URL
https://opencores.org/ocsvn/openrisc_2011-10-31/openrisc_2011-10-31/trunk
Subversion Repositories openrisc_2011-10-31
[/] [openrisc/] [trunk/] [rtos/] [ecos-2.0/] [doc/] [html/] [ref/] [fis-create-command.html] - Rev 482
Go to most recent revision | Compare with Previous | Blame | View Log
<!-- Copyright (C) 2003 Red Hat, Inc. --> <!-- This material may be distributed only subject to the terms --> <!-- and conditions set forth in the Open Publication License, v1.0 --> <!-- or later (the latest version is presently available at --> <!-- http://www.opencontent.org/openpub/). --> <!-- Distribution of the work or derivative of the work in any --> <!-- standard (paper) book form is prohibited unless prior --> <!-- permission is obtained from the copyright holder. --> <HTML ><HEAD ><TITLE >fis create</TITLE ><meta name="MSSmartTagsPreventParsing" content="TRUE"> <META NAME="GENERATOR" CONTENT="Modular DocBook HTML Stylesheet Version 1.76b+ "><LINK REL="HOME" TITLE="eCos Reference Manual" HREF="ecos-ref.html"><LINK REL="UP" TITLE="Flash Image System (FIS)" HREF="flash-image-system.html"><LINK REL="PREVIOUS" TITLE="fis free" HREF="fis-free-command.html"><LINK REL="NEXT" TITLE="fis load" HREF="fis-load-command.html"></HEAD ><BODY CLASS="REFENTRY" BGCOLOR="#FFFFFF" TEXT="#000000" LINK="#0000FF" VLINK="#840084" ALINK="#0000FF" ><DIV CLASS="NAVHEADER" ><TABLE SUMMARY="Header navigation table" WIDTH="100%" BORDER="0" CELLPADDING="0" CELLSPACING="0" ><TR ><TH COLSPAN="3" ALIGN="center" >eCos Reference Manual</TH ></TR ><TR ><TD WIDTH="10%" ALIGN="left" VALIGN="bottom" ><A HREF="fis-free-command.html" ACCESSKEY="P" >Prev</A ></TD ><TD WIDTH="80%" ALIGN="center" VALIGN="bottom" ></TD ><TD WIDTH="10%" ALIGN="right" VALIGN="bottom" ><A HREF="fis-load-command.html" ACCESSKEY="N" >Next</A ></TD ></TR ></TABLE ><HR ALIGN="LEFT" WIDTH="100%"></DIV ><H1 ><A NAME="FIS-CREATE-COMMAND">fis create</H1 ><DIV CLASS="REFNAMEDIV" ><A NAME="AEN4008" ></A ><H2 >Name</H2 >fis create -- Create flash image</DIV ><DIV CLASS="REFSYNOPSISDIV" ><A NAME="AEN4011"><H2 >Synopsis</H2 ><P ><B CLASS="COMMAND" >fis create</B > {-b <TT CLASS="REPLACEABLE" ><I > data address</I ></TT >} {-l <TT CLASS="REPLACEABLE" ><I > length</I ></TT >} [-f <TT CLASS="REPLACEABLE" ><I > flash address</I ></TT >] [-e <TT CLASS="REPLACEABLE" ><I > entry</I ></TT >] [-r <TT CLASS="REPLACEABLE" ><I > relocation address</I ></TT >] [-s <TT CLASS="REPLACEABLE" ><I > data length</I ></TT >] [-n ] [<TT CLASS="REPLACEABLE" ><I >name</I ></TT >]</P ></DIV ><DIV CLASS="REFSECT1" ><A NAME="AEN4029" ></A ><H2 >Arguments</H2 ><DIV CLASS="INFORMALTABLE" ><A NAME="AEN4031"><P ></P ><TABLE BORDER="1" CLASS="CALSTABLE" ><THEAD ><TR ><TH WIDTH="25%" ALIGN="LEFT" VALIGN="TOP" >Name</TH ><TH WIDTH="25%" ALIGN="LEFT" VALIGN="TOP" >Type</TH ><TH WIDTH="25%" ALIGN="LEFT" VALIGN="TOP" >Description</TH ><TH WIDTH="25%" ALIGN="LEFT" VALIGN="TOP" >Default</TH ></TR ></THEAD ><TBODY ><TR ><TD WIDTH="25%" ALIGN="LEFT" VALIGN="TOP" >-b</TD ><TD WIDTH="25%" ALIGN="LEFT" VALIGN="TOP" >Number</TD ><TD WIDTH="25%" ALIGN="LEFT" VALIGN="TOP" >Address of data to be written to the flash.</TD ><TD WIDTH="25%" ALIGN="LEFT" VALIGN="TOP" >Address of last loaded file. If not set in a load operation, it must be specified.</TD ></TR ><TR ><TD WIDTH="25%" ALIGN="LEFT" VALIGN="TOP" >-l</TD ><TD WIDTH="25%" ALIGN="LEFT" VALIGN="TOP" >Number</TD ><TD WIDTH="25%" ALIGN="LEFT" VALIGN="TOP" >Length of flash area to occopy. If specified, and the named image already exists, the length must match the value in the FIS directory.</TD ><TD WIDTH="25%" ALIGN="LEFT" VALIGN="TOP" >Length of area reserved in FIS directory if the image already exists, or the length of the last loaded file. If neither are set, it must be specified.</TD ></TR ><TR ><TD WIDTH="25%" ALIGN="LEFT" VALIGN="TOP" >-f</TD ><TD WIDTH="25%" ALIGN="LEFT" VALIGN="TOP" >Number</TD ><TD WIDTH="25%" ALIGN="LEFT" VALIGN="TOP" >Address of flash area to occopy.</TD ><TD WIDTH="25%" ALIGN="LEFT" VALIGN="TOP" >The address of an area reserved in the FIS directory for extant images. Otherwise the first free block which is large enough will be used.</TD ></TR ><TR ><TD WIDTH="25%" ALIGN="LEFT" VALIGN="TOP" >-e</TD ><TD WIDTH="25%" ALIGN="LEFT" VALIGN="TOP" >Number</TD ><TD WIDTH="25%" ALIGN="LEFT" VALIGN="TOP" >Entry address for an executable image, used by the <B CLASS="COMMAND" >fis load</B > command.</TD ><TD WIDTH="25%" ALIGN="LEFT" VALIGN="TOP" >The entry address of last loaded file.</TD ></TR ><TR ><TD WIDTH="25%" ALIGN="LEFT" VALIGN="TOP" >-r</TD ><TD WIDTH="25%" ALIGN="LEFT" VALIGN="TOP" >Number</TD ><TD WIDTH="25%" ALIGN="LEFT" VALIGN="TOP" >Address where the image should be relocated to by the <B CLASS="COMMAND" >fis load</B > command. This is only relevant for images that will be loaded with the <B CLASS="COMMAND" >fis load</B > command.</TD ><TD WIDTH="25%" ALIGN="LEFT" VALIGN="TOP" >The load address of the last loaded file.</TD ></TR ><TR ><TD WIDTH="25%" ALIGN="LEFT" VALIGN="TOP" >-s</TD ><TD WIDTH="25%" ALIGN="LEFT" VALIGN="TOP" >Number</TD ><TD WIDTH="25%" ALIGN="LEFT" VALIGN="TOP" >Actual length of data written to image. This is used to control the range over which the checksum is made.</TD ><TD WIDTH="25%" ALIGN="LEFT" VALIGN="TOP" >It defaults to the length of the last loaded file.</TD ></TR ><TR ><TD WIDTH="25%" ALIGN="LEFT" VALIGN="TOP" >-n</TD ><TD WIDTH="25%" ALIGN="LEFT" VALIGN="TOP" > </TD ><TD WIDTH="25%" ALIGN="LEFT" VALIGN="TOP" >When set, no image data will be written to the flash. Only the FIS directory will be updated.</TD ><TD WIDTH="25%" ALIGN="LEFT" VALIGN="TOP" > </TD ></TR ><TR ><TD WIDTH="25%" ALIGN="LEFT" VALIGN="TOP" ><TT CLASS="REPLACEABLE" ><I >name</I ></TT ></TD ><TD WIDTH="25%" ALIGN="LEFT" VALIGN="TOP" >String</TD ><TD WIDTH="25%" ALIGN="LEFT" VALIGN="TOP" >Name of flash image.</TD ><TD WIDTH="25%" ALIGN="LEFT" VALIGN="TOP" > </TD ></TR ></TBODY ></TABLE ><P ></P ></DIV ></DIV ><DIV CLASS="REFSECT1" ><A NAME="AEN4088" ></A ><H2 >Description</H2 ><P >This command creates an image in the FIS directory. The data for the image must exist in RAM memory before the copy. Typically, you would use the RedBoot <B CLASS="COMMAND" >load</B > command to load file into RAM and then the <B CLASS="COMMAND" >fis create</B > command to write it to a flash image.</P ></DIV ><DIV CLASS="REFSECT1" ><A NAME="AEN4093" ></A ><H2 >Examples</H2 ><P >Trying to create an extant image, will require the action to be verified. <TABLE BORDER="5" BGCOLOR="#E0E0F0" WIDTH="70%" ><TR ><TD ><PRE CLASS="SCREEN" >RedBoot> <TT CLASS="USERINPUT" ><B >fis create RedBoot -f 0xa0000000 -b 0x8c400000 -l 0x20000</B ></TT > An image named ‘RedBoot’ exists - continue (y/n)? <TT CLASS="USERINPUT" ><B >n</B ></TT ></PRE ></TD ></TR ></TABLE ></P ><P >Create a new test image, let the command find a suitable place. <TABLE BORDER="5" BGCOLOR="#E0E0F0" WIDTH="70%" ><TR ><TD ><PRE CLASS="SCREEN" >RedBoot> <TT CLASS="USERINPUT" ><B >fis create junk -b 0x8c400000 -l 0x20000</B ></TT > ... Erase from 0xa0040000-0xa0060000: . ... Program from 0x8c400000-0x8c420000 at 0xa0040000: . ... Erase from 0xa0fe0000-0xa1000000: . ... Program from 0x8c7d0000-0x8c7f0000 at 0xa0fe0000: .</PRE ></TD ></TR ></TABLE ></P ><P >Update the RedBoot[RAM] image. <TABLE BORDER="5" BGCOLOR="#E0E0F0" WIDTH="70%" ><TR ><TD ><PRE CLASS="SCREEN" >RedBoot> <TT CLASS="USERINPUT" ><B >load redboot_RAM.img</B ></TT > Entry point: 0x060213c0, address range: 0x06020000-0x06036cc0 RedBoot> <TT CLASS="USERINPUT" ><B >fis create RedBoot[RAM]</B ></TT > No memory address set. An image named 'RedBoot[RAM]' exists - continue (y/n)? <TT CLASS="USERINPUT" ><B >y</B ></TT > * CAUTION * about to program 'RedBoot[RAM]' at 0x00020000..0x00036cbf from 0x06020000 - continue (y/n)? <TT CLASS="USERINPUT" ><B >y</B ></TT > ... Erase from 0x00020000-0x00040000: .. ... Program from 0x06020000-0x06036cc0 at 0x00020000: .. ... Erase from 0x00070000-0x00080000: . ... Program from 0x0606f000-0x0607f000 at 0x00070000: .</PRE ></TD ></TR ></TABLE ></P ></DIV ><DIV CLASS="NAVFOOTER" ><HR ALIGN="LEFT" WIDTH="100%"><TABLE SUMMARY="Footer navigation table" WIDTH="100%" BORDER="0" CELLPADDING="0" CELLSPACING="0" ><TR ><TD WIDTH="33%" ALIGN="left" VALIGN="top" ><A HREF="fis-free-command.html" ACCESSKEY="P" >Prev</A ></TD ><TD WIDTH="34%" ALIGN="center" VALIGN="top" ><A HREF="ecos-ref.html" ACCESSKEY="H" >Home</A ></TD ><TD WIDTH="33%" ALIGN="right" VALIGN="top" ><A HREF="fis-load-command.html" ACCESSKEY="N" >Next</A ></TD ></TR ><TR ><TD WIDTH="33%" ALIGN="left" VALIGN="top" >fis free</TD ><TD WIDTH="34%" ALIGN="center" VALIGN="top" ><A HREF="flash-image-system.html" ACCESSKEY="U" >Up</A ></TD ><TD WIDTH="33%" ALIGN="right" VALIGN="top" >fis load</TD ></TR ></TABLE ></DIV ></BODY ></HTML >
Go to most recent revision | Compare with Previous | Blame | View Log