OpenCores
URL https://opencores.org/ocsvn/openrisc/openrisc/trunk

Subversion Repositories openrisc

[/] [openrisc/] [trunk/] [gnu-dev/] [or1k-gcc/] [gcc/] [ada/] [lib.adb] - Blame information for rev 801

Go to most recent revision | Details | Compare with Previous | View Log

Line No. Rev Author Line
1 706 jeremybenn
------------------------------------------------------------------------------
2
--                                                                          --
3
--                         GNAT COMPILER COMPONENTS                         --
4
--                                                                          --
5
--                                  L I B                                   --
6
--                                                                          --
7
--                                 B o d y                                  --
8
--                                                                          --
9
--          Copyright (C) 1992-2011, Free Software Foundation, Inc.         --
10
--                                                                          --
11
-- GNAT is free software;  you can  redistribute it  and/or modify it under --
12
-- terms of the  GNU General Public License as published  by the Free Soft- --
13
-- ware  Foundation;  either version 3,  or (at your option) any later ver- --
14
-- sion.  GNAT is distributed in the hope that it will be useful, but WITH- --
15
-- OUT ANY WARRANTY;  without even the  implied warranty of MERCHANTABILITY --
16
-- or FITNESS FOR A PARTICULAR PURPOSE.                                     --
17
--                                                                          --
18
-- As a special exception under Section 7 of GPL version 3, you are granted --
19
-- additional permissions described in the GCC Runtime Library Exception,   --
20
-- version 3.1, as published by the Free Software Foundation.               --
21
--                                                                          --
22
-- You should have received a copy of the GNU General Public License and    --
23
-- a copy of the GCC Runtime Library Exception along with this program;     --
24
-- see the files COPYING3 and COPYING.RUNTIME respectively.  If not, see    --
25
-- <http://www.gnu.org/licenses/>.                                          --
26
--                                                                          --
27
-- GNAT was originally developed  by the GNAT team at  New York University. --
28
-- Extensive contributions were provided by Ada Core Technologies Inc.      --
29
--                                                                          --
30
------------------------------------------------------------------------------
31
 
32
pragma Style_Checks (All_Checks);
33
--  Subprogram ordering not enforced in this unit
34
--  (because of some logical groupings).
35
 
36
with Atree;    use Atree;
37
with Csets;    use Csets;
38
with Einfo;    use Einfo;
39
with Fname;    use Fname;
40
with Output;   use Output;
41
with Sinfo;    use Sinfo;
42
with Sinput;   use Sinput;
43
with Stand;    use Stand;
44
with Stringt;  use Stringt;
45
with Tree_IO;  use Tree_IO;
46
with Uname;    use Uname;
47
with Widechar; use Widechar;
48
 
49
package body Lib is
50
 
51
   Switch_Storing_Enabled : Boolean := True;
52
   --  Controlled by Enable_Switch_Storing/Disable_Switch_Storing
53
 
54
   -----------------------
55
   -- Local Subprograms --
56
   -----------------------
57
 
58
   type SEU_Result is (
59
      Yes_Before, -- S1 is in same extended unit as S2 and appears before it
60
      Yes_Same,   -- S1 is in same extended unit as S2, Slocs are the same
61
      Yes_After,  -- S1 is in same extended unit as S2, and appears after it
62
      No);        -- S2 is not in same extended unit as S2
63
 
64
   function Check_Same_Extended_Unit (S1, S2 : Source_Ptr) return SEU_Result;
65
   --  Used by In_Same_Extended_Unit and Earlier_In_Extended_Unit. Returns
66
   --  value as described above.
67
 
68
   function Get_Code_Or_Source_Unit
69
     (S                : Source_Ptr;
70
      Unwind_Instances : Boolean) return Unit_Number_Type;
71
   --  Common code for Get_Code_Unit (get unit of instantiation for location)
72
   --  and Get_Source_Unit (get unit of template for location).
73
 
74
   --------------------------------------------
75
   -- Access Functions for Unit Table Fields --
76
   --------------------------------------------
77
 
78
   function Cunit (U : Unit_Number_Type) return Node_Id is
79
   begin
80
      return Units.Table (U).Cunit;
81
   end Cunit;
82
 
83
   function Cunit_Entity (U : Unit_Number_Type) return Entity_Id is
84
   begin
85
      return Units.Table (U).Cunit_Entity;
86
   end Cunit_Entity;
87
 
88
   function Dependency_Num (U : Unit_Number_Type) return Nat is
89
   begin
90
      return Units.Table (U).Dependency_Num;
91
   end Dependency_Num;
92
 
93
   function Dynamic_Elab (U : Unit_Number_Type) return Boolean is
94
   begin
95
      return Units.Table (U).Dynamic_Elab;
96
   end Dynamic_Elab;
97
 
98
   function Error_Location (U : Unit_Number_Type) return Source_Ptr is
99
   begin
100
      return Units.Table (U).Error_Location;
101
   end Error_Location;
102
 
103
   function Expected_Unit (U : Unit_Number_Type) return Unit_Name_Type is
104
   begin
105
      return Units.Table (U).Expected_Unit;
106
   end Expected_Unit;
107
 
108
   function Fatal_Error (U : Unit_Number_Type) return Boolean is
109
   begin
110
      return Units.Table (U).Fatal_Error;
111
   end Fatal_Error;
112
 
113
   function Generate_Code (U : Unit_Number_Type) return Boolean is
114
   begin
115
      return Units.Table (U).Generate_Code;
116
   end Generate_Code;
117
 
118
   function Has_Allocator (U : Unit_Number_Type) return Boolean is
119
   begin
120
      return Units.Table (U).Has_Allocator;
121
   end Has_Allocator;
122
 
123
   function Has_RACW (U : Unit_Number_Type) return Boolean is
124
   begin
125
      return Units.Table (U).Has_RACW;
126
   end Has_RACW;
127
 
128
   function Is_Compiler_Unit (U : Unit_Number_Type) return Boolean is
129
   begin
130
      return Units.Table (U).Is_Compiler_Unit;
131
   end Is_Compiler_Unit;
132
 
133
   function Ident_String (U : Unit_Number_Type) return Node_Id is
134
   begin
135
      return Units.Table (U).Ident_String;
136
   end Ident_String;
137
 
138
   function Loading (U : Unit_Number_Type) return Boolean is
139
   begin
140
      return Units.Table (U).Loading;
141
   end Loading;
142
 
143
   function Main_CPU (U : Unit_Number_Type) return Int is
144
   begin
145
      return Units.Table (U).Main_CPU;
146
   end Main_CPU;
147
 
148
   function Main_Priority (U : Unit_Number_Type) return Int is
149
   begin
150
      return Units.Table (U).Main_Priority;
151
   end Main_Priority;
152
 
153
   function Munit_Index (U : Unit_Number_Type) return Nat is
154
   begin
155
      return Units.Table (U).Munit_Index;
156
   end Munit_Index;
157
 
158
   function OA_Setting (U : Unit_Number_Type) return Character is
159
   begin
160
      return Units.Table (U).OA_Setting;
161
   end OA_Setting;
162
 
163
   function Source_Index (U : Unit_Number_Type) return Source_File_Index is
164
   begin
165
      return Units.Table (U).Source_Index;
166
   end Source_Index;
167
 
168
   function Unit_File_Name (U : Unit_Number_Type) return File_Name_Type is
169
   begin
170
      return Units.Table (U).Unit_File_Name;
171
   end Unit_File_Name;
172
 
173
   function Unit_Name (U : Unit_Number_Type) return Unit_Name_Type is
174
   begin
175
      return Units.Table (U).Unit_Name;
176
   end Unit_Name;
177
 
178
   ------------------------------------------
179
   -- Subprograms to Set Unit Table Fields --
180
   ------------------------------------------
181
 
182
   procedure Set_Cunit (U : Unit_Number_Type; N : Node_Id) is
183
   begin
184
      Units.Table (U).Cunit := N;
185
   end Set_Cunit;
186
 
187
   procedure Set_Cunit_Entity (U : Unit_Number_Type; E : Entity_Id) is
188
   begin
189
      Units.Table (U).Cunit_Entity := E;
190
      Set_Is_Compilation_Unit (E);
191
   end Set_Cunit_Entity;
192
 
193
   procedure Set_Dynamic_Elab (U : Unit_Number_Type; B : Boolean := True) is
194
   begin
195
      Units.Table (U).Dynamic_Elab := B;
196
   end Set_Dynamic_Elab;
197
 
198
   procedure Set_Error_Location (U : Unit_Number_Type; W : Source_Ptr) is
199
   begin
200
      Units.Table (U).Error_Location := W;
201
   end Set_Error_Location;
202
 
203
   procedure Set_Fatal_Error (U : Unit_Number_Type; B : Boolean := True) is
204
   begin
205
      Units.Table (U).Fatal_Error := B;
206
   end Set_Fatal_Error;
207
 
208
   procedure Set_Generate_Code (U : Unit_Number_Type; B : Boolean := True) is
209
   begin
210
      Units.Table (U).Generate_Code := B;
211
   end Set_Generate_Code;
212
 
213
   procedure Set_Has_Allocator (U : Unit_Number_Type; B : Boolean := True) is
214
   begin
215
      Units.Table (U).Has_Allocator := B;
216
   end Set_Has_Allocator;
217
 
218
   procedure Set_Has_RACW (U : Unit_Number_Type; B : Boolean := True) is
219
   begin
220
      Units.Table (U).Has_RACW := B;
221
   end Set_Has_RACW;
222
 
223
   procedure Set_Is_Compiler_Unit
224
     (U : Unit_Number_Type;
225
      B : Boolean := True)
226
   is
227
   begin
228
      Units.Table (U).Is_Compiler_Unit := B;
229
   end Set_Is_Compiler_Unit;
230
 
231
   procedure Set_Ident_String (U : Unit_Number_Type; N : Node_Id) is
232
   begin
233
      Units.Table (U).Ident_String := N;
234
   end Set_Ident_String;
235
 
236
   procedure Set_Loading (U : Unit_Number_Type; B : Boolean := True) is
237
   begin
238
      Units.Table (U).Loading := B;
239
   end Set_Loading;
240
 
241
   procedure Set_Main_CPU (U : Unit_Number_Type; P : Int) is
242
   begin
243
      Units.Table (U).Main_CPU := P;
244
   end Set_Main_CPU;
245
 
246
   procedure Set_Main_Priority (U : Unit_Number_Type; P : Int) is
247
   begin
248
      Units.Table (U).Main_Priority := P;
249
   end Set_Main_Priority;
250
 
251
   procedure Set_OA_Setting (U : Unit_Number_Type; C : Character) is
252
   begin
253
      Units.Table (U).OA_Setting := C;
254
   end Set_OA_Setting;
255
 
256
   procedure Set_Unit_Name (U : Unit_Number_Type; N : Unit_Name_Type) is
257
   begin
258
      Units.Table (U).Unit_Name := N;
259
   end Set_Unit_Name;
260
 
261
   ------------------------------
262
   -- Check_Same_Extended_Unit --
263
   ------------------------------
264
 
265
   function Check_Same_Extended_Unit (S1, S2 : Source_Ptr) return SEU_Result is
266
      Sloc1  : Source_Ptr;
267
      Sloc2  : Source_Ptr;
268
      Sind1  : Source_File_Index;
269
      Sind2  : Source_File_Index;
270
      Inst1  : Source_Ptr;
271
      Inst2  : Source_Ptr;
272
      Unum1  : Unit_Number_Type;
273
      Unum2  : Unit_Number_Type;
274
      Unit1  : Node_Id;
275
      Unit2  : Node_Id;
276
      Depth1 : Nat;
277
      Depth2 : Nat;
278
 
279
   begin
280
      if S1 = No_Location or else S2 = No_Location then
281
         return No;
282
 
283
      elsif S1 = Standard_Location then
284
         if S2 = Standard_Location then
285
            return Yes_Same;
286
         else
287
            return No;
288
         end if;
289
 
290
      elsif S2 = Standard_Location then
291
         return No;
292
      end if;
293
 
294
      Sloc1 := S1;
295
      Sloc2 := S2;
296
 
297
      Unum1 := Get_Source_Unit (Sloc1);
298
      Unum2 := Get_Source_Unit (Sloc2);
299
 
300
      loop
301
         --  Step 1: Check whether the two locations are in the same source
302
         --  file.
303
 
304
         Sind1 := Get_Source_File_Index (Sloc1);
305
         Sind2 := Get_Source_File_Index (Sloc2);
306
 
307
         if Sind1 = Sind2 then
308
            if Sloc1 < Sloc2 then
309
               return Yes_Before;
310
            elsif Sloc1 > Sloc2 then
311
               return Yes_After;
312
            else
313
               return Yes_Same;
314
            end if;
315
         end if;
316
 
317
         --  Step 2: Check subunits. If a subunit is instantiated, follow the
318
         --  instantiation chain rather than the stub chain.
319
 
320
         Unit1 := Unit (Cunit (Unum1));
321
         Unit2 := Unit (Cunit (Unum2));
322
         Inst1 := Instantiation (Sind1);
323
         Inst2 := Instantiation (Sind2);
324
 
325
         if Nkind (Unit1) = N_Subunit
326
           and then Present (Corresponding_Stub (Unit1))
327
           and then Inst1 = No_Location
328
         then
329
            if Nkind (Unit2) = N_Subunit
330
              and then Present (Corresponding_Stub (Unit2))
331
              and then Inst2 = No_Location
332
            then
333
               --  Both locations refer to subunits which may have a common
334
               --  ancestor. If they do, the deeper subunit must have a longer
335
               --  unit name. Replace the deeper one with its corresponding
336
               --  stub in order to find the nearest ancestor.
337
 
338
               if Length_Of_Name (Unit_Name (Unum1)) <
339
                  Length_Of_Name (Unit_Name (Unum2))
340
               then
341
                  Sloc2 := Sloc (Corresponding_Stub (Unit2));
342
                  Unum2 := Get_Source_Unit (Sloc2);
343
                  goto Continue;
344
 
345
               else
346
                  Sloc1 := Sloc (Corresponding_Stub (Unit1));
347
                  Unum1 := Get_Source_Unit (Sloc1);
348
                  goto Continue;
349
               end if;
350
 
351
            --  Sloc1 in subunit, Sloc2 not
352
 
353
            else
354
               Sloc1 := Sloc (Corresponding_Stub (Unit1));
355
               Unum1 := Get_Source_Unit (Sloc1);
356
               goto Continue;
357
            end if;
358
 
359
         --  Sloc2 in subunit, Sloc1 not
360
 
361
         elsif Nkind (Unit2) = N_Subunit
362
           and then Present (Corresponding_Stub (Unit2))
363
           and then Inst2 = No_Location
364
         then
365
            Sloc2 := Sloc (Corresponding_Stub (Unit2));
366
            Unum2 := Get_Source_Unit (Sloc2);
367
            goto Continue;
368
         end if;
369
 
370
         --  Step 3: Check instances. The two locations may yield a common
371
         --  ancestor.
372
 
373
         if Inst1 /= No_Location then
374
            if Inst2 /= No_Location then
375
 
376
               --  Both locations denote instantiations
377
 
378
               Depth1 := Instantiation_Depth (Sloc1);
379
               Depth2 := Instantiation_Depth (Sloc2);
380
 
381
               if Depth1 < Depth2 then
382
                  Sloc2 := Inst2;
383
                  Unum2 := Get_Source_Unit (Sloc2);
384
                  goto Continue;
385
 
386
               elsif Depth1 > Depth2 then
387
                  Sloc1 := Inst1;
388
                  Unum1 := Get_Source_Unit (Sloc1);
389
                  goto Continue;
390
 
391
               else
392
                  Sloc1 := Inst1;
393
                  Sloc2 := Inst2;
394
                  Unum1 := Get_Source_Unit (Sloc1);
395
                  Unum2 := Get_Source_Unit (Sloc2);
396
                  goto Continue;
397
               end if;
398
 
399
            --  Sloc1 is an instantiation
400
 
401
            else
402
               Sloc1 := Inst1;
403
               Unum1 := Get_Source_Unit (Sloc1);
404
               goto Continue;
405
            end if;
406
 
407
         --  Sloc2 is an instantiation
408
 
409
         elsif Inst2 /= No_Location then
410
            Sloc2 := Inst2;
411
            Unum2 := Get_Source_Unit (Sloc2);
412
            goto Continue;
413
         end if;
414
 
415
         --  Step 4: One location in the spec, the other in the corresponding
416
         --  body of the same unit. The location in the spec is considered
417
         --  earlier.
418
 
419
         if Nkind (Unit1) = N_Subprogram_Body
420
              or else
421
            Nkind (Unit1) = N_Package_Body
422
         then
423
            if Library_Unit (Cunit (Unum1)) = Cunit (Unum2) then
424
               return Yes_After;
425
            end if;
426
 
427
         elsif Nkind (Unit2) = N_Subprogram_Body
428
                 or else
429
               Nkind (Unit2) = N_Package_Body
430
         then
431
            if Library_Unit (Cunit (Unum2)) = Cunit (Unum1) then
432
               return Yes_Before;
433
            end if;
434
         end if;
435
 
436
         --  At this point it is certain that the two locations denote two
437
         --  entirely separate units.
438
 
439
         return No;
440
 
441
         <<Continue>>
442
            null;
443
      end loop;
444
   end Check_Same_Extended_Unit;
445
 
446
   -------------------------------
447
   -- Compilation_Switches_Last --
448
   -------------------------------
449
 
450
   function Compilation_Switches_Last return Nat is
451
   begin
452
      return Compilation_Switches.Last;
453
   end Compilation_Switches_Last;
454
 
455
   ---------------------------
456
   -- Enable_Switch_Storing --
457
   ---------------------------
458
 
459
   procedure Enable_Switch_Storing is
460
   begin
461
      Switch_Storing_Enabled := True;
462
   end Enable_Switch_Storing;
463
 
464
   ----------------------------
465
   -- Disable_Switch_Storing --
466
   ----------------------------
467
 
468
   procedure Disable_Switch_Storing is
469
   begin
470
      Switch_Storing_Enabled := False;
471
   end Disable_Switch_Storing;
472
 
473
   ------------------------------
474
   -- Earlier_In_Extended_Unit --
475
   ------------------------------
476
 
477
   function Earlier_In_Extended_Unit (S1, S2 : Source_Ptr) return Boolean is
478
   begin
479
      return Check_Same_Extended_Unit (S1, S2) = Yes_Before;
480
   end Earlier_In_Extended_Unit;
481
 
482
   -----------------------
483
   -- Exact_Source_Name --
484
   -----------------------
485
 
486
   function Exact_Source_Name (Loc : Source_Ptr) return String is
487
      U    : constant Unit_Number_Type  := Get_Source_Unit (Loc);
488
      Buf  : constant Source_Buffer_Ptr := Source_Text (Source_Index (U));
489
      Orig : constant Source_Ptr        := Original_Location (Loc);
490
      P    : Source_Ptr;
491
 
492
      WC   : Char_Code;
493
      Err  : Boolean;
494
      pragma Warnings (Off, WC);
495
      pragma Warnings (Off, Err);
496
 
497
   begin
498
      --  Entity is character literal
499
 
500
      if Buf (Orig) = ''' then
501
         return String (Buf (Orig .. Orig + 2));
502
 
503
      --  Entity is operator symbol
504
 
505
      elsif Buf (Orig) = '"' or else Buf (Orig) = '%' then
506
         P := Orig;
507
 
508
         loop
509
            P := P + 1;
510
            exit when Buf (P) = Buf (Orig);
511
         end loop;
512
 
513
         return String (Buf (Orig .. P));
514
 
515
      --  Entity is identifier
516
 
517
      else
518
         P := Orig;
519
 
520
         loop
521
            if Is_Start_Of_Wide_Char (Buf, P) then
522
               Scan_Wide (Buf, P, WC, Err);
523
            elsif not Identifier_Char (Buf (P)) then
524
               exit;
525
            else
526
               P := P + 1;
527
            end if;
528
         end loop;
529
 
530
         --  Write out the identifier by copying the exact source characters
531
         --  used in its declaration. Note that this means wide characters will
532
         --  be in their original encoded form.
533
 
534
         return String (Buf (Orig .. P - 1));
535
      end if;
536
   end Exact_Source_Name;
537
 
538
   ----------------------------
539
   -- Entity_Is_In_Main_Unit --
540
   ----------------------------
541
 
542
   function Entity_Is_In_Main_Unit (E : Entity_Id) return Boolean is
543
      S : Entity_Id;
544
 
545
   begin
546
      S := Scope (E);
547
 
548
      while S /= Standard_Standard loop
549
         if S = Main_Unit_Entity then
550
            return True;
551
         elsif Ekind (S) = E_Package and then Is_Child_Unit (S) then
552
            return False;
553
         else
554
            S := Scope (S);
555
         end if;
556
      end loop;
557
 
558
      return False;
559
   end Entity_Is_In_Main_Unit;
560
 
561
   --------------------------
562
   -- Generic_May_Lack_ALI --
563
   --------------------------
564
 
565
   function Generic_May_Lack_ALI (Sfile : File_Name_Type) return Boolean is
566
   begin
567
      --  We allow internal generic units to be used without having a
568
      --  corresponding ALI files to help bootstrapping with older compilers
569
      --  that did not support generating ALIs for such generics. It is safe
570
      --  to do so because the only thing the generated code would contain
571
      --  is the elaboration boolean, and we are careful to elaborate all
572
      --  predefined units first anyway.
573
 
574
      return Is_Internal_File_Name
575
               (Fname              => Sfile,
576
                Renamings_Included => True);
577
   end Generic_May_Lack_ALI;
578
 
579
   -----------------------------
580
   -- Get_Code_Or_Source_Unit --
581
   -----------------------------
582
 
583
   function Get_Code_Or_Source_Unit
584
     (S                : Source_Ptr;
585
      Unwind_Instances : Boolean) return Unit_Number_Type
586
   is
587
   begin
588
      --  Search table unless we have No_Location, which can happen if the
589
      --  relevant location has not been set yet. Happens for example when
590
      --  we obtain Sloc (Cunit (Main_Unit)) before it is set.
591
 
592
      if S /= No_Location then
593
         declare
594
            Source_File : Source_File_Index;
595
            Source_Unit : Unit_Number_Type;
596
 
597
         begin
598
            Source_File := Get_Source_File_Index (S);
599
 
600
            if Unwind_Instances then
601
               while Template (Source_File) /= No_Source_File loop
602
                  Source_File := Template (Source_File);
603
               end loop;
604
            end if;
605
 
606
            Source_Unit := Unit (Source_File);
607
 
608
            if Source_Unit /= No_Unit then
609
               return Source_Unit;
610
            end if;
611
         end;
612
      end if;
613
 
614
      --  If S was No_Location, or was not in the table, we must be in the main
615
      --  source unit (and the value has not been placed in the table yet),
616
      --  or in one of the configuration pragma files.
617
 
618
      return Main_Unit;
619
   end Get_Code_Or_Source_Unit;
620
 
621
   -------------------
622
   -- Get_Code_Unit --
623
   -------------------
624
 
625
   function Get_Code_Unit (S : Source_Ptr) return Unit_Number_Type is
626
   begin
627
      return Get_Code_Or_Source_Unit (Top_Level_Location (S),
628
        Unwind_Instances => False);
629
   end Get_Code_Unit;
630
 
631
   function Get_Code_Unit (N : Node_Or_Entity_Id) return Unit_Number_Type is
632
   begin
633
      return Get_Code_Unit (Sloc (N));
634
   end Get_Code_Unit;
635
 
636
   ----------------------------
637
   -- Get_Compilation_Switch --
638
   ----------------------------
639
 
640
   function Get_Compilation_Switch (N : Pos) return String_Ptr is
641
   begin
642
      if N <= Compilation_Switches.Last then
643
         return Compilation_Switches.Table (N);
644
 
645
      else
646
         return null;
647
      end if;
648
   end Get_Compilation_Switch;
649
 
650
   ----------------------------------
651
   -- Get_Cunit_Entity_Unit_Number --
652
   ----------------------------------
653
 
654
   function Get_Cunit_Entity_Unit_Number
655
     (E : Entity_Id) return Unit_Number_Type
656
   is
657
   begin
658
      for U in Units.First .. Units.Last loop
659
         if Cunit_Entity (U) = E then
660
            return U;
661
         end if;
662
      end loop;
663
 
664
      --  If not in the table, must be the main source unit, and we just
665
      --  have not got it put into the table yet.
666
 
667
      return Main_Unit;
668
   end Get_Cunit_Entity_Unit_Number;
669
 
670
   ---------------------------
671
   -- Get_Cunit_Unit_Number --
672
   ---------------------------
673
 
674
   function Get_Cunit_Unit_Number (N : Node_Id) return Unit_Number_Type is
675
   begin
676
      for U in Units.First .. Units.Last loop
677
         if Cunit (U) = N then
678
            return U;
679
         end if;
680
      end loop;
681
 
682
      --  If not in the table, must be a spec created for a main unit that is a
683
      --  child subprogram body which we have not inserted into the table yet.
684
 
685
      if N = Library_Unit (Cunit (Main_Unit)) then
686
         return Main_Unit;
687
 
688
      --  If it is anything else, something is seriously wrong, and we really
689
      --  don't want to proceed, even if assertions are off, so we explicitly
690
      --  raise an exception in this case to terminate compilation.
691
 
692
      else
693
         raise Program_Error;
694
      end if;
695
   end Get_Cunit_Unit_Number;
696
 
697
   ---------------------
698
   -- Get_Source_Unit --
699
   ---------------------
700
 
701
   function Get_Source_Unit (S : Source_Ptr) return Unit_Number_Type is
702
   begin
703
      return Get_Code_Or_Source_Unit (S, Unwind_Instances => True);
704
   end Get_Source_Unit;
705
 
706
   function Get_Source_Unit (N : Node_Or_Entity_Id) return Unit_Number_Type is
707
   begin
708
      return Get_Source_Unit (Sloc (N));
709
   end Get_Source_Unit;
710
 
711
   --------------------------------
712
   -- In_Extended_Main_Code_Unit --
713
   --------------------------------
714
 
715
   function In_Extended_Main_Code_Unit
716
     (N : Node_Or_Entity_Id) return Boolean
717
   is
718
   begin
719
      if Sloc (N) = Standard_Location then
720
         return True;
721
 
722
      elsif Sloc (N) = No_Location then
723
         return False;
724
 
725
      --  Special case Itypes to test the Sloc of the associated node. The
726
      --  reason we do this is for possible calls from gigi after -gnatD
727
      --  processing is complete in sprint. This processing updates the
728
      --  sloc fields of all nodes in the tree, but itypes are not in the
729
      --  tree so their slocs do not get updated.
730
 
731
      elsif Nkind (N) = N_Defining_Identifier
732
        and then Is_Itype (N)
733
      then
734
         return In_Extended_Main_Code_Unit (Associated_Node_For_Itype (N));
735
 
736
      --  Otherwise see if we are in the main unit
737
 
738
      elsif Get_Code_Unit (Sloc (N)) = Get_Code_Unit (Cunit (Main_Unit)) then
739
         return True;
740
 
741
      --  Node may be in spec (or subunit etc) of main unit
742
 
743
      else
744
         return
745
           In_Same_Extended_Unit (N, Cunit (Main_Unit));
746
      end if;
747
   end In_Extended_Main_Code_Unit;
748
 
749
   function In_Extended_Main_Code_Unit (Loc : Source_Ptr) return Boolean is
750
   begin
751
      if Loc = Standard_Location then
752
         return True;
753
 
754
      elsif Loc = No_Location then
755
         return False;
756
 
757
      --  Otherwise see if we are in the main unit
758
 
759
      elsif Get_Code_Unit (Loc) = Get_Code_Unit (Cunit (Main_Unit)) then
760
         return True;
761
 
762
      --  Location may be in spec (or subunit etc) of main unit
763
 
764
      else
765
         return
766
           In_Same_Extended_Unit (Loc, Sloc (Cunit (Main_Unit)));
767
      end if;
768
   end In_Extended_Main_Code_Unit;
769
 
770
   ----------------------------------
771
   -- In_Extended_Main_Source_Unit --
772
   ----------------------------------
773
 
774
   function In_Extended_Main_Source_Unit
775
     (N : Node_Or_Entity_Id) return Boolean
776
   is
777
      Nloc : constant Source_Ptr := Sloc (N);
778
      Mloc : constant Source_Ptr := Sloc (Cunit (Main_Unit));
779
 
780
   begin
781
      --  If parsing, then use the global flag to indicate result
782
 
783
      if Compiler_State = Parsing then
784
         return Parsing_Main_Extended_Source;
785
 
786
      --  Special value cases
787
 
788
      elsif Nloc = Standard_Location then
789
         return True;
790
 
791
      elsif Nloc = No_Location then
792
         return False;
793
 
794
      --  Special case Itypes to test the Sloc of the associated node. The
795
      --  reason we do this is for possible calls from gigi after -gnatD
796
      --  processing is complete in sprint. This processing updates the
797
      --  sloc fields of all nodes in the tree, but itypes are not in the
798
      --  tree so their slocs do not get updated.
799
 
800
      elsif Nkind (N) = N_Defining_Identifier
801
        and then Is_Itype (N)
802
      then
803
         return In_Extended_Main_Source_Unit (Associated_Node_For_Itype (N));
804
 
805
      --  Otherwise compare original locations to see if in same unit
806
 
807
      else
808
         return
809
           In_Same_Extended_Unit
810
             (Original_Location (Nloc), Original_Location (Mloc));
811
      end if;
812
   end In_Extended_Main_Source_Unit;
813
 
814
   function In_Extended_Main_Source_Unit
815
     (Loc : Source_Ptr) return Boolean
816
   is
817
      Mloc : constant Source_Ptr := Sloc (Cunit (Main_Unit));
818
 
819
   begin
820
      --  If parsing, then use the global flag to indicate result
821
 
822
      if Compiler_State = Parsing then
823
         return Parsing_Main_Extended_Source;
824
 
825
      --  Special value cases
826
 
827
      elsif Loc = Standard_Location then
828
         return True;
829
 
830
      elsif Loc = No_Location then
831
         return False;
832
 
833
      --  Otherwise compare original locations to see if in same unit
834
 
835
      else
836
         return
837
           In_Same_Extended_Unit
838
             (Original_Location (Loc), Original_Location (Mloc));
839
      end if;
840
   end In_Extended_Main_Source_Unit;
841
 
842
   ------------------------
843
   -- In_Predefined_Unit --
844
   ------------------------
845
 
846
   function In_Predefined_Unit (N : Node_Or_Entity_Id) return Boolean is
847
   begin
848
      return In_Predefined_Unit (Sloc (N));
849
   end In_Predefined_Unit;
850
 
851
   function In_Predefined_Unit (S : Source_Ptr) return Boolean is
852
      Unit : constant Unit_Number_Type := Get_Source_Unit (S);
853
      File : constant File_Name_Type   := Unit_File_Name (Unit);
854
   begin
855
      return Is_Predefined_File_Name (File);
856
   end In_Predefined_Unit;
857
 
858
   -----------------------
859
   -- In_Same_Code_Unit --
860
   -----------------------
861
 
862
   function In_Same_Code_Unit (N1, N2 : Node_Or_Entity_Id) return Boolean is
863
      S1 : constant Source_Ptr := Sloc (N1);
864
      S2 : constant Source_Ptr := Sloc (N2);
865
 
866
   begin
867
      if S1 = No_Location or else S2 = No_Location then
868
         return False;
869
 
870
      elsif S1 = Standard_Location then
871
         return S2 = Standard_Location;
872
 
873
      elsif S2 = Standard_Location then
874
         return False;
875
      end if;
876
 
877
      return Get_Code_Unit (N1) = Get_Code_Unit (N2);
878
   end In_Same_Code_Unit;
879
 
880
   ---------------------------
881
   -- In_Same_Extended_Unit --
882
   ---------------------------
883
 
884
   function In_Same_Extended_Unit
885
     (N1, N2 : Node_Or_Entity_Id) return Boolean
886
   is
887
   begin
888
      return Check_Same_Extended_Unit (Sloc (N1), Sloc (N2)) /= No;
889
   end In_Same_Extended_Unit;
890
 
891
   function In_Same_Extended_Unit (S1, S2 : Source_Ptr) return Boolean is
892
   begin
893
      return Check_Same_Extended_Unit (S1, S2) /= No;
894
   end In_Same_Extended_Unit;
895
 
896
   -------------------------
897
   -- In_Same_Source_Unit --
898
   -------------------------
899
 
900
   function In_Same_Source_Unit (N1, N2 : Node_Or_Entity_Id) return Boolean is
901
      S1 : constant Source_Ptr := Sloc (N1);
902
      S2 : constant Source_Ptr := Sloc (N2);
903
 
904
   begin
905
      if S1 = No_Location or else S2 = No_Location then
906
         return False;
907
 
908
      elsif S1 = Standard_Location then
909
         return S2 = Standard_Location;
910
 
911
      elsif S2 = Standard_Location then
912
         return False;
913
      end if;
914
 
915
      return Get_Source_Unit (N1) = Get_Source_Unit (N2);
916
   end In_Same_Source_Unit;
917
 
918
   -----------------------------
919
   -- Increment_Serial_Number --
920
   -----------------------------
921
 
922
   function Increment_Serial_Number return Nat is
923
      TSN : Int renames Units.Table (Current_Sem_Unit).Serial_Number;
924
   begin
925
      TSN := TSN + 1;
926
      return TSN;
927
   end Increment_Serial_Number;
928
 
929
   ----------------
930
   -- Initialize --
931
   ----------------
932
 
933
   procedure Initialize is
934
   begin
935
      Linker_Option_Lines.Init;
936
      Notes.Init;
937
      Load_Stack.Init;
938
      Units.Init;
939
      Compilation_Switches.Init;
940
   end Initialize;
941
 
942
   ---------------
943
   -- Is_Loaded --
944
   ---------------
945
 
946
   function Is_Loaded (Uname : Unit_Name_Type) return Boolean is
947
   begin
948
      for Unum in Units.First .. Units.Last loop
949
         if Uname = Unit_Name (Unum) then
950
            return True;
951
         end if;
952
      end loop;
953
 
954
      return False;
955
   end Is_Loaded;
956
 
957
   ---------------
958
   -- Last_Unit --
959
   ---------------
960
 
961
   function Last_Unit return Unit_Number_Type is
962
   begin
963
      return Units.Last;
964
   end Last_Unit;
965
 
966
   ----------
967
   -- List --
968
   ----------
969
 
970
   procedure List (File_Names_Only : Boolean := False) is separate;
971
 
972
   ----------
973
   -- Lock --
974
   ----------
975
 
976
   procedure Lock is
977
   begin
978
      Linker_Option_Lines.Locked := True;
979
      Load_Stack.Locked := True;
980
      Units.Locked := True;
981
      Linker_Option_Lines.Release;
982
      Load_Stack.Release;
983
      Units.Release;
984
   end Lock;
985
 
986
   ---------------
987
   -- Num_Units --
988
   ---------------
989
 
990
   function Num_Units return Nat is
991
   begin
992
      return Int (Units.Last) - Int (Main_Unit) + 1;
993
   end Num_Units;
994
 
995
   -----------------
996
   -- Remove_Unit --
997
   -----------------
998
 
999
   procedure Remove_Unit (U : Unit_Number_Type) is
1000
   begin
1001
      if U = Units.Last then
1002
         Units.Decrement_Last;
1003
      end if;
1004
   end Remove_Unit;
1005
 
1006
   ----------------------------------
1007
   -- Replace_Linker_Option_String --
1008
   ----------------------------------
1009
 
1010
   procedure Replace_Linker_Option_String
1011
     (S : String_Id; Match_String : String)
1012
   is
1013
   begin
1014
      if Match_String'Length > 0 then
1015
         for J in 1 .. Linker_Option_Lines.Last loop
1016
            String_To_Name_Buffer (Linker_Option_Lines.Table (J).Option);
1017
 
1018
            if Match_String = Name_Buffer (1 .. Match_String'Length) then
1019
               Linker_Option_Lines.Table (J).Option := S;
1020
               return;
1021
            end if;
1022
         end loop;
1023
      end if;
1024
 
1025
      Store_Linker_Option_String (S);
1026
   end Replace_Linker_Option_String;
1027
 
1028
   ----------
1029
   -- Sort --
1030
   ----------
1031
 
1032
   procedure Sort (Tbl : in out Unit_Ref_Table) is separate;
1033
 
1034
   ------------------------------
1035
   -- Store_Compilation_Switch --
1036
   ------------------------------
1037
 
1038
   procedure Store_Compilation_Switch (Switch : String) is
1039
   begin
1040
      if Switch_Storing_Enabled then
1041
         Compilation_Switches.Increment_Last;
1042
         Compilation_Switches.Table (Compilation_Switches.Last) :=
1043
           new String'(Switch);
1044
 
1045
         --  Fix up --RTS flag which has been transformed by the gcc driver
1046
         --  into -fRTS
1047
 
1048
         if Switch'Last >= Switch'First + 4
1049
           and then Switch (Switch'First .. Switch'First + 4) = "-fRTS"
1050
         then
1051
            Compilation_Switches.Table
1052
              (Compilation_Switches.Last) (Switch'First + 1) := '-';
1053
         end if;
1054
      end if;
1055
   end Store_Compilation_Switch;
1056
 
1057
   --------------------------------
1058
   -- Store_Linker_Option_String --
1059
   --------------------------------
1060
 
1061
   procedure Store_Linker_Option_String (S : String_Id) is
1062
   begin
1063
      Linker_Option_Lines.Append ((Option => S, Unit => Current_Sem_Unit));
1064
   end Store_Linker_Option_String;
1065
 
1066
   ----------------
1067
   -- Store_Note --
1068
   ----------------
1069
 
1070
   procedure Store_Note (N : Node_Id) is
1071
   begin
1072
      Notes.Append ((Pragma_Node => N, Unit => Current_Sem_Unit));
1073
   end Store_Note;
1074
 
1075
   -------------------------------
1076
   -- Synchronize_Serial_Number --
1077
   -------------------------------
1078
 
1079
   procedure Synchronize_Serial_Number is
1080
      TSN : Int renames Units.Table (Current_Sem_Unit).Serial_Number;
1081
   begin
1082
      TSN := TSN + 1;
1083
   end Synchronize_Serial_Number;
1084
 
1085
   ---------------
1086
   -- Tree_Read --
1087
   ---------------
1088
 
1089
   procedure Tree_Read is
1090
      N : Nat;
1091
      S : String_Ptr;
1092
 
1093
   begin
1094
      Units.Tree_Read;
1095
 
1096
      --  Read Compilation_Switches table. First release the memory occupied
1097
      --  by the previously loaded switches.
1098
 
1099
      for J in Compilation_Switches.First .. Compilation_Switches.Last loop
1100
         Free (Compilation_Switches.Table (J));
1101
      end loop;
1102
 
1103
      Tree_Read_Int (N);
1104
      Compilation_Switches.Set_Last (N);
1105
 
1106
      for J in 1 .. N loop
1107
         Tree_Read_Str (S);
1108
         Compilation_Switches.Table (J) := S;
1109
      end loop;
1110
   end Tree_Read;
1111
 
1112
   ----------------
1113
   -- Tree_Write --
1114
   ----------------
1115
 
1116
   procedure Tree_Write is
1117
   begin
1118
      Units.Tree_Write;
1119
 
1120
      --  Write Compilation_Switches table
1121
 
1122
      Tree_Write_Int (Compilation_Switches.Last);
1123
 
1124
      for J in 1 .. Compilation_Switches.Last loop
1125
         Tree_Write_Str (Compilation_Switches.Table (J));
1126
      end loop;
1127
   end Tree_Write;
1128
 
1129
   ------------
1130
   -- Unlock --
1131
   ------------
1132
 
1133
   procedure Unlock is
1134
   begin
1135
      Linker_Option_Lines.Locked := False;
1136
      Load_Stack.Locked := False;
1137
      Units.Locked := False;
1138
   end Unlock;
1139
 
1140
   -----------------
1141
   -- Version_Get --
1142
   -----------------
1143
 
1144
   function Version_Get (U : Unit_Number_Type) return Word_Hex_String is
1145
   begin
1146
      return Get_Hex_String (Units.Table (U).Version);
1147
   end Version_Get;
1148
 
1149
   ------------------------
1150
   -- Version_Referenced --
1151
   ------------------------
1152
 
1153
   procedure Version_Referenced (S : String_Id) is
1154
   begin
1155
      Version_Ref.Append (S);
1156
   end Version_Referenced;
1157
 
1158
end Lib;

powered by: WebSVN 2.1.0

© copyright 1999-2024 OpenCores.org, equivalent to Oliscience, all rights reserved. OpenCores®, registered trademark.