec:abi-elf}
ZipCPU executable files are stored in the Executable and Linkable Format
(ELF), prior to being placed in flash, or whatever memory they will be
executed from. All addresses within this format are ZipCPU addresses,
referencing 32--bit quantities, whereas all offsets internal to the ELF file
represent 8--bit quantities. Thus, when running the {\tt zip-objdump} utility
on a ZipCPU ELF file, the addresses are properly set.
 
The ZipCPU does not (yet) have a dynamic linker/loader. All linking is
currently static, and done prior to run time.
 
\section{Stack}\label{sec:abi-stack}
Although nothing in the hardware requires this, the compiler back end
implementation uses {\tt R13} (also known as the {\tt SP} register) as a stack
register, and grows the stack from
high addresses to lower addresses. That means that the stack will usually
start out set to a very large value, such as one past the last RAM address,
and it will grow to lower and lower values--hopefully never mixing with the
heap. Memory at the current stack position is assumed to be allocated.
 
When creating a stack frame for a function, the compiler will subtract
the size of the stack frame from the stack register. It will then store
any registers used by the function, from {\tt R5} to {\tt R12} (including
the link register {\tt R0}) onto offsets given by the stack pointer plus a
constant. If a frame pointer is used, the compiler uses {\tt R12} (or {\tt FP})
for this purpose. The frame pointer is set by moving the stack pointer
plus an offset into {\tt FP}. This {\tt MOV} instruction effectively limits
the size of any individual stack frame to $2^{12}-1$ words.
 
Once a subroutine is complete, the frame is unwound. If the frame pointer,
{\tt FP} was used, then {\tt FP} is copied directly to the stack pointer,
{\tt SP}. Registers are restored, starting with {\tt R0} all the way to
{\tt R12} ({\tt FP}). This also restores, and obliterates, the subroutine
frame pointer. Once complete, a value is added to the stack pointer to return
it to its original value, and a jump is made to the value located within
{\tt R0}.
 
\section{Relocations}\label{sec:abi-reloc}
 
The ZipCPU binutils back end supports two several relocations, although the
two most common are the 32--bit relocations for register load and long jump.
 
The first of these is for loading an arbitrary 32--bit value into a register.
Such instructions are broken into a pair of {\tt BREV} and {\tt LDILO}
instructions, and once the value of the parameter is known their immediates
are filled in.
 
The second type of 32--bit relocation is for jumps to arbitrary addresses.
These jumps are supported by the \hbox{\tt LOD (PC),PC} instruction, followed
by the 32--bit address to be filled in later by the linker. If the jump is
conditional, then a conditional \hbox{\tt LOD.$x$ 1(PC),PC} instruction is
used, followed by a {\tt BRA 1(PC),PC} and then the 32--bit relocation value.
 
If the branch distance is known and within reach, branches will be implemented
with {\tt ADD \#,PC} instructions, possibly conditional, as necessary.
 
While other relocations are supported, they tend not to be used nearly as much
as these two.
 
\section{Call format}\label{sec:abi-jsr}
 
One feature of the ZipCPU is that it has no JSR instruction. Jumps to
subroutine's therefore take three assembly instructions:
The first is a {\tt MOV .Lcall\#\#(PC),R0}, which places the return address
into R0. {\tt .Lcall\#\#} in this case is a label, where \#\# is a unique
number filled in by the compiler. This instruction is followed by a
{\tt BRA subroutine} instruction. Finally, the third assembly ``instruction''
of any call sequence is the label {\tt .Lcall\#\#}.
 
While this works well in practice, GCC's implementation prevents such things
as {\tt JSR}'s followed by {\tt BRA}'s from being combined together.
 
Finally, the first five operands passed to the subroutine will be placed into
registers R1--R5. Any additional operands are placed upon the stack.
 
\section{Built-ins}\label{sec:abi-builtin}
The ZipCPU ABI supports the a number of built in functions. The compiler
maps these functions directly to assembly language equivalents, essentially
providing the C~programmer with access to several assembly language
instructions. These are:
\begin{enumerate}
\item The Zip System depends upon an external 32-bit Wishbone bus. This
must exist, and must be connected to the Zip CPU for it to work.
\item The Zip System needs to be told of its {\tt RESET\_ADDRESS}. This is
the program counter of the first instruction following a reset.
\item To conserve logic, you'll want to set the {\tt ADDRESS\_WIDTH} parameter
to the number of address bits on your wishbone bus.
\item Likewise, the {\tt LGICACHE} parameter sets the number of bits in
the instruction cache address. This means that the instruction cache
will have $2^{\mbox{\tiny\tt LGICACHE}}$ locations within it.
\item If you want the Zip System to start up on its own, you will need to
set the {\tt START\_HALTED} parameter to zero. Otherwise, if you
wish to manually start the CPU, that is if upon reset you want the
CPU start start in its halted, reset state, then set this parameter to
one. This latter configuration is useful for a CPU that should be
idle (i.e. halted) until given an explicit instruction from somewhere
else to start.
\item The third parameter to set is the number of interrupts you will be
providing from external to the CPU. This can be anything from one
to sixteen, but it cannot be zero. (Set this to 1 and wire the single
interrupt line to a 1'b0 if you do not wish to support any external
interrupts.)
\item Finally, you need to place into some wishbone accessible address, whether
RAM or (more likely) ROM, the initial instructions for the CPU.
\item {\tt zip\_bitrev(int)} reverses the bits in the given integer, returning
the result. This utilizes the internal {\tt BREV} instruction, and is
designed to be used with FFT's as necessary.
\item {\tt zip\_busy()} executes an {\tt ADD -1,PC} function, essentially
forcing the CPU into a very tight infinite loop.
\item {\tt zip\_cc()} returns the value of the current CC register. This may
be used within both user and supervisor code to determine in which
mode the CPU is within.
\item {\tt zip\_halt()} executes an \hbox{\tt OR \$SLEEP,CC} instruction to
place the processor to sleep. If the processor is in supervisor mode,
this halt's the processor.
\item {\tt zip\_rtu()} executes an \hbox{\tt OR \$GIE,CC} instruction. This
will place the CPU into user mode, and has no effect if the CPU is
already in user mode.
\item {\tt zip\_step()} executes an \hbox{\tt OR \$STEP|\$GIE,CC} instruction.
This will place the CPU into user mode in order to step one instruction,
and then return to supervisor mode.
It has no effect if the CPU is already in user mode.
\item {\tt zip\_system()} executes an \hbox{\tt AND \textasciitilde\$GIE,CC}
instruction to return the CPU to supervisor mode. This essentially
executes a trap, setting the trap bit for the supervisor to examine.
What this instruction does not do is arrange for the trap arguments to
be placed into the registers {\tt R1} through {\tt R5}. Since this is
a wholly inadequate solution, a function call may be made to an
assembly routine that executes a trap if necessary.
\item {\tt zip\_wait()} executes a \hbox{\tt \$SLEEP|\$GIE,CC} instruction.
Unlike {\tt zip\_halt()}, this {\tt zip\_wait()} instruction places
the CPU into a wait state regardless of whether or not the CPU is
in supervisor mode or not. When this function, i.e. instruction,
completes, it will leave the CPU in supervisor mode upon an interrupt
having taken place.
 
You may wish to set the user program counter prior to this instruction,
as the prefetch unit will try to load instructions from the address
contained within the user program counter. Attempts to read from
addresses with sideeffects may not produce the desired outcome.
However, once that cache fails (or succeeds), the CPU will have been
put to sleep and will do no more.
 
\item {\tt zip\_restore\_context(context *)} inserts the 32~assembly
instructions necessary to copy all sixteen user registers to a memory
region pointed to by the given context pointer, starting with {\tt uR0}
on up to {\tt uPC}.
 
\item {\tt zip\_save\_context(context *)} inserts the 32~assembly instructions
necessary to copy all sixteen user registers to a memory region pointed
to by the given context pointer argument, starting
with {\tt uR0} on up to {\tt uPC}.
\item {\tt zip\_ucc()}, returns the value of the user CC register.
\end{enumerate}
If you have enabled your CPU to start automatically, then upon power up the
CPU will immediately start executing your instructions, starting at the given
{\tt RESET\_ADDRESS}.
 
This is, however, not how I have used the Zip CPU. I have instead used the
Zip CPU in a more controlled environment. For me, the CPU starts in a
halted state, and waits to be told to start. Further, the RESET address is a
location in RAM. After bringing up the board I am using, and further the
bus that is on it, the RAM memory is then loaded externally with the program
I wish the Zip System to run. Once the RAM is loaded, I release the CPU.
The CPU then runs until either its halt condition or an exception occurrs in
supervisor mode, at which point its task is complete.
% Builtin functions:
% zip_break();
% zip_idle();
% zip_syscall(a,b,c,d)
%
\section{Linker Scripts}\label{sec:ld}
The ZipCPU makes no assumptions about its memory layout. The result, though,
is that the memory layout of a given project is board specific. This
is accomplished via a board specific linker script. This section will discuss
some of the specifics of a ZipCPU linker script.
 
Eventually, I intend to place an operating system onto the ZipSystem, I'm
just not there yet.
Because the ZipCPU uses a modified binutils package as part of its tool chain,
the format for this linker script is defined by the GNU LD project within
binutils. Further details on that format may be found within the GNU LD
documentation within the binutils package.
 
The rest of this chapter examines some common programming models, and how they
might be applied to the Zip System, and then finish with a couple of examples.
This discussion will focus on those parts of the script specific to the ZipCPU.
 
\subsection{Memory Types}\label{sec:ld-mem}
Of the FPGA boards that the ZipCPU has been applied to, most of them have some
combination of three types of memory: flash, block RAM, and Synchronous
Dynamic RAM (SDRAM). Of these three, only the flash is non--volatile. The
block RAM is the fastest, and the SDRAM the largest. While other memory types
are available, such as files on an external media such as an SD card or a
network drive, these three types have so far been sufficient for our purposes.
 
To support these memories, the linker script has three memory lines identifying
where each memory exists on the bus, the size of the memory, and any protections
associated with it. For example,
\begin{eqnarray*}
\mbox{blkram (wx) : ORIGIN = 0x0008000, LENGTH = 0x0008000}
\end{eqnarray*}
specifies that there is a region of memory, called blkram, that can be read and
written, and that programs can execute from. This section starts at address
{\tt 0x8000} and extends for another {\tt 0x8000} words. The other memories
are defined in a similar manner, with names {\tt flash} and {\tt sdram}.
 
Following the memory section, three specific symbols are defined:
{\tt \_flash}, defining the beginning of flash memory,
{\tt \_blkram}, defining the beginning of on--chip block RAM,
and
{\tt \_sdram}, defining the beginning of SDRAM.
These symbols are used to make the bootloader's task easier.
 
\subsection{The Entry Function}\label{sec:ld-entry}
The ZipCPU has, as a parameter, a {\tt RESET\_ADDRESS}. It is important
that this address contain a valid instruction (or more), since this is the
first instruction the ZipCPU will execute. Traditionally, this address is also
the first address in instruction memory as well.
 
To make this happen, the ZipCPU defines two additional segments: the
{\tt .start} and the {\tt .boot} segments. The {\tt .start} segment is to
have nothing in it but the very initial startup code. This code needs to run
from flash (or other ROM). By placing this segment at the very beginning of
the ZipCPU's flash address space, and in particular at the first valid flash
address, the ZipCPU will boot from this address. This is the purpose of the
{\tt .start} section.
 
The {\tt .boot} section has a similar purpose. This section includes anything
associated with the bootloader. It is a special section because, when loading
from flash, the bootloader {\em cannot} be placed in RAM, but must be placed
in flash--since it is the code that loads things from flash into RAM.
 
It may also make sense to place any code executed once only within flash as
well. Such code may run slower than the main system code, but by leaving it in
flash it can be kept from consuming any higher speed RAM. To do this, place
this other code into the {\tt .boot} section.
 
You may also find that large data structures that are best left in flash
can also be placed into this {\tt .boot} section as well for that purpose.
 
\subsection{Bootloader Tags}\label{sec:ld-boot}
 
The bootloader needs to know a couple things from the linker script. It needs
to know what code/data to copy to block RAM from the flash, what code/data to
copy to SDRAM, and finally what initial data area needs to be zeroed. Four
additional pointers, set within a linker script, can define these regions.
 
\begin{enumerate}
\item {\tt \_kernel\_image\_start}
 
This is the first location in flash containing data that the bootloader
needs to move.
 
\item {\tt \_kernel\_image\_end}
 
This is a pointer to one past the last location in block RAM to place
things into. If this pointer is equal to {\tt \_kernel\_image\_start},
then no information is placed into block RAM.
 
\item {\tt \_sdram\_image\_start}
 
This should be equal to {\tt \_kernel\_image\_end}. It is a pointer,
within block RAM address space, of the first location to be moved
into SDRAM. By adding the difference between
{\tt \_sdram\_image\_start} and {\tt \_blkram} to the flash address
in {\tt \_kernel\_image\_start}, the actual source address within the
flash of the code/data that needs to be copied into SDRAM can be
determined.
 
\item {\tt \_sdram\_image\_end}
 
This is the ending address of any code/data to be copied into SDRAM.
The distance between this pointer and {\tt \_sdram} should be the
amount of data to be placed into SDRAM.
 
\item {\tt \_bss\_image\_end}
 
The BSS segment contains data the starts with an initial value of
zero. Such data are usually not placed in the executable file, nor
are they placed into any flash image. This address points to the
last location in SDRAM used by the BSS segment. The bootloader
is responsible then for clearing the SDRAM between
{\tt \_sdram\_image\_end} and {\tt \_bss\_image\_end}.
 
The bootloader must also be robust enough to handle the cases where
1) there is no SDRAM, 2) there is no block RAM, and 3) where there
is non requirement to move memory at all---such as when the program
is placed into memory and started from there.
\end{enumerate}
\subsection{Other required linker symbols}\label{sec:ld-other}
 
Two other symbols need to be defined in the linker script, which are used
by the startup code. These are:
\begin{enumerate}
\item {\tt \_top\_of\_stack}
 
This is the address that the startup code will set the stack pointer
to point to. It may be one past the last location of a RAM memory,
whether block RAM or SDRAM.
 
\item {\tt \_top\_of\_heap}
 
This is the first location past the end of the {\tt .bss} segment.
Equivalently, this is the address of the first unused piece of
memory, or the location from whence to start any dynamic memory
subsystem.
\end{enumerate}
 
\section{Loading ZipCPU Programs}
There are two basic ways to load a ZipCPU program, depending upon whether or
not the ZipCPU is active within the current configuration. If the ZipCPU
is not a part of the current FPGA configuration, one need only write the
flash and then switch configurations. It will be the CPU's responsibility
to place itself in RAM then.
 
The more practical alternative is a little more involved, and there are
several steps to it.
\begin{enumerate}
\item Halt the CPU by writing 0x0440 to the CPU control register. This
both halts and resets the CPU. It then prevents both bus contention,
while writing the new instructions to memory, as well as preventing the
CPU from running some instructions from one program and other
instructions from another.
\item Load the program into memory. For many programs this will involve
loading the program into flash, and necessitate having and using a
flash controller. The ZipCPU also supports being loaded straight into
RAM address as well, as though the bootloader had completed
it's task.
\item You may optionally, at this point, clear all of the CPUs registers,
to make certain the reboot is clean.
\item Set the sPC register to the starting address.
\item Clear the instruction cache in order to force the CPU to reload its
cache upon start.
\item Release the CPU by writing to the CPU debug control register a number
between 0 and 31. This number will correspond to the register number
of the register that can be ``peeked'' at while the CPU is running.
\end{enumerate}
 
%
\section{Starting a ZipCPU program}
\subsection{CRT0}
 
Most computers have a section of code, conventionally called {\tt crt0}, which
loads a program into memory. On the ZipCPU, this code starts at {\tt \_start}.
It is responsible for setting the stack pointer, calling the boot loader,
and then calling the main entry function, {\tt entry()}.
 
Because {\tt \_start} {\em must} be the first symbol in a program, and because
that first symbol is located at the boot address for the CPU, the {\tt \_start}
is placed into the {\tt .start} segment. It is the only routine placed there.
 
On those CPU's that don't have enough logic space for a debugger, it may be
useful to place a routine to dump any registers, stack values and/or kernel
traces to an output routine at this time. That way, on any kernel fault, the
kernel can be brought back up with a debug trace. This works because rebooting
the CPU doesn't reset any register values save the {\tt sCC} and {\tt sPC}.
 
\subsection{The Bootloader}
 
As discussed in Sec.~\ref{sec:ld-boot}, the bootloader must be placed into
flash if it is used. It can be a small C program (it need not be assembly,
like {\tt \_start}), and it only needs to copy memory. First, it copies any
memory from flash to block RAM. Second, it copies any necessary memory from
flash to SDRAM. Then, it zeros any memory necessary in SDRAM (or block RAM,
if there is no SDRAM).
 
These memory copies may be done with the DMA, or they may be done one--at--a
time for a performance penalty.
 
\subsection{Kernel Entry}
 
After calling the boot loader, execution returns to the {\tt \_start} routine
which then calls the main program entry function, {\tt entry()}. No
requirements are laid upon this entry function regarding where it must reside.
The simplest place to put it is in Block RAM--and just to put all code and
variables there. In reality, this entry function may easily be left in flash.
It often doesn't need to run particularly fast, since there may easily be
one--time setup functions that are independent of the programs main loop.
 
\subsection{Kernel Main}
 
If the kernel entry function, {\tt entry()}, is placed in flash, it should call
a separate function to run the main while loop once it has been set up. In
this fashion, the main while loop may be kept in the fastest memory necessary
(that it will fit within), to ensure good performance.
 
\chapter{Operation}\label{chap:ops}
 
This chapter will explore how to perform common tasks with the ZipCPU,
offering examples in both C and assembly for those tasks.
 
\section{CRT0}
 
Of course, the one task that every CPU must do is start the CPU for other
tasks. The ZipCPU is no different. This is the one ZipCPU task that must
take place in assembly, since no assumptions can be made about the state of
the ZipCPU upon entry. In particular, the stack pointer, SP, needs to be
loaded with a valid memory location before any higher level language can work.
Once that has taken place, it is then possible to call other higher level
routines.
 
Table.~\ref{tbl:op-init}
\begin{table}\begin{center}
\begin{tabbing}
{\em ; By starting our loader in the .start section, we guarantee through our}\\
{\em ; linker script that these are the very first instructions the CPU sees.}\\
\hbox to 0.25in{}\={\tt .section .start} \\
\> {\tt .global \_start} \\
{\em ; \_start is to be placed at our reboot/reset address, so it will be}\\
{\em ; called upon any reboot.}\\
{\tt \_start:} \\
\> {\em ; The most important step: creating a stack pointer. The value}\\
\> {\em ; {\tt \_top\_of\_stack} is created by the linker based upon the linker script.}\\
\> {\tt LDI \_top\_of\_stack,SP} \\
\> {\em ; We then call the bootloader to load our code into memory.}\\
\> {\tt MOV \_after\_bootloader(PC),R0} \\
\> {\tt BRA bootloader} \\
{\tt \_after\_bootloader:} \\
\> {\em ; Just in case the bootloader messed up the stack, we'll reset it here.}\\
\> {\tt LDI \_top\_of\_stack,SP} \\
\> {\em ; Finally, we call the entry function for the entire design.}\\
\> {\tt MOV \_kernel\_exit(PC),R0}\\
\> {\tt BRA entry}\\
{\em ; The {\tt \_kernel\_exit} routine that follows isn't strictly necessary,}\\
{\em ; since the CPU should never return from the {\tt entry()} function. However,}\\
{\em ; since returning from such a function is valid C code, and just in case}\\
{\em ; it does return, we provide this function as a fail safe to make sure}\\
{\em ; the kernel halts upon completion.}\\
{\tt \_kernel\_exit:}\\
\> {\tt HALT}\\
\> {\tt BRA \_kernel\_exit}
\end{tabbing}
\caption{Setting up a stack frame and starting the CPU}\label{tbl:op-init}
\end{center}\end{table}
presents an example of one such initialization routine
that first sets up the stack, then calls a bootloader routine. Upon completion,
the initialization routine then calls the main entry point for the CPU. Should
that main entry point ever return, a short routine following halts the CPU.
 
The example also highlights one optimization that didn't take place. Instead
of placing the {\tt \_after\_bootloader} address into {\tt R0}, this script
could have placed the {\tt entry()} address into {\tt R0}. Had it done so, the
CPU would not have suffered the pipeline stalls associated with two long jumps:
the first to {\tt R0}, and the second to {\tt entry}. Instead, it would have
suffered such stalls only once: when jumping to {\tt entry()}.
 
% \section{Example bootloader}
 
\section{System High}
The easiest and simplest way to run the Zip CPU is in the system high mode.
The easiest and simplest way to run the ZipCPU is in the system high mode.
In this mode, the CPU runs your program in supervisor mode from reboot to
power down, and is never interrupted. You will need to poll the interrupt
controller to determine when any external condition has become active. This
mode is useful, and can handle many microcontroller tasks.
mode is incredibly useful, and can handle many microcontroller--type tasks.
 
Even better, in system high mode, all of the user registers are available
to the system high program as variables. Accessing these registers can be
1851,8 → 2478,64
\caption{Executing an idle from supervisor mode}\label{tbl:shi-idle}
\end{center}\end{table}
 
There are some problems with this model, however. For example, even though
the user registers can be accessed in a single cycle, there is currently
no way to do so other than with assembly instructions.
 
An alternative to this approach is to use the {\tt zip\_wait()} built--in
function. This places the ZipCPU into an idle/sleep mode to wait for
interrupts. Because the supervisor puts the CPU to sleep, rather than the
user, no user context needs to be set up.
 
\section{A Programmable Delay}
 
One common task in microcontrollers, whether in a user task or supervisor
task, is to wait for a programmable amount of time. Using the ZipSystem,
there are several peripherals that can be used to create such a delay.
It can be done with one of the three timers, the jiffies, or even an off-chip
ZipCounter.
 
Here, in Tbl.~\ref{tbl:shi-timer},
\begin{table}\begin{center}
\begin{tabbing}
{\tt \#define EINT(A) (0x80000000|(A<<16))} \= {\em // Enable interrupt A}\\
{\tt \#define DINT(A) (A<<16)} \>{\em // Just disable the interrupts in A}\\
{\tt \#define DISABLEALL 0x7fff0000} \>{\em // Disable all interrupts}\\
{\tt \#define CLEARPIC 0x7fff7fff} \>{\em // Clears and disables all interrupts}\\
{\tt \#define SYSINT\_TMA 0x10} \>{\em // The Timer--A interrupt mask}\\
\\
{\tt void timer\_delay(int nclocks) \{} \\
\hbox to 0.25in{}\= {\em // Clear the PIC. We want to exit from here on timer counts alone}\\
\> {\tt zip->pic = DISABLEALL|SYSINT\_TMA;}\\
\> {\tt if (nclocks > 10) \{}\\
\> \hbox to 0.25in{}\= {\em // Set our timer to count down the given number of counts}\\
\> \> {\tt zip->tma = counts} \\
\> \> {\tt zip->pic = EINT(SYSINT\_TMA);} \\
\> \> {\tt zip\_wait();} \\
\> \> {\tt zip->pic = CLEARPIC;} \\
\> {\tt \} }{\em // else anything less has likely already passed}
{\tt \}}\\
\end{tabbing}
\caption{Waiting on a timer}\label{tbl:shi-timer}
\end{center}\end{table}
we present one means of waiting for a programmable amount of time using a
timer. If exact timing is important, you may wish to calibrate the method
by subtracting from the counts number the counts it takes to actually do the
routine. Otherwise, the timer is guaranteed to at least {\tt counts}
ticks.
 
Notice that the routine clears the PIC early on. While one might expect
that this could be done in the instruction immediately before {\tt zip\_rtu()},
this isn't the case. The reason is a race condition created by the fact that
the write to the PIC completes after the {\tt zip\_rtu()} instruction. As a
result, you might find yourself with a zero delay simply because the timer
had tripped some time earlier.
 
The routine is also careful not to clear any other interrupts beyond the timer
interrupt, lest some other condition trip that the user was also waiting on.
 
\section{Traditional Interrupt Handling}
Although the Zip CPU does not have a traditional interrupt architecture,
Although the ZipCPU does not have a traditional interrupt architecture,
it is possible to create the more traditional interrupt approach via software.
In this mode, the programmable interrupt controller is used together with the
supervisor state to create the illusion of more traditional interrupt handling.
1870,48 → 2553,40
\begin{table}\begin{center}
\begin{tabbing}
{\tt while(true) \{} \\
\hbox to 0.25in{}\= {\tt rtu();}\\
\> {\tt if (trap) \{} {\em // Here, we allow users to install ISRs, or} \\
\hbox to 0.25in{}\= {\tt zip\_rtu();}\\
\> {\tt if (zip\_ucc() \& CC\_TRAPBIT) \{} {\em // Here, we allow users to install ISRs, or} \\
\>\hbox to 0.25in{}\= {\em // whatever else they may wish to do in supervisor mode.} \\
\>\> {\tt \ldots} \\
\> {\tt \} else (zip\_ucc() \& (CC\_BUSERR|CC\_FPUERR|CC\_DIVERR)) \{}\\
\>\> {\em // Here we handle any faults that the CPU may have
encountered }\\
\>\> {\em // The easiest solution is often to print a trace and reboot}\\
\>\> {\em // the CPU.}\\
\>\> {\tt \_start();} \\
\> {\tt \} else \{} \\
\> \> {\tt volatile int *pic = PIC\_ADDRESS;} \\
\\
\> \> {\em // Save the user context before running any ISRs. This could easily be}\\
\> \> {\em // implemented as an inline assembly routine or macro}\\
\> \> {\tt SAVE\_PARTIAL\_CONTEXT; }\\
\> \> {\em // At this point, we know an interrupt has taken place: Ask the programmable}\\
\> \> {\em // interrupt controller (PIC) which interrupts are enabled and which are active.}\\
\> \> {\tt int picv = *pic;}\\
\> \> {\tt int picv = zip->pic;}\\
\> \> {\em // Turn off all active interrupts}\\
\> \> {\em // Globally disable interrupt generation in the process}\\
\> \> {\tt int active = (picv >> 16) \& picv \& 0x07fff;}\\
\> \> {\tt *pic = (active<<16);}\\
\> \> {\tt zip->pic = (active<<16);}\\
\> \> {\em // We build a mask of interrupts to re-enable in picv.}\\
\> \> {\tt picv = 0;}\\
\> \> {\tt for(int i=0,msk=1; i<15; i++, msk<<=1) \{}\\
\> \>\hbox to 0.25in{}\={\tt if ((active \& msk)\&\&(isr\_table[i])) \{}\\
\> \>\>\hbox to 0.25in{}\= {\tt mov(isr\_table[i],uPC); }\\
\> \>\>\> {\em // Acknowledge this particular interrupt. While we could acknowledge all}\\
\> \>\>\> {\em // interrupts at once, by acknowledging only those with ISR's we allow}\\
\> \>\>\> {\em // the user process to use peripherals manually, and to manually check}\\
\> \>\>\> {\em // whether or no those other interrupts had occurred.}\\
\> \>\>\> {\tt *pic = msk; }\\
\> \>\>\> {\tt rtu(); }\\
\> \>\>\> {\em // The ISR will only exit on a trap in the Zip archtecture. There is}\\
\> \>\>\> {\em // no {\tt RETI} instruction. Since the PIC holds all interrupts disabled,}\\
\> \>\>\> {\em // there is no need to check for further interrupts.}\\
\> \>\>\> {\em // }\\
\> \>\>\hbox to 0.25in{}\={\em // Here we call our interrupt service routine.}\\
\> \>\>\hbox to 0.25in{}\= {\tt tmp = (isr\_table[i])(); }\\
\> \>\>\> {\em // The tricky part is that, because of how the PIC is built, the ISR cannot}\\
\>\>\>\> {\em // re-enable its own interrupt without re-enabling all interrupts. Hence, we}\\
\>\>\>\> {\em // look at R0 upon ISR completion to know if an interrupt needs to be }\\
\>\>\>\> {\em // re-enable its own interrupts without re-enabling all interrupts. Hence, we}\\
\>\>\>\> {\em // look at the return value from the ISR to know if an interrupt needs to be }\\
\> \>\>\> {\em // re-enabled. }\\
\> \>\>\> {\tt mov(uR0,tmp); }\\
\> \>\>\> {\tt picv |= (tmp \& 0x7fff) << 16; }\\
\> \>\>\> {\tt if (tmp)} \\
\> \>\>\> \hbox to 0.25in{}\={\tt picv |= msk; }\\
\> \>\> {\tt \} }\\
\> \> {\tt \} }\\
\> \> {\tt RESTORE\_PARTIAL\_CONTEXT; }\\
\> \> {\em // Re-activate all (requested) interrupts }\\
\> \> {\tt *pic = picv | 0x80000000; }\\
\> \> {\em // Re-activate, but do not clear, all (requested) interrupts }\\
\> \> {\tt zip->pic = picv | 0x80000000; }\\
\>{\tt \} }\\
{\tt \}}\\
\end{tabbing}
1921,33 → 2596,13
We can work through the interrupt handling process by examining
Tbl.~\ref{tbl:traditional-isr}. First, remember, the CPU is always running
either the user or the supervisor context. Once the supervisor switches to
user mode, control does not return until either an interrupt or a trap
has taken place. (Okay, there's also the possibility of a bus error, or an
illegal instruction such as an unimplemented floating point instruction---but
for now we'll just focus on the trap instruction.) Therefore, if the trap bit
isn't set, then we know an interrupt has taken place.
user mode, control does not return until either an interrupt, a trap, or an
exception has taken place. Therefore, if neither the trap bit nor any of the
exception bits have been set, then we know an interrupt has taken place.
 
To process an interrupt, we steal the user's stack: the PC and CC registers
are saved on the stack, as outlined in Tbl.~\ref{tbl:save-partial}.
\begin{table}\begin{center}
\begin{tabbing}
SAVE\_PARTIAL\_CONTEXT: \\
\hbox to 0.25in{}\= {\em ; We save R0, CC, and PC only} \\
\> {\tt MOV -3(uSP),R3} \\
\> {\tt MOV uR0,R0} \\
\> {\tt MOV uCC,R1} \\
\> {\tt MOV uPC,R2} \\
\> {\tt STO R0,(R3)} {\em ; Exploit memory pipelining: }\\
\> {\tt STO R1,1(R3)} {\em ; All instructions write to stack }\\
\> {\tt STO R2,2(R3)} {\em ; All offsets increment by one }\\
\> {\tt MOV R3,uSP} {\em ; Return the updated stack pointer } \\
\end{tabbing}
\caption{Example Saving Minimal User Context}\label{tbl:save-partial}
\end{center}\end{table}
This is much cheaper than the full context swap of a preemptive multitasking
kernel, but it also depends upon the ISR saving any state it uses. Further,
if multiple ISR's get called at once, this looses its optimality property
very quickly.
It is also possible that an interrupt will occur coincident with a trap or
exception. If this is the case, the subsequent {\tt zip\_rtu()} instruction
will return immediately, since the interrupt has yet to be cleared.
 
As Sec.~\ref{sec:pic} discusses, the top of the PIC register stores which
interrupts are enabled, and the bottom stores which have tripped. (Interrupts
1961,76 → 2616,72
we keep track of which interrupts have tripped.
 
Using the bit mask of interrupts that have tripped, we walk through all fifteen
possible interrupts. If there is an ISR installed, we acknowledge and reset
the interrupt within the PIC, and then call the ISR. The ISR, however, cannot
re--enable its interrupt without re-enabling the master interrupt bit. Thus,
to keep things simple, when the ISR is finished it places its interrupt
mask back into R0, or clears R0. This tells the supervisor mode process which
interrupts to re--enable. Any other registers that the ISR uses must be
saved and restored. (This is only truly optimal if only a single ISR is
called.) As a final instruction, the ISR clears the GIE bit executing a user
trap. (Remember, the Zip CPU has no {\tt RETI} instruction to restore the
stack and return to userland. It needs to go through the supervisor mode to
get there.)
possible interrupts. If there is an ISR installed, we simply call it here. The
ISR, however, cannot re--enable its interrupt without re-enabling the master
interrupt bit. Thus, to keep things simple, when the ISR is finished it returns
a boolean into R0 to indicate whether or not the interrupt needs to be
re-enabled. Put together, this tells the kernel which interrupts to re--enable.
As a final instruction, interrupts are re--enabled before returning continuing
the while loop.
 
Then, once all interrupts are handled, the user context is restored in a
fashion similar to Tbl.~\ref{tbl:restore-partial}.
There you have it: the ZipCPU, with its non-traditional interrupt architecture,
can still process interrupts in a very traditional fashion.
 
\section{Idle Task}
One task every operating system needs is the idle task, the task that takes
place when nothing else can run. On the ZipCPU, this task is quite simple,
and it is shown in assembly in Tbl.~\ref{tbl:idle-asm},
\begin{table}\begin{center}
\begin{tabbing}
RESTORE\_PARTIAL\_CONTEXT: \\
\hbox to 0.25in{}\= {\em ; We retore R0, CC, and PC only} \\
\> {\tt MOV uSP,R3} {\em ; Return the updated stack pointer } \\
\> {\tt LOD R0,(R3),R0} {\em ; Exploit memory pipelining: }\\
\> {\tt LOD R1,1(R3),R1} {\em ; All instructions write to stack }\\
\> {\tt LOD R2,2(R3),R2} {\em ; All offsets increment by one }\\
\> {\tt MOV R0,uR0} \\
\> {\tt MOV R1,uCC} \\
\> {\tt MOV R2,uPC} \\
\> {\tt MOV 3(R3),uSP} \\
{\tt idle\_task:} \\
\hbox to 0.25in{}\= {\em ; Wait for the next interrupt, then switch to supervisor task} \\
\> {\tt WAIT} \\
\> {\em ; When we come back, it's because the supervisor wishes to} \\
\> {\em ; wait for an interrupt again, so go back to the top.} \\
\> {\tt BRA idle\_task} \\
\end{tabbing}
\caption{Example Restoring Minimal User Context}\label{tbl:restore-partial}
\caption{Example Idle Task in Assembly}\label{tbl:idle-asm}
\end{center}\end{table}
Again, this is short and sweet simply because any other registers that needed
saving were saved within the ISR.
or equivalently in C in Tbl.~\ref{tbl:idle-c}.
\begin{table}\begin{center}
\begin{tabbing}
{\tt void idle\_task(void) \{} \\
\hbox to 0.25in{}\={\tt while(true) \{} {\em // Never exit}\\
\> {\em // Wait for the next interrupt, then switch to supervisor task} \\
 
There you have it: the Zip CPU, with its non-traditional interrupt architecture,
can still process interrupts in a very traditional fashion.
\> {\tt zip\_wait();} \\
\> {\em // } \\
\> {\em // When we come back, it's because the supervisor wishes to} \\
\> {\em // wait for an interrupt again, so go back to the top.} \\
\> {\tt \}} \\
{\tt \}}
\end{tabbing}
\caption{Example Idle Task in C}\label{tbl:idle-c}
\end{center}\end{table}
 
\section{Example: Idle Task}
One task every operating system needs is the idle task, the task that takes
place when nothing else can run. On the Zip CPU, this task is quite simple,
and it is shown in assemble in Tbl.~\ref{tbl:idle-asm}.
\begin{table}\begin{center}
\begin{tabular}{ll}
{\tt idle\_task:} \\
& {\em ; Wait for the next interrupt, then switch to supervisor task} \\
& {\tt WAIT} \\
& {\em ; When we come back, it's because the supervisor wishes to} \\
& {\em ; wait for an interrupt again, so go back to the top.} \\
& {\tt BRA idle\_task} \\
\end{tabular}
\caption{Example Idle Loop}\label{tbl:idle-asm}
\end{center}\end{table}
When this task runs, the CPU will fill up all of the pipeline stages up the
ALU. The {\tt WAIT} instruction, upon leaving the ALU, places the CPU into
a sleep state where nothing more moves. Sure, there may be some more settling,
the pipe cache continue to read until full, other instructions may issue until
the pipeline fills, but then everything will stall. Then, once an interrupt
takes place, control passes to the supervisor task to handle the interrupt.
When control passes back to this task, it will be on the next instruction.
Since that next instruction sends us back to the top of the task, the idle
task thus does nothing but wait for an interrupt.
a sleep state where nothing more moves. Then, once an interrupt takes place,
control passes to the supervisor task to handle the interrupt. When control
passes back to this task, it will be on the next instruction. Since that next
instruction sends us back to the top of the task, the idle task thus does
nothing but wait for an interrupt.
 
This should be the lowest priority task, the task that runs when nothing else
can. It will help lower the FPGA power usage overall---at least its dynamic
power usage.
 
\section{Example: Memory Copy}
One common operation is that of a memory move or copy. Consider the C code
shown in Tbl.~\ref{tbl:memcp-c}.
For those highly interested in reducing power consumption, the clock could
even be disabled at this time--requiring only some small modifications to the
core.
 
\section{Memory Copy}
One common operation is that of a memory move or copy. This section will
present several methods available to the ZipCPU for performing a memory
copy, starting with the C code shown in Tbl.~\ref{tbl:memcp-c}.
\begin{table}\begin{center}
\parbox{4in}{\begin{tabbing}
{\tt void} \= {\tt memcp(void *dest, void *src, int len) \{} \\
{\tt void} \= {\tt memcpy(void *dest, void *src, int len) \{} \\
\> {\tt for(int i=0; i<len; i++)} \\
\> \hspace{0.2in} {\tt *dest++ = *src++;} \\
\}
2037,73 → 2688,454
\end{tabbing}}
\caption{Example Memory Copy code in C}\label{tbl:memcp-c}
\end{center}\end{table}
This same code can be translated in Zip Assembly as shown in
Each successive example will further speed up the memory copying process.
 
This memory copy code can be translated in Zip Assembly as shown in
Tbl.~\ref{tbl:memcp-asm}.
\begin{table}\begin{center}
\begin{tabular}{ll}
memcp: \\
& {\em ; R0 = *dest, R1 = *src, R2 = LEN, R3 = return addr} \\
& {\em ; The following will operate in $12N+19$ clocks.} \\
& {\tt CMP 0,R2} \\ % 8 clocks per setup
& {\tt MOV.Z R3,PC} {\em ; A conditional return }\\
& {\tt SUB 1,SP} {\em ; Create a stack frame}\\
& {\tt STO R4,(SP)} {\em ; and a local variable}\\
& {\em ; (4 stalls, cannot be further scheduled away)} \\
loop: \\ % 12 clocks per loop
& {\tt LOD (R1),R4} \\
& {\em ; (4 stalls, cannot be scheduled away)} \\
& {\tt STO R4,(R0)} {\em ; (4 schedulable stalls, has no impact now)} \\
& {\tt SUB 1,R2} \\
& {\tt BZ memcpend} \\
& {\tt ADD 1,R0} \\
& {\tt ADD 1,R1} \\
& {\tt BRA loop} \\
& {\em ; (1 stall on a BRA instruction)} \\
memcpend: % 11 clocks
& {\tt LOD (SP),R4} \\
& {\em ; (4 stalls, cannot be further scheduled away)} \\
& {\tt ADD 1,SP} \\
& {\tt JMP R3} \\
& {\em ; (4 stalls)} \\
\end{tabular}
\caption{Example Memory Copy code in Zip Assembly}\label{tbl:memcp-asm}
\begin{tabbing}
memcpy: \\
\hbox to 0.35in{}\={\em ; R0 = return address, R1 = *dest, R2 = *src, R3 = LEN} \\
\> {\em ; The following will operate in 6 ($N=0$), or $2+12N$ clocks ($N\neq 0$).} \\
\> {\tt CMP 0,R3} \\ % 8 clocks per setup
\> {\tt JMP.Z R0} \hbox to 0.3in{}\= {\em ; A conditional return }\\
\> {\em ; No stack frame needs to be set up to use {\tt R4}, since the compiler}\\
\> {\em ; assumes {\tt R1}-{\tt R4} may be used and changed by any subroutine} \\
memcpy\_loop: \\ % 12 clocks per loop
\> {\tt LOD (R2),R4} \\
\> {\em ; (4 stalls, cannot be scheduled away)} \\
\> {\tt STO R4,(R1)} \> {\em ; (4 schedulable stalls, has no impact now)} \\
\> {\em ; Update our count of the number of remaining values to copy}\\
\> {\tt SUB 1,R3} \> {\em ; This will be zero when we have copied our last}\\
\> {\tt JMP.Z R0} \> {\em ; + 4 stalls, if taken}\\
\> {\tt ADD 1,R1} \> {\em ; Implement the destination pointer }\\
\> {\tt ADD 1,R2} \> {\em ; Implement the source pointer }\\
\> {\tt BRA memcpy\_loop} \\
\> {\em ; (1 stall on a BRA instruction)} \\
\end{tabbing}
\caption{Example Memory Copy code in Zip Assembly, Unoptimized}\label{tbl:memcp-asm}
\end{center}\end{table}
This example points out several things associated with the Zip CPU. First,
This example points out several things associated with the ZipCPU. First,
a straightforward implementation of a for loop is not the fastest loop
structure. For this reason, we have placed the test to continue at the
end. Second, all pointers are {\tt void} pointers to arbitrary 32--bit
data types. The Zip CPU does not have explicit support for smaller or larger
data types, and so this memory copy cannot be applied at a byte level.
Third, we've optimized the conditional jump to a return instruction into a
conditional return instruction.
data types. The ZipCPU does not have explicit support for smaller or larger
data types, and so this memory copy cannot be applied at an 8--bit level.
Third, notice that we can use {\tt R4} without storing it, since the C~ABI
allows for subroutines to use {\tt R1}--{\tt R4} without saving them. This
means that we can return from this subroutine using conditional jumps to
{\tt R0}.
 
\section{Example: Context Switch}
Still, there's more that could be done. Suppose we wished to use the pipeline
bus capability? We might then write something closer to
Tbl.~\ref{tbl:memcp-opt}.
\begin{table}\begin{center}\scalebox{0.8}{\parbox{\textwidth}{%
\begin{tabbing}
% 27 cycles for 0
% 52 cycles for 3
{\em ; Upon entry, R0 = return address, R1 = *dest, R2 = *src, R3 = LEN} \\
{\em ; Achieves roughly $32+17\left\lfloor\frac{N}{4}\right\rfloor$ clocks,
after the initial pipeline delay}\\
memcpy\_opt: \\
\hbox to 0.35in{}\=\hbox to 1.4in{\tt CMP 4,R3}\= {\em ; Check for small short lengths, len $<$ 4}\\
\> {\tt BC memcpy\_finish} \> {\em ; Jump to the end if so}\\
\hbox to 0.35in{}\=\hbox to 1.4in{\tt SUB 3,SP}\= {\em ; Otherwise, create a stack frame, storing the registers}\\
\> {\tt STO R5,(SP)} \> {\em ; we will be using. Note that this is a pipelined store, so}\\
\> {\tt STO R6,1(SP)} \> {\em ; subsequent stores only cost 1 clock.}\\
\> {\tt STO R7,2(SP)}\\
\> {\tt ADD 4,R2} \> {\em ; Pre-Increment our pointers, for a 4-stage pipeline. This}\\
\> {\tt ADD 4,R1} \> {\em ; also fills up the 3 of the 4 stall states following the}\\
\> {\tt SUB 5,R3} \> {\em ; stores. Also, leave {\tt R3} as the number left minus one.}\\
\> {\tt LOD -4(R2),R4} \> {\em ; Load the first four values into }\\
\> {\tt LOD -3(R2),R5} \> {\em ; registers, using a pipelined load.}\\
\> {\tt LOD -2(R2),R6}\\
\> {\tt LOD -1(R2),R7}\\
{\tt mcopy\_next\_four\_chars:} \>\> {\em ; Here's the top of our copy loop}\\
\> {\tt STO R4,-4(R1)} \> {\em ; Store four values, using a burst memory operation.}\\
\> {\tt STO R5,-3(R1)} \> {\em ; One clock for subsequent stores.}\\
\> {\tt STO R6,-2(R1)} \> {\em ; None of these effect the flags, that were set when}\\
\> {\tt STO R7,-1(R1)} \> {\em ; we last adjusted {\tt R3}}\\
\> {\tt BC preend\_memcpy} \> {\em ; +4 stall cycles, but only when taken}\\
\> {\tt ADD 4,R1} \> {\em ; ALU ops don't stall during stores, so}\\
\> {\tt ADD 4,R2} \> {\em ; increment our pointers here.} \\
\> {\tt SUB 4,R3} \> {\em ; Calculate whether or not we have a next round}\\
\> {\tt LOD -4(R2),R4} \> {\em ; Preload the values for the next round}\\
\> {\tt LOD -3(R2),R5}\> {\em ; Notice that these are also pipelined}\\
\> {\tt LOD -2(R2),R6}\> {\em ; loads, as before.}\\
\> {\tt LOD -1(R2),R7}\> {\em ; The four stall cycles, though, are concurrent w/ the branch.}\\
\> {\tt BRA mcopy\_next\_char} \> {\em ; Early branching avoids the full memory pipeline stall} \\
{\tt preend\_memcpy:}\\
\> {\tt ADD 1,R3} \>{\em ; R3 is now the remaining length, rather than one less than it}\\
\> {\tt LOD (SP),R5} \> {\em ; Restore our saved registers, since the remainder of the routine}\\
\> {\tt LOD 1(SP),R6} \> {\em ; doesn't use these registers}\\
\> {\tt LOD 2(SP),R7} \> {\em ;}\\
\> {\tt ADD 3,SP} \>{\em ; Adjust the stack pointer back to what it was}\\
{\tt memcpy\_finish:}\>\>{\em ; At this point, there are $0\leq$ {\tt R3}$<4$ words left}\\
\> {\tt CMP 1,R3} \> {\em ; Check if any ops are remaining }\\
\> {\tt JMP.LT R0} \> {\em ; Return now if nothing is left}\\
\> {\tt LOD (R1),R4} \> {\em ; Load and store the first item}\\
\> {\tt STO R4,(R1)} \> {\em ;}\\
\> {\tt JMP.Z R0} \> {\em ; Return if that was our only value}\\
\> {\tt LOD 1(R1),R4}\>{\em; Load and store the second item (if necessary)} \\
\> {\tt STO R4,1(R1)}\\
\> {\tt CMP 2, R3}\\
\> {\tt JMP.LT R0}\\
\> {\tt LOD 2(R1),R4}\>{\em; Load and store the second item (if necessary)} \\
\> {\tt STO R4,2(R1)}\>{\em; {\tt LOD}, {\tt STO}, {\tt JMP R0} will cost 10 cycles}\\
\> {\tt JMP R0} \> {\em ; Finally, we return}\\
\end{tabbing}}}
\caption{Example Memory Copy code in Zip Assembly, Hand Optimized}\label{tbl:memcp-opt}
\end{center}\end{table}
This pipeline memory example, though, provides some neat things to discuss
about optimizing code using the ZipCPU.
 
First, note that all of the loads and stores, except the three following
{\tt memcpy\_finish}, are pipelined. To do this, we needed to unroll the
copy loop by a factor of four. This means that each time through the loop,
we can read and store four values. At 17~clocks to copy four values, that's
roughly three times faster than our previous example. The down side, though,
is that the loop now needs a final cleanup section where the last 0--3 values
will be copied.
 
Second, note that we used our remaining length minus one as our loop variable.
This was done so that the conditions set by subtracting four from our loop
variable could be used without a separate compare. Speaking of the compare,
note that we have chosen to use a branch if carry ({\tt BC}) comparison, which
is equivalent to a less--than unsigned comparison.
 
Third, notice how we packed four ALU instructions, two adds, a subtract, and a
conditional branch, after the four store instructions. These instructions can
complete while the memory unit is busy, preparing us to start the subsequent
load without any further stalls (unless the memory is particularly slow.)
 
Next, you may wish to notice that the four memory loads within the loop are
followed by the early branching instruction. As a result, the branch costs
no extra clocks, and the time between the loads at the bottom of the loop
is dominated by the load to store time frame.
 
Finally, notice how the comparison at the end has been stacked. By comparing
against one, we can return when there are zero items left, or one item left,
without needing a new comparison. Hence, zero to three separate values can be
copied using only two compares.
 
However, this discussion wouldn't be complete without an example of how
this memory operation would be made even simpler using the direct memory
access controller. In that case, we can return to C with the code in
Tbl.~\ref{tbl:memcp-dmac}.
\begin{table}\begin{center}
\begin{tabbing}
{\tt \#define DMACOPY 0x0fed0000} {\em // Copy memory, largest chunk at a time possible} \\
\\
{\tt void} \= {\tt memcpy\_dma(void *dest, void *src, int len) \{} \\
\> {\em // This assumes we have access to the DMA, that the DMA is not}\\
\> {\em // busy, and that we are running in system high mode ...}\\
\> {\tt zip->dma.len = len;} \= {\em // Set up the DMA }\\
\> {\tt zip->dma.rd = src;}\\
\> {\tt zip->dma.wr = dst;}\\
\> {\em // Command the DMA to start copying} \\
\> {\tt zip->dma.ctrl= DMACOPY;} \\
\> {\em // Note that we take two clocks to set up our PIC. This is }\\
\> {\em // required because the PIC takes at least a clock cycle to clear.} \\
\> {\tt zip->pic = DISABLEALL|SYSINT\_DMA;} \\
\> {\em // Now that our PIC is actually clear, with no more DMA }\\
\> {\em // interrupt within it, now we enable the DMA interrupt, and}\\
\> {\em // only the DMA interrupt.}\\
\> {\tt zip->pic = EINT(SYSINT\_DMA);}\\
\> {\em // And wait for the DMA to complete.} \\
\> {\tt zip\_wait();}\\
{\tt \}}
\end{tabbing}
\caption{Example Memory Copy code using the DMA}\label{tbl:memcp-dmac}
\end{center}\end{table}
For large memory amounts, the cost of this approach will scale at roughly
2~clocks per word transferred.
 
Notice how much simpler this memory copy has become to write by using the DMA.
But also consider, the system has only one direct memory access controller.
What happens if one task tries to use the controller when it is already in use
by another task? The result is that the direct memory access controller may
need some special protections to make certain that only one task uses it at a
time---much like any other hardware peripheral.
 
\section{Memset}
Another example worth discussing is the {\tt memset()} library function.
A straightforward implementation of this function in C might look like
Tbl.~\ref{tbl:memset-c}.
\begin{table}\begin{center}
\begin{tabbing}
\hbox to 0.4in{\tt void} \= {\tt *memset(void *s, int c, size\_t n) \{} \\
\> {\tt for(size\_t i=0; i<n; i++)} \\
\> \hspace{0.4in} {\tt *s++ = c;} \\
\> {\tt return s;}\\
{\tt \}}
\end{tabbing}
\caption{Example Memset code}\label{tbl:memset-c}
\end{center}\end{table}
The function is simple enough to handle compile into the assembling listing in
Tbl.~\ref{tbl:memset-unop}.
\begin{table}\begin{center}
\begin{tabbing}
{\em ; Upon entry, R0 = return address, R1 = s, R2 = c, R3 = len}\\
{\em ; Cost: Roughly $4+6N$ clocks}\\
{\tt memset:}\\
\hbox to 0.25in{}\=\hbox to 1in{\tt TST R3}\={\em ; Return immediately if len (R3) is zero}\\
\> {\tt JMP.Z R0}\\
\> {\tt MOV R1,R4} \> {\em ; Keep our return value in R1, use R4 as a local}\\
{\tt memset\_loop:}\>\> {\em ; Here, we know we have at least one more to go}\\
\> {\tt STO R2,(R4)} \> {\em ; Store one value (no pipelining)} \\
\> {\tt SUB 1,R3} \> {\em; Subtract during the store}\\
\> {\tt JMP.Z R0} \> {\em; Return (during store) if all done}\\
\> {\tt ADD 1,R4} \> {\em; Otherwise increment our pointer}\\
\> {\tt BRA memset\_loop} {\em ; and repeat}\\
\end{tabbing}
\caption{Example Memset code, minimally optimized}\label{tbl:memset-unop}
\end{center}\end{table}
Note that we grab {\tt R4} as a local variable, so that we can maintain the
source pointer in {\tt R1} as our result upon return. This is valid, since the
compiler assumes that {\tt R1}--{\tt R4} will be clobbered upon any function
call and so they are not saved.
 
You can also see that this straight forward implementation costs about
six clocks per value to be set.
 
Were we to pipeline the memory accesses, we might choose to unroll the loop
and do something more like Tbl.~\ref{tbl:memset-pipe}.
\begin{table}\begin{center}
\begin{tabbing}
{\em ; Upon entry, R0 = return address, R1 = s, R2 = c, R3 = len}\\
{\em ; Cost: roughly $20+9\left\lfloor\frac{N}{4}\right\rfloor$}\\
{\tt memset\_pipe:}\\
\hbox to 0.25in{}\=\hbox to 0.6in{\tt MOV}\=\hbox to 1.0in{\tt R1,R4}\={\em ; Make a local copy of *s, so we can return R1}\\
\> {\tt CMP}\>{\tt 4,R3}\>{\em ; Jump to non--unrolled section}\\
\> {\tt JMP.C}\>{\tt memset\_pipe\_tail}\\
\> {\tt SUB}\>{\tt 1,R3}\> {\em ; R3 is now one less than the number to finish}\\
{\tt memset\_pipe\_unrolled:}\>\>\> {\em ; Here, we know we have at least four more to go}\\
\> {\tt STO}\>{\tt R2,(R4)} \> {\em ; Store our four values, pipelining our}\\
\> {\tt STO}\>{\tt R2,1(R4)} \> {\em ; access across the bus }\\
\> {\tt STO}\>{\tt R2,2(R4)} \\
\> {\tt STO}\>{\tt R2,3(R4)} \\
\> {\tt SUB}\>{\tt 4,R3} \> {\em; If there are zero left, this will be a -1 result}\\
\> {\tt JMP.C}\>{\tt prememset\_pipe\_tail}\> \hbox to 0.5in{}\= {\em; So we can use our LT condition}\\
\> {\tt ADD}\>{\tt 4,R4} \> {\em ; Otherwise increment our pointer}\\
\> {\tt BRA}\>{\tt memset\_pipe\_loop} {\em ; and repeat using an early branchable instruction}\\
{\tt prememset\_pipe\_tail:} \\
\> {\tt ADD}\>{\tt 1,R3}\>{\em ; Return our counts left to the run number}\\
{\tt memset\_pipe\_tail:}\>\>\>{\em ; At this point, we have R3=0-3 remaining}\\
\> {\tt CMP}\>{\tt 1,R3} \> {\em ; If there's less than one left}\\
\> {\tt JMP.C}\>{\tt R0} \> {\em ; then return early.}\\
\> {\tt STO}\>{\tt R2,(R4)} \> {\em ; If we've got one left, store it}\\
\> {\tt STO.GT}\>{\tt R2,1(R4)} \> {\em ; if two, do a burst store}\\
\> {\tt CMP}\>{\tt 3,R3} \> {\em ; Check if we have another left}\\
\> {\tt STO.Z}\>{\tt R2,2(R4)} \> {\em ; and store it if so.}\\
\> {\tt JMP}\>{\tt R0} \> {\em ; Return now that we are complete.}
\end{tabbing}
\caption{Example Memset after loop unrolling, using pipelined memory ops}\label{tbl:memset-pipe}
\end{center}\end{table}
Note that, in this example as with the {\tt memcpy} example, our loop variable
is one less than the number of operations remaining. This is because the ZipCPU
has no less than or equal comparison, but only a less than comparison. Further,
because the length is given as an unsigned quantity, we {\em only} have a
less than comparison. By subtracting one from the loop variable, that's
all our comparison needs to be--at least, until the end of the loop. For
that, we jump to a section one instruction earlier and return our counts
value to the true remaining length.
 
You may also notice that, despite the four possibilities in the end game, we
can carefully rearrange the logic to only use two compares. The first compare
tests against less than one and returns if there are no more sets left. Using
the same compare, though, we can also know if we have one or more stores left.
Hence, we can create a burst memory operation with one or two stores.
 
As one final example, we might also use the DMA for this operation, as with
Tbl.~\ref{tbl:memset-dma}.
\begin{table}\begin{center}
\begin{tabbing}
{\tt \#define DMA\_CONSTSRC 0x20000000} {\em // Don't increment the source address}
\\
{\tt void *} \= {\tt memset\_dma(void *s, int c, size\_t len) \{} \\
\> {\em // As before, this assumes we have access to the DMA, and that}\\
\> {\em // we are running in system high mode ...}\\
\> {\tt zip->dma.len = len;} \= {\em // Set up the DMA }\\
\> {\tt zip->dma.rd = \&c;}\\
\> {\tt zip->dma.wr = s;}\\
\> {\em // Command the DMA to start copying, but not to increment the} \\
\> {\em // source address during the copy.} \\
\> {\tt zip->dma.ctrl= DMACOPY|DMA\_CONSTSRC;} \\
\> {\em // Note that we take two clocks to set up our PIC. This is }\\
\> {\em // required because the PIC takes at least a clock cycle to clear.} \\
\> {\tt zip->pic = DISABLEALL|SYSINT\_DMA;} \\
\> {\em // Now that our PIC is actually clear, with no more DMA }\\
\> {\em // interrupt within it, now we enable the DMA interrupt, and}\\
\> {\em // only the DMA interrupt.}\\
\> {\tt zip->pic = EINT(SYSINT\_DMA);}\\
\> {\em // And wait for the DMA to complete.} \\
\> {\tt zip\_wait();}\\
{\tt \}}
\end{tabbing}
\caption{Example Memset code, only this time with the DMA}\label{tbl:memset-dma}
\end{center}\end{table}
This is almost identical to the {\tt memcpy} function above that used the
DMA, save that the pointer for the value read is given to be the address
of c, and that the DMA is instructed not to increment its source pointer.
The DMA will still do {\tt len} reads, so the asymptotic performance will never
be less than $2N$ clocks per transfer.
 
\section{String Operations}
Perhaps one of the immediate questions most folks will have is, how does one
handle string operations on a CPU that only handles 32--bit numbers? Here we
offer a couple of possibilities.
 
The first possibility is the easy and natural choice: just define characters
to be 32--bit numbers and ignore the upper 24 bits. This is the choice made
by the compiler. Hence, if you compile a simple string compare function,
such as Tbl.~\ref{tbl:str-cmp},
\begin{table}\begin{center}
\begin{tabbing}
\hbox to 0.25in{\tt int} \= {\tt strcmp(const char *s1, const char *s2) \{} \\
\> {\tt while(*s1 == *s2)} \\
\> \hbox to 0.25in{} {\tt s1++, s2++;} \\
\> {\tt return *s2 - *s1;} \\
{\tt \}}
\end{tabbing}
\caption{Example string compare function}\label{tbl:str-cmp}
\end{center}\end{table}
string length function, such as Tbl.~\ref{tbl:str-len},
\begin{table}\begin{center}
\begin{tabbing}
{\tt unsigned} \= {\tt strlen(const char *s) \{} \\
\> {\tt int ln = 0;} \\
\> {\tt while(*s++ != 0)} \\
\> \hbox to 0.25in{} {\tt ln++;} \\
\> {\tt return ln;} \\
{\tt \}}
\end{tabbing}
\caption{Example string compare function}\label{tbl:str-len}
\end{center}\end{table}
or string copy function, such as Tbl.~\ref{tbl:str-cpy},
\begin{table}\begin{center}
\begin{tabbing}
{\tt char *} \= {\tt strcpy(char *dest, const char *src) \{} \\
\> {\tt char *d = dest;} {\em // Make a working copy of the dest ptr}\\
\> {\tt do \{} \\
\> \hbox to 0.25in{} {\tt *d++ = *src;} \\
\> {\tt \} while(*src++);} \\
\> {\tt return dest;} \\
{\tt \}}
\end{tabbing}
\caption{Example string copy function}\label{tbl:str-cpy}
\end{center}\end{table}
this is what you will get.
 
A little work with these functions, and you should be able to optimize them
in a fashion similar to that with memcpy. This doesn't solve the fundamental
problem, though, of why am I wasting 32--bits for 8--bit quantities?
 
An alternative would be to use a packed string structure. To pack a string,
one might do something like Tbl.~\ref{tbl:pstr}.
\begin{table}\begin{center}
\begin{tabbing}
{\tt void} \= {\tt packstr(char *s) \{} \\
\> {\tt char *d = s;} \= {\em // Pack our string in place} \\
\> {\tt int w;}\>{\em // A holding word to pack things into} \\
\> {\tt int k=0;}\>{\em // A count to know when to move to the next word} \\
\> {\tt while(*s) \{} \\
\> \hbox to 0.25in{}\={\tt w = (w<<8)|(*s \& 0x0ff);} \\
\>\> {\em // After four of these octets, write the result out} \\
\> \> {\tt if (((++k)\&3)==0) *d++ = w;} \\
\> {\tt \}} \\
\> {\em // But what happens if we never got to the fourth octet}\\
\> {\em // in our last word? We need to clean that up here.}\\
\\
\> {\em // First, shift the partial value all the way up}\\
\> {\tt w = (w<<(32-((k\&3)<<3));} {\em // Shift up the last word}\\
\> {\tt *d++ = w;} {\em // Store any remaining partial value }\\
\> {\em // If we want to make sure our strings end in zero, we need}\\
\> {\em // one more step:}\\
\> {\tt *d = 0;} {\em // Make sure string ends in a zero.}\\
{\tt \}}
\end{tabbing}
\caption{String packing function}\label{tbl:pstr}
\end{center}\end{table}
Notice that our packed string places its first byte in the high order octet
of our first word, that any excess octets in the last word are zeros,
and that there remains a zero word following our string. With this packed
string approach, compares and copies can proceed four times faster. As an
example, Tbl.~\ref{tbl:pstr-cmp}
\begin{table}\begin{center}
\begin{tabbing}
\hbox to 0.25in{\tt int} \= {\tt pstrcmp(const char *s1, const char *s2) \{} \\
\> {\tt while(*s1 == *s2)} \\
\> \hbox to 0.25in{} {\tt s1++, s2++;} \\
\> {\tt return *s2 - *s1;} \\
{\tt \}}
\end{tabbing}
\caption{Packed string compare function}\label{tbl:pstr-cmp}
\end{center}\end{table}
presents a string compare function for a packed string. You'll notice that
it doesn't look all that different from a string compare for a non-packed
string. This is on purpose. Another example might be a string copy, which
again, wouldn't look all that different. Getting the number of used 8--bit
octets within a string is a touch more difficult. In that case, one might
try something like Tbl.~\ref{tbl:pstr-len}.
\begin{table}\begin{center}
\begin{tabbing}
{\tt unsigned} \= {\tt pstrlen(const char *s) \{} \\
\> {\tt int ln = 0;} \\
\> {\tt while(*s++ != 0)} \\
\> \hbox to 0.25in{}\={\tt ln+=4;} \\
\> {\tt if (ln) \{}\\
\>\> {\em // Touch up the length in case of an incomplete last word} \\
\>\> {\tt int lastval = s[-1];}\\
\\
\>\> {\tt if ((lastval \& 0x0ff)==0) ln--;}\\
\>\> {\tt if ((lastval \& 0x0ffff)==0) ln--;}\\
\>\> {\tt if ((lastval \& 0x0ffffff)==0) ln--;}\\
\> {\tt \}} \\
\> {\tt return ln;} \\
{\tt \}}
\end{tabbing}
\caption{Packed string subcharacter length function}\label{tbl:pstr-len}
\end{center}\end{table}
 
\section{Context Switch}
 
Fundamental to any multiprocessing system is the ability to switch from one
task to the next. In the ZipSystem, this is accomplished in one of a couple
ways. The first step is that an interrupt happens. Anytime an interrupt
happens, the CPU needs to execute the following tasks in supervisor mode:
task to the next. In the ZipSystem, this is accomplished in one of a couple of
ways. The first step is that an interrupt, trap, or exception takes place.
This will pull the CPU out of user mode and into supervisor mode. At this
point, the CPU needs to execute the following tasks:
\begin{enumerate}
\item Check for a trap instruction, or other user exception such as a break,
bus error, division by zero error, or floating point exception. That
is, if the user process needs attending then we may not wish to adjust
the context, check interrupts, or call the scheduler.
\item Check for the reason, why did we return from user mode? Did the user
execute a trap instruction, or did some other user exception such as a
break, bus error, division by zero error, or floating point exception
occur. That is, if the user process needs attending then we may not
wish to adjust the context, check interrupts, or call the scheduler.
Tbl.~\ref{tbl:trap-check}
\begin{table}\begin{center}
\begin{tabular}{ll}
{\tt return\_to\_user:} \\
& {\em; The instruction before the context switch processing must} \\
& {\em; be the RTU instruction that enacted user mode in the first} \\
& {\em; place. We show it here just for reference.} \\
& {\tt RTU} \\
{\tt trap\_check:} \\
& {\tt MOV uCC,R0} \\
& {\tt TST \$TRAP \textbar \$BUSERR \textbar \$DIVE \textbar \$FPE,R0} \\
& {\tt BNZ swap\_out} \\
& {; \em Do something here to execute the trap} \\
& {; \em Don't need to call the scheduler, so we can just return} \\
& {\tt BRA return\_to\_user} \\
\end{tabular}
\begin{tabbing}
{\tt while(true) \{} \\
\hbox to 0.25in{}\={\em // The instruction before the context switch processing must} \\
\> {\em // be the RTU instruction that enacted user mode in the first} \\
\> {\em // place. We show it here just for reference.} \\
\> {\tt zip\_rtu();} \\
\\
\> {\tt if (zip\_ucc() \& (CC\_FAULT)) \{} \\
\> \hbox to 0.25in{}\={\em // The user program has experienced an unrecoverable fault and must die.}\\
\>\> {\em // Do something here to kill the task, recover any resources} \\
\>\> {\em // it was using, and report/record the problem.}\\
\>\> \ldots \\
\> {\tt \} else if (zip\_ucc() \& (CC\_TRAPBIT)) \{} \\
\>\> {\em // Handle any user request} \\
\>\> {\tt zip\_restore\_context(userregs);} \\
\>\> {\em // If the request ID is in uR1, that is now userregs[1]}\\
\>\> {\tt switch(userregs[1]) \{} \\
\>\> {\tt case $x$:} {\em // Perform some user requested function} \\
\>\> \hbox to 0.25in{}\= {\tt break;}\\
\>\> {\tt \}} \\
\> {\tt \}}\\
\\
{\tt \}}
\end{tabbing}
\caption{Checking for whether the user task needs our attention}\label{tbl:trap-check}
\end{center}\end{table}
shows the rudiments of this code, while showing nothing of how the
2114,32 → 3146,29
Remember, the supervisor process is re--entered where it left off. This is
different from many other processors that enter interrupt mode at some vector
or other. In this case, we always enter supervisor mode right where we last
left.\footnote{The one exception to this rule is upon reset where supervisor
mode is entered at a pre--programmed wishbone memory address.}
left.
 
\item Capture user counters. If the operating system is keeping track of
system usage via the accounting counters, those counters need to be
copied and accumulated into some master counter at this point.
\item Capture user accounting counters. If the operating system is keeping
track of system usage via the accounting counters, those counters need
to be copied and accumulated into some master counter at this point.
 
\item Preserve the old context. This involves pushing all the user registers
onto the user stack and then copying the resulting stack address
into the tasks task structure, as shown in Tbl.~\ref{tbl:context-out}.
\item Preserve the old context. This involves recording all of the user
registers to some supervisor memory structure, such as is shown in
Tbl.~\ref{tbl:context-out}.
\begin{table}\begin{center}
\begin{tabular}{ll}
{\tt swap\_out:} \\
& {\tt MOV -15(uSP),R5} \\
& {\tt STO R5,stack(R12)} \\
& {\tt MOV uR0,R0} \\
& {\tt MOV uR1,R1} \\
& {\tt MOV uR2,R2} \\
& {\tt MOV uR3,R3} \\
& {\tt MOV uR4,R4} \\
& {\tt STO R0,(R5)} {\em ; Exploit memory pipelining: }\\
& {\tt STO R1,1(R5)} {\em ; All instructions write to stack }\\
& {\tt STO R2,2(R5)} {\em ; All offsets increment by one }\\
& {\tt STO R3,3(R5)} {\em ; Longest pipeline is 5 cycles.}\\
& {\tt STO R4,4(R5)} \\
& \ldots {\em ; Need to repeat for all user registers} \\
\begin{tabbing}
{\tt save\_context:} \\
\hbox to 0.25in{}\={\tt SUB 1,SP}\hbox to 0.5in{}\= {\em ; Function prologue: create a stack}\\
\> {\tt STO R5,(SP)} \> {\em ; frame and save R5. (R1-R4 are assumed}\\
\> {\tt MOV uR0,R2} \> {\em ; to be used and in need of saving. Then}\\
\> {\tt MOV uR1,R3} \> {\em ; copy the user registers, four at a time to }\\
\> {\tt MOV uR2,R4} \> {\em ; supervisor registers, where they can be}\\
\> {\tt MOV uR3,R5} \> {\em ; stored, while exploiting memory pipelining}\\
\> {\tt STO R2,(R1)} \>{\em ; Exploit memory pipelining: }\\
\> {\tt STO R3,1(R1)} \>{\em ; All instructions write to same base memory}\\
\> {\tt STO R4,2(R1)} \>{\em ; All offsets increment by one }\\
\> {\tt STO R5,3(R1)} \\
\> \ldots {\em ; Need to repeat for all user registers} \\
\iffalse
& {\tt MOV uR5,R0} \\
& {\tt MOV uR6,R1} \\
2152,82 → 3181,34
& {\tt STO R3,8(R5) }\\
& {\tt STO R4,9(R5)} \\
\fi
& {\tt MOV uR10,R0} \\
& {\tt MOV uR11,R1} \\
& {\tt MOV uR12,R2} \\
& {\tt MOV uCC,R3} \\
& {\tt MOV uPC,R4} \\
& {\tt STO R0,10(R5)}\\
& {\tt STO R1,11(R5)}\\
& {\tt STO R2,12(R5)}\\
& {\tt STO R3,13(R5)}\\
& {\tt STO R4,14(R5)} \\
& {\em ; We can skip storing the stack, uSP, since it'll be stored}\\
& {\em ; elsewhere (in the task structure) }\\
\end{tabular}
\> {\tt MOV uR12,R2} \> {\em ; Finish copying ... } \\
\> {\tt MOV uSP,R3} \\
\> {\tt MOV uCC,R4} \\
\> {\tt MOV uPC,R5} \\
\> {\tt STO R2,12(R1)} \> {\em ; and saving the last registers.}\\
\> {\tt STO R3,13(R1)} \> {\em ; Note that even the special user registers }\\
\> {\tt STO R4,14(R1)} \> {\em ; are saved just like any others. }\\
\> {\tt STO R5,15(R1)} \\
\> {\tt LOD (SP),R5} \> {\em ; Restore our one saved register}\\
\> {\tt ADD 1,SP} \> {\em ; our stack frame,} \\
\> {\tt JMP R0} \> {\em ; and return }\\
\end{tabbing}
\caption{Example Storing User Task Context}\label{tbl:context-out}
\end{center}\end{table}
For the sake of discussion, we assume the supervisor maintains a
pointer to the current task's structure in supervisor register
{\tt R12}, and that {\tt stack} is an offset to the beginning of this
structure indicating where the stack pointer is to be kept within it.
Since this task is so fundamental, the ZipCPU compiler back end provides
the {\tt zip\_save\_context(int *)} function.
 
For those who are still interested, the full code for this context
save can be found as an assembler macro within the assembler
include file, {\tt sys.i}.
 
\item Reset the watchdog timer. If you are using the watchdog timer, it should
be reset on a context swap, to know that things are still working.
Example code for this is shown in Tbl.~\ref{tbl:reset-watchdog}.
\begin{table}\begin{center}
\begin{tabular}{ll}
\multicolumn{2}{l}{{\tt `define WATCHDOG\_ADDRESS 32'hc000\_0002}}\\
\multicolumn{2}{l}{{\tt `define WATCHDOG\_TICKS 32'd1\_000\_000} {; \em = 10 ms}}\\
& {\tt LDI WATCHDOG\_ADDRESS,R0} \\
& {\tt LDI WATCHDOG\_TICKS,R1} \\
& {\tt STO R1,(R0)}
\end{tabular}
\caption{Example Watchdog Reset}\label{tbl:reset-watchdog}
\end{center}\end{table}
 
\item Interrupt handling. An interrupt handler within the Zip System is nothing
more than a task. At context swap time, the supervisor needs to
disable all of the interrupts that have tripped, and then enable
all of the tasks that would deal with each of these interrupts.
These can be user tasks, run at higher priority than any other user
tasks. Either way, they will need to re--enable their own interrupt
themselves, if the interrupt is still relevant.
\item Interrupt handling. How you handle interrupts on the ZipCPU are up to
you. You can activate a sleeping task if you like, or for smaller
faster interrupt routines, such as copying a character to or from a
serial port or providing a sample to an audio port, you might choose
to do the task within the kernel main loop. The difference may
depend upon how you have your hardware set up, and how fast the
kernel main loop is.
 
An example of this master interrut handling is shown in
Tbl.~\ref{tbl:pre-handler}.
\begin{table}\begin{center}
\begin{tabular}{ll}
{\tt pre\_handler:} \\
& {\tt LDI PIC\_ADDRESS,R0 } \\
& {\em ; Start by grabbing the interrupt state from the interrupt}\\
& {\em ; controller. We'll store this into the register R7 so that }\\
& {\em ; we can keep and preserve this information for the scheduler}\\
& {\em ; to use later. }\\
& {\tt LOD (R0),R1} \\
& {\tt MOV R1,R7 } \\
& {\em ; As a next step, we need to acknowledge and disable all active}\\
& {\em ; interrupts. We'll start by calculating all of our active}\\
& {\em ; interrupts.}\\
& {\tt AND 0x07fff,R1 } \\
& {\em ; Put the active interrupts into the upper half of R1} \\
& {\tt ROL 16,R1 } \\
& {\tt LDILO 0x0ffff,R1 } \\
& {\tt AND R7,R1}\\
& {\em ; Acknowledge and disable active interrupts}\\
& {\em ; This also disables all interrupts from the controller, so}\\
& {\em ; we'll need to re-enable interrupts in general shortly } \\
& {\tt STO R1,(R0) } \\
& {\em ; We leave our active interrupt mask in R7 so the scheduler can}\\
& {\em ; release any tasks that depended upon them. } \\
\end{tabular}
\caption{Example checking for active interrupts}\label{tbl:pre-handler}
\end{center}\end{table}
 
\item Calling the scheduler. This needs to be done to pick the next task
to switch to. It may be an interrupt handler, or it may be a normal
user task. From a priority standpoint, it would make sense that the
2244,54 → 3225,49
\item The idle task, executed when nothing else is able to execute
\end{enumerate}
 
For our purposes here, we'll just assume that a pointer to the current
task is maintained in {\tt R12}, that a {\tt JSR scheduler} is
called, and that the next current task is likewise placed into
{\tt R12}.
% For our purposes here, we'll just assume that a pointer to the current
% task is maintained in {\tt R12}, that a {\tt JSR scheduler} is
% called, and that the next current task is likewise placed into
% {\tt R12}.
 
\item Restore the new tasks context. Given that the scheduler has returned a
task that can be run at this time, the stack pointer needs to be
pulled out of the tasks task structure, placed into the user
register, and then the rest of the user registers need to be popped
back off of the stack to run this task. An example of this is
shown in Tbl.~\ref{tbl:context-in},
task that can be run at this time, the user registers need to be
read from the memory at the user context pointer and then placed into
the user registers. An example of this is shown in
Tbl.~\ref{tbl:context-in},
\begin{table}\begin{center}
\begin{tabular}{ll}
{\tt swap\_in:} \\
& {\tt LOD stack(R12),R5} \\
& {\tt MOV 15(R1),uSP} \\
& {\em ; Be sure to exploit the memory pipelining capability} \\
& {\tt LOD (R5),R0} \\
& {\tt LOD 1(R5),R1} \\
& {\tt LOD 2(R5),R2} \\
& {\tt LOD 3(R5),R3} \\
& {\tt LOD 4(R5),R4} \\
& {\tt MOV R0,uR0} \\
& {\tt MOV R1,uR1} \\
& {\tt MOV R2,uR2} \\
& {\tt MOV R3,uR3} \\
& {\tt MOV R4,uR4} \\
& \ldots {\em ; Need to repeat for all user registers} \\
& {\tt LOD 10(R5),R0} \\
& {\tt LOD 11(R5),R1} \\
& {\tt LOD 12(R5),R2} \\
& {\tt LOD 13(R5),R3} \\
& {\tt LOD 14(R5),R4} \\
& {\tt MOV R0,uR10} \\
& {\tt MOV R1,uR11} \\
& {\tt MOV R2,uR12} \\
& {\tt MOV R3,uCC} \\
& {\tt MOV R4,uPC} \\
\begin{tabbing}
{\tt restore\_context:} \\
\hbox to 0.25in{}\= {\tt SUB 1,SP}\hbox to 0.4in{}\={\em ; Set up a stack frame} \\
\> {\tt STO R5,(SP)} \> {\em ; and store a local register onto it.}\\
\\
\> {\tt LOD (R1),R2} \> {\em ; By doing four loads at a time, we are }\\
\> {\tt LOD 1(R1),R3} \> {\em ; making sure we are using our pipelined}\\
\> {\tt LOD 2(R1),R4} \> {\em ; memory capability. }\\
\> {\tt LOD 3(R1),R5} \\
\> {\tt MOV R2,uR1} \> {\em ; Once the registers are loaded, copy them }\\
\> {\tt MOV R3,uR2} \> {\em ; into the user registers that they need to}\\
\> {\tt MOV R4,uR3} \> {\em ; be placed within.} \\
\> {\tt MOV R5,uR4} \\
\> \ldots {\em ; Need to repeat for all user registers} \\
\> {\tt LOD 12(R1),R2} \> {\em ; Now for our last four registers ...}\\
\> {\tt LOD 13(R5),R3} \\
\> {\tt LOD 14(R5),R4} \\
\> {\tt LOD 15(R5),R5} \\
\> {\tt MOV R2,uR12} \> {\em ; These are the special purpose ones, restored }\\
\> {\tt MOV R3,uSP} \> {\em ; just like any others.}\\
\> {\tt MOV R4,uCC} \\
\> {\tt MOV R5,uPC} \\
 
& {\tt BRA return\_to\_user} \\
\end{tabular}
\> {\tt LOD (SP),R5} \> {\em ; Restore our saved register, } \\
\> {\tt ADD 1,SP} \> {\em ; and the stack frame, }\\
\> {\tt JMP R0} \> {\em ; and return to where we were called from.}\\
\end{tabbing}
\caption{Example Restoring User Task Context}\label{tbl:context-in}
\end{center}\end{table}
assuming as before that the task
pointer is found in supervisor register {\tt R12}.
As with storing the user context, the full code associated with
restoring the user context can be found in the assembler include
file, {\tt sys.i}.
Because this is such an important task, the ZipCPU GCC provides a
built--in function, {\tt zip\_restore\_context(int *)}, which can be
used for this task.
 
\item Clear the userspace accounting registers. In order to keep track of
per process system usage, these registers need to be cleared before
2300,21 → 3276,28
encountered, and how many instructions it was able to issue in
those many clocks.
 
\item Jump back to the instruction just before saving the last tasks context,
because that location in memory contains the return from interrupt
command that we are going to need to execute, in order to guarantee
that we return back here again.
\item Return back to the top of our loop in order to execute {\tt zip\_rtu()}
again.
\end{enumerate}
 
 
\chapter{Registers}\label{chap:regs}
This chapter covers the definitions and locations of the various registers
associated with both the ZipSystem, and the ZipCPU contained within it.
These registers fall into two separate categories: the registers belonging
to the ZipSystem, and then the two debug port registers belonging to the CPU
itself. In this chapter, we'll discuss the ZipSystem peripheral registers
first, followed by the two ZipCPU registers.
 
The ZipSystem registers fall into two categories, ZipSystem internal registers
accessed via the ZipCPU shown in Tbl.~\ref{tbl:zpregs},
 
\section{ZipSystem Peripheral Registers}
The ZipSystem maintains currently maintains 20 register locations, as shown
in Tbl.~\ref{tbl:zpregs}.
\begin{table}[htbp]
\begin{center}\begin{reglist}
PIC & \scalebox{0.8}{\tt 0xc0000000} & 32 & R/W & Primary Interrupt Controller \\\hline
WDT & \scalebox{0.8}{\tt 0xc0000001} & 32 & R/W & Watchdog Timer \\\hline
& \scalebox{0.8}{\tt 0xc0000002} & 32 & R & Address of last bus error \\\hline
WDT & \scalebox{0.8}{\tt 0xc0000001} & 32 & R/W & Watchdog Timer \\\hline
WBU&\scalebox{0.8}{\tt 0xc0000002} & 32 & R & Address of last bus timeout error\\\hline
CTRIC & \scalebox{0.8}{\tt 0xc0000003} & 32 & R/W & Secondary Interrupt Controller \\\hline
TMRA & \scalebox{0.8}{\tt 0xc0000004} & 32 & R/W & Timer A\\\hline
TMRB & \scalebox{0.8}{\tt 0xc0000005} & 32 & R/W & Timer B\\\hline
2334,53 → 3317,55
DMADST & \scalebox{0.8}{\tt 0xc0000013} & 32 & R/W & DMA destination address\\\hline
% Cache & \scalebox{0.8}{\tt 0xc0100000} & & & Base address of the Cache memory\\\hline
\end{reglist}
\caption{Zip System Internal/Peripheral Registers}\label{tbl:zpregs}
\caption{ZipSystem Internal/Peripheral Registers}\label{tbl:zpregs}
\end{center}\end{table}
and the two debug registers shown in Tbl.~\ref{tbl:dbgregs}.
\begin{table}[htbp]
\begin{center}\begin{reglist}
ZIPCTRL & 0 & 32 & R/W & Debug Control Register \\\hline
ZIPDATA & 1 & 32 & R/W & Debug Data Register \\\hline
\end{reglist}
\caption{Zip System Debug Registers}\label{tbl:dbgregs}
\end{center}\end{table}
These registers are located in the CPU's address space, although in a special
area of that space. Indeed, the area is so special, that the CPU decodes
the address space location before placing the request onto the bus. For
this reason, other containers for the CPU, such as the ZipBones which doesn't
have these registers, will still create errors when they are referenced.
 
\section{Peripheral Registers}
The peripheral registers, listed in Tbl.~\ref{tbl:zpregs}, are shown in the
CPU's address space. These may be accessed by the CPU at these addresses,
and when so accessed will respond as described in Chapt.~\ref{chap:periph}.
These registers will be discussed briefly again here.
Here in this section, we'll walk through the definition of each of these
registers in turn, together with any bit fields that may be associated with
them, and how to set those fields.
 
\subsection{Interrupt Controller(s)}
The Zip CPU Interrupt controller has four different types of bits, as shown in
Tbl.~\ref{tbl:picbits}.
Any CPU with only a single interrupt line, such as the ZipCPU, really needs an
interrupt controller to give it access to more than the single interrupt. The
ZipCPU is no different. When the ZipCPU is built as part of the ZipSystem,
this interrupt controller comes integrated into the system.
 
Looking into the bits that define this controller, you can see from
Tbl.~\ref{tbl:picbits},
\begin{table}\begin{center}
\begin{bitlist}
31 & R/W & Master Interrupt Enable\\\hline
30\ldots 16 & R/W & Interrupt Enables, write `1' to change\\\hline
30\ldots 16 & R/W & Interrupt Enable lines\\\hline
15 & R & Current Master Interrupt State\\\hline
15\ldots 0 & R/W & Input Interrupt states, write `1' to clear\\\hline
\end{bitlist}
\caption{Interrupt Controller Register Bits}\label{tbl:picbits}
\end{center}\end{table}
that the ZipCPU Interrupt controller has four different types of bits.
The high order bit, or bit--31, is the master interrupt enable bit. When this
bit is set, then any time an interrupt occurs the CPU will be interrupted and
will switch to supervisor mode, etc.
 
Bits 30~\ldots 16 are interrupt enable bits. Should the interrupt line go
hi while enabled, an interrupt will be generated. (All interrupts are positive
edge triggered.) To set an interrupt enable bit, one needs to write the
master interrupt enable while writing a `1' to this the bit. To clear, one
need only write a `0' to the master interrupt enable, while leaving this line
high.
Bits 30~\ldots 16 are interrupt enable bits. Should the interrupt line ever be
high while enabled, an interrupt will be generated. Further, interrupts are
level triggered. Hence, if the interrupt is cleared while the line feeding
the controller remains high, then the interrupt will re--trip. To set one of
these interrupt enable bits, one needs to write the master interrupt enable
while writing a `1' to this the bit. To clear, one need only write a `0' to
the master interrupt enable, while leaving this line high.
 
Bits 15\ldots 0 are the current state of the interrupt vector. Interrupt lines
trip when they go high, and remain tripped until they are acknowledged. If
the interrupt goes high for longer than one pulse, it may be high when a clear
is requested. If so, the interrupt will not clear. The line must go low
again before the status bit can be cleared.
trip whenever they are high, and remain tripped until the input is lowered and
the interrupt is acknowledged. Thus, if the interrupt line is high when the
controller receives a clear request, then the interrupt will not clear.
The incoming line must go low again before the status bit can be cleared.
 
As an example, consider the following scenario where the Zip CPU supports four
As an example, consider the following scenario where the ZipCPU supports four
interrupts, 3\ldots0.
\begin{enumerate}
\item The Supervisor will first, while in the interrupts disabled mode,
2407,7 → 3392,7
command.
\end{enumerate}
 
\subsection{Timer Register}
\subsection{Timer Register}\label{sec:reg-timer}
 
Leaving the interrupt controller, we show the timer registers bit definitions
in Tbl.~\ref{tbl:tmrbits}.
2427,11 → 3412,10
the auto--reload option was written to it. To clear and stop the timer,
just simply write a `32'h00' to this register.
 
\subsection{Jiffies}
\subsection{Jiffies}\label{sec:reg-jiffies}
 
The Jiffies register is somewhat similar in that the register always changes.
In this case, the register counts up, whereas the timer always counted down.
Reads from this register, as shown in Tbl.~\ref{tbl:jiffybits},
The Jiffies register is first and foremost a counter. It counts up one on
every clock. Reads from this register, as shown in Tbl.~\ref{tbl:jiffybits},
\begin{table}\begin{center}
\begin{bitlist}
31\ldots 0 & R & Current jiffy value\\\hline
2439,18 → 3423,26
\end{bitlist}
\caption{Jiffies Register Bits}\label{tbl:jiffybits}
\end{center}\end{table}
always return the time value contained in the register. Writes greater than
the current Jiffy value, that is where the new value minus the old value is
greater than zero while ignoring truncation, will set a new Jiffy interrupt
time. At that time, the Jiffy vector will clear, and another interrupt time
may either be written to it, or it will just continue counting without
activating any more interrupts.
always return the time value contained in the register.
 
The register accepts writes as well. Writes to the register set the time of
the next Jiffy interrupt. If the next interrupt is between 0~and $2^{31}$
clocks in the past, the peripheral will immediately create an interrupt.
Otherwise, the register will compare the new value against the currently
stored interrupt value. The value nearest in time to the current jiffies value
will be kept, and so the jiffies register will trip at that value. Prior
values are forgotten.
 
When the Jiffy counter value equals the value in its trigger register, then
the jiffies peripheral will trigger an interrupt. At this point, the internal
register is cleared. It will create no more interrupts unless a new value
is written to it.
 
\subsection{Performance Counters}
 
The Zip CPU also supports several counter peripherals, mostly in the way of
process accounting. This peripherals have a single register associated with
them, shown in Tbl.~\ref{tbl:ctrbits}.
The ZipCPU also supports several counter peripherals, mostly for the purpose of
process accounting. These counters each contain a single register, as shown
in Tbl.~\ref{tbl:ctrbits}.
\begin{table}\begin{center}
\begin{bitlist}
31\ldots 0 & R/W & Current counter value\\\hline
2460,14 → 3452,19
Writes to this register set the new counter value. Reads read the current
counter value.
 
The current design operation of these counters is that of performance counting.
These counters can be configured to count upwards upon any event. Using this
capability, eight counters have been assigned the task of performance counting.
Two sets of four registers are available for keeping track of performance.
The first is a task counter. This just counts clock ticks. The second
counter is a prefetch stall counter, then an master stall counter. These
allow the CPU to be evaluated as to how efficient it is. The fourth and
final counter is an instruction counter, which counts how many instructions the
CPU has issued.
The first set tracks master performance, including both supervisor as well as
user CPU statistics. The second set tracks user statistics only, and will not
count in supervisor mode.
 
Of the four registers in each set, the first is a task counter that just counts
clock ticks. The second counter is a prefetch stall counter, then an master
stall counter. These allow the CPU to be evaluated as to how efficient it is.
The fourth and final counter in each set is an instruction counter, which
counts how many instructions the CPU has issued.
 
It is envisioned that these counters will be used as follows: First, every time
a master counter rolls over, the supervisor (Operating System) will record
the fact. Second, whenever activating a user task, the Operating System will
2477,7 → 3474,7
only increment when the GIE bit is set to indicate that the processor is
in user mode.
 
\subsection{DMA Controller}
\subsection{DMA Controller}\label{sec:reg-dmac}
 
The final peripheral to discuss is the DMA controller. This controller
has four registers. Of these four, the length, source and destination address
2491,9 → 3488,10
\begin{table}\begin{center}
\begin{bitlist}
31 & R & DMA Active\\\hline
30 & R & Wishbone error, transaction aborted. This bit is cleared the next time
this register is written to.\\\hline
29 & R/W & Set to `1' to prevent the controller from incrementing the source address, `0' for normal memory copy. \\\hline
30 & R & Wishbone error, transaction aborted. This bit is cleared the next
time this register is written to.\\\hline
29 & R/W & Set to `1' to prevent the controller from incrementing the source
address, `0' for normal memory copy. \\\hline
28 & R/W & Set to `1' to prevent the controller from incrementing the
destination address, `0' for normal memory copy. \\\hline
27 \ldots 16 & W & The DMA Key. Write a 12'hfed to these bits to start the
2504,18 → 3502,18
15 & R/W & Set to `1' to trigger on an interrupt, or `0' to start immediately
upon receiving a valid key.\\\hline
14\ldots 10 & R/W & Select among one of 32~possible interrupt lines.\\\hline
9\ldots 0 & R/W & Intermediate transfer length minus one. Thus, to transfer
one item at a time set this value to 0. To transfer 1024 at a time,
set it to 1023.\\\hline
9\ldots 0 & R/W & Intermediate transfer length. Thus, to transfer
one item at a time set this value to 1. To transfer the maximum number,
1024, at a time set it to 0.\\\hline
\end{bitlist}
\caption{DMA Control Register Bits}\label{tbl:dmacbits}
\end{center}\end{table}
This control register has been designed so that the common case of memory
access need only set the key and the transfer length. Hence, writing a
\hbox{32'h0fed03ff} to the control register will start any memory transfer.
\hbox{32'h0fed0000} to the control register will start any memory transfer.
On the other hand, if you wished to read from a serial port (constant address)
and put the result into a buffer every time a word was available, you
might wish to write \hbox{32'h2fed8000}--this assumes, of course, that you
might wish to write \hbox{32'h2fed8001}--this assumes, of course, that you
have a serial port wired to the zero bit of this interrupt control. (The
DMA controller does not use the interrupt controller, and cannot clear
interrupts.) As a third example, if you wished to write to an external
2523,11 → 3521,19
interrupt line 3 indicated this condition, you might wish to issue a
\hbox{32'h1fed8dff} to this port.
 
\section{Debug Port Registers}
Accessing the Zip System via the debug port isn't as straight forward as
\section{Debug Port Registers}\label{sec:reg-debug}
Accessing the ZipSystem via the debug port isn't as straight forward as
accessing the system via the wishbone bus. The debug port itself has been
reduced to two addresses, as outlined earlier in Tbl.~\ref{tbl:dbgregs}.
Access to the Zip System begins with the Debug Control register, shown in
\begin{table}[htbp]
\begin{center}\begin{reglist}
ZIPCTRL & 0 & 32 & R/W & Debug Control Register \\\hline
ZIPDATA & 1 & 32 & R/W & Debug Data Register \\\hline
\end{reglist}
\caption{ZipSystem Debug Registers}\label{tbl:dbgregs}
\end{center}\end{table}
 
Access to the ZipSystem begins with the Debug Control register, shown in
Tbl.~\ref{tbl:dbgctrl}.
\begin{table}\begin{center}
\begin{bitlist}
2572,7 → 3578,7
uPC & 31 & 32 & R/W & User Program Counter\\\hline
PIC & 32 & 32 & R/W & Primary Interrupt Controller \\\hline
WDT & 33 & 32 & R/W & Watchdog Timer\\\hline
BUS & 34 & 32 & R & Last Bus Error\\\hline
WBUS & 34 & 32 & R & Last Bus Error\\\hline
CTRIC & 35 & 32 & R/W & Secondary Interrupt Controller\\\hline
TMRA & 36 & 32 & R/W & Timer A\\\hline
TMRB & 37 & 32 & R/W & Timer B\\\hline
2614,7 → 3620,7
To leave this debug mode, simply write a `32'h0' value to the command register.
 
\chapter{Wishbone Datasheets}\label{chap:wishbone}
The Zip System supports two wishbone ports, a slave debug port and a master
The ZipSystem supports two wishbone ports, a slave debug port and a master
port for the system itself. These are shown in Tbl.~\ref{tbl:wishbone-slave}
\begin{table}[htbp]
\begin{center}
2632,7 → 3638,7
Signal Name & Wishbone Equivalent \\\hline
{\tt i\_clk} & {\tt CLK\_I} \\
{\tt i\_dbg\_cyc} & {\tt CYC\_I} \\
{\tt i\_dbg\_stb} & {\tt STB\_I} \\
{\tt i\_dbg\_stb} & {\tt (CYC\_I)\&(STB\_I)} \\
{\tt i\_dbg\_we} & {\tt WE\_I} \\
{\tt i\_dbg\_addr} & {\tt ADR\_I} \\
{\tt i\_dbg\_data} & {\tt DAT\_I} \\
2649,7 → 3655,7
\begin{wishboneds}
Revision level of wishbone & WB B4 spec \\\hline
Type of interface & Master, Read/Write, single cycle or pipelined\\\hline
Address Width & (Zip System parameter, can be up to 32--bit bits) \\\hline
Address Width & (ZipSystem parameter, can be up to 32--bit bits) \\\hline
Port size & 32--bit \\\hline
Port granularity & 32--bit \\\hline
Maximum Operand Size & 32--bit \\\hline
2660,7 → 3666,7
Signal Name & Wishbone Equivalent \\\hline
{\tt i\_clk} & {\tt CLK\_O} \\
{\tt o\_wb\_cyc} & {\tt CYC\_O} \\
{\tt o\_wb\_stb} & {\tt STB\_O} \\
{\tt o\_wb\_stb} & {\tt (CYC\_O)\&(STB\_O)} \\
{\tt o\_wb\_we} & {\tt WE\_O} \\
{\tt o\_wb\_addr} & {\tt ADR\_O} \\
{\tt o\_wb\_data} & {\tt DAT\_O} \\
2672,26 → 3678,41
\end{wishboneds}
\caption{Wishbone Datasheet for the CPU as Master}\label{tbl:wishbone-master}
\end{center}\end{table}
I do not recommend that you connect these together through the interconnect.
I do not recommend that you connect these together through the interconnect,
since 1) it doesn't make sense that the CPU should be able to halt itself,
and 2) it helps to be able to reboot the CPU in case something has gone
terribly wrong and the CPU is stalling the entire interconnect.
Rather, the debug port of the CPU should be accessible regardless of the state
of the master bus.
 
You may wish to notice that neither the {\tt LOCK} nor the {\tt RTY} (retry)
wires have been connected to the CPU's master interface. If necessary, a
rudimentary {\tt LOCK} may be created by tying the wire to the {\tt wb\_cyc}
rudimentary {\tt LOCK} may be created by tying this wire to the {\tt wb\_cyc}
line. As for the {\tt RTY}, all the CPU recognizes at this point are bus
errors---it cannot tell the difference between a temporary and a permanent bus
error.
error. Therefore, one might logically OR the bus error and bus retry flags on
input to the CPU if necessary.
 
The final simplification made of the standard wishbone bus B4 specification, is
that the strobe lines are assumed to be zero in any slave if {\tt CYC\_I} is
zero, and the master is responsible for ensuring that {\tt STB\_O} is never
true when {\tt CYC\_O} is true in order to make this work. All of the ZipCPU
and ZipSystem masters and peripherals have been created with this assumption.
Converting peripherals that have made this assumption to work with masters
that don't guarantee this property is as simple as anding the slave's
{\tt CYC\_I} and {\tt STB\_I} lines together. No change needs to be made to
any ZipCPU master, however, in order to access any peripheral that hasn't been
so simplified.
 
\chapter{Clocks}\label{chap:clocks}
 
This core is based upon the Basys--3 development board sold by Digilent.
The Basys--3 development board contains one external 100~MHz clock, which is
sufficient to run the Zip CPU core.
This core has now been tested and proven on the Xilinx Spartan~6 FPGA as well
as the Artix--7 FPGA.
\begin{table}[htbp]
\begin{center}
\begin{clocklist}
i\_clk & External & 100~MHz & 100~MHz & System clock.\\\hline
i\_clk & External & 100~MHz & & System clock, Artix--7/35T\\\hline
& & 80~MHz & & System clock, Spartan 6\\\hline
\end{clocklist}
\caption{List of Clocks}\label{tbl:clocks}
\end{center}\end{table}
2701,8 → 3722,15
 
On a SPARTAN 6, the clock can run successfully at 80~MHz.
 
A second Artix--7 design on the Digilent's Arty board is limited to 81.25~MHz
by the memory interface generated core used to access SDRAM.
 
\chapter{I/O Ports}\label{chap:ioports}
The I/O ports to the Zip CPU may be grouped into three categories. The first
This chapter presents and outlines the various I/O lines in and out of the
ZipSystem. Since the ZipCPU needs to be a component of such a larger part,
this makes sense.
 
The I/O ports to the ZipSystem may be grouped into three categories. The first
is that of the master wishbone used by the CPU, then the slave wishbone used
to command the CPU via a debugger, and then the rest. The first two of these
were already discussed in the wishbone chapter. They are listed here
2722,14 → 3750,14
and~\ref{tbl:iowb-slave} respectively.
\begin{table}
\begin{center}\begin{portlist}
{\tt i\_wb\_cyc} & 1 & Input & Indicates an active Wishbone cycle\\\hline
{\tt i\_wb\_stb} & 1 & Input & WB Strobe signal\\\hline
{\tt i\_wb\_we} & 1 & Input & Write enable\\\hline
{\tt i\_wb\_addr} & 1 & Input & Bus address, command or data port \\\hline
{\tt i\_wb\_data} & 32 & Input & Data on WB write\\\hline
{\tt o\_wb\_ack} & 1 & Output & Slave has completed a R/W cycle\\\hline
{\tt o\_wb\_stall} & 1 & Output & WB bus slave not ready\\\hline
{\tt o\_wb\_data} & 32 & Output & Incoming bus data\\\hline
{\tt i\_dbg\_cyc} & 1 & Input & Indicates an active Wishbone cycle\\\hline
{\tt i\_dbg\_stb} & 1 & Input & WB Strobe signal\\\hline
{\tt i\_dbg\_we} & 1 & Input & Write enable\\\hline
{\tt i\_dbg\_addr} & 1 & Input & Bus address, command or data port \\\hline
{\tt i\_dbg\_data} & 32 & Input & Data on WB write\\\hline
{\tt o\_dbg\_ack} & 1 & Output & Slave has completed a R/W cycle\\\hline
{\tt o\_dbg\_stall} & 1 & Output & WB bus slave not ready\\\hline
{\tt o\_dbg\_data} & 32 & Output & Incoming bus data\\\hline
\end{portlist}\caption{CPU Debug Wishbone I/O Ports}\label{tbl:iowb-slave}\end{center}\end{table}
 
There are only four other lines to the CPU: the external clock, external
2740,45 → 3768,64
{\tt i\_clk} & 1 & Input & The master CPU clock \\\hline
{\tt i\_rst} & 1 & Input & Active high reset line \\\hline
{\tt i\_ext\_int} & 1\ldots 16 & Input & Incoming external interrupts, actual
value set by implementation parameter \\\hline
value set by implementation parameter. This is only ever one
for the ZipBones implementation.\\\hline
{\tt o\_ext\_int} & 1 & Output & CPU Halted interrupt \\\hline
\end{portlist}\caption{I/O Ports}\label{tbl:ioports}\end{center}\end{table}
The clock line was discussed briefly in Chapt.~\ref{chap:clocks}. We
typically run it at 100~MHz, although we've needed to slow it down to 80~MHz
for some implementations. The reset line is an active high reset. When
asserted, the CPU will start running again from its reset address in
The clock line was discussed briefly in Chapt.~\ref{chap:clocks}. The reset
line is an active high reset. When
asserted, the CPU will start running again from its {\tt RESET\_ADDRESS} in
memory. Further, depending upon how the CPU is configured and specifically
based upon how the {\tt START\_HALTED} parameter is set, the CPU may or may
not start running automatically following a reset. The {\tt i\_ext\_int}
line is for an external interrupt. This line may actually be as wide as
16~external interrupts, depending upon the setting of
the {\tt EXTERNAL\_INTERRUPTS} parameter. Finally, the Zip System produces one
bus is for set of external interrupt lines to the ZipSystem. This line may
actually be as wide as 16~external interrupts, depending upon the setting of
the {\tt EXTERNAL\_INTERRUPTS} parameter. Finally, the ZipSystem produces one
external interrupt whenever the entire CPU halts to wait for the debugger.
 
The I/O lines to the ZipBones package are identical to those of the ZipSystem,
with the only exception that the ZipBones package has only a single interrupt
line input. This means that the ZipBones implementation practically depends
upon an external interrupt controller.
 
\chapter{Initial Assessment}\label{chap:assessment}
 
Having now worked with the Zip CPU for a while, it is worth offering an
Having now worked with the ZipCPU for a while, it is worth offering an
honest assessment of how well it works and how well it was designed. At the
end of this assessment, I will propose some changes that may take place in a
later version of this Zip CPU to make it better.
later version of this ZipCPU to make it better.
 
\section{The Good}
\begin{itemize}
\item The Zip CPU can be configured to be relatively light weight and fully
featured as it exists today. For anyone who wishes to build a general
purpose CPU and then to experiment with building and adding particular
features, the Zip CPU makes a good starting point--it is fairly simple.
Modifications should be simple enough. Indeed, a non--pipelined
version of the bare ZipBones (with no peripherals) has been built that
only uses 1.1k~LUTs. When using pipelining, the full cache, and all
of the peripherals, the ZipSystem can top 5~k LUTs. Where it fits
in between is a function of your needs.
\item The Zip CPU was designed to be an implementable soft core that could be
\item The ZipCPU was designed to be a simple and light weight CPU. It has
achieved this end nicely. The proof of this is the full multitasking
operating system built for Digilent's CMod S6 board, based around
a very small Spartan~6/LX4 FPGA.
 
As a result, the ZipCPU also makes a good starting point for anyone
who wishes to build a general purpose CPU and then to experiment with
building and adding particular features. Modifications should be
simple enough.
 
Indeed, a non--pipelined version of the bare ZipBones (with no
peripherals) has been built that only uses 1.3k~6--LUTs. When using
pipelining, the full cache, and all of the peripherals, the ZipSystem
can take up to 4.5~k LUTs. Where it fits in between is a function of
your needs.
 
A new implementation using an iCE40 FPGA suggests that the ZipCPU
will fit within the 4k~4--way LUTs of the iCE40 HK4X FPGA, but only
just barely.
 
\item The ZipCPU was designed to be an implementable soft core that could be
placed within an FPGA, controlling actions internal to the FPGA. It
fits this role rather nicely. It does not fit the role of a system on
a chip very well, but then it was never intended to be a system on a
chip but rather a system within a chip.
\item The extremely simplified instruction set of the Zip CPU was a good
fits this role rather nicely. It does not fit the role of a general
purpose CPU replacement very well: it has no octet level access,
no double--precision floating point capability, neither does it have
vector registers and operations. However, it was never designed to be
such a general purpose CPU but rather a system within a chip.
 
\item The extremely simplified instruction set of the ZipCPU was a good
choice. Although it does not have many of the commonly used
instructions, PUSH, POP, JSR, and RET among them, the simplified
instruction set has demonstrated an amazing versatility. I will contend
2789,17 → 3836,23
\item This simplified instruction set is easy to decode.
\item The simplified bus transactions (32-bit words only) were also very easy
to implement.
\item The pipelined load/store approach is novel, and can be used to greatly
increase the speed of the processor.
\item The novel approach of having a single interrupt vector, which just
brings the CPU back to the instruction it left off at within the last
interrupt context doesn't appear to have been that much of a problem.
If most modern systems handle interrupt vectoring in software anyway,
why maintain hardware support for it?
\item The burst load/store approach using the wishbone pipelining mode is
novel, and can be used to greatly increase the speed of the processor.
\item The novel approach to interrupts greatly facilitates the development of
interrupt handlers from within high level languages.
 
The approach involves a single interrupt ``vector'' only, and simply
switches the CPU back to the instruction it left off at. By using
this approach, interrupt handlers no longer need careful assembly
language scripting in order to save their context upon any interrupt.
 
At the same time, if most modern systems handle interrupt vectoring in
software anyway, why maintain complicated hardware support for it?
 
\item My goal of a high rate of instructions per clock may not be the proper
measure. For example, if instructions are being read from a SPI flash
device, such as is common among FPGA implementations, these same
instructions may suffer stalls of between 64 and 128 cycles per
measure of this CPU. For example, if instructions are being read from a
SPI flash device, such as is common among FPGA implementations, these
same instructions may suffer stalls of between 64 and 128 cycles per
instruction just to read the instruction from the flash. Executing the
instruction in a single clock cycle is no longer the appropriate
measure. At the same time, it should be possible to use the DMA
2806,81 → 3859,112
peripheral to copy instructions from the FLASH to a temporary memory
location, after which they may be executed at a single instruction
cycle per access again.
 
\item Both GCC and binutils back ends exist for the ZipCPU.
\end{itemize}
 
\section{The Not so Good}
\begin{itemize}
\item The CPU has no character support. This is both good and bad.
\item The CPU has no octet (character) support. This is both good and bad.
Realistically, the CPU works just fine without it. Characters can be
supported as subsets of 32-bit words without any problem. Practically,
though, it will make compiling non-Zip CPU code difficult--especially
anything that assumes sizeof(int)=4*sizeof(char), or that tries to
though, this creates two problems. The first is that it makes porting
code from non-ZipCPU platforms to the ZipCPU is difficult--especially
anything that depends upon the existence of {\tt *int8\_t},
{\tt *int16\_t}, the size difference between
{\tt sizeof(int)=4*sizeof(char)}, or that tries to
create unions with characters and integers and then attempts to
reference the address of the characters within that union.
reference the address of the characters within that union.
 
\item The Zip CPU does not support a data cache. One can still be built
externally, but this is a limitation of the CPU proper as built.
Further, under the theory of the Zip CPU design (that of an embedded
soft-core processor within an FPGA, where any ``address'' may reference
either memory or a peripheral that may have side-effects), any data
cache would need to be based upon an initial knowledge of whether or
not it is supporting memory (cachable) or peripherals. This knowledge
must exist somewhere, and that somewhere is currently (and by design)
external to the CPU.
The second problem is that peripherals that depend upon character
support on the bus may need to be rewritten to work on a 32--bit bus.
 
This may also be written off as a ``feature'' of the Zip CPU, since
the addition of a data cache can greatly increase the LUT count of
a soft core.
\item The ZipCPU does not (yet) support a data cache. One is currently under
development.
 
The Zip CPU compensates for this via its pipelined load and store
instructions.
The ZipCPU compensates for this lack via its burst memory capability.
Further, performance tests using Dhrystone suggest that the ZipCPU is
no slower than other processors containing a data cache.
 
\item Many other instruction sets offer three operand instructions, whereas
the Zip CPU only offers two operand instructions. This means that it
takes the Zip CPU more instructions to do many of the same operations.
The good part of this is that it gives the Zip CPU a greater amount of
the ZipCPU only offers two operand instructions. This means that it
may take the ZipCPU more instructions to do many of the same operations.
The good part of this is that it gives the ZipCPU a greater amount of
flexibility in its immediate operand mode, although that increased
flexibility isn't necessarily as valuable as one might like.
 
\item The Zip CPU doesn't support out of order execution. I suppose it could
be modified to do so, but then it would no longer be the ``simple''
and low LUT count CPU it was designed to be. The two primary results
are that 1) loads may unnecessarily stall the CPU, even if other
things could be done while waiting for the load to complete, 2)
bus errors on stores will never be caught at the point of the error,
and 3) branch prediction becomes more difficult.
The impact of this lack of three operand instructions is application
dependent, but does not appear to be too severe.
 
\item Although switching to an interrupt context in the Zip CPU design doesn't
\item The ZipCPU doesn't support out of order execution.
 
I suppose it could be modified to do so, but then it would no longer
be the ``simple'' and low LUT count CPU it was designed to be.
 
\item Although switching to an interrupt context in the ZipCPU design doesn't
require a tremendous swapping of registers, in reality it still
does--since any task swap still requires saving and restoring all
16~user registers. That's a lot of memory movement just to service
an interrupt.
does--since any task swap (such as swapping to a task waiting on an
interrupt) still requires saving and restoring all 16~user registers.
That's a lot of memory movement just to service an interrupt.
 
\item The Zip CPU is by no means generic: it will never handle addresses
larger than 32-bits (16GB) without a complete and total redesign.
This isn't nearly as bad as it sounds, however, since most RISC
architectures have 32~registers that will need to be swapped upon any
context swap.
 
\item The ZipCPU is by no means generic: it will never handle addresses
larger than 32-bits (4GW or 16GB) without a complete and total redesign.
This may limit its utility as a generic CPU in the future, although
as an embedded CPU within an FPGA this isn't really much of a limit
or restriction.
as an embedded CPU within an FPGA this isn't really much of a
restriction.
 
\item While the Zip CPU has its own assembler, it has no linker and does not
(yet) support a compiler. The standard C library is an even longer
shot. My dream of having binutils and gcc support has not been
realized and at this rate may not be realized. (I've been intimidated
by the challenge everytime I've looked through those codes.)
\item While a toolchain does exist for the ZipCPU, it isn't yet fully featured.
The ZipCPU has no support for soft floating point arithmetic,
nor does it have support for several standard library functions.
Indeed, full C library support and gdb support are still lacking.
\end{itemize}
 
\section{The Next Generation}
This section could also be labeled as my ``To do'' list. Today's list is
much different than it was for the last version of this document, as much of
the prior to do list (such as VLIW instructions, and a more traditional
instruction cache) has now been implemented. The only things really and
truly waiting on my list today are assembler support for the VLIW instruction
set, linker and compiler support.
This section could also be labeled as my ``To do'' list. It outlines where
you may expect features in the future. Currently, there are five primary
items on my to do list:
\begin{enumerate}
\item Soft Floating Point capability
 
Stay tuned, these are likely to be coming next.
The lack of any floating point capability, either hard or soft, makes
porting math software to the ZipCPU difficult. Simply building a
soft floating point library will solve this problem.
 
% Appendices
% Index
\item A C library.
 
The lack of octet support has so far prevented the porting of
newlib to the ZipCPU platform. In the end, it may mean that any
C library implementation for the ZipCPU may be subtly different
from any you are familiar with.
 
\item A data cache
 
A preliminary data cache implemented as a write through cache has
been developed. Adding this into the CPU should require few changes
internal to the CPU. I expect future versions of the CPU will permit
this as an option.
 
\item A Memory Management Unit
 
The first version of such an MMU has already been written. It is
available for examination in the ZipCPU repository. This MMU exists
as a peripheral of the ZipCPU. Integrating this MMU into the ZipCPU
will involve slowing down memory stores so that they can be accomplished
synchronously, as well as determining how and when particular cache
lines need to be invalidated.
 
\item An integrated floating point unit (FPU)
 
Why a small scale CPU needs a hefty floating point unit, I'm not
certain, but many application contexts require the ability to do
floating point math.
\end{enumerate}
 
 
\end{document}
 
%

powered by: WebSVN 2.1.0

© copyright 1999-2024 OpenCores.org, equivalent to Oliscience, all rights reserved. OpenCores®, registered trademark.