OpenCores
URL https://opencores.org/ocsvn/openrisc/openrisc/trunk

Subversion Repositories openrisc

[/] [openrisc/] [trunk/] [gnu-dev/] [or1k-gcc/] [gcc/] [ada/] [par-load.adb] - Blame information for rev 729

Go to most recent revision | Details | Compare with Previous | View Log

Line No. Rev Author Line
1 706 jeremybenn
------------------------------------------------------------------------------
2
--                                                                          --
3
--                         GNAT COMPILER COMPONENTS                         --
4
--                                                                          --
5
--                             P A R . L O A D                              --
6
--                                                                          --
7
--                                 B o d y                                  --
8
--                                                                          --
9
--          Copyright (C) 1992-2010, Free Software Foundation, Inc.         --
10
--                                                                          --
11
-- GNAT is free software;  you can  redistribute it  and/or modify it under --
12
-- terms of the  GNU General Public License as published  by the Free Soft- --
13
-- ware  Foundation;  either version 3,  or (at your option) any later ver- --
14
-- sion.  GNAT is distributed in the hope that it will be useful, but WITH- --
15
-- OUT ANY WARRANTY;  without even the  implied warranty of MERCHANTABILITY --
16
-- or FITNESS FOR A PARTICULAR PURPOSE.  See the GNU General Public License --
17
-- for  more details.  You should have  received  a copy of the GNU General --
18
-- Public License  distributed with GNAT; see file COPYING3.  If not, go to --
19
-- http://www.gnu.org/licenses for a complete copy of the license.          --
20
--                                                                          --
21
-- GNAT was originally developed  by the GNAT team at  New York University. --
22
-- Extensive contributions were provided by Ada Core Technologies Inc.      --
23
--                                                                          --
24
------------------------------------------------------------------------------
25
 
26
--  The Par.Load procedure loads all units that are definitely required before
27
--  it makes any sense at all to proceed with semantic analysis, including
28
--  with'ed units, corresponding specs for bodies, parents of child specs,
29
--  and parents of subunits. All these units are loaded and pointers installed
30
--  in the tree as described in the spec of package Lib.
31
 
32
with Fname.UF; use Fname.UF;
33
with Lib.Load; use Lib.Load;
34
with Namet.Sp; use Namet.Sp;
35
with Uname;    use Uname;
36
with Osint;    use Osint;
37
with Sinput.L; use Sinput.L;
38
with Stylesw;  use Stylesw;
39
with Validsw;  use Validsw;
40
 
41
with GNAT.Spelling_Checker; use GNAT.Spelling_Checker;
42
 
43
separate (Par)
44
procedure Load is
45
 
46
   File_Name : File_Name_Type;
47
   --  Name of file for current unit, derived from unit name
48
 
49
   Cur_Unum : constant Unit_Number_Type := Current_Source_Unit;
50
   --  Unit number of unit that we just finished parsing. Note that we need
51
   --  to capture this, because Source_Unit will change as we parse new
52
   --  source files in the multiple main source file case.
53
 
54
   Curunit : constant Node_Id := Cunit (Cur_Unum);
55
   --  Compilation unit node for current compilation unit
56
 
57
   Loc : Source_Ptr := Sloc (Curunit);
58
   --  Source location for compilation unit node
59
 
60
   Save_Style_Check  : Boolean;
61
   Save_Style_Checks : Style_Check_Options;
62
   --  Save style check so it can be restored later
63
 
64
   Save_Validity_Check  : Boolean;
65
   Save_Validity_Checks : Validity_Check_Options;
66
   --  Save validity check so it can be restored later
67
 
68
   With_Cunit : Node_Id;
69
   --  Compilation unit node for withed unit
70
 
71
   Context_Node : Node_Id;
72
   --  Next node in context items list
73
 
74
   With_Node : Node_Id;
75
   --  N_With_Clause node
76
 
77
   Spec_Name : Unit_Name_Type;
78
   --  Unit name of required spec
79
 
80
   Body_Name : Unit_Name_Type;
81
   --  Unit name of corresponding body
82
 
83
   Unum : Unit_Number_Type;
84
   --  Unit number of loaded unit
85
 
86
   Limited_With_Found : Boolean := False;
87
   --  We load the context items in two rounds: the first round handles normal
88
   --  withed units and the second round handles Ada 2005 limited-withed units.
89
   --  This is required to allow the low-level circuitry that detects circular
90
   --  dependencies of units the correct notification of errors (see comment
91
   --  bellow). This variable is used to indicate that the second round is
92
   --  required.
93
 
94
   function Same_File_Name_Except_For_Case
95
     (Expected_File_Name : File_Name_Type;
96
      Actual_File_Name   : File_Name_Type) return Boolean;
97
   --  Given an actual file name and an expected file name (the latter being
98
   --  derived from the unit name), determine if they are the same except for
99
   --  possibly different casing of letters.
100
 
101
   ------------------------------------
102
   -- Same_File_Name_Except_For_Case --
103
   ------------------------------------
104
 
105
   function Same_File_Name_Except_For_Case
106
     (Expected_File_Name : File_Name_Type;
107
      Actual_File_Name   : File_Name_Type) return Boolean
108
   is
109
   begin
110
      Get_Name_String (Actual_File_Name);
111
      Canonical_Case_File_Name (Name_Buffer (1 .. Name_Len));
112
 
113
      declare
114
         Lower_Case_Actual_File_Name : String (1 .. Name_Len);
115
 
116
      begin
117
         Lower_Case_Actual_File_Name := Name_Buffer (1 .. Name_Len);
118
         Get_Name_String (Expected_File_Name);
119
         Canonical_Case_File_Name (Name_Buffer (1 .. Name_Len));
120
         return Lower_Case_Actual_File_Name = Name_Buffer (1 .. Name_Len);
121
      end;
122
 
123
   end Same_File_Name_Except_For_Case;
124
 
125
--  Start of processing for Load
126
 
127
begin
128
   --  Don't do any loads if we already had a fatal error
129
 
130
   if Fatal_Error (Cur_Unum) then
131
      return;
132
   end if;
133
 
134
   Save_Style_Check_Options (Save_Style_Checks);
135
   Save_Style_Check := Opt.Style_Check;
136
 
137
   Save_Validity_Check_Options (Save_Validity_Checks);
138
   Save_Validity_Check := Opt.Validity_Checks_On;
139
 
140
   --  If main unit, set Main_Unit_Entity (this will get overwritten if
141
   --  the main unit has a separate spec, that happens later on in Load)
142
 
143
   if Cur_Unum = Main_Unit then
144
      Main_Unit_Entity := Cunit_Entity (Main_Unit);
145
   end if;
146
 
147
   --  If we have no unit name, things are seriously messed up by previous
148
   --  errors, and we should not try to continue compilation.
149
 
150
   if Unit_Name (Cur_Unum) = No_Unit_Name then
151
      raise Unrecoverable_Error;
152
   end if;
153
 
154
   --  Next step, make sure that the unit name matches the file name
155
   --  and issue a warning message if not. We only output this for the
156
   --  main unit, since for other units it is more serious and is
157
   --  caught in a separate test below. We also inhibit the message in
158
   --  multiple unit per file mode, because in this case the relation
159
   --  between file name and unit name is broken.
160
 
161
   File_Name :=
162
     Get_File_Name
163
       (Unit_Name (Cur_Unum),
164
        Subunit => Nkind (Unit (Cunit (Cur_Unum))) = N_Subunit);
165
 
166
   if Cur_Unum = Main_Unit
167
     and then Multiple_Unit_Index = 0
168
     and then File_Name /= Unit_File_Name (Cur_Unum)
169
     and then (File_Names_Case_Sensitive
170
                or not Same_File_Name_Except_For_Case
171
                         (File_Name, Unit_File_Name (Cur_Unum)))
172
   then
173
      Error_Msg_File_1 := File_Name;
174
      Error_Msg
175
        ("?file name does not match unit name, should be{", Sloc (Curunit));
176
   end if;
177
 
178
   --  For units other than the main unit, the expected unit name is set and
179
   --  must be the same as the actual unit name, or we are in big trouble, and
180
   --  abandon the compilation since there are situations where this really
181
   --  gets us into bad trouble (e.g. some subunit situations).
182
 
183
   if Cur_Unum /= Main_Unit
184
     and then Expected_Unit (Cur_Unum) /= Unit_Name (Cur_Unum)
185
   then
186
      Loc := Error_Location (Cur_Unum);
187
      Error_Msg_File_1 := Unit_File_Name (Cur_Unum);
188
      Get_Name_String (Error_Msg_File_1);
189
 
190
      --  Check for predefined file case
191
 
192
      if Name_Len > 1
193
        and then Name_Buffer (2) = '-'
194
        and then (Name_Buffer (1) = 'a'
195
                    or else
196
                  Name_Buffer (1) = 's'
197
                    or else
198
                  Name_Buffer (1) = 'i'
199
                    or else
200
                  Name_Buffer (1) = 'g')
201
      then
202
         declare
203
            Expect_Name : constant Unit_Name_Type := Expected_Unit (Cur_Unum);
204
            Actual_Name : constant Unit_Name_Type := Unit_Name (Cur_Unum);
205
 
206
         begin
207
            Error_Msg_Unit_1 := Expect_Name;
208
            Error_Msg -- CODEFIX
209
              ("$$ is not a predefined library unit!", Loc);
210
 
211
            --  In the predefined file case, we know the user did not
212
            --  construct their own package, but we got the wrong one.
213
            --  This means that the name supplied by the user crunched
214
            --  to something we recognized, but then the file did not
215
            --  contain the unit expected. Most likely this is due to
216
            --  a misspelling, e.g.
217
 
218
            --    with Ada.Calender;
219
 
220
            --  This crunches to a-calend, which indeed contains the unit
221
            --  Ada.Calendar, and we can diagnose the misspelling. This
222
            --  is a simple heuristic, but it catches many common cases
223
            --  of misspelling of predefined unit names without needing
224
            --  a full list of them.
225
 
226
            --  Before actually issuing the message, we will check that the
227
            --  unit name is indeed a plausible misspelling of the one we got.
228
 
229
            if Is_Bad_Spelling_Of
230
              (Name_Id (Expect_Name), Name_Id (Actual_Name))
231
            then
232
               Error_Msg_Unit_1 := Actual_Name;
233
               Error_Msg -- CODEFIX
234
                 ("possible misspelling of $$!", Loc);
235
            end if;
236
         end;
237
 
238
      --  Non-predefined file name case. In this case we generate a message
239
      --  and then we quit, because we are in big trouble, and if we try
240
      --  to continue compilation, we get into some nasty situations
241
      --  (for example in some subunit cases).
242
 
243
      else
244
         Error_Msg ("file { does not contain expected unit!", Loc);
245
         Error_Msg_Unit_1 := Expected_Unit (Cur_Unum);
246
         Error_Msg ("\\expected unit $!", Loc);
247
         Error_Msg_Unit_1 := Unit_Name (Cur_Unum);
248
         Error_Msg ("\\found unit $!", Loc);
249
      end if;
250
 
251
      --  In both cases, remove the unit if it is the last unit (which it
252
      --  normally (always?) will be) so that it is out of the way later.
253
 
254
      Remove_Unit (Cur_Unum);
255
   end if;
256
 
257
   --  If current unit is a body, load its corresponding spec
258
 
259
   if Nkind (Unit (Curunit)) = N_Package_Body
260
     or else Nkind (Unit (Curunit)) = N_Subprogram_Body
261
   then
262
      Spec_Name := Get_Spec_Name (Unit_Name (Cur_Unum));
263
      Unum :=
264
        Load_Unit
265
          (Load_Name  => Spec_Name,
266
           Required   => False,
267
           Subunit    => False,
268
           Error_Node => Curunit,
269
           Corr_Body  => Cur_Unum,
270
           PMES       => (Cur_Unum = Main_Unit));
271
 
272
      --  If we successfully load the unit, then set the spec/body pointers.
273
      --  Once again note that if the loaded unit has a fatal error, Load will
274
      --  have set our Fatal_Error flag to propagate this condition.
275
 
276
      if Unum /= No_Unit then
277
         Set_Library_Unit (Curunit, Cunit (Unum));
278
         Set_Library_Unit (Cunit (Unum), Curunit);
279
 
280
         --  If this is a separate spec for the main unit, then we reset
281
         --  Main_Unit_Entity to point to the entity for this separate spec
282
         --  and this is also where we generate the SCO's for this spec.
283
 
284
         if Cur_Unum = Main_Unit then
285
            Main_Unit_Entity := Cunit_Entity (Unum);
286
 
287
            if Generate_SCO then
288
               SCO_Record (Unum);
289
            end if;
290
         end if;
291
 
292
      --  If we don't find the spec, then if we have a subprogram body, we
293
      --  are still OK, we just have a case of a body acting as its own spec
294
 
295
      elsif Nkind (Unit (Curunit)) = N_Subprogram_Body then
296
         Set_Acts_As_Spec (Curunit, True);
297
         Set_Library_Unit (Curunit, Curunit);
298
 
299
      --  Otherwise we do have an error, repeat the load request for the spec
300
      --  with Required set True to generate an appropriate error message.
301
 
302
      else
303
         Unum :=
304
           Load_Unit
305
             (Load_Name  => Spec_Name,
306
              Required   => True,
307
              Subunit    => False,
308
              Error_Node => Curunit);
309
         return;
310
      end if;
311
 
312
   --  If current unit is a child unit spec, load its parent. If the child unit
313
   --  is loaded through a limited with, the parent must be as well.
314
 
315
   elsif     Nkind (Unit (Curunit)) =  N_Package_Declaration
316
     or else Nkind (Unit (Curunit)) =  N_Subprogram_Declaration
317
     or else Nkind (Unit (Curunit)) in N_Generic_Declaration
318
     or else Nkind (Unit (Curunit)) in N_Generic_Instantiation
319
     or else Nkind (Unit (Curunit)) in N_Renaming_Declaration
320
   then
321
      --  Turn style and validity checks off for parent unit
322
 
323
      if not GNAT_Mode then
324
         Reset_Style_Check_Options;
325
         Reset_Validity_Check_Options;
326
      end if;
327
 
328
      Spec_Name := Get_Parent_Spec_Name (Unit_Name (Cur_Unum));
329
 
330
      if Spec_Name /= No_Unit_Name then
331
         Unum :=
332
           Load_Unit
333
             (Load_Name  => Spec_Name,
334
              Required   => True,
335
              Subunit    => False,
336
              Error_Node => Curunit);
337
 
338
         if Unum /= No_Unit then
339
            Set_Parent_Spec (Unit (Curunit), Cunit (Unum));
340
         end if;
341
      end if;
342
 
343
   --  If current unit is a subunit, then load its parent body
344
 
345
   elsif Nkind (Unit (Curunit)) = N_Subunit then
346
      Body_Name := Get_Parent_Body_Name (Unit_Name (Cur_Unum));
347
      Unum :=
348
        Load_Unit
349
          (Load_Name  => Body_Name,
350
           Required   => True,
351
           Subunit    => False,
352
           Error_Node => Name (Unit (Curunit)));
353
 
354
      if Unum /= No_Unit then
355
         Set_Library_Unit (Curunit, Cunit (Unum));
356
      end if;
357
   end if;
358
 
359
   --  Now we load with'ed units, with style/validity checks turned off
360
 
361
   if not GNAT_Mode then
362
      Reset_Style_Check_Options;
363
      Reset_Validity_Check_Options;
364
   end if;
365
 
366
   --  Load the context items in two rounds: the first round handles normal
367
   --  withed units and the second round handles Ada 2005 limited-withed units.
368
   --  This is required to allow the low-level circuitry that detects circular
369
   --  dependencies of units the correct notification of the following error:
370
 
371
   --       limited with D;
372
   --       with D;                  with C;
373
   --       package C is ...         package D is ...
374
 
375
   for Round in 1 .. 2 loop
376
      Context_Node := First (Context_Items (Curunit));
377
      while Present (Context_Node) loop
378
 
379
         --  During the first round we check if there is some limited-with
380
         --  context clause; otherwise the second round will be skipped
381
 
382
         if Nkind (Context_Node) = N_With_Clause
383
           and then Round = 1
384
           and then Limited_Present (Context_Node)
385
         then
386
            Limited_With_Found := True;
387
         end if;
388
 
389
         if Nkind (Context_Node) = N_With_Clause
390
           and then ((Round = 1 and then not Limited_Present (Context_Node))
391
                        or else
392
                     (Round = 2 and then Limited_Present (Context_Node)))
393
         then
394
            With_Node := Context_Node;
395
            Spec_Name := Get_Unit_Name (With_Node);
396
 
397
            Unum :=
398
              Load_Unit
399
                (Load_Name  => Spec_Name,
400
                 Required   => False,
401
                 Subunit    => False,
402
                 Error_Node => With_Node,
403
                 Renamings  => True,
404
                 With_Node  => Context_Node);
405
 
406
            --  If we find the unit, then set spec pointer in the N_With_Clause
407
            --  to point to the compilation unit for the spec. Remember that
408
            --  the Load routine itself sets our Fatal_Error flag if the loaded
409
            --  unit gets a fatal error, so we don't need to worry about that.
410
 
411
            if Unum /= No_Unit then
412
               Set_Library_Unit (With_Node, Cunit (Unum));
413
 
414
            --  If the spec isn't found, then try finding the corresponding
415
            --  body, since it is possible that we have a subprogram body
416
            --  that is acting as a spec (since no spec is present).
417
 
418
            else
419
               Body_Name := Get_Body_Name (Spec_Name);
420
               Unum :=
421
                 Load_Unit
422
                   (Load_Name  => Body_Name,
423
                    Required   => False,
424
                    Subunit    => False,
425
                    Error_Node => With_Node,
426
                    Renamings  => True);
427
 
428
               --  If we got a subprogram body, then mark that we are using
429
               --  the body as a spec in the file table, and set the spec
430
               --  pointer in the N_With_Clause to point to the body entity.
431
 
432
               if Unum /= No_Unit
433
                 and then Nkind (Unit (Cunit (Unum))) = N_Subprogram_Body
434
               then
435
                  With_Cunit := Cunit (Unum);
436
                  Set_Library_Unit (With_Node, With_Cunit);
437
                  Set_Acts_As_Spec (With_Cunit, True);
438
                  Set_Library_Unit (With_Cunit, With_Cunit);
439
 
440
               --  If we couldn't find the body, or if it wasn't a body spec
441
               --  then we are in trouble. We make one more call to Load to
442
               --  require the spec. We know it will fail of course, the
443
               --  purpose is to generate the required error message (we prefer
444
               --  that this message refer to the missing spec, not the body)
445
 
446
               else
447
                  Unum :=
448
                    Load_Unit
449
                      (Load_Name  => Spec_Name,
450
                       Required   => True,
451
                       Subunit    => False,
452
                       Error_Node => With_Node,
453
                       Renamings  => True);
454
 
455
                  --  Here we create a dummy package unit for the missing unit
456
 
457
                  Unum := Create_Dummy_Package_Unit (With_Node, Spec_Name);
458
                  Set_Library_Unit (With_Node, Cunit (Unum));
459
               end if;
460
            end if;
461
         end if;
462
 
463
         Next (Context_Node);
464
      end loop;
465
 
466
      exit when not Limited_With_Found;
467
   end loop;
468
 
469
   --  Restore style/validity check mode for main unit
470
 
471
   Set_Style_Check_Options (Save_Style_Checks);
472
   Opt.Style_Check := Save_Style_Check;
473
   Set_Validity_Check_Options (Save_Validity_Checks);
474
   Opt.Validity_Checks_On := Save_Validity_Check;
475
end Load;

powered by: WebSVN 2.1.0

© copyright 1999-2024 OpenCores.org, equivalent to Oliscience, all rights reserved. OpenCores®, registered trademark.