OpenCores
URL https://opencores.org/ocsvn/System09/System09/trunk

Subversion Repositories System09

[/] [System09/] [branches/] [mkfiles_rev1/] [rtl/] [System09_Xilinx_ML506/] [ml50x_U1_fpga.ucf] - Blame information for rev 104

Go to most recent revision | Details | Compare with Previous | View Log

Line No. Rev Author Line
1 56 davidgb
NET  AUDIO_BIT_CLK        LOC="AF18";  # Bank 4, Vcco=3.3V, No DCI
2
NET  AUDIO_SDATA_IN       LOC="AE18";  # Bank 4, Vcco=3.3V, No DCI
3
NET  AUDIO_SDATA_OUT      LOC="AG16";  # Bank 4, Vcco=3.3V, No DCI
4
NET  AUDIO_SYNC           LOC="AF19";  # Bank 4, Vcco=3.3V, No DCI
5
NET  BUS_ERROR_1          LOC="F6";    # Bank 12, Vcco=3.3V, DCI using 49.9 ohm resistors
6
NET  BUS_ERROR_2          LOC="T10";   # Bank 12, Vcco=3.3V, DCI using 49.9 ohm resistors
7
NET  CFG_ADDR_OUT0        LOC="AE12";  # Bank 2, Vcco=3.3V
8
NET  CFG_ADDR_OUT1        LOC="AE13";  # Bank 2, Vcco=3.3V
9
NET  CLK_27MHZ_FPGA       LOC="AG18";  # Bank 4, Vcco=3.3V, No DCI
10
NET  CLK_33MHZ_FPGA       LOC="AH17";  # Bank 4, Vcco=3.3V, No DCI
11
NET  CLK_FPGA_N           LOC="K19";   # Bank 3, Vcco=2.5V, No DCI
12
NET  CLK_FPGA_P           LOC="L19";   # Bank 3, Vcco=2.5V, No DCI
13
NET  CLKBUF_Q0_N          LOC="H3";    # Bank 116, MGTREFCLKN_116, GTP_DUAL_X0Y4
14
NET  CLKBUF_Q0_P          LOC="H4";    # Bank 116, MGTREFCLKP_116, GTP_DUAL_X0Y4
15
NET  CLKBUF_Q1_N          LOC="J19";   # Bank 3, Vcco=2.5V, No DCI
16
NET  CLKBUF_Q1_P          LOC="K18";   # Bank 3, Vcco=2.5V, No DCI
17
NET  CPLD_IO_1            LOC="W10";   # Bank 18, Vcco=3.3V, No DCI
18
NET  CPU_TCK              LOC="E6";    # Bank 12, Vcco=3.3V, DCI using 49.9 ohm resistors
19
NET  CPU_TDO              LOC="E7";    # Bank 12, Vcco=3.3V, DCI using 49.9 ohm resistors
20
NET  CPU_TMS              LOC="U10";   # Bank 12, Vcco=3.3V, DCI using 49.9 ohm resistors
21
NET  CPU_TRST             LOC="V10";   # Bank 18, Vcco=3.3V, No DCI
22
NET  DDR2_A0              LOC="L30";   # Bank 15, Vcco=1.8V, DCI using 49.9 ohm resistors
23
NET  DDR2_A1              LOC="M30";   # Bank 15, Vcco=1.8V, DCI using 49.9 ohm resistors
24
NET  DDR2_A2              LOC="N29";   # Bank 15, Vcco=1.8V, DCI using 49.9 ohm resistors
25
NET  DDR2_A3              LOC="P29";   # Bank 15, Vcco=1.8V, DCI using 49.9 ohm resistors
26
NET  DDR2_A4              LOC="K31";   # Bank 15, Vcco=1.8V, DCI using 49.9 ohm resistors
27
NET  DDR2_A5              LOC="L31";   # Bank 15, Vcco=1.8V, DCI using 49.9 ohm resistors
28
NET  DDR2_A6              LOC="P31";   # Bank 15, Vcco=1.8V, DCI using 49.9 ohm resistors
29
NET  DDR2_A7              LOC="P30";   # Bank 15, Vcco=1.8V, DCI using 49.9 ohm resistors
30
NET  DDR2_A8              LOC="M31";   # Bank 15, Vcco=1.8V, DCI using 49.9 ohm resistors
31
NET  DDR2_A9              LOC="R28";   # Bank 15, Vcco=1.8V, DCI using 49.9 ohm resistors
32
NET  DDR2_A10             LOC="J31";   # Bank 15, Vcco=1.8V, DCI using 49.9 ohm resistors
33
NET  DDR2_A11             LOC="R29";   # Bank 15, Vcco=1.8V, DCI using 49.9 ohm resistors
34
NET  DDR2_A12             LOC="T31";   # Bank 15, Vcco=1.8V, DCI using 49.9 ohm resistors
35
NET  DDR2_A13             LOC="H29";   # Bank 15, Vcco=1.8V, DCI using 49.9 ohm resistors
36
NET  DDR2_BA0             LOC="G31";   # Bank 15, Vcco=1.8V, DCI using 49.9 ohm resistors
37
NET  DDR2_BA1             LOC="J30";   # Bank 15, Vcco=1.8V, DCI using 49.9 ohm resistors
38
NET  DDR2_BA2             LOC="R31";   # Bank 15, Vcco=1.8V, DCI using 49.9 ohm resistors
39
NET  DDR2_CAS_B           LOC="E31";   # Bank 15, Vcco=1.8V, DCI using 49.9 ohm resistors
40
NET  DDR2_CKE0            LOC="T28";   # Bank 15, Vcco=1.8V, DCI using 49.9 ohm resistors
41
NET  DDR2_CKE1            LOC="U30";   # Bank 15, Vcco=1.8V, DCI using 49.9 ohm resistors
42
NET  DDR2_CLK0_N          LOC="AJ29";  # Bank 21, Vcco=1.8V, DCI using 49.9 ohm resistors
43
NET  DDR2_CLK0_P          LOC="AK29";  # Bank 21, Vcco=1.8V, DCI using 49.9 ohm resistors
44
NET  DDR2_CLK1_N          LOC="F28";   # Bank 19, Vcco=1.8V, DCI using 49.9 ohm resistors
45
NET  DDR2_CLK1_P          LOC="E28";   # Bank 19, Vcco=1.8V, DCI using 49.9 ohm resistors
46
NET  DDR2_CS0_B           LOC="L29";   # Bank 15, Vcco=1.8V, DCI using 49.9 ohm resistors
47
NET  DDR2_CS1_B           LOC="J29";   # Bank 15, Vcco=1.8V, DCI using 49.9 ohm resistors
48
NET  DDR2_D0              LOC="AF30";  # Bank 17, Vcco=1.8V, DCI using 49.9 ohm resistors
49
NET  DDR2_D1              LOC="AK31";  # Bank 17, Vcco=1.8V, DCI using 49.9 ohm resistors
50
NET  DDR2_D2              LOC="AF31";  # Bank 17, Vcco=1.8V, DCI using 49.9 ohm resistors
51
NET  DDR2_D3              LOC="AD30";  # Bank 17, Vcco=1.8V, DCI using 49.9 ohm resistors
52
NET  DDR2_D4              LOC="AJ30";  # Bank 17, Vcco=1.8V, DCI using 49.9 ohm resistors
53
NET  DDR2_D5              LOC="AF29";  # Bank 17, Vcco=1.8V, DCI using 49.9 ohm resistors
54
NET  DDR2_D6              LOC="AD29";  # Bank 17, Vcco=1.8V, DCI using 49.9 ohm resistors
55
NET  DDR2_D7              LOC="AE29";  # Bank 17, Vcco=1.8V, DCI using 49.9 ohm resistors
56
NET  DDR2_D8              LOC="AH27";  # Bank 21, Vcco=1.8V, DCI using 49.9 ohm resistors
57
NET  DDR2_D9              LOC="AF28";  # Bank 21, Vcco=1.8V, DCI using 49.9 ohm resistors
58
NET  DDR2_D10             LOC="AH28";  # Bank 21, Vcco=1.8V, DCI using 49.9 ohm resistors
59
NET  DDR2_D11             LOC="AA28";  # Bank 21, Vcco=1.8V, DCI using 49.9 ohm resistors
60
NET  DDR2_D12             LOC="AG25";  # Bank 21, Vcco=1.8V, DCI using 49.9 ohm resistors
61
NET  DDR2_D13             LOC="AJ26";  # Bank 21, Vcco=1.8V, DCI using 49.9 ohm resistors
62
NET  DDR2_D14             LOC="AG28";  # Bank 21, Vcco=1.8V, DCI using 49.9 ohm resistors
63
NET  DDR2_D15             LOC="AB28";  # Bank 21, Vcco=1.8V, DCI using 49.9 ohm resistors
64
NET  DDR2_D16             LOC="AC28";  # Bank 21, Vcco=1.8V, DCI using 49.9 ohm resistors
65
NET  DDR2_D17             LOC="AB25";  # Bank 21, Vcco=1.8V, DCI using 49.9 ohm resistors
66
NET  DDR2_D18             LOC="AC27";  # Bank 21, Vcco=1.8V, DCI using 49.9 ohm resistors
67
NET  DDR2_D19             LOC="AA26";  # Bank 21, Vcco=1.8V, DCI using 49.9 ohm resistors
68
NET  DDR2_D20             LOC="AB26";  # Bank 21, Vcco=1.8V, DCI using 49.9 ohm resistors
69
NET  DDR2_D21             LOC="AA24";  # Bank 21, Vcco=1.8V, DCI using 49.9 ohm resistors
70
NET  DDR2_D22             LOC="AB27";  # Bank 21, Vcco=1.8V, DCI using 49.9 ohm resistors
71
NET  DDR2_D23             LOC="AA25";  # Bank 21, Vcco=1.8V, DCI using 49.9 ohm resistors
72
NET  DDR2_D24             LOC="AC29";  # Bank 17, Vcco=1.8V, DCI using 49.9 ohm resistors
73
NET  DDR2_D25             LOC="AB30";  # Bank 17, Vcco=1.8V, DCI using 49.9 ohm resistors
74
NET  DDR2_D26             LOC="W31";   # Bank 17, Vcco=1.8V, DCI using 49.9 ohm resistors
75
NET  DDR2_D27             LOC="V30";   # Bank 17, Vcco=1.8V, DCI using 49.9 ohm resistors
76
NET  DDR2_D28             LOC="AC30";  # Bank 17, Vcco=1.8V, DCI using 49.9 ohm resistors
77
NET  DDR2_D29             LOC="W29";   # Bank 17, Vcco=1.8V, DCI using 49.9 ohm resistors
78
NET  DDR2_D30             LOC="V27";   # Bank 17, Vcco=1.8V, DCI using 49.9 ohm resistors
79
NET  DDR2_D31             LOC="W27";   # Bank 17, Vcco=1.8V, DCI using 49.9 ohm resistors
80
NET  DDR2_D32             LOC="V29";   # Bank 17, Vcco=1.8V, DCI using 49.9 ohm resistors
81
NET  DDR2_D33             LOC="Y27";   # Bank 17, Vcco=1.8V, DCI using 49.9 ohm resistors
82
NET  DDR2_D34             LOC="Y26";   # Bank 17, Vcco=1.8V, DCI using 49.9 ohm resistors
83
NET  DDR2_D35             LOC="W24";   # Bank 17, Vcco=1.8V, DCI using 49.9 ohm resistors
84
NET  DDR2_D36             LOC="V28";   # Bank 17, Vcco=1.8V, DCI using 49.9 ohm resistors
85
NET  DDR2_D37             LOC="W25";   # Bank 17, Vcco=1.8V, DCI using 49.9 ohm resistors
86
NET  DDR2_D38             LOC="W26";   # Bank 17, Vcco=1.8V, DCI using 49.9 ohm resistors
87
NET  DDR2_D39             LOC="V24";   # Bank 17, Vcco=1.8V, DCI using 49.9 ohm resistors
88
NET  DDR2_D40             LOC="R24";   # Bank 19, Vcco=1.8V, DCI using 49.9 ohm resistors
89
NET  DDR2_D41             LOC="P25";   # Bank 19, Vcco=1.8V, DCI using 49.9 ohm resistors
90
NET  DDR2_D42             LOC="N24";   # Bank 19, Vcco=1.8V, DCI using 49.9 ohm resistors
91
NET  DDR2_D43             LOC="P26";   # Bank 19, Vcco=1.8V, DCI using 49.9 ohm resistors
92
NET  DDR2_D44             LOC="T24";   # Bank 19, Vcco=1.8V, DCI using 49.9 ohm resistors
93
NET  DDR2_D45             LOC="N25";   # Bank 19, Vcco=1.8V, DCI using 49.9 ohm resistors
94
NET  DDR2_D46             LOC="P27";   # Bank 19, Vcco=1.8V, DCI using 49.9 ohm resistors
95
NET  DDR2_D47             LOC="N28";   # Bank 19, Vcco=1.8V, DCI using 49.9 ohm resistors
96
NET  DDR2_D48             LOC="M28";   # Bank 19, Vcco=1.8V, DCI using 49.9 ohm resistors
97
NET  DDR2_D49             LOC="L28";   # Bank 19, Vcco=1.8V, DCI using 49.9 ohm resistors
98
NET  DDR2_D50             LOC="F25";   # Bank 19, Vcco=1.8V, DCI using 49.9 ohm resistors
99
NET  DDR2_D51             LOC="H25";   # Bank 19, Vcco=1.8V, DCI using 49.9 ohm resistors
100
NET  DDR2_D52             LOC="K27";   # Bank 19, Vcco=1.8V, DCI using 49.9 ohm resistors
101
NET  DDR2_D53             LOC="K28";   # Bank 19, Vcco=1.8V, DCI using 49.9 ohm resistors
102
NET  DDR2_D54             LOC="H24";   # Bank 19, Vcco=1.8V, DCI using 49.9 ohm resistors
103
NET  DDR2_D55             LOC="G26";   # Bank 19, Vcco=1.8V, DCI using 49.9 ohm resistors
104
NET  DDR2_D56             LOC="G25";   # Bank 19, Vcco=1.8V, DCI using 49.9 ohm resistors
105
NET  DDR2_D57             LOC="M26";   # Bank 19, Vcco=1.8V, DCI using 49.9 ohm resistors
106
NET  DDR2_D58             LOC="J24";   # Bank 19, Vcco=1.8V, DCI using 49.9 ohm resistors
107
NET  DDR2_D59             LOC="L26";   # Bank 19, Vcco=1.8V, DCI using 49.9 ohm resistors
108
NET  DDR2_D60             LOC="J27";   # Bank 19, Vcco=1.8V, DCI using 49.9 ohm resistors
109
NET  DDR2_D61             LOC="M25";   # Bank 19, Vcco=1.8V, DCI using 49.9 ohm resistors
110
NET  DDR2_D62             LOC="L25";   # Bank 19, Vcco=1.8V, DCI using 49.9 ohm resistors
111
NET  DDR2_D63             LOC="L24";   # Bank 19, Vcco=1.8V, DCI using 49.9 ohm resistors
112
NET  DDR2_DM0             LOC="AJ31";  # Bank 17, Vcco=1.8V, DCI using 49.9 ohm resistors
113
NET  DDR2_DM1             LOC="AE28";  # Bank 21, Vcco=1.8V, DCI using 49.9 ohm resistors
114
NET  DDR2_DM2             LOC="Y24";   # Bank 21, Vcco=1.8V, DCI using 49.9 ohm resistors
115
NET  DDR2_DM3             LOC="Y31";   # Bank 17, Vcco=1.8V, DCI using 49.9 ohm resistors
116
NET  DDR2_DM4             LOC="V25";   # Bank 17, Vcco=1.8V, DCI using 49.9 ohm resistors
117
NET  DDR2_DM5             LOC="P24";   # Bank 19, Vcco=1.8V, DCI using 49.9 ohm resistors
118
NET  DDR2_DM6             LOC="F26";   # Bank 19, Vcco=1.8V, DCI using 49.9 ohm resistors
119
NET  DDR2_DM7             LOC="J25";   # Bank 19, Vcco=1.8V, DCI using 49.9 ohm resistors
120
NET  DDR2_DQS0_N          LOC="AA30";  # Bank 17, Vcco=1.8V, DCI using 49.9 ohm resistors
121
NET  DDR2_DQS0_P          LOC="AA29";  # Bank 17, Vcco=1.8V, DCI using 49.9 ohm resistors
122
NET  DDR2_DQS1_N          LOC="AK27";  # Bank 21, Vcco=1.8V, DCI using 49.9 ohm resistors
123
NET  DDR2_DQS1_P          LOC="AK28";  # Bank 21, Vcco=1.8V, DCI using 49.9 ohm resistors
124
NET  DDR2_DQS2_N          LOC="AJ27";  # Bank 21, Vcco=1.8V, DCI using 49.9 ohm resistors
125
NET  DDR2_DQS2_P          LOC="AK26";  # Bank 21, Vcco=1.8V, DCI using 49.9 ohm resistors
126
NET  DDR2_DQS3_N          LOC="AA31";  # Bank 17, Vcco=1.8V, DCI using 49.9 ohm resistors
127
NET  DDR2_DQS3_P          LOC="AB31";  # Bank 17, Vcco=1.8V, DCI using 49.9 ohm resistors
128
NET  DDR2_DQS4_N          LOC="Y29";   # Bank 17, Vcco=1.8V, DCI using 49.9 ohm resistors
129
NET  DDR2_DQS4_P          LOC="Y28";   # Bank 17, Vcco=1.8V, DCI using 49.9 ohm resistors
130
NET  DDR2_DQS5_N          LOC="E27";   # Bank 19, Vcco=1.8V, DCI using 49.9 ohm resistors
131
NET  DDR2_DQS5_P          LOC="E26";   # Bank 19, Vcco=1.8V, DCI using 49.9 ohm resistors
132
NET  DDR2_DQS6_N          LOC="G28";   # Bank 19, Vcco=1.8V, DCI using 49.9 ohm resistors
133
NET  DDR2_DQS6_P          LOC="H28";   # Bank 19, Vcco=1.8V, DCI using 49.9 ohm resistors
134
NET  DDR2_DQS7_N          LOC="H27";   # Bank 19, Vcco=1.8V, DCI using 49.9 ohm resistors
135
NET  DDR2_DQS7_P          LOC="G27";   # Bank 19, Vcco=1.8V, DCI using 49.9 ohm resistors
136
NET  DDR2_ODT0            LOC="F31";   # Bank 15, Vcco=1.8V, DCI using 49.9 ohm resistors
137
NET  DDR2_ODT1            LOC="F30";   # Bank 15, Vcco=1.8V, DCI using 49.9 ohm resistors
138
NET  DDR2_RAS_B           LOC="H30";   # Bank 15, Vcco=1.8V, DCI using 49.9 ohm resistors
139
NET  DDR2_SCL             LOC="E29";   # Bank 15, Vcco=1.8V, DCI using 49.9 ohm resistors
140
NET  DDR2_SDA             LOC="F29";   # Bank 15, Vcco=1.8V, DCI using 49.9 ohm resistors
141
NET  DDR2_WE_B            LOC="K29";   # Bank 15, Vcco=1.8V, DCI using 49.9 ohm resistors
142
NET  DVI_D0               LOC="AB8";   # Bank 22, Vcco=3.3V, DCI using 49.9 ohm resistors
143
NET  DVI_D1               LOC="AC8";   # Bank 22, Vcco=3.3V, DCI using 49.9 ohm resistors
144
NET  DVI_D2               LOC="AN12";  # Bank 22, Vcco=3.3V, DCI using 49.9 ohm resistors
145
NET  DVI_D3               LOC="AP12";  # Bank 22, Vcco=3.3V, DCI using 49.9 ohm resistors
146
NET  DVI_D4               LOC="AA9";   # Bank 22, Vcco=3.3V, DCI using 49.9 ohm resistors
147
NET  DVI_D5               LOC="AA8";   # Bank 22, Vcco=3.3V, DCI using 49.9 ohm resistors
148
NET  DVI_D6               LOC="AM13";  # Bank 22, Vcco=3.3V, DCI using 49.9 ohm resistors
149
NET  DVI_D7               LOC="AN13";  # Bank 22, Vcco=3.3V, DCI using 49.9 ohm resistors
150
NET  DVI_D8               LOC="AA10";  # Bank 22, Vcco=3.3V, DCI using 49.9 ohm resistors
151
NET  DVI_D9               LOC="AB10";  # Bank 22, Vcco=3.3V, DCI using 49.9 ohm resistors
152
NET  DVI_D10              LOC="AP14";  # Bank 22, Vcco=3.3V, DCI using 49.9 ohm resistors
153
NET  DVI_D11              LOC="AN14";  # Bank 22, Vcco=3.3V, DCI using 49.9 ohm resistors
154
NET  DVI_DE               LOC="AE8";   # Bank 22, Vcco=3.3V, DCI using 49.9 ohm resistors
155
NET  DVI_GPIO1            LOC="N30";   # Bank 15, Vcco=1.8V, DCI using 49.9 ohm resistors
156
NET  DVI_H                LOC="AM12";  # Bank 22, Vcco=3.3V, DCI using 49.9 ohm resistors
157
NET  DVI_RESET_B          LOC="AK6";   # Bank 18, Vcco=3.3V, No DCI
158
NET  DVI_V                LOC="AM11";  # Bank 22, Vcco=3.3V, DCI using 49.9 ohm resistors
159
NET  DVI_XCLK_N           LOC="AL10";  # Bank 22, Vcco=3.3V, DCI using 49.9 ohm resistors
160
NET  DVI_XCLK_P           LOC="AL11";  # Bank 22, Vcco=3.3V, DCI using 49.9 ohm resistors
161
NET  FAN_ALERT_B          LOC="T30";   # Bank 15, Vcco=1.8V, DCI using 49.9 ohm resistors
162
NET  FLASH_ADV_B          LOC="F13";   # Bank 20, Vcco=3.3V, DCI using 49.9 ohm resistors
163
NET  FLASH_AUDIO_RESET_B  LOC="AG17";  # Bank 4, Vcco=3.3V, No DCI
164
NET  FLASH_CE_B           LOC="AE14";  # Bank 2, Vcco=3.3V
165
NET  FLASH_CLK            LOC="N9";    # Bank 20, Vcco=3.3V, DCI using 49.9 ohm resistors
166
NET  FLASH_OE_B           LOC="AF14";  # Bank 2, Vcco=3.3V
167
NET  FLASH_WAIT           LOC="G13";   # Bank 20, Vcco=3.3V, DCI using 49.9 ohm resistors
168
NET  FPGA_AVDD            LOC="T18";   # Bank 0, Vcco=3.3V
169
NET  FPGA_CCLK-R          LOC="N15";   # Bank 0, Vcco=3.3V
170
NET  FPGA_CPU_RESET_B     LOC="E9";    # Bank 20, Vcco=3.3V, DCI using 49.9 ohm resistors
171
NET  FPGA_CS_B            LOC="N22";   # Bank 0, Vcco=3.3V
172
NET  FPGA_CS0_B           LOC="AF21";  # Bank 2, Vcco=3.3V
173
NET  FPGA_DIFF_CLK_OUT_N  LOC="J21";   # Bank 3, Vcco=2.5V, No DCI
174
NET  FPGA_DIFF_CLK_OUT_P  LOC="J20";   # Bank 3, Vcco=2.5V, No DCI
175
NET  FPGA_DIN             LOC="P15";   # Bank 0, Vcco=3.3V
176
NET  FPGA_DONE            LOC="M15";   # Bank 0, Vcco=3.3V
177
NET  FPGA_DOUT_BUSY       LOC="AD15";  # Bank 0, Vcco=3.3V
178
NET  FPGA_DX_N            LOC="W17";   # Bank 0, Vcco=3.3V
179
NET  FPGA_DX_P            LOC="W18";   # Bank 0, Vcco=3.3V
180
NET  FPGA_EXP_TCK         LOC="AB15";  # Bank 0, Vcco=3.3V
181
NET  FPGA_EXP_TMS         LOC="AC14";  # Bank 0, Vcco=3.3V
182
NET  FPGA_HSWAPEN         LOC="M23";   # Bank 0, Vcco=3.3V
183
NET  FPGA_INIT_B          LOC="N14";   # Bank 0, Vcco=3.3V
184
NET  FPGA_M0              LOC="AD21";  # Bank 0, Vcco=3.3V
185
NET  FPGA_M1              LOC="AC22";  # Bank 0, Vcco=3.3V
186
NET  FPGA_M2              LOC="AD22";  # Bank 0, Vcco=3.3V
187
NET  FPGA_PROG_B          LOC="M22";   # Bank 0, Vcco=3.3V
188
NET  FPGA_RDWR_B          LOC="N23";   # Bank 0, Vcco=3.3V
189
NET  FPGA_ROTARY_INCA     LOC="AH30";  # Bank 17, Vcco=1.8V, DCI using 49.9 ohm resistors
190
NET  FPGA_ROTARY_INCB     LOC="AG30";  # Bank 17, Vcco=1.8V, DCI using 49.9 ohm resistors
191
NET  FPGA_ROTARY_PUSH     LOC="AH29";  # Bank 17, Vcco=1.8V, DCI using 49.9 ohm resistors
192
NET  FPGA_SERIAL1_RX      LOC="AG15";  # Bank 4, Vcco=3.3V, No DCI
193
NET  FPGA_SERIAL1_TX      LOC="AG20";  # Bank 4, Vcco=3.3V, No DCI
194
NET  FPGA_SERIAL2_RX      LOC="G10";   # Bank 20, Vcco=3.3V, DCI using 49.9 ohm resistors
195
NET  FPGA_SERIAL2_TX      LOC="F10";   # Bank 20, Vcco=3.3V, DCI using 49.9 ohm resistors
196
NET  FPGA_TDI             LOC="AC15";  # Bank 0, Vcco=3.3V
197
NET  FPGA_TDO             LOC="AD14";  # Bank 0, Vcco=3.3V
198
NET  FPGA_V_N             LOC="V17";   # Bank 0, Vcco=3.3V (SYSMON External Input: VN) J9-10
199
NET  FPGA_V_P             LOC="U18";   # Bank 0, Vcco=3.3V (SYSMON External Input: VP) J9-9
200
NET  FPGA_VBATT           LOC="L23";   # Bank 0, Vcco=3.3V
201
NET  FPGA_VREFP           LOC="V18";   # Bank 0, Vcco=3.3V
202
NET  FPGA_VRN_B11         LOC="N33";   # Bank 11, Vcco=2.5V or 3.3V user selectable by J20
203
NET  FPGA_VRN_B13         LOC="AG33";  # Bank 13, Vcco=2.5V or 3.3V user selectable by J20
204
NET  FPGA_VRN_B17         LOC="AD31";  # Bank 17, Vcco=1.8V, DCI using 49.9 ohm resistors
205
NET  FPGA_VRN_B19         LOC="N27";   # Bank 19, Vcco=1.8V, DCI using 49.9 ohm resistors
206
NET  FPGA_VRN_B20         LOC="L10";   # Bank 20, Vcco=3.3V, DCI using 49.9 ohm resistors
207
NET  FPGA_VRN_B21         LOC="AJ25";  # Bank 21, Vcco=1.8V, DCI using 49.9 ohm resistors
208
NET  FPGA_VRN_B22         LOC="AF8";   # Bank 22, Vcco=3.3V, DCI using 49.9 ohm resistors
209
NET  FPGA_VRP_B11         LOC="M33";   # Bank 11, Vcco=2.5V or 3.3V user selectable by J20
210
NET  FPGA_VRP_B13         LOC="AH33";  # Bank 13, Vcco=2.5V or 3.3V user selectable by J20
211
NET  FPGA_VRP_B17         LOC="AE31";  # Bank 17, Vcco=1.8V, DCI using 49.9 ohm resistors
212
NET  FPGA_VRP_B19         LOC="M27";   # Bank 19, Vcco=1.8V, DCI using 49.9 ohm resistors
213
NET  FPGA_VRP_B20         LOC="L11";   # Bank 20, Vcco=3.3V, DCI using 49.9 ohm resistors
214
NET  FPGA_VRP_B21         LOC="AH25";  # Bank 21, Vcco=1.8V, DCI using 49.9 ohm resistors
215
NET  FPGA_VRP_B22         LOC="AE9";   # Bank 22, Vcco=3.3V, DCI using 49.9 ohm resistors
216
NET  GPIO_DIP_SW1         LOC="U25";   # Bank 15, Vcco=1.8V, DCI using 49.9 ohm resistors
217
NET  GPIO_DIP_SW2         LOC="AG27";  # Bank 21, Vcco=1.8V, DCI using 49.9 ohm resistors
218
NET  GPIO_DIP_SW3         LOC="AF25";  # Bank 21, Vcco=1.8V, DCI using 49.9 ohm resistors
219
NET  GPIO_DIP_SW4         LOC="AF26";  # Bank 21, Vcco=1.8V, DCI using 49.9 ohm resistors
220
NET  GPIO_DIP_SW5         LOC="AE27";  # Bank 21, Vcco=1.8V, DCI using 49.9 ohm resistors
221
NET  GPIO_DIP_SW6         LOC="AE26";  # Bank 21, Vcco=1.8V, DCI using 49.9 ohm resistors
222
NET  GPIO_DIP_SW7         LOC="AC25";  # Bank 21, Vcco=1.8V, DCI using 49.9 ohm resistors
223
NET  GPIO_DIP_SW8         LOC="AC24";  # Bank 21, Vcco=1.8V, DCI using 49.9 ohm resistors
224
NET  GPIO_LED_0           LOC="H18";   # Bank 3, Vcco=2.5V, No DCI
225
NET  GPIO_LED_1           LOC="L18";   # Bank 3, Vcco=2.5V, No DCI
226
NET  GPIO_LED_2           LOC="G15";   # Bank 3, Vcco=2.5V, No DCI
227
NET  GPIO_LED_3           LOC="AD26";  # Bank 21, Vcco=1.8V, DCI using 49.9 ohm resistors
228
NET  GPIO_LED_4           LOC="G16";   # Bank 3, Vcco=2.5V, No DCI
229
NET  GPIO_LED_5           LOC="AD25";  # Bank 21, Vcco=1.8V, DCI using 49.9 ohm resistors
230
NET  GPIO_LED_6           LOC="AD24";  # Bank 21, Vcco=1.8V, DCI using 49.9 ohm resistors
231
NET  GPIO_LED_7           LOC="AE24";  # Bank 21, Vcco=1.8V, DCI using 49.9 ohm resistors
232
NET  GPIO_LED_C           LOC="E8";    # Bank 20, Vcco=3.3V, DCI using 49.9 ohm resistors
233
NET  GPIO_LED_E           LOC="AG23";  # Bank 2, Vcco=3.3V
234
NET  GPIO_LED_N           LOC="AF13";  # Bank 2, Vcco=3.3V
235
NET  GPIO_LED_S           LOC="AG12";  # Bank 2, Vcco=3.3V
236
NET  GPIO_LED_W           LOC="AF23";  # Bank 2, Vcco=3.3V
237
NET  GPIO_SW_C            LOC="AJ6";   # Bank 18, Vcco=3.3V, No DCI
238
NET  GPIO_SW_E            LOC="AK7";   # Bank 18, Vcco=3.3V, No DCI
239
NET  GPIO_SW_N            LOC="U8";    # Bank 18, Vcco=3.3V, No DCI
240
NET  GPIO_SW_S            LOC="V8";    # Bank 18, Vcco=3.3V, No DCI
241
NET  GPIO_SW_W            LOC="AJ7";   # Bank 18, Vcco=3.3V, No DCI
242
NET  HDR1_2               LOC="H33";   # Bank 11, Vcco=2.5V or 3.3V user selectable by J20
243
NET  HDR1_4               LOC="F34";   # Bank 11, Vcco=2.5V or 3.3V user selectable by J20
244
NET  HDR1_6               LOC="H34";   # Bank 11, Vcco=2.5V or 3.3V user selectable by J20
245
NET  HDR1_8               LOC="G33";   # Bank 11, Vcco=2.5V or 3.3V user selectable by J20
246
NET  HDR1_10              LOC="G32";   # Bank 11, Vcco=2.5V or 3.3V user selectable by J20
247
NET  HDR1_12              LOC="H32";   # Bank 11, Vcco=2.5V or 3.3V user selectable by J20
248
NET  HDR1_14              LOC="J32";   # Bank 11, Vcco=2.5V or 3.3V user selectable by J20
249
NET  HDR1_16              LOC="J34";   # Bank 11, Vcco=2.5V or 3.3V user selectable by J20
250
NET  HDR1_18              LOC ="L33";  # Bank 11, Vcco=2.5V or 3.3V user selectable by J20
251
NET  HDR1_20              LOC="M32";   # Bank 11, Vcco=2.5V or 3.3V user selectable by J20
252
NET  HDR1_22              LOC="P34";   # Bank 11, Vcco=2.5V or 3.3V user selectable by J20
253
NET  HDR1_24              LOC="N34";   # Bank 11, Vcco=2.5V or 3.3V user selectable by J20
254
NET  HDR1_26              LOC="AA34";  # Bank 13, Vcco=2.5V or 3.3V user selectable by J20 (SYSMON External Input: VAUXP[5]) J6-26
255
NET  HDR1_28              LOC="AD32";  # Bank 13, Vcco=2.5V or 3.3V user selectable by J20
256
NET  HDR1_30              LOC="Y34";   # Bank 13, Vcco=2.5V or 3.3V user selectable by J20 (SYSMON External Input: VAUXN[5]) J6-30
257
NET  HDR1_32              LOC="Y32";   # Bank 13, Vcco=2.5V or 3.3V user selectable by J20
258
NET  HDR1_34              LOC="W32";   # Bank 13, Vcco=2.5V or 3.3V user selectable by J20
259
NET  HDR1_36              LOC="AH34";  # Bank 13, Vcco=2.5V or 3.3V user selectable by J20
260
NET  HDR1_38              LOC="AE32";  # Bank 13, Vcco=2.5V or 3.3V user selectable by J20
261
NET  HDR1_40              LOC="AG32";  # Bank 13, Vcco=2.5V or 3.3V user selectable by J20
262
NET  HDR1_42              LOC="AH32";  # Bank 13, Vcco=2.5V or 3.3V user selectable by J20
263
NET  HDR1_44              LOC="AK34";  # Bank 13, Vcco=2.5V or 3.3V user selectable by J20
264
NET  HDR1_46              LOC="AK33";  # Bank 13, Vcco=2.5V or 3.3V user selectable by J20
265
NET  HDR1_48              LOC="AJ32";  # Bank 13, Vcco=2.5V or 3.3V user selectable by J20
266
NET  HDR1_50              LOC="AK32";  # Bank 13, Vcco=2.5V or 3.3V user selectable by J20
267
NET  HDR1_52              LOC="AL34";  # Bank 13, Vcco=2.5V or 3.3V user selectable by J20
268
NET  HDR1_54              LOC="AL33";  # Bank 13, Vcco=2.5V or 3.3V user selectable by J20
269
NET  HDR1_56              LOC="AM33";  # Bank 13, Vcco=2.5V or 3.3V user selectable by J20
270
NET  HDR1_58              LOC="AJ34";  # Bank 13, Vcco=2.5V or 3.3V user selectable by J20
271
NET  HDR1_60              LOC="AM32";  # Bank 13, Vcco=2.5V or 3.3V user selectable by J20
272
NET  HDR1_62              LOC="AN34";  # Bank 13, Vcco=2.5V or 3.3V user selectable by J20
273
NET  HDR1_64              LOC="AN33";  # Bank 13, Vcco=2.5V or 3.3V user selectable by J20
274
NET  HDR2_2_SM_8_N        LOC="K34";   # Bank 11, Vcco=2.5V or 3.3V user selectable by J20 (SYSMON External Input: VAUXN[15]) J4-2
275
NET  HDR2_4_SM_8_P        LOC="L34";   # Bank 11, Vcco=2.5V or 3.3V user selectable by J20 (SYSMON External Input: VAUXP[15]) J4-4
276
NET  HDR2_6_SM_7_N        LOC="K32";   # Bank 11, Vcco=2.5V or 3.3V user selectable by J20 (SYSMON External Input: VAUXN[14]) J4-6
277
NET  HDR2_8_SM_7_P        LOC="K33";   # Bank 11, Vcco=2.5V or 3.3V user selectable by J20 (SYSMON External Input: VAUXP[14]) J4-8
278
NET  HDR2_10_DIFF_0_N     LOC="N32";   # Bank 11, Vcco=2.5V or 3.3V user selectable by J20 (SYSMON External Input: VAUXN[13]) J4-10
279
NET  HDR2_12_DIFF_0_P     LOC="P32";   # Bank 11, Vcco=2.5V or 3.3V user selectable by J20 (SYSMON External Input: VAUXP[13]) J4-12
280
NET  HDR2_14_DIFF_1_N     LOC="R34";   # Bank 11, Vcco=2.5V or 3.3V user selectable by J20 (SYSMON External Input: VAUXN[12]) J4-14
281
NET  HDR2_16_DIFF_1_P     LOC="T33";   # Bank 11, Vcco=2.5V or 3.3V user selectable by J20 (SYSMON External Input: VAUXP[12]) J4-16
282
NET  HDR2_18_DIFF_2_N     LOC="R32";   # Bank 11, Vcco=2.5V or 3.3V user selectable by J20 (SYSMON External Input: VAUXN[11]) J4-18
283
NET  HDR2_20_DIFF_2_P     LOC="R33";   # Bank 11, Vcco=2.5V or 3.3V user selectable by J20 (SYSMON External Input: VAUXP[11]) J4-20
284
NET  HDR2_22_SM_10_N      LOC="T34";   # Bank 11, Vcco=2.5V or 3.3V user selectable by J20 (SYSMON External Input: VAUXN[10]) J4-22
285
NET  HDR2_24_SM_10_P      LOC="U33";   # Bank 11, Vcco=2.5V or 3.3V user selectable by J20 (SYSMON External Input: VAUXP[10]) J4-24
286
NET  HDR2_26_SM_11_N      LOC="U31";   # Bank 11, Vcco=2.5V or 3.3V user selectable by J20 (SYSMON External Input: VAUXN[9]) J4-26
287
NET  HDR2_28_SM_11_P      LOC="U32";   # Bank 11, Vcco=2.5V or 3.3V user selectable by J20 (SYSMON External Input: VAUXP[9]) J4-28
288
NET  HDR2_30_DIFF_3_N     LOC="V33";   # Bank 13, Vcco=2.5V or 3.3V user selectable by J20 (SYSMON External Input: VAUXN[8]) J4-30
289
NET  HDR2_32_DIFF_3_P     LOC="V32";   # Bank 13, Vcco=2.5V or 3.3V user selectable by J20 (SYSMON External Input: VAUXP[8]) J4-32
290
NET  HDR2_34_SM_15_N      LOC="V34";   # Bank 13, Vcco=2.5V or 3.3V user selectable by J20 (SYSMON External Input: VAUXN[7]) J4-34
291
NET  HDR2_36_SM_15_P      LOC="W34";   # Bank 13, Vcco=2.5V or 3.3V user selectable by J20 (SYSMON External Input: VAUXP[7]) J4-36
292
NET  HDR2_38_SM_6_N       LOC="AA33";  # Bank 13, Vcco=2.5V or 3.3V user selectable by J20 (SYSMON External Input: VAUXN[6]) J4-38
293
NET  HDR2_40_SM_6_P       LOC="Y33";   # Bank 13, Vcco=2.5V or 3.3V user selectable by J20 (SYSMON External Input: VAUXP[6]) J4-40
294
NET  HDR2_42_SM_14_N      LOC="AE34";  # Bank 13, Vcco=2.5V or 3.3V user selectable by J20 (SYSMON External Input: VAUXN[0]) J4-42
295
NET  HDR2_44_SM_14_P      LOC="AF34";  # Bank 13, Vcco=2.5V or 3.3V user selectable by J20 (SYSMON External Input: VAUXP[0]) J4-44
296
NET  HDR2_46_SM_12_N      LOC="AE33";  # Bank 13, Vcco=2.5V or 3.3V user selectable by J20 (SYSMON External Input: VAUXN[1]) J4-46
297
NET  HDR2_48_SM_12_P      LOC="AF33";  # Bank 13, Vcco=2.5V or 3.3V user selectable by J20 (SYSMON External Input: VAUXP[1]) J4-48
298
NET  HDR2_50_SM_5_N       LOC="AD34";  # Bank 13, Vcco=2.5V or 3.3V user selectable by J20 (SYSMON External Input: VAUXN[4]) J4-50
299
NET  HDR2_52_SM_5_P       LOC="AC34";  # Bank 13, Vcco=2.5V or 3.3V user selectable by J20 (SYSMON External Input: VAUXP[4]) J4-52
300
NET  HDR2_54_SM_13_N      LOC="AB32";  # Bank 13, Vcco=2.5V or 3.3V user selectable by J20 (SYSMON External Input: VAUXN[3]) J4-54
301
NET  HDR2_56_SM_13_P      LOC="AC32";  # Bank 13, Vcco=2.5V or 3.3V user selectable by J20 (SYSMON External Input: VAUXP[3]) J4-56
302
NET  HDR2_58_SM_4_N       LOC="AB33";  # Bank 13, Vcco=2.5V or 3.3V user selectable by J20 (SYSMON External Input: VAUXN[2]) J4-58
303
NET  HDR2_60_SM_4_P       LOC="AC33";  # Bank 13, Vcco=2.5V or 3.3V user selectable by J20 (SYSMON External Input: VAUXP[2]) J4-60
304
NET  HDR2_62_SM_9_N       LOC="AP32";  # Bank 13, Vcco=2.5V or 3.3V user selectable by J20
305
NET  HDR2_64_SM_9_P       LOC="AN32";  # Bank 13, Vcco=2.5V or 3.3V user selectable by J20
306
NET  IIC_SCL_MAIN         LOC="F9";    # Bank 20, Vcco=3.3V, DCI using 49.9 ohm resistors
307
NET  IIC_SCL_SFP          LOC="R26";   # Bank 15, Vcco=1.8V, DCI using 49.9 ohm resistors
308
NET  IIC_SCL_VIDEO        LOC="U27";   # Bank 15, Vcco=1.8V, DCI using 49.9 ohm resistors
309
NET  IIC_SDA_MAIN         LOC="F8";    # Bank 20, Vcco=3.3V, DCI using 49.9 ohm resistors
310
NET  IIC_SDA_SFP          LOC="U28";   # Bank 15, Vcco=1.8V, DCI using 49.9 ohm resistors
311
NET  IIC_SDA_VIDEO        LOC="T29";   # Bank 15, Vcco=1.8V, DCI using 49.9 ohm resistors
312
NET  KEYBOARD_CLK         LOC="T26";   # Bank 15, Vcco=1.8V, DCI using 49.9 ohm resistors
313
NET  KEYBOARD_DATA        LOC="T25";   # Bank 15, Vcco=1.8V, DCI using 49.9 ohm resistors
314
NET  LCD_FPGA_DB4         LOC="T9";    # Bank 12, Vcco=3.3V, DCI using 49.9 ohm resistors
315
NET  LCD_FPGA_DB5         LOC="G7";    # Bank 12, Vcco=3.3V, DCI using 49.9 ohm resistors
316
NET  LCD_FPGA_DB6         LOC="G6";    # Bank 12, Vcco=3.3V, DCI using 49.9 ohm resistors
317
NET  LCD_FPGA_DB7         LOC="T11";   # Bank 12, Vcco=3.3V, DCI using 49.9 ohm resistors
318
NET  LCD_FPGA_E           LOC="AC9";   # Bank 22, Vcco=3.3V, DCI using 49.9 ohm resistors
319
NET  LCD_FPGA_RS          LOC="J17";   # Bank 3, Vcco=2.5V, No DCI
320
NET  LCD_FPGA_RW          LOC="AC10";  # Bank 22, Vcco=3.3V, DCI using 49.9 ohm resistors
321
NET  LOOPBK_114_N         LOC="AG1";   # Bank 118, MGTRXN1_118, GTP_DUAL_X0Y1
322
NET  LOOPBK_114_N         LOC="AH2";   # Bank 118, MGTTXN1_118, GTP_DUAL_X0Y1
323
NET  LOOPBK_114_P         LOC="AH1";   # Bank 118, MGTRXP1_118, GTP_DUAL_X0Y1
324
NET  LOOPBK_114_P         LOC="AJ2";   # Bank 118, MGTTXP1_118, GTP_DUAL_X0Y1
325
NET  LOOPBK_116_N         LOC="R1";    # Bank 112, MGTRXN1_112, GTP_DUAL_X0Y3
326
NET  LOOPBK_116_N         LOC="T2";    # Bank 112, MGTTXN1_112, GTP_DUAL_X0Y3
327
NET  LOOPBK_116_P         LOC="T1";    # Bank 112, MGTRXP1_112, GTP_DUAL_X0Y3
328
NET  LOOPBK_116_P         LOC="U2";    # Bank 112, MGTTXP1_112, GTP_DUAL_X0Y3
329
NET  MOUSE_CLK            LOC="R27";   # Bank 15, Vcco=1.8V, DCI using 49.9 ohm resistors
330
NET  MOUSE_DATA           LOC="U26";   # Bank 15, Vcco=1.8V, DCI using 49.9 ohm resistors
331
NET  PC4_HALT_B           LOC="W9";    # Bank 18, Vcco=3.3V, No DCI
332
NET  PCIE_CLK_QO_N        LOC="AF3";   # Bank 118, MGTREFCLKN_118, GTP_DUAL_X0Y1
333
NET  PCIE_CLK_QO_P        LOC="AF4";   # Bank 118, MGTREFCLKP_118, GTP_DUAL_X0Y1
334
NET  PCIE_PRSNT_B_FPGA    LOC="AF24";  # Bank 21, Vcco=1.8V, DCI using 49.9 ohm resistors
335
NET  PCIE_RX_N            LOC="AF1";   # Bank 118, MGTRXN0_118, GTP_DUAL_X0Y1
336
NET  PCIE_RX_P            LOC="AE1";   # Bank 118, MGTRXP0_118, GTP_DUAL_X0Y1
337
NET  PCIE_TX_N            LOC="AE2";   # Bank 118, MGTTXN0_118, GTP_DUAL_X0Y1
338
NET  PCIE_TX_P            LOC="AD2";   # Bank 118, MGTTXP0_118, GTP_DUAL_X0Y1
339
NET  PHY_COL              LOC="B32";   # Bank 11, Vcco=2.5V or 3.3V user selectable by J20
340
NET  PHY_CRS              LOC="E34";   # Bank 11, Vcco=2.5V or 3.3V user selectable by J20
341
NET  PHY_INT              LOC="H20";   # Bank 3, Vcco=2.5V, No DCI
342
NET  PHY_MDC              LOC="H19";   # Bank 3, Vcco=2.5V, No DCI
343
NET  PHY_MDIO             LOC="H13";   # Bank 3, Vcco=2.5V, No DCI
344
NET  PHY_RESET            LOC="J14";   # Bank 3, Vcco=2.5V, No DCI
345
NET  PHY_RXCLK            LOC="H17";   # Bank 3, Vcco=2.5V, No DCI
346
NET  PHY_RXCTL_RXDV       LOC="E32";   # Bank 11, Vcco=2.5V or 3.3V user selectable by J20
347
NET  PHY_RXD0             LOC="A33";   # Bank 11, Vcco=2.5V or 3.3V user selectable by J20
348
NET  PHY_RXD1             LOC="B33";   # Bank 11, Vcco=2.5V or 3.3V user selectable by J20
349
NET  PHY_RXD2             LOC="C33";   # Bank 11, Vcco=2.5V or 3.3V user selectable by J20
350
NET  PHY_RXD3             LOC="C32";   # Bank 11, Vcco=2.5V or 3.3V user selectable by J20
351
NET  PHY_RXD4             LOC="D32";   # Bank 11, Vcco=2.5V or 3.3V user selectable by J20
352
NET  PHY_RXD5             LOC="C34";   # Bank 11, Vcco=2.5V or 3.3V user selectable by J20
353
NET  PHY_RXD6             LOC="D34";   # Bank 11, Vcco=2.5V or 3.3V user selectable by J20
354
NET  PHY_RXD7             LOC="F33";   # Bank 11, Vcco=2.5V or 3.3V user selectable by J20
355
NET  PHY_RXER             LOC="E33";   # Bank 11, Vcco=2.5V or 3.3V user selectable by J20
356
NET  PHY_TXC_GTXCLK       LOC="J16";   # Bank 3, Vcco=2.5V, No DCI
357
NET  PHY_TXCLK            LOC="K17";   # Bank 3, Vcco=2.5V, No DCI
358
NET  PHY_TXCTL_TXEN       LOC="AJ10";  # Bank 22, Vcco=3.3V, DCI using 49.9 ohm resistors
359
NET  PHY_TXD0             LOC="AF11";  # Bank 22, Vcco=3.3V, DCI using 49.9 ohm resistors
360
NET  PHY_TXD1             LOC="AE11";  # Bank 22, Vcco=3.3V, DCI using 49.9 ohm resistors
361
NET  PHY_TXD2             LOC="AH9";   # Bank 22, Vcco=3.3V, DCI using 49.9 ohm resistors
362
NET  PHY_TXD3             LOC="AH10";  # Bank 22, Vcco=3.3V, DCI using 49.9 ohm resistors
363
NET  PHY_TXD4             LOC="AG8";   # Bank 22, Vcco=3.3V, DCI using 49.9 ohm resistors
364
NET  PHY_TXD5             LOC="AH8";   # Bank 22, Vcco=3.3V, DCI using 49.9 ohm resistors
365
NET  PHY_TXD6             LOC="AG10";  # Bank 22, Vcco=3.3V, DCI using 49.9 ohm resistors
366
NET  PHY_TXD7             LOC="AG11";  # Bank 22, Vcco=3.3V, DCI using 49.9 ohm resistors
367
NET  PHY_TXER             LOC="AJ9";   # Bank 22, Vcco=3.3V, DCI using 49.9 ohm resistors
368
NET  PIEZO_SPEAKER        LOC="G30";   # Bank 15, Vcco=1.8V, DCI using 49.9 ohm resistors
369
NET  RESERVED1            LOC="AB23";  # Bank 0, Vcco=3.3V
370
NET  RESERVED2            LOC="AC23";  # Bank 0, Vcco=3.3V
371
NET  RREF                 LOC="V4";    # Bank 112, MGTRREF_112, GTP_DUAL_X0Y3
372
NET  SATA1_RX_N           LOC="Y1";    # Bank 114, MGTRXN0_114, GTP_DUAL_X0Y2
373
NET  SATA1_RX_P           LOC="W1";    # Bank 114, MGTRXP0_114, GTP_DUAL_X0Y2
374
NET  SATA1_TX_N           LOC="W2";    # Bank 114, MGTTXN0_114, GTP_DUAL_X0Y2
375
NET  SATA1_TX_P           LOC="V2";    # Bank 114, MGTTXP0_114, GTP_DUAL_X0Y2
376
NET  SATA2_RX_N           LOC="AA1";   # Bank 114, MGTRXN1_114, GTP_DUAL_X0Y2
377
NET  SATA2_RX_P           LOC="AB1";   # Bank 114, MGTRXP1_114, GTP_DUAL_X0Y2
378
NET  SATA2_TX_N           LOC="AB2";   # Bank 114, MGTTXN1_114, GTP_DUAL_X0Y2
379
NET  SATA2_TX_P           LOC="AC2";   # Bank 114, MGTTXP1_114, GTP_DUAL_X0Y2
380
NET  SATACLK_QO_N         LOC="Y3";    # Bank 114, MGTREFCLKN_114, GTP_DUAL_X0Y2
381
NET  SATACLK_QO_P         LOC="Y4";    # Bank 114, MGTREFCLKP_114, GTP_DUAL_X0Y2
382
NET  SFP_RX_N             LOC="H1";    # Bank 116, MGTRXN0_116, GTP_DUAL_X0Y4
383
NET  SFP_RX_P             LOC="G1";    # Bank 116, MGTRXP0_116, GTP_DUAL_X0Y4
384
NET  SFP_TX_DISABLE_FPGA  LOC="K24";   # Bank 19, Vcco=1.8V, DCI using 49.9 ohm resistors
385
NET  SFP_TX_N             LOC="G2";    # Bank 116, MGTTXN0_116, GTP_DUAL_X0Y4
386
NET  SFP_TX_P             LOC="F2";    # Bank 116, MGTTXP0_116, GTP_DUAL_X0Y4
387
NET  SGMII_RX_N           LOC="P1";    # Bank 112, MGTRXN0_112, GTP_DUAL_X0Y3
388
NET  SGMII_RX_P           LOC="N1";    # Bank 112, MGTRXP0_112, GTP_DUAL_X0Y3
389
NET  SGMII_TX_N           LOC="N2";    # Bank 112, MGTTXN0_112, GTP_DUAL_X0Y3
390
NET  SGMII_TX_P           LOC="M2";    # Bank 112, MGTTXP0_112, GTP_DUAL_X0Y3
391
NET  SGMIICLK_QO_N        LOC="P3";    # Bank 112, MGTREFCLKN_112, GTP_DUAL_X0Y3
392
NET  SGMIICLK_QO_P        LOC="P4";    # Bank 112, MGTREFCLKP_112, GTP_DUAL_X0Y3
393
NET  SMA_DIFF_CLK_IN_N    LOC="H15";   # Bank 3, Vcco=2.5V, No DCI
394
NET  SMA_DIFF_CLK_IN_P    LOC="H14";   # Bank 3, Vcco=2.5V, No DCI
395
NET  SMA_RX_N             LOC="J1";    # Bank 116, MGTRXN1_116, GTP_DUAL_X0Y4
396
NET  SMA_RX_P             LOC="K1";    # Bank 116, MGTRXP1_116, GTP_DUAL_X0Y4
397
NET  SMA_TX_N             LOC="K2";    # Bank 116, MGTTXN1_116, GTP_DUAL_X0Y4
398
NET  SMA_TX_P             LOC="L2";    # Bank 116, MGTTXP1_116, GTP_DUAL_X0Y4
399
NET  SPI_CE_B             LOC="V9";    # Bank 18, Vcco=3.3V, No DCI
400
NET  SRAM_ADV_LD_B        LOC="H8";    # Bank 20, Vcco=3.3V, DCI using 49.9 ohm resistors
401
NET  SRAM_BW0             LOC="D10";   # Bank 20, Vcco=3.3V, DCI using 49.9 ohm resistors
402
NET  SRAM_BW1             LOC="D11";   # Bank 20, Vcco=3.3V, DCI using 49.9 ohm resistors
403
NET  SRAM_BW2             LOC="J11";   # Bank 20, Vcco=3.3V, DCI using 49.9 ohm resistors
404
NET  SRAM_BW3             LOC="K11";   # Bank 20, Vcco=3.3V, DCI using 49.9 ohm resistors
405
NET  SRAM_CLK             LOC="AG21";  # Bank 4, Vcco=3.3V, No DCI
406
NET  SRAM_CLK             LOC="G8";    # Bank 20, Vcco=3.3V, DCI using 49.9 ohm resistors
407
NET  SRAM_CS_B            LOC="J10";   # Bank 20, Vcco=3.3V, DCI using 49.9 ohm resistors
408
NET  SRAM_D16             LOC="N10";   # Bank 20, Vcco=3.3V, DCI using 49.9 ohm resistors
409
NET  SRAM_D17             LOC="E13";   # Bank 20, Vcco=3.3V, DCI using 49.9 ohm resistors
410
NET  SRAM_D18             LOC="E12";   # Bank 20, Vcco=3.3V, DCI using 49.9 ohm resistors
411
NET  SRAM_D19             LOC="L9";    # Bank 20, Vcco=3.3V, DCI using 49.9 ohm resistors
412
NET  SRAM_D20             LOC="M10";   # Bank 20, Vcco=3.3V, DCI using 49.9 ohm resistors
413
NET  SRAM_D21             LOC="E11";   # Bank 20, Vcco=3.3V, DCI using 49.9 ohm resistors
414
NET  SRAM_D22             LOC="F11";   # Bank 20, Vcco=3.3V, DCI using 49.9 ohm resistors
415
NET  SRAM_D23             LOC="L8";    # Bank 20, Vcco=3.3V, DCI using 49.9 ohm resistors
416
NET  SRAM_D24             LOC="M8";    # Bank 20, Vcco=3.3V, DCI using 49.9 ohm resistors
417
NET  SRAM_D25             LOC="G12";   # Bank 20, Vcco=3.3V, DCI using 49.9 ohm resistors
418
NET  SRAM_D26             LOC="G11";   # Bank 20, Vcco=3.3V, DCI using 49.9 ohm resistors
419
NET  SRAM_D27             LOC="C13";   # Bank 20, Vcco=3.3V, DCI using 49.9 ohm resistors
420
NET  SRAM_D28             LOC="B13";   # Bank 20, Vcco=3.3V, DCI using 49.9 ohm resistors
421
NET  SRAM_D29             LOC="K9";    # Bank 20, Vcco=3.3V, DCI using 49.9 ohm resistors
422
NET  SRAM_D30             LOC="K8";    # Bank 20, Vcco=3.3V, DCI using 49.9 ohm resistors
423
NET  SRAM_D31             LOC="J9";    # Bank 20, Vcco=3.3V, DCI using 49.9 ohm resistors
424
NET  SRAM_DQP0            LOC="D12";   # Bank 20, Vcco=3.3V, DCI using 49.9 ohm resistors
425
NET  SRAM_DQP1            LOC="C12";   # Bank 20, Vcco=3.3V, DCI using 49.9 ohm resistors
426
NET  SRAM_DQP2            LOC="H10";   # Bank 20, Vcco=3.3V, DCI using 49.9 ohm resistors
427
NET  SRAM_DQP3            LOC="H9";    # Bank 20, Vcco=3.3V, DCI using 49.9 ohm resistors
428
NET  SRAM_FLASH_A0        LOC="K12";   # Bank 1, Vcco=3.3V
429
NET  SRAM_FLASH_A1        LOC="K13";   # Bank 1, Vcco=3.3V
430
NET  SRAM_FLASH_A2        LOC="H23";   # Bank 1, Vcco=3.3V
431
NET  SRAM_FLASH_A3        LOC="G23";   # Bank 1, Vcco=3.3V
432
NET  SRAM_FLASH_A4        LOC="H12";   # Bank 1, Vcco=3.3V
433
NET  SRAM_FLASH_A5        LOC="J12";   # Bank 1, Vcco=3.3V
434
NET  SRAM_FLASH_A6        LOC="K22";   # Bank 1, Vcco=3.3V
435
NET  SRAM_FLASH_A7        LOC="K23";   # Bank 1, Vcco=3.3V
436
NET  SRAM_FLASH_A8        LOC="K14";   # Bank 1, Vcco=3.3V
437
NET  SRAM_FLASH_A9        LOC="L14";   # Bank 1, Vcco=3.3V
438
NET  SRAM_FLASH_A10       LOC="H22";   # Bank 1, Vcco=3.3V
439
NET  SRAM_FLASH_A11       LOC="G22";   # Bank 1, Vcco=3.3V
440
NET  SRAM_FLASH_A12       LOC="J15";   # Bank 1, Vcco=3.3V
441
NET  SRAM_FLASH_A13       LOC="K16";   # Bank 1, Vcco=3.3V
442
NET  SRAM_FLASH_A14       LOC="K21";   # Bank 1, Vcco=3.3V
443
NET  SRAM_FLASH_A15       LOC="J22";   # Bank 1, Vcco=3.3V
444
NET  SRAM_FLASH_A16       LOC="L16";   # Bank 1, Vcco=3.3V
445
NET  SRAM_FLASH_A17       LOC="L15";   # Bank 1, Vcco=3.3V
446
NET  SRAM_FLASH_A18       LOC="L20";   # Bank 1, Vcco=3.3V
447
NET  SRAM_FLASH_A19       LOC="L21";   # Bank 1, Vcco=3.3V
448
NET  SRAM_FLASH_A20       LOC="AE23";  # Bank 2, Vcco=3.3V
449
NET  SRAM_FLASH_A21       LOC="AE22";  # Bank 2, Vcco=3.3V
450
NET  SRAM_FLASH_D0        LOC="AD19";  # Bank 2, Vcco=3.3V
451
NET  SRAM_FLASH_D1        LOC="AE19";  # Bank 2, Vcco=3.3V
452
NET  SRAM_FLASH_D2        LOC="AE17";  # Bank 2, Vcco=3.3V
453
NET  SRAM_FLASH_D3        LOC="AF16";  # Bank 2, Vcco=3.3V
454
NET  SRAM_FLASH_D4        LOC="AD20";  # Bank 2, Vcco=3.3V
455
NET  SRAM_FLASH_D5        LOC="AE21";  # Bank 2, Vcco=3.3V
456
NET  SRAM_FLASH_D6        LOC="AE16";  # Bank 2, Vcco=3.3V
457
NET  SRAM_FLASH_D7        LOC="AF15";  # Bank 2, Vcco=3.3V
458
NET  SRAM_FLASH_D8        LOC="AH13";  # Bank 4, Vcco=3.3V, No DCI
459
NET  SRAM_FLASH_D9        LOC="AH14";  # Bank 4, Vcco=3.3V, No DCI
460
NET  SRAM_FLASH_D10       LOC="AH19";  # Bank 4, Vcco=3.3V, No DCI
461
NET  SRAM_FLASH_D11       LOC="AH20";  # Bank 4, Vcco=3.3V, No DCI
462
NET  SRAM_FLASH_D12       LOC="AG13";  # Bank 4, Vcco=3.3V, No DCI
463
NET  SRAM_FLASH_D13       LOC="AH12";  # Bank 4, Vcco=3.3V, No DCI
464
NET  SRAM_FLASH_D14       LOC="AH22";  # Bank 4, Vcco=3.3V, No DCI
465
NET  SRAM_FLASH_D15       LOC="AG22";  # Bank 4, Vcco=3.3V, No DCI
466
NET  SRAM_FLASH_WE_B      LOC="AF20";  # Bank 2, Vcco=3.3V
467
NET  SRAM_MODE            LOC="A13";   # Bank 20, Vcco=3.3V, DCI using 49.9 ohm resistors
468
NET  SRAM_OE_B            LOC="B12";   # Bank 20, Vcco=3.3V, DCI using 49.9 ohm resistors
469
NET  SYSACE_MPA00         LOC="G5";    # Bank 12, Vcco=3.3V, DCI using 49.9 ohm resistors
470
NET  SYSACE_MPA01_USB_A0  LOC="N7";    # Bank 12, Vcco=3.3V, DCI using 49.9 ohm resistors
471
NET  SYSACE_MPA02_USB_A1  LOC="N5";    # Bank 12, Vcco=3.3V, DCI using 49.9 ohm resistors
472
NET  SYSACE_MPA03         LOC="P5";    # Bank 12, Vcco=3.3V, DCI using 49.9 ohm resistors
473
NET  SYSACE_MPA04         LOC="R6";    # Bank 12, Vcco=3.3V, DCI using 49.9 ohm resistors
474
NET  SYSACE_MPA05         LOC="M6";    # Bank 12, Vcco=3.3V, DCI using 49.9 ohm resistors
475
NET  SYSACE_MPA06         LOC="L6";    # Bank 12, Vcco=3.3V, DCI using 49.9 ohm resistors
476
NET  SYSACE_MPBRDY        LOC="H5";    # Bank 12, Vcco=3.3V, DCI using 49.9 ohm resistors
477
NET  SYSACE_MPCE          LOC="M5";    # Bank 12, Vcco=3.3V, DCI using 49.9 ohm resistors
478
NET  SYSACE_MPIRQ         LOC="M7";    # Bank 12, Vcco=3.3V, DCI using 49.9 ohm resistors
479
NET  SYSACE_MPOE_USB_RD_B LOC="N8";    # Bank 12, Vcco=3.3V, DCI using 49.9 ohm resistors
480
NET  SYSACE_MPWE_USB_WR_B LOC="R9";    # Bank 12, Vcco=3.3V, DCI using 49.9 ohm resistors
481
NET  SYSACE_USB_D0        LOC="P9";    # Bank 12, Vcco=3.3V, DCI using 49.9 ohm resistors
482
NET  SYSACE_USB_D1        LOC="T8";    # Bank 12, Vcco=3.3V, DCI using 49.9 ohm resistors
483
NET  SYSACE_USB_D2        LOC="J7";    # Bank 12, Vcco=3.3V, DCI using 49.9 ohm resistors
484
NET  SYSACE_USB_D3        LOC="H7";    # Bank 12, Vcco=3.3V, DCI using 49.9 ohm resistors
485
NET  SYSACE_USB_D4        LOC="R7";    # Bank 12, Vcco=3.3V, DCI using 49.9 ohm resistors
486
NET  SYSACE_USB_D5        LOC="U7";    # Bank 12, Vcco=3.3V, DCI using 49.9 ohm resistors
487
NET  SYSACE_USB_D6        LOC="P7";    # Bank 12, Vcco=3.3V, DCI using 49.9 ohm resistors
488
NET  SYSACE_USB_D7        LOC="P6";    # Bank 12, Vcco=3.3V, DCI using 49.9 ohm resistors
489
NET  SYSACE_USB_D8        LOC="R8";    # Bank 12, Vcco=3.3V, DCI using 49.9 ohm resistors
490
NET  SYSACE_USB_D9        LOC="L5";    # Bank 12, Vcco=3.3V, DCI using 49.9 ohm resistors
491
NET  SYSACE_USB_D10       LOC="L4";    # Bank 12, Vcco=3.3V, DCI using 49.9 ohm resistors
492
NET  SYSACE_USB_D11       LOC="K6";    # Bank 12, Vcco=3.3V, DCI using 49.9 ohm resistors
493
NET  SYSACE_USB_D12       LOC="J5";    # Bank 12, Vcco=3.3V, DCI using 49.9 ohm resistors
494
NET  SYSACE_USB_D13       LOC="T6";    # Bank 12, Vcco=3.3V, DCI using 49.9 ohm resistors
495
NET  SYSACE_USB_D14       LOC="K7";    # Bank 12, Vcco=3.3V, DCI using 49.9 ohm resistors
496
NET  SYSACE_USB_D15       LOC="J6";    # Bank 12, Vcco=3.3V, DCI using 49.9 ohm resistors
497
NET  TRC_CLK              LOC="AD9";   # Bank 22, Vcco=3.3V, DCI using 49.9 ohm resistors
498
NET  TRC_TS1E             LOC="AK9";   # Bank 22, Vcco=3.3V, DCI using 49.9 ohm resistors
499
NET  TRC_TS1O             LOC="AF10";  # Bank 22, Vcco=3.3V, DCI using 49.9 ohm resistors
500
NET  TRC_TS2E             LOC="AK8";   # Bank 22, Vcco=3.3V, DCI using 49.9 ohm resistors
501
NET  TRC_TS2O             LOC="AF9";   # Bank 22, Vcco=3.3V, DCI using 49.9 ohm resistors
502
NET  TRC_TS3              LOC="AJ11";  # Bank 22, Vcco=3.3V, DCI using 49.9 ohm resistors
503
NET  TRC_TS4              LOC="AK11";  # Bank 22, Vcco=3.3V, DCI using 49.9 ohm resistors
504
NET  TRC_TS5              LOC="AD11";  # Bank 22, Vcco=3.3V, DCI using 49.9 ohm resistors
505
NET  TRC_TS6              LOC="AD10";  # Bank 22, Vcco=3.3V, DCI using 49.9 ohm resistors
506
NET  USB_CS_B             LOC="P10";   # Bank 12, Vcco=3.3V, DCI using 49.9 ohm resistors
507
NET  USB_INT              LOC="F5";    # Bank 12, Vcco=3.3V, DCI using 49.9 ohm resistors
508
NET  USB_RESET_B          LOC="R11";   # Bank 12, Vcco=3.3V, DCI using 49.9 ohm resistors
509
NET  USER_CLK             LOC="AH15";  # Bank 4, Vcco=3.3V, No DCI
510
NET  VGA_IN_BLUE0         LOC="AC4";   # Bank 18, Vcco=3.3V, No DCI
511
NET  VGA_IN_BLUE1         LOC="AC5";   # Bank 18, Vcco=3.3V, No DCI
512
NET  VGA_IN_BLUE2         LOC="AB6";   # Bank 18, Vcco=3.3V, No DCI
513
NET  VGA_IN_BLUE3         LOC="AB7";   # Bank 18, Vcco=3.3V, No DCI
514
NET  VGA_IN_BLUE4         LOC="AA5";   # Bank 18, Vcco=3.3V, No DCI
515
NET  VGA_IN_BLUE5         LOC="AB5";   # Bank 18, Vcco=3.3V, No DCI
516
NET  VGA_IN_BLUE6         LOC="AC7";   # Bank 18, Vcco=3.3V, No DCI
517
NET  VGA_IN_BLUE7         LOC="AD7";   # Bank 18, Vcco=3.3V, No DCI
518
NET  VGA_IN_CLAMP         LOC="AH7";   # Bank 18, Vcco=3.3V, No DCI
519
NET  VGA_IN_COAST         LOC="AG7";   # Bank 18, Vcco=3.3V, No DCI
520
NET  VGA_IN_DATA_CLK      LOC="AH18";  # Bank 4, Vcco=3.3V, No DCI
521
NET  VGA_IN_GREEN0        LOC="Y8";    # Bank 18, Vcco=3.3V, No DCI
522
NET  VGA_IN_GREEN1        LOC="Y9";    # Bank 18, Vcco=3.3V, No DCI
523
NET  VGA_IN_GREEN2        LOC="AD4";   # Bank 18, Vcco=3.3V, No DCI
524
NET  VGA_IN_GREEN3        LOC="AD5";   # Bank 18, Vcco=3.3V, No DCI
525
NET  VGA_IN_GREEN4        LOC="AA6";   # Bank 18, Vcco=3.3V, No DCI
526
NET  VGA_IN_GREEN5        LOC="Y7";    # Bank 18, Vcco=3.3V, No DCI
527
NET  VGA_IN_GREEN6        LOC="AD6";   # Bank 18, Vcco=3.3V, No DCI
528
NET  VGA_IN_GREEN7        LOC="AE6";   # Bank 18, Vcco=3.3V, No DCI
529
NET  VGA_IN_HSOUT         LOC="AE7";   # Bank 18, Vcco=3.3V, No DCI
530
NET  VGA_IN_ODD_EVEN_B    LOC="W6";    # Bank 18, Vcco=3.3V, No DCI
531
NET  VGA_IN_RED0          LOC="AG5";   # Bank 18, Vcco=3.3V, No DCI
532
NET  VGA_IN_RED1          LOC="AF5";   # Bank 18, Vcco=3.3V, No DCI
533
NET  VGA_IN_RED2          LOC="W7";    # Bank 18, Vcco=3.3V, No DCI
534
NET  VGA_IN_RED3          LOC="V7";    # Bank 18, Vcco=3.3V, No DCI
535
NET  VGA_IN_RED4          LOC="AH5";   # Bank 18, Vcco=3.3V, No DCI
536
NET  VGA_IN_RED5          LOC="AG6";   # Bank 18, Vcco=3.3V, No DCI
537
NET  VGA_IN_RED6          LOC="Y11";   # Bank 18, Vcco=3.3V, No DCI
538
NET  VGA_IN_RED7          LOC="W11";   # Bank 18, Vcco=3.3V, No DCI
539
NET  VGA_IN_SOGOUT        LOC="AF6";   # Bank 18, Vcco=3.3V, No DCI
540
NET  VGA_IN_VSOUT         LOC="Y6";    # Bank 18, Vcco=3.3V, No DCI

powered by: WebSVN 2.1.0

© copyright 1999-2024 OpenCores.org, equivalent to Oliscience, all rights reserved. OpenCores®, registered trademark.