OpenCores
URL https://opencores.org/ocsvn/openrisc/openrisc/trunk

Subversion Repositories openrisc

[/] [openrisc/] [trunk/] [gnu-dev/] [or1k-gcc/] [gcc/] [ada/] [lib-load.adb] - Blame information for rev 801

Go to most recent revision | Details | Compare with Previous | View Log

Line No. Rev Author Line
1 706 jeremybenn
------------------------------------------------------------------------------
2
--                                                                          --
3
--                         GNAT COMPILER COMPONENTS                         --
4
--                                                                          --
5
--                             L I B . L O A D                              --
6
--                                                                          --
7
--                                 B o d y                                  --
8
--                                                                          --
9
--          Copyright (C) 1992-2012, Free Software Foundation, Inc.         --
10
--                                                                          --
11
-- GNAT is free software;  you can  redistribute it  and/or modify it under --
12
-- terms of the  GNU General Public License as published  by the Free Soft- --
13
-- ware  Foundation;  either version 3,  or (at your option) any later ver- --
14
-- sion.  GNAT is distributed in the hope that it will be useful, but WITH- --
15
-- OUT ANY WARRANTY;  without even the  implied warranty of MERCHANTABILITY --
16
-- or FITNESS FOR A PARTICULAR PURPOSE.  See the GNU General Public License --
17
-- for  more details.  You should have  received  a copy of the GNU General --
18
-- Public License  distributed with GNAT; see file COPYING3.  If not, go to --
19
-- http://www.gnu.org/licenses for a complete copy of the license.          --
20
--                                                                          --
21
-- GNAT was originally developed  by the GNAT team at  New York University. --
22
-- Extensive contributions were provided by Ada Core Technologies Inc.      --
23
--                                                                          --
24
------------------------------------------------------------------------------
25
 
26
with Atree;    use Atree;
27
with Debug;    use Debug;
28
with Einfo;    use Einfo;
29
with Errout;   use Errout;
30
with Fname;    use Fname;
31
with Fname.UF; use Fname.UF;
32
with Nlists;   use Nlists;
33
with Nmake;    use Nmake;
34
with Opt;      use Opt;
35
with Osint;    use Osint;
36
with Osint.C;  use Osint.C;
37
with Output;   use Output;
38
with Par;
39
with Restrict; use Restrict;
40
with Scn;      use Scn;
41
with Sinfo;    use Sinfo;
42
with Sinput;   use Sinput;
43
with Sinput.L; use Sinput.L;
44
with Stand;    use Stand;
45
with Tbuild;   use Tbuild;
46
with Uname;    use Uname;
47
 
48
package body Lib.Load is
49
 
50
   -----------------------
51
   -- Local Subprograms --
52
   -----------------------
53
 
54
   function From_Limited_With_Chain return Boolean;
55
   --  Check whether a possible circular dependence includes units that
56
   --  have been loaded through limited_with clauses, in which case there
57
   --  is no real circularity.
58
 
59
   function Spec_Is_Irrelevant
60
     (Spec_Unit : Unit_Number_Type;
61
      Body_Unit : Unit_Number_Type) return Boolean;
62
   --  The Spec_Unit and Body_Unit parameters are the unit numbers of the
63
   --  spec file that corresponds to the main unit which is a body. This
64
   --  function determines if the spec file is irrelevant and will be
65
   --  overridden by the body as described in RM 10.1.4(4). See description
66
   --  in "Special Handling of Subprogram Bodies" for further details.
67
 
68
   procedure Write_Dependency_Chain;
69
   --  This procedure is used to generate error message info lines that
70
   --  trace the current dependency chain when a load error occurs.
71
 
72
   ------------------------------
73
   -- Change_Main_Unit_To_Spec --
74
   ------------------------------
75
 
76
   procedure Change_Main_Unit_To_Spec is
77
      U : Unit_Record renames Units.Table (Main_Unit);
78
      N : File_Name_Type;
79
      X : Source_File_Index;
80
 
81
   begin
82
      --  Get name of unit body
83
 
84
      Get_Name_String (U.Unit_File_Name);
85
 
86
      --  Note: for the following we should really generalize and consult the
87
      --  file name pattern data, but for now we just deal with the common
88
      --  naming cases, which is probably good enough in practice ???
89
 
90
      --  Change .adb to .ads
91
 
92
      if Name_Len >= 5
93
        and then Name_Buffer (Name_Len - 3 .. Name_Len) = ".adb"
94
      then
95
         Name_Buffer (Name_Len) := 's';
96
 
97
      --  Change .2.ada to .1.ada (Rational convention)
98
 
99
      elsif Name_Len >= 7
100
        and then Name_Buffer (Name_Len - 5 .. Name_Len) = ".2.ada"
101
      then
102
         Name_Buffer (Name_Len - 4) := '1';
103
 
104
      --  Change .ada to _.ada (DEC convention)
105
 
106
      elsif Name_Len >= 5
107
        and then Name_Buffer (Name_Len - 3 .. Name_Len) = ".ada"
108
      then
109
         Name_Buffer (Name_Len - 3 .. Name_Len + 1) := "_.ada";
110
         Name_Len := Name_Len + 1;
111
 
112
      --  No match, don't make the change
113
 
114
      else
115
         return;
116
      end if;
117
 
118
      --  Try loading the spec
119
 
120
      N := Name_Find;
121
      X := Load_Source_File (N);
122
 
123
      --  No change if we did not find the spec
124
 
125
      if X = No_Source_File then
126
         return;
127
      end if;
128
 
129
      --  Otherwise modify Main_Unit entry to point to spec
130
 
131
      U.Unit_File_Name := N;
132
      U.Source_Index := X;
133
   end Change_Main_Unit_To_Spec;
134
 
135
   -------------------------------
136
   -- Create_Dummy_Package_Unit --
137
   -------------------------------
138
 
139
   function Create_Dummy_Package_Unit
140
     (With_Node : Node_Id;
141
      Spec_Name : Unit_Name_Type) return Unit_Number_Type
142
   is
143
      Unum         : Unit_Number_Type;
144
      Cunit_Entity : Entity_Id;
145
      Cunit        : Node_Id;
146
      Du_Name      : Node_Or_Entity_Id;
147
      End_Lab      : Node_Id;
148
      Save_CS      : constant Boolean := Get_Comes_From_Source_Default;
149
 
150
   begin
151
      --  The created dummy package unit does not come from source
152
 
153
      Set_Comes_From_Source_Default (False);
154
 
155
      --  Normal package
156
 
157
      if Nkind (Name (With_Node)) = N_Identifier then
158
         Cunit_Entity :=
159
           Make_Defining_Identifier (No_Location,
160
             Chars => Chars (Name (With_Node)));
161
         Du_Name := Cunit_Entity;
162
         End_Lab := New_Occurrence_Of (Cunit_Entity, No_Location);
163
 
164
      --  Child package
165
 
166
      else
167
         Cunit_Entity :=
168
           Make_Defining_Identifier (No_Location,
169
             Chars => Chars (Selector_Name (Name (With_Node))));
170
         Du_Name :=
171
           Make_Defining_Program_Unit_Name (No_Location,
172
             Name => Copy_Separate_Tree (Prefix (Name (With_Node))),
173
             Defining_Identifier => Cunit_Entity);
174
 
175
         Set_Is_Child_Unit (Cunit_Entity);
176
 
177
         End_Lab :=
178
           Make_Designator (No_Location,
179
             Name => Copy_Separate_Tree (Prefix (Name (With_Node))),
180
             Identifier => New_Occurrence_Of (Cunit_Entity, No_Location));
181
      end if;
182
 
183
      Set_Scope (Cunit_Entity, Standard_Standard);
184
 
185
      Cunit :=
186
        Make_Compilation_Unit (No_Location,
187
          Context_Items => Empty_List,
188
          Unit =>
189
            Make_Package_Declaration (No_Location,
190
              Specification =>
191
                Make_Package_Specification (No_Location,
192
                  Defining_Unit_Name   => Du_Name,
193
                  Visible_Declarations => Empty_List,
194
                  End_Label            => End_Lab)),
195
          Aux_Decls_Node =>
196
            Make_Compilation_Unit_Aux (No_Location));
197
 
198
      --  Mark the dummy package as analyzed to prevent analysis of this
199
      --  (non-existent) unit in -gnatQ mode because at the moment the
200
      --  structure and attributes of this dummy package does not allow
201
      --  a normal analysis of this unit
202
 
203
      Set_Analyzed (Cunit);
204
 
205
      Units.Increment_Last;
206
      Unum := Units.Last;
207
 
208
      Units.Table (Unum) := (
209
        Cunit            => Cunit,
210
        Cunit_Entity     => Cunit_Entity,
211
        Dependency_Num   => 0,
212
        Dynamic_Elab     => False,
213
        Error_Location   => Sloc (With_Node),
214
        Expected_Unit    => Spec_Name,
215
        Fatal_Error      => True,
216
        Generate_Code    => False,
217
        Has_Allocator    => False,
218
        Has_RACW         => False,
219
        Is_Compiler_Unit => False,
220
        Ident_String     => Empty,
221
        Loading          => False,
222
        Main_Priority    => Default_Main_Priority,
223
        Main_CPU         => Default_Main_CPU,
224
        Munit_Index      => 0,
225
        Serial_Number    => 0,
226
        Source_Index     => No_Source_File,
227
        Unit_File_Name   => Get_File_Name (Spec_Name, Subunit => False),
228
        Unit_Name        => Spec_Name,
229
        Version          => 0,
230
        OA_Setting       => 'O');
231
 
232
      Set_Comes_From_Source_Default (Save_CS);
233
      Set_Error_Posted (Cunit_Entity);
234
      Set_Error_Posted (Cunit);
235
      return Unum;
236
   end Create_Dummy_Package_Unit;
237
 
238
   -----------------------------
239
   -- From_Limited_With_Chain --
240
   -----------------------------
241
 
242
   function From_Limited_With_Chain return Boolean is
243
      Curr_Num : constant Unit_Number_Type :=
244
                   Load_Stack.Table (Load_Stack.Last).Unit_Number;
245
 
246
   begin
247
      --  True if the current load operation is through a limited_with clause
248
      --  and we are not within a loop of regular with_clauses.
249
 
250
      for U in reverse Load_Stack.First .. Load_Stack.Last - 1 loop
251
         if Load_Stack.Table (U).Unit_Number = Curr_Num then
252
            return False;
253
 
254
         elsif Present (Load_Stack.Table (U).With_Node)
255
           and then Limited_Present (Load_Stack.Table (U).With_Node)
256
         then
257
            return True;
258
         end if;
259
      end loop;
260
 
261
      return False;
262
   end From_Limited_With_Chain;
263
 
264
   ----------------
265
   -- Initialize --
266
   ----------------
267
 
268
   procedure Initialize is
269
   begin
270
      Units.Init;
271
      Load_Stack.Init;
272
   end Initialize;
273
 
274
   ------------------------
275
   -- Initialize_Version --
276
   ------------------------
277
 
278
   procedure Initialize_Version (U : Unit_Number_Type) is
279
   begin
280
      Units.Table (U).Version := Source_Checksum (Source_Index (U));
281
   end Initialize_Version;
282
 
283
   ----------------------
284
   -- Load_Main_Source --
285
   ----------------------
286
 
287
   procedure Load_Main_Source is
288
      Fname   : File_Name_Type;
289
      Version : Word := 0;
290
 
291
   begin
292
      Load_Stack.Increment_Last;
293
      Load_Stack.Table (Load_Stack.Last) := (Main_Unit, Empty);
294
 
295
      --  Initialize unit table entry for Main_Unit. Note that we don't know
296
      --  the unit name yet, that gets filled in when the parser parses the
297
      --  main unit, at which time a check is made that it matches the main
298
      --  file name, and then the Unit_Name field is set. The Cunit and
299
      --  Cunit_Entity fields also get filled in later by the parser.
300
 
301
      Units.Increment_Last;
302
      Fname := Next_Main_Source;
303
 
304
      Units.Table (Main_Unit).Unit_File_Name := Fname;
305
 
306
      if Fname /= No_File then
307
         Main_Source_File := Load_Source_File (Fname);
308
         Current_Error_Source_File := Main_Source_File;
309
 
310
         if Main_Source_File /= No_Source_File then
311
            Version := Source_Checksum (Main_Source_File);
312
         end if;
313
 
314
         Units.Table (Main_Unit) := (
315
           Cunit            => Empty,
316
           Cunit_Entity     => Empty,
317
           Dependency_Num   => 0,
318
           Dynamic_Elab     => False,
319
           Error_Location   => No_Location,
320
           Expected_Unit    => No_Unit_Name,
321
           Fatal_Error      => False,
322
           Generate_Code    => False,
323
           Has_Allocator    => False,
324
           Has_RACW         => False,
325
           Is_Compiler_Unit => False,
326
           Ident_String     => Empty,
327
           Loading          => True,
328
           Main_Priority    => Default_Main_Priority,
329
           Main_CPU         => Default_Main_CPU,
330
           Munit_Index      => 0,
331
           Serial_Number    => 0,
332
           Source_Index     => Main_Source_File,
333
           Unit_File_Name   => Fname,
334
           Unit_Name        => No_Unit_Name,
335
           Version          => Version,
336
           OA_Setting       => 'O');
337
      end if;
338
   end Load_Main_Source;
339
 
340
   ---------------
341
   -- Load_Unit --
342
   ---------------
343
 
344
   function Load_Unit
345
     (Load_Name         : Unit_Name_Type;
346
      Required          : Boolean;
347
      Error_Node        : Node_Id;
348
      Subunit           : Boolean;
349
      Corr_Body         : Unit_Number_Type := No_Unit;
350
      Renamings         : Boolean          := False;
351
      With_Node         : Node_Id          := Empty;
352
      PMES              : Boolean          := False) return Unit_Number_Type
353
   is
354
      Calling_Unit : Unit_Number_Type;
355
      Uname_Actual : Unit_Name_Type;
356
      Unum         : Unit_Number_Type;
357
      Unump        : Unit_Number_Type;
358
      Fname        : File_Name_Type;
359
      Src_Ind      : Source_File_Index;
360
      Save_PMES    : constant Boolean := Parsing_Main_Extended_Source;
361
 
362
      Save_Cunit_Restrictions : constant Save_Cunit_Boolean_Restrictions :=
363
                                  Cunit_Boolean_Restrictions_Save;
364
      --  Save current restrictions for restore at end
365
 
366
   begin
367
      Parsing_Main_Extended_Source := PMES;
368
 
369
      --  Initialize restrictions to config restrictions for unit to load if
370
      --  it is part of the main extended source, otherwise reset them.
371
 
372
      --  Note: it's a bit odd but PMES is False for subunits, which is why
373
      --  we have the OR here. Should be investigated some time???
374
 
375
      if PMES or Subunit then
376
         Restore_Config_Cunit_Boolean_Restrictions;
377
      else
378
         Reset_Cunit_Boolean_Restrictions;
379
      end if;
380
 
381
      --  If renamings are allowed and we have a child unit name, then we
382
      --  must first load the parent to deal with finding the real name.
383
      --  Retain the with_clause that names the child, so that if it is
384
      --  limited, the parent is loaded under the same condition.
385
 
386
      if Renamings and then Is_Child_Name (Load_Name) then
387
         Unump :=
388
           Load_Unit
389
             (Load_Name  => Get_Parent_Spec_Name (Load_Name),
390
              Required   => Required,
391
              Subunit    => False,
392
              Renamings  => True,
393
              Error_Node => Error_Node,
394
              With_Node  => With_Node);
395
 
396
         if Unump = No_Unit then
397
            Parsing_Main_Extended_Source := Save_PMES;
398
            return No_Unit;
399
         end if;
400
 
401
         --  If parent is a renaming, then we use the renamed package as
402
         --  the actual parent for the subsequent load operation.
403
 
404
         if Nkind (Unit (Cunit (Unump))) = N_Package_Renaming_Declaration then
405
            Uname_Actual :=
406
              New_Child
407
                (Load_Name, Get_Unit_Name (Name (Unit (Cunit (Unump)))));
408
 
409
            --  If the load is for a with_clause, for visibility purposes both
410
            --  the renamed entity and renaming one must be available in the
411
            --  current unit: the renamed one in order to retrieve the child
412
            --  unit, and the original one because it may be used as a prefix
413
            --  in the body of the current unit. We add an explicit with_clause
414
            --  for the original parent so that the renaming declaration is
415
            --  properly loaded and analyzed.
416
 
417
            if Present (With_Node) then
418
               Insert_After (With_Node,
419
                 Make_With_Clause (Sloc (With_Node),
420
                   Name => Copy_Separate_Tree (Prefix (Name (With_Node)))));
421
            end if;
422
 
423
            --  Save the renaming entity, to establish its visibility when
424
            --  installing the context. The implicit with is on this entity,
425
            --  not on the package it renames. This is somewhat redundant given
426
            --  the with_clause just created, but it simplifies subsequent
427
            --  expansion of the current with_clause. Optimizable ???
428
 
429
            if Nkind (Error_Node) = N_With_Clause
430
              and then Nkind (Name (Error_Node)) = N_Selected_Component
431
            then
432
               declare
433
                  Par : Node_Id := Name (Error_Node);
434
 
435
               begin
436
                  while Nkind (Par) = N_Selected_Component
437
                    and then Chars (Selector_Name (Par)) /=
438
                             Chars (Cunit_Entity (Unump))
439
                  loop
440
                     Par := Prefix (Par);
441
                  end loop;
442
 
443
                  --  Case of some intermediate parent is a renaming
444
 
445
                  if Nkind (Par) = N_Selected_Component then
446
                     Set_Entity (Selector_Name (Par), Cunit_Entity (Unump));
447
 
448
                  --  Case where the ultimate parent is a renaming
449
 
450
                  else
451
                     Set_Entity (Par, Cunit_Entity (Unump));
452
                  end if;
453
               end;
454
            end if;
455
 
456
         --  If the parent is not a renaming, then get its name (this may
457
         --  be different from the parent spec name obtained above because
458
         --  of renamings higher up in the hierarchy).
459
 
460
         else
461
            Uname_Actual := New_Child (Load_Name, Unit_Name (Unump));
462
         end if;
463
 
464
      --  Here if unit to be loaded is not a child unit
465
 
466
      else
467
         Uname_Actual := Load_Name;
468
      end if;
469
 
470
      Fname := Get_File_Name (Uname_Actual, Subunit);
471
 
472
      if Debug_Flag_L then
473
         Write_Eol;
474
         Write_Str ("*** Load request for unit: ");
475
         Write_Unit_Name (Load_Name);
476
 
477
         if Required then
478
            Write_Str (" (Required = True)");
479
         else
480
            Write_Str (" (Required = False)");
481
         end if;
482
 
483
         Write_Eol;
484
 
485
         if Uname_Actual /= Load_Name then
486
            Write_Str ("*** Actual unit loaded: ");
487
            Write_Unit_Name (Uname_Actual);
488
         end if;
489
      end if;
490
 
491
      --  Capture error location if it is for the main unit. The idea is to
492
      --  post errors on the main unit location, not the most recent unit.
493
      --  Note: Unit_Name (Main_Unit) is not set if we are parsing gnat.adc.
494
 
495
      if Present (Error_Node)
496
        and then Unit_Name (Main_Unit) /= No_Unit_Name
497
      then
498
         --  It seems like In_Extended_Main_Source_Unit (Error_Node) would
499
         --  do the trick here, but that's wrong, it is much too early to
500
         --  call this routine. We are still in the parser, and the required
501
         --  semantic information is not established yet. So we base the
502
         --  judgment on unit names.
503
 
504
         Get_External_Unit_Name_String (Unit_Name (Main_Unit));
505
 
506
         declare
507
            Main_Unit_Name : constant String := Name_Buffer (1 .. Name_Len);
508
 
509
         begin
510
            Get_External_Unit_Name_String
511
              (Unit_Name (Get_Source_Unit (Error_Node)));
512
 
513
            --  If the two names are identical, then for sure we are part
514
            --  of the extended main unit
515
 
516
            if Main_Unit_Name = Name_Buffer (1 .. Name_Len) then
517
               Load_Msg_Sloc := Sloc (Error_Node);
518
 
519
            --  If the load is called from a with_type clause, the error
520
            --  node is correct.
521
 
522
            --  Otherwise, check for the subunit case, and if so, consider
523
            --  we have a match if one name is a prefix of the other name.
524
 
525
            else
526
               if Nkind (Unit (Cunit (Main_Unit))) = N_Subunit
527
                    or else
528
                  Nkind (Unit (Cunit (Get_Source_Unit (Error_Node)))) =
529
                                                                N_Subunit
530
               then
531
                  Name_Len := Integer'Min (Name_Len, Main_Unit_Name'Length);
532
 
533
                  if Name_Buffer (1 .. Name_Len)
534
                        =
535
                     Main_Unit_Name (1 .. Name_Len)
536
                  then
537
                     Load_Msg_Sloc := Sloc (Error_Node);
538
                  end if;
539
               end if;
540
            end if;
541
         end;
542
      end if;
543
 
544
      --  If we are generating error messages, then capture calling unit
545
 
546
      if Present (Error_Node) then
547
         Calling_Unit := Get_Source_Unit (Error_Node);
548
      else
549
         Calling_Unit := No_Unit;
550
      end if;
551
 
552
      --  See if we already have an entry for this unit
553
 
554
      Unum := Main_Unit;
555
      while Unum <= Units.Last loop
556
         exit when Uname_Actual = Units.Table (Unum).Unit_Name;
557
         Unum := Unum + 1;
558
      end loop;
559
 
560
      --  Whether or not the entry was found, Unum is now the right value,
561
      --  since it is one more than Units.Last (i.e. the index of the new
562
      --  entry we will create) in the not found case.
563
 
564
      --  A special check is necessary in the unit not found case. If the unit
565
      --  is not found, but the file in which it lives has already been loaded,
566
      --  then we have the problem that the file does not contain the unit that
567
      --  is needed. We simply treat this as a file not found condition.
568
 
569
      --  We skip this test in multiple unit per file mode since in this
570
      --  case we can have multiple units from the same source file.
571
 
572
      if Unum > Units.Last and then Get_Unit_Index (Uname_Actual) = 0 then
573
         for J in Units.First .. Units.Last loop
574
            if Fname = Units.Table (J).Unit_File_Name then
575
               if Debug_Flag_L then
576
                  Write_Str ("  file does not contain unit, Unit_Number = ");
577
                  Write_Int (Int (Unum));
578
                  Write_Eol;
579
                  Write_Eol;
580
               end if;
581
 
582
               if Present (Error_Node) then
583
                  if Is_Predefined_File_Name (Fname) then
584
                     Error_Msg_Unit_1 := Uname_Actual;
585
                     Error_Msg
586
                       ("$$ is not a language defined unit", Load_Msg_Sloc);
587
                  else
588
                     Error_Msg_File_1 := Fname;
589
                     Error_Msg_Unit_1 := Uname_Actual;
590
                     Error_Msg ("File{ does not contain unit$", Load_Msg_Sloc);
591
                  end if;
592
 
593
                  Write_Dependency_Chain;
594
                  Unum := No_Unit;
595
                  goto Done;
596
 
597
               else
598
                  Unum := No_Unit;
599
                  goto Done;
600
               end if;
601
            end if;
602
         end loop;
603
      end if;
604
 
605
      --  If we are proceeding with load, then make load stack entry,
606
      --  and indicate the kind of with_clause responsible for the load.
607
 
608
      Load_Stack.Increment_Last;
609
      Load_Stack.Table (Load_Stack.Last) := (Unum, With_Node);
610
 
611
      --  Case of entry already in table
612
 
613
      if Unum <= Units.Last then
614
 
615
         --  Here is where we check for a circular dependency, which is
616
         --  an attempt to load a unit which is currently in the process
617
         --  of being loaded. We do *not* care about a circular chain that
618
         --  leads back to a body, because this kind of circular dependence
619
         --  legitimately occurs (e.g. two package bodies that contain
620
         --  inlined subprogram referenced by the other).
621
 
622
         --  Ada 2005 (AI-50217): We also ignore limited_with clauses, because
623
         --  their purpose is precisely to create legal circular structures.
624
 
625
         if Loading (Unum)
626
           and then (Is_Spec_Name (Units.Table (Unum).Unit_Name)
627
                       or else Acts_As_Spec (Units.Table (Unum).Cunit))
628
           and then (Nkind (Error_Node) /= N_With_Clause
629
                       or else not Limited_Present (Error_Node))
630
           and then not From_Limited_With_Chain
631
         then
632
            if Debug_Flag_L then
633
               Write_Str ("  circular dependency encountered");
634
               Write_Eol;
635
            end if;
636
 
637
            if Present (Error_Node) then
638
               Error_Msg ("circular unit dependency", Load_Msg_Sloc);
639
               Write_Dependency_Chain;
640
            else
641
               Load_Stack.Decrement_Last;
642
            end if;
643
 
644
            Unum := No_Unit;
645
            goto Done;
646
         end if;
647
 
648
         if Debug_Flag_L then
649
            Write_Str ("  unit already in file table, Unit_Number = ");
650
            Write_Int (Int (Unum));
651
            Write_Eol;
652
         end if;
653
 
654
         Load_Stack.Decrement_Last;
655
         goto Done;
656
 
657
      --  Unit is not already in table, so try to open the file
658
 
659
      else
660
         if Debug_Flag_L then
661
            Write_Str ("  attempt unit load, Unit_Number = ");
662
            Write_Int (Int (Unum));
663
            Write_Eol;
664
         end if;
665
 
666
         Src_Ind := Load_Source_File (Fname);
667
 
668
         --  Make a partial entry in the file table, used even in the file not
669
         --  found case to print the dependency chain including the last entry
670
 
671
         Units.Increment_Last;
672
         Units.Table (Unum).Unit_Name := Uname_Actual;
673
 
674
         --  File was found
675
 
676
         if Src_Ind /= No_Source_File then
677
            Units.Table (Unum) := (
678
              Cunit            => Empty,
679
              Cunit_Entity     => Empty,
680
              Dependency_Num   => 0,
681
              Dynamic_Elab     => False,
682
              Error_Location   => Sloc (Error_Node),
683
              Expected_Unit    => Uname_Actual,
684
              Fatal_Error      => False,
685
              Generate_Code    => False,
686
              Has_Allocator    => False,
687
              Has_RACW         => False,
688
              Is_Compiler_Unit => False,
689
              Ident_String     => Empty,
690
              Loading          => True,
691
              Main_Priority    => Default_Main_Priority,
692
              Main_CPU         => Default_Main_CPU,
693
              Munit_Index      => 0,
694
              Serial_Number    => 0,
695
              Source_Index     => Src_Ind,
696
              Unit_File_Name   => Fname,
697
              Unit_Name        => Uname_Actual,
698
              Version          => Source_Checksum (Src_Ind),
699
              OA_Setting       => 'O');
700
 
701
            --  Parse the new unit
702
 
703
            declare
704
               Save_Index : constant Nat     := Multiple_Unit_Index;
705
               Save_PMES  : constant Boolean := Parsing_Main_Extended_Source;
706
 
707
            begin
708
               Multiple_Unit_Index := Get_Unit_Index (Uname_Actual);
709
               Units.Table (Unum).Munit_Index := Multiple_Unit_Index;
710
               Initialize_Scanner (Unum, Source_Index (Unum));
711
 
712
               if Calling_Unit = Main_Unit and then Subunit then
713
                  Parsing_Main_Extended_Source := True;
714
               end if;
715
 
716
               Discard_List (Par (Configuration_Pragmas => False));
717
 
718
               Parsing_Main_Extended_Source := Save_PMES;
719
 
720
               Multiple_Unit_Index := Save_Index;
721
               Set_Loading (Unum, False);
722
            end;
723
 
724
            --  If spec is irrelevant, then post errors and quit
725
 
726
            if Corr_Body /= No_Unit
727
              and then Spec_Is_Irrelevant (Unum, Corr_Body)
728
            then
729
               Error_Msg_File_1 := Unit_File_Name (Corr_Body);
730
               Error_Msg
731
                 ("cannot compile subprogram in file {!", Load_Msg_Sloc);
732
               Error_Msg_File_1 := Unit_File_Name (Unum);
733
               Error_Msg
734
                 ("\incorrect spec in file { must be removed first!",
735
                  Load_Msg_Sloc);
736
               Unum := No_Unit;
737
               goto Done;
738
            end if;
739
 
740
            --  If loaded unit had a fatal error, then caller inherits it!
741
 
742
            if Units.Table (Unum).Fatal_Error
743
              and then Present (Error_Node)
744
            then
745
               Units.Table (Calling_Unit).Fatal_Error := True;
746
            end if;
747
 
748
            --  Remove load stack entry and return the entry in the file table
749
 
750
            Load_Stack.Decrement_Last;
751
 
752
            --  All done, return unit number
753
 
754
            goto Done;
755
 
756
         --  Case of file not found
757
 
758
         else
759
            if Debug_Flag_L then
760
               Write_Str ("  file was not found, load failed");
761
               Write_Eol;
762
            end if;
763
 
764
            --  Generate message if unit required
765
 
766
            if Required and then Present (Error_Node) then
767
               if Is_Predefined_File_Name (Fname) then
768
 
769
                  --  This is a predefined library unit which is not present
770
                  --  in the run time. If a predefined unit is not available
771
                  --  it may very likely be the case that there is also pragma
772
                  --  Restriction forbidding its usage. This is typically the
773
                  --  case when building a configurable run time, where the
774
                  --  usage of certain run-time units is restricted by means
775
                  --  of both the corresponding pragma Restriction (such as
776
                  --  No_Calendar), and by not including the unit. Hence, we
777
                  --  check whether this predefined unit is forbidden, so that
778
                  --  the message about the restriction violation is generated,
779
                  --  if needed.
780
 
781
                  Check_Restricted_Unit (Load_Name, Error_Node);
782
 
783
                  Error_Msg_Unit_1 := Uname_Actual;
784
                  Error_Msg -- CODEFIX
785
                    ("$$ is not a predefined library unit", Load_Msg_Sloc);
786
 
787
               else
788
                  Error_Msg_File_1 := Fname;
789
                  Error_Msg ("file{ not found", Load_Msg_Sloc);
790
               end if;
791
 
792
               Write_Dependency_Chain;
793
 
794
               --  Remove unit from stack, to avoid cascaded errors on
795
               --  subsequent missing files.
796
 
797
               Load_Stack.Decrement_Last;
798
               Units.Decrement_Last;
799
 
800
            --  If unit not required, remove load stack entry and the junk
801
            --  file table entry, and return No_Unit to indicate not found,
802
 
803
            else
804
               Load_Stack.Decrement_Last;
805
               Units.Decrement_Last;
806
            end if;
807
 
808
            Unum := No_Unit;
809
            goto Done;
810
         end if;
811
      end if;
812
 
813
      --  Here to exit, with result in Unum
814
 
815
      <<Done>>
816
      Parsing_Main_Extended_Source := Save_PMES;
817
      Cunit_Boolean_Restrictions_Restore (Save_Cunit_Restrictions);
818
      return Unum;
819
   end Load_Unit;
820
 
821
   --------------------------
822
   -- Make_Child_Decl_Unit --
823
   --------------------------
824
 
825
   procedure Make_Child_Decl_Unit (N : Node_Id) is
826
      Unit_Decl : constant Node_Id := Library_Unit (N);
827
 
828
   begin
829
      Units.Increment_Last;
830
      Units.Table (Units.Last) := Units.Table (Get_Cunit_Unit_Number (N));
831
      Units.Table (Units.Last).Unit_Name :=
832
        Get_Spec_Name (Unit_Name (Get_Cunit_Unit_Number (N)));
833
      Units.Table (Units.Last).Cunit := Unit_Decl;
834
      Units.Table (Units.Last).Cunit_Entity  :=
835
        Defining_Identifier
836
          (Defining_Unit_Name (Specification (Unit (Unit_Decl))));
837
 
838
      --  The library unit created for of a child subprogram unit plays no
839
      --  role in code generation and binding, so label it accordingly.
840
 
841
      Units.Table (Units.Last).Generate_Code := False;
842
      Set_Has_No_Elaboration_Code (Unit_Decl);
843
   end Make_Child_Decl_Unit;
844
 
845
   ------------------------
846
   -- Make_Instance_Unit --
847
   ------------------------
848
 
849
   --  If the unit is an instance, it appears as a package declaration, but
850
   --  contains both declaration and body of the instance. The body becomes
851
   --  the main unit of the compilation, and the declaration is inserted
852
   --  at the end of the unit table. The main unit now has the name of a
853
   --  body, which is constructed from the name of the original spec,
854
   --  and is attached to the compilation node of the original unit. The
855
   --  declaration has been attached to a new compilation unit node, and
856
   --  code will have to be generated for it.
857
 
858
   procedure Make_Instance_Unit (N : Node_Id; In_Main : Boolean) is
859
      Sind : constant Source_File_Index := Source_Index (Main_Unit);
860
 
861
   begin
862
      Units.Increment_Last;
863
 
864
      if In_Main then
865
         Units.Table (Units.Last)               := Units.Table (Main_Unit);
866
         Units.Table (Units.Last).Cunit         := Library_Unit (N);
867
         Units.Table (Units.Last).Generate_Code := True;
868
         Units.Table (Main_Unit).Cunit          := N;
869
         Units.Table (Main_Unit).Unit_Name      :=
870
           Get_Body_Name
871
             (Unit_Name (Get_Cunit_Unit_Number (Library_Unit (N))));
872
         Units.Table (Main_Unit).Version        := Source_Checksum (Sind);
873
 
874
      else
875
         --  Duplicate information from instance unit, for the body. The unit
876
         --  node N has been rewritten as a body, but it was placed in the
877
         --  units table when first loaded as a declaration.
878
 
879
         Units.Table (Units.Last) := Units.Table (Get_Cunit_Unit_Number (N));
880
         Units.Table (Units.Last).Cunit := Library_Unit (N);
881
      end if;
882
   end Make_Instance_Unit;
883
 
884
   ------------------------
885
   -- Spec_Is_Irrelevant --
886
   ------------------------
887
 
888
   function Spec_Is_Irrelevant
889
     (Spec_Unit : Unit_Number_Type;
890
      Body_Unit : Unit_Number_Type) return Boolean
891
   is
892
      Sunit : constant Node_Id := Cunit (Spec_Unit);
893
      Bunit : constant Node_Id := Cunit (Body_Unit);
894
 
895
   begin
896
      --  The spec is irrelevant if the body is a subprogram body, and the spec
897
      --  is other than a subprogram spec or generic subprogram spec. Note that
898
      --  the names must be the same, we don't need to check that, because we
899
      --  already know that from the fact that the file names are the same.
900
 
901
      return
902
         Nkind (Unit (Bunit)) = N_Subprogram_Body
903
           and then Nkind (Unit (Sunit)) /= N_Subprogram_Declaration
904
           and then Nkind (Unit (Sunit)) /= N_Generic_Subprogram_Declaration;
905
   end Spec_Is_Irrelevant;
906
 
907
   --------------------
908
   -- Version_Update --
909
   --------------------
910
 
911
   procedure Version_Update (U : Node_Id; From : Node_Id) is
912
      Unum  : constant Unit_Number_Type := Get_Cunit_Unit_Number (U);
913
      Fnum  : constant Unit_Number_Type := Get_Cunit_Unit_Number (From);
914
   begin
915
      if Source_Index (Fnum) /= No_Source_File then
916
         Units.Table (Unum).Version :=
917
           Units.Table (Unum).Version
918
             xor
919
              Source_Checksum (Source_Index (Fnum));
920
      end if;
921
   end Version_Update;
922
 
923
   ----------------------------
924
   -- Write_Dependency_Chain --
925
   ----------------------------
926
 
927
   procedure Write_Dependency_Chain is
928
   begin
929
      --  The dependency chain is only written if it is at least two entries
930
      --  deep, otherwise it is trivial (the main unit depending on a unit
931
      --  that it obviously directly depends on).
932
 
933
      if Load_Stack.Last - 1 > Load_Stack.First then
934
         for U in Load_Stack.First .. Load_Stack.Last - 1 loop
935
            Error_Msg_Unit_1 :=
936
              Unit_Name (Load_Stack.Table (U).Unit_Number);
937
            Error_Msg_Unit_2 :=
938
              Unit_Name (Load_Stack.Table (U + 1).Unit_Number);
939
            Error_Msg ("$ depends on $!", Load_Msg_Sloc);
940
         end loop;
941
      end if;
942
   end Write_Dependency_Chain;
943
 
944
end Lib.Load;

powered by: WebSVN 2.1.0

© copyright 1999-2024 OpenCores.org, equivalent to Oliscience, all rights reserved. OpenCores®, registered trademark.