| 1 |
720 |
jeremybenn |
-- C392C07.A
|
| 2 |
|
|
--
|
| 3 |
|
|
-- Grant of Unlimited Rights
|
| 4 |
|
|
--
|
| 5 |
|
|
-- Under contracts F33600-87-D-0337, F33600-84-D-0280, MDA903-79-C-0687,
|
| 6 |
|
|
-- F08630-91-C-0015, and DCA100-97-D-0025, the U.S. Government obtained
|
| 7 |
|
|
-- unlimited rights in the software and documentation contained herein.
|
| 8 |
|
|
-- Unlimited rights are defined in DFAR 252.227-7013(a)(19). By making
|
| 9 |
|
|
-- this public release, the Government intends to confer upon all
|
| 10 |
|
|
-- recipients unlimited rights equal to those held by the Government.
|
| 11 |
|
|
-- These rights include rights to use, duplicate, release or disclose the
|
| 12 |
|
|
-- released technical data and computer software in whole or in part, in
|
| 13 |
|
|
-- any manner and for any purpose whatsoever, and to have or permit others
|
| 14 |
|
|
-- to do so.
|
| 15 |
|
|
--
|
| 16 |
|
|
-- DISCLAIMER
|
| 17 |
|
|
--
|
| 18 |
|
|
-- ALL MATERIALS OR INFORMATION HEREIN RELEASED, MADE AVAILABLE OR
|
| 19 |
|
|
-- DISCLOSED ARE AS IS. THE GOVERNMENT MAKES NO EXPRESS OR IMPLIED
|
| 20 |
|
|
-- WARRANTY AS TO ANY MATTER WHATSOEVER, INCLUDING THE CONDITIONS OF THE
|
| 21 |
|
|
-- SOFTWARE, DOCUMENTATION OR OTHER INFORMATION RELEASED, MADE AVAILABLE
|
| 22 |
|
|
-- OR DISCLOSED, OR THE OWNERSHIP, MERCHANTABILITY, OR FITNESS FOR A
|
| 23 |
|
|
-- PARTICULAR PURPOSE OF SAID MATERIAL.
|
| 24 |
|
|
--*
|
| 25 |
|
|
--
|
| 26 |
|
|
-- OBJECTIVE:
|
| 27 |
|
|
-- Check that for a call to a dispatching subprogram the subprogram
|
| 28 |
|
|
-- body which is executed is determined by the controlling tag for
|
| 29 |
|
|
-- the case where the call has dynamic tagged controlling operands
|
| 30 |
|
|
-- of the type T. Check for calls to these same subprograms where
|
| 31 |
|
|
-- the operands are of specific statically tagged types:
|
| 32 |
|
|
-- objects (declared or allocated), formal parameters, view
|
| 33 |
|
|
-- conversions, and function calls (both primitive and non-primitive).
|
| 34 |
|
|
--
|
| 35 |
|
|
-- TEST DESCRIPTION:
|
| 36 |
|
|
-- This test uses foundation F392C00 to test the usages of statically
|
| 37 |
|
|
-- tagged objects and values. This test is derived in part from
|
| 38 |
|
|
-- C392C05.
|
| 39 |
|
|
--
|
| 40 |
|
|
--
|
| 41 |
|
|
-- CHANGE HISTORY:
|
| 42 |
|
|
-- 06 Dec 94 SAIC ACVC 2.0
|
| 43 |
|
|
-- 24 Oct 95 SAIC Updated for ACVC 2.0.1
|
| 44 |
|
|
--
|
| 45 |
|
|
--!
|
| 46 |
|
|
|
| 47 |
|
|
with Report;
|
| 48 |
|
|
with TCTouch;
|
| 49 |
|
|
with F392C00_1;
|
| 50 |
|
|
procedure C392C07 is -- Hardware_Store
|
| 51 |
|
|
package Switch renames F392C00_1;
|
| 52 |
|
|
|
| 53 |
|
|
subtype Switch_Class is Switch.Toggle'Class;
|
| 54 |
|
|
|
| 55 |
|
|
type Reference is access all Switch_Class;
|
| 56 |
|
|
|
| 57 |
|
|
A_Switch : aliased Switch.Toggle;
|
| 58 |
|
|
A_Dimmer : aliased Switch.Dimmer;
|
| 59 |
|
|
An_Autodim : aliased Switch.Auto_Dimmer;
|
| 60 |
|
|
|
| 61 |
|
|
type Light_Bank is array(Positive range <>) of Reference;
|
| 62 |
|
|
|
| 63 |
|
|
Lamps : Light_Bank(1..3);
|
| 64 |
|
|
|
| 65 |
|
|
-- dynamically tagged controlling operands : class wide formal parameters
|
| 66 |
|
|
procedure Clamp( Device : in out Switch_Class; On : Boolean := False ) is
|
| 67 |
|
|
begin
|
| 68 |
|
|
if Switch.On( Device ) /= On then
|
| 69 |
|
|
Switch.Flip( Device );
|
| 70 |
|
|
end if;
|
| 71 |
|
|
end Clamp;
|
| 72 |
|
|
function Class_Item(Bank_Pos: Positive) return Switch_Class is
|
| 73 |
|
|
begin
|
| 74 |
|
|
return Lamps(Bank_Pos).all;
|
| 75 |
|
|
end Class_Item;
|
| 76 |
|
|
|
| 77 |
|
|
begin -- Main test procedure.
|
| 78 |
|
|
Report.Test ("C392C07", "Check that a dispatching subprogram call is "
|
| 79 |
|
|
& "determined by the controlling tag for "
|
| 80 |
|
|
& "dynamically tagged controlling operands" );
|
| 81 |
|
|
|
| 82 |
|
|
Lamps := ( A_Switch'Access, A_Dimmer'Access, An_Autodim'Access );
|
| 83 |
|
|
|
| 84 |
|
|
-- dynamically tagged operands referring to
|
| 85 |
|
|
-- statically tagged declared objects
|
| 86 |
|
|
for Knob in Lamps'Range loop
|
| 87 |
|
|
Clamp( Lamps(Knob).all, On => True );
|
| 88 |
|
|
end loop;
|
| 89 |
|
|
TCTouch.Validate( "BABGBABKGBA", "Clamping On Lamps" );
|
| 90 |
|
|
|
| 91 |
|
|
Lamps(1) := new Switch.Toggle;
|
| 92 |
|
|
Lamps(2) := new Switch.Dimmer;
|
| 93 |
|
|
Lamps(3) := new Switch.Auto_Dimmer;
|
| 94 |
|
|
|
| 95 |
|
|
-- turn the full bank of switches ON
|
| 96 |
|
|
-- dynamically tagged allocated objects
|
| 97 |
|
|
for Knob in Lamps'Range loop
|
| 98 |
|
|
Clamp( Lamps(Knob).all, On => True );
|
| 99 |
|
|
end loop;
|
| 100 |
|
|
TCTouch.Validate( "BABGBABKGBA", "Dynamic Allocated");
|
| 101 |
|
|
|
| 102 |
|
|
-- Double check execution correctness
|
| 103 |
|
|
if Switch.Off( Lamps(1).all )
|
| 104 |
|
|
or Switch.Off( Lamps(2).all )
|
| 105 |
|
|
or Switch.Off( Lamps(3).all ) then
|
| 106 |
|
|
Report.Failed( "Bad Value" );
|
| 107 |
|
|
end if;
|
| 108 |
|
|
TCTouch.Validate( "CCC", "Class-wide");
|
| 109 |
|
|
|
| 110 |
|
|
-- turn the full bank of switches OFF
|
| 111 |
|
|
for Knob in Lamps'Range loop
|
| 112 |
|
|
Switch.Flip( Lamps(Knob).all );
|
| 113 |
|
|
end loop;
|
| 114 |
|
|
TCTouch.Validate( "AGBAKGBA", "Dynamic Allocated, Primitive Ops");
|
| 115 |
|
|
|
| 116 |
|
|
-- check switches for OFF
|
| 117 |
|
|
-- a few function calls as operands
|
| 118 |
|
|
for Knob in Lamps'Range loop
|
| 119 |
|
|
if not Switch.Off( Class_Item(Knob) ) then
|
| 120 |
|
|
Report.Failed("At function tests, Switch not OFF");
|
| 121 |
|
|
end if;
|
| 122 |
|
|
end loop;
|
| 123 |
|
|
TCTouch.Validate( "CCC",
|
| 124 |
|
|
"Using function returning class-wide type");
|
| 125 |
|
|
|
| 126 |
|
|
-- Switches are all OFF now.
|
| 127 |
|
|
-- dynamically tagged view conversion
|
| 128 |
|
|
Clamp( Switch_Class( A_Switch ) );
|
| 129 |
|
|
Clamp( Switch_Class( A_Dimmer ) );
|
| 130 |
|
|
Clamp( Switch_Class( An_Autodim ) );
|
| 131 |
|
|
TCTouch.Validate( "BABGBABKGBA", "View Conversions" );
|
| 132 |
|
|
|
| 133 |
|
|
-- dynamically tagged controlling operands : declared class wide objects
|
| 134 |
|
|
-- calling primitive functions
|
| 135 |
|
|
declare
|
| 136 |
|
|
Dine_O_Might : Switch_Class := Switch.TC_CW_TI( 't' );
|
| 137 |
|
|
begin
|
| 138 |
|
|
Switch.Flip( Dine_O_Might );
|
| 139 |
|
|
if Switch.On( Dine_O_Might ) then
|
| 140 |
|
|
Report.Failed( "Exploded at Dine_O_Might" );
|
| 141 |
|
|
end if;
|
| 142 |
|
|
TCTouch.Validate( "WAB", "Dispatching function 1" );
|
| 143 |
|
|
end;
|
| 144 |
|
|
|
| 145 |
|
|
declare
|
| 146 |
|
|
Dyne_A_Mite : Switch_Class := Switch.TC_CW_TI( 'd' );
|
| 147 |
|
|
begin
|
| 148 |
|
|
Switch.Flip( Dyne_A_Mite );
|
| 149 |
|
|
if Switch.On( Dyne_A_Mite ) then
|
| 150 |
|
|
Report.Failed( "Exploded at Dyne_A_Mite" );
|
| 151 |
|
|
end if;
|
| 152 |
|
|
TCTouch.Validate( "WGBAB", "Dispatching function 2" );
|
| 153 |
|
|
end;
|
| 154 |
|
|
|
| 155 |
|
|
declare
|
| 156 |
|
|
Din_Um_Out : Switch_Class := Switch.TC_CW_TI( 'a' );
|
| 157 |
|
|
begin
|
| 158 |
|
|
Switch.Flip( Din_Um_Out );
|
| 159 |
|
|
if Switch.Off( Din_Um_Out ) then
|
| 160 |
|
|
Report.Failed( "Exploded at Din_Um_Out" );
|
| 161 |
|
|
end if;
|
| 162 |
|
|
TCTouch.Validate( "WKCC", "Dispatching function 3" );
|
| 163 |
|
|
|
| 164 |
|
|
-- Non-dispatching function calls.
|
| 165 |
|
|
if not Switch.TC_Non_Disp( Switch.Toggle( Din_Um_Out ) ) then
|
| 166 |
|
|
Report.Failed( "Non primitive, via view conversion" );
|
| 167 |
|
|
end if;
|
| 168 |
|
|
TCTouch.Validate( "X", "View Conversion 1" );
|
| 169 |
|
|
|
| 170 |
|
|
if not Switch.TC_Non_Disp( Switch.Dimmer( Din_Um_Out ) ) then
|
| 171 |
|
|
Report.Failed( "Non primitive, via view conversion" );
|
| 172 |
|
|
end if;
|
| 173 |
|
|
TCTouch.Validate( "Y", "View Conversion 2" );
|
| 174 |
|
|
end;
|
| 175 |
|
|
|
| 176 |
|
|
-- a few more function calls as operands (oops)
|
| 177 |
|
|
if not Switch.On( Switch.Toggle'( Switch.Create ) ) then
|
| 178 |
|
|
Report.Failed("Toggle did not create ""On""");
|
| 179 |
|
|
end if;
|
| 180 |
|
|
|
| 181 |
|
|
if Switch.Off( Switch.Dimmer'( Switch.Create ) ) then
|
| 182 |
|
|
Report.Failed("Dimmer created ""Off""");
|
| 183 |
|
|
end if;
|
| 184 |
|
|
|
| 185 |
|
|
if Switch.Off( Switch.Auto_Dimmer'( Switch.Create ) ) then
|
| 186 |
|
|
Report.Failed("Auto_Dimmer created ""Off""");
|
| 187 |
|
|
end if;
|
| 188 |
|
|
|
| 189 |
|
|
Report.Result;
|
| 190 |
|
|
end C392C07;
|