OpenCores
URL https://opencores.org/ocsvn/openrisc/openrisc/trunk

Subversion Repositories openrisc

[/] [openrisc/] [trunk/] [gnu-old/] [binutils-2.18.50/] [gas/] [doc/] [c-xtensa.texi] - Blame information for rev 866

Go to most recent revision | Details | Compare with Previous | View Log

Line No. Rev Author Line
1 38 julius
@c Copyright (C) 2002, 2003, 2004 Free Software Foundation, Inc.
2
@c This is part of the GAS manual.
3
@c For copying conditions, see the file as.texinfo.
4
@c
5
@ifset GENERIC
6
@page
7
@node Xtensa-Dependent
8
@chapter Xtensa Dependent Features
9
@end ifset
10
@ifclear GENERIC
11
@node Machine Dependencies
12
@chapter Xtensa Dependent Features
13
@end ifclear
14
 
15
@cindex Xtensa architecture
16
This chapter covers features of the @sc{gnu} assembler that are specific
17
to the Xtensa architecture.  For details about the Xtensa instruction
18
set, please consult the @cite{Xtensa Instruction Set Architecture (ISA)
19
Reference Manual}.
20
 
21
@menu
22
* Xtensa Options::              Command-line Options.
23
* Xtensa Syntax::               Assembler Syntax for Xtensa Processors.
24
* Xtensa Optimizations::        Assembler Optimizations.
25
* Xtensa Relaxation::           Other Automatic Transformations.
26
* Xtensa Directives::           Directives for Xtensa Processors.
27
@end menu
28
 
29
@node Xtensa Options
30
@section Command Line Options
31
 
32
The Xtensa version of the @sc{gnu} assembler supports these
33
special options:
34
 
35
@table @code
36
@item --text-section-literals | --no-text-section-literals
37
@kindex --text-section-literals
38
@kindex --no-text-section-literals
39
Control the treatment of literal pools.  The default is
40
@samp{--no-@-text-@-section-@-literals}, which places literals in
41
separate sections in the output file.  This allows the literal pool to be
42
placed in a data RAM/ROM.  With @samp{--text-@-section-@-literals}, the
43
literals are interspersed in the text section in order to keep them as
44
close as possible to their references.  This may be necessary for large
45
assembly files, where the literals would otherwise be out of range of the
46
@code{L32R} instructions in the text section.  These options only affect
47
literals referenced via PC-relative @code{L32R} instructions; literals
48
for absolute mode @code{L32R} instructions are handled separately.
49
@xref{Literal Directive, ,literal}.
50
 
51
@item --absolute-literals | --no-absolute-literals
52
@kindex --absolute-literals
53
@kindex --no-absolute-literals
54
Indicate to the assembler whether @code{L32R} instructions use absolute
55
or PC-relative addressing.  If the processor includes the absolute
56
addressing option, the default is to use absolute @code{L32R}
57
relocations.  Otherwise, only the PC-relative @code{L32R} relocations
58
can be used.
59
 
60
@item --target-align | --no-target-align
61
@kindex --target-align
62
@kindex --no-target-align
63
Enable or disable automatic alignment to reduce branch penalties at some
64
expense in code size.  @xref{Xtensa Automatic Alignment, ,Automatic
65
Instruction Alignment}.  This optimization is enabled by default.  Note
66
that the assembler will always align instructions like @code{LOOP} that
67
have fixed alignment requirements.
68
 
69
@item --longcalls | --no-longcalls
70
@kindex --longcalls
71
@kindex --no-longcalls
72
Enable or disable transformation of call instructions to allow calls
73
across a greater range of addresses.  @xref{Xtensa Call Relaxation,
74
,Function Call Relaxation}.  This option should be used when call
75
targets can potentially be out of range.  It may degrade both code size
76
and performance, but the linker can generally optimize away the
77
unnecessary overhead when a call ends up within range.  The default is
78
@samp{--no-@-longcalls}.
79
 
80
@item --transform | --no-transform
81
@kindex --transform
82
@kindex --no-transform
83
Enable or disable all assembler transformations of Xtensa instructions,
84
including both relaxation and optimization.  The default is
85
@samp{--transform}; @samp{--no-transform} should only be used in the
86
rare cases when the instructions must be exactly as specified in the
87
assembly source.  Using @samp{--no-transform} causes out of range
88
instruction operands to be errors.
89
 
90
@item --rename-section @var{oldname}=@var{newname}
91
@kindex --rename-section
92
Rename the @var{oldname} section to @var{newname}.  This option can be used
93
multiple times to rename multiple sections.
94
@end table
95
 
96
@node Xtensa Syntax
97
@section Assembler Syntax
98
@cindex syntax, Xtensa assembler
99
@cindex Xtensa assembler syntax
100
@cindex FLIX syntax
101
 
102
Block comments are delimited by @samp{/*} and @samp{*/}.  End of line
103
comments may be introduced with either @samp{#} or @samp{//}.
104
 
105
Instructions consist of a leading opcode or macro name followed by
106
whitespace and an optional comma-separated list of operands:
107
 
108
@smallexample
109
@var{opcode} [@var{operand}, @dots{}]
110
@end smallexample
111
 
112
Instructions must be separated by a newline or semicolon.
113
 
114
FLIX instructions, which bundle multiple opcodes together in a single
115
instruction, are specified by enclosing the bundled opcodes inside
116
braces:
117
 
118
@smallexample
119
@group
120
@{
121
[@var{format}]
122
@var{opcode0} [@var{operands}]
123
@end group
124
@var{opcode1} [@var{operands}]
125
@group
126
@var{opcode2} [@var{operands}]
127
@dots{}
128
@}
129
@end group
130
@end smallexample
131
 
132
The opcodes in a FLIX instruction are listed in the same order as the
133
corresponding instruction slots in the TIE format declaration.
134
Directives and labels are not allowed inside the braces of a FLIX
135
instruction.  A particular TIE format name can optionally be specified
136
immediately after the opening brace, but this is usually unnecessary.
137
The assembler will automatically search for a format that can encode the
138
specified opcodes, so the format name need only be specified in rare
139
cases where there is more than one applicable format and where it
140
matters which of those formats is used.  A FLIX instruction can also be
141
specified on a single line by separating the opcodes with semicolons:
142
 
143
@smallexample
144
@{ [@var{format};] @var{opcode0} [@var{operands}]; @var{opcode1} [@var{operands}]; @var{opcode2} [@var{operands}]; @dots{} @}
145
@end smallexample
146
 
147
If an opcode can only be encoded in a FLIX instruction but is not
148
specified as part of a FLIX bundle, the assembler will choose the
149
smallest format where the opcode can be encoded and
150
will fill unused instruction slots with no-ops.
151
 
152
@menu
153
* Xtensa Opcodes::              Opcode Naming Conventions.
154
* Xtensa Registers::            Register Naming.
155
@end menu
156
 
157
@node Xtensa Opcodes
158
@subsection Opcode Names
159
@cindex Xtensa opcode names
160
@cindex opcode names, Xtensa
161
 
162
See the @cite{Xtensa Instruction Set Architecture (ISA) Reference
163
Manual} for a complete list of opcodes and descriptions of their
164
semantics.
165
 
166
@cindex _ opcode prefix
167
If an opcode name is prefixed with an underscore character (@samp{_}),
168
@command{@value{AS}} will not transform that instruction in any way.  The
169
underscore prefix disables both optimization (@pxref{Xtensa
170
Optimizations, ,Xtensa Optimizations}) and relaxation (@pxref{Xtensa
171
Relaxation, ,Xtensa Relaxation}) for that particular instruction.  Only
172
use the underscore prefix when it is essential to select the exact
173
opcode produced by the assembler.  Using this feature unnecessarily
174
makes the code less efficient by disabling assembler optimization and
175
less flexible by disabling relaxation.
176
 
177
Note that this special handling of underscore prefixes only applies to
178
Xtensa opcodes, not to either built-in macros or user-defined macros.
179
When an underscore prefix is used with a macro (e.g., @code{_MOV}), it
180
refers to a different macro.  The assembler generally provides built-in
181
macros both with and without the underscore prefix, where the underscore
182
versions behave as if the underscore carries through to the instructions
183
in the macros.  For example, @code{_MOV} may expand to @code{_MOV.N}@.
184
 
185
The underscore prefix only applies to individual instructions, not to
186
series of instructions.  For example, if a series of instructions have
187
underscore prefixes, the assembler will not transform the individual
188
instructions, but it may insert other instructions between them (e.g.,
189
to align a @code{LOOP} instruction).  To prevent the assembler from
190
modifying a series of instructions as a whole, use the
191
@code{no-transform} directive.  @xref{Transform Directive, ,transform}.
192
 
193
@node Xtensa Registers
194
@subsection Register Names
195
@cindex Xtensa register names
196
@cindex register names, Xtensa
197
@cindex sp register
198
 
199
The assembly syntax for a register file entry is the ``short'' name for
200
a TIE register file followed by the index into that register file.  For
201
example, the general-purpose @code{AR} register file has a short name of
202
@code{a}, so these registers are named @code{a0}@dots{}@code{a15}.
203
As a special feature, @code{sp} is also supported as a synonym for
204
@code{a1}.  Additional registers may be added by processor configuration
205
options and by designer-defined TIE extensions.  An initial @samp{$}
206
character is optional in all register names.
207
 
208
@node Xtensa Optimizations
209
@section Xtensa Optimizations
210
@cindex optimizations
211
 
212
The optimizations currently supported by @command{@value{AS}} are
213
generation of density instructions where appropriate and automatic
214
branch target alignment.
215
 
216
@menu
217
* Density Instructions::        Using Density Instructions.
218
* Xtensa Automatic Alignment::  Automatic Instruction Alignment.
219
@end menu
220
 
221
@node Density Instructions
222
@subsection Using Density Instructions
223
@cindex density instructions
224
 
225
The Xtensa instruction set has a code density option that provides
226
16-bit versions of some of the most commonly used opcodes.  Use of these
227
opcodes can significantly reduce code size.  When possible, the
228
assembler automatically translates instructions from the core
229
Xtensa instruction set into equivalent instructions from the Xtensa code
230
density option.  This translation can be disabled by using underscore
231
prefixes (@pxref{Xtensa Opcodes, ,Opcode Names}), by using the
232
@samp{--no-transform} command-line option (@pxref{Xtensa Options, ,Command
233
Line Options}), or by using the @code{no-transform} directive
234
(@pxref{Transform Directive, ,transform}).
235
 
236
It is a good idea @emph{not} to use the density instructions directly.
237
The assembler will automatically select dense instructions where
238
possible.  If you later need to use an Xtensa processor without the code
239
density option, the same assembly code will then work without modification.
240
 
241
@node Xtensa Automatic Alignment
242
@subsection Automatic Instruction Alignment
243
@cindex alignment of @code{LOOP} instructions
244
@cindex alignment of branch targets
245
@cindex @code{LOOP} instructions, alignment
246
@cindex branch target alignment
247
 
248
The Xtensa assembler will automatically align certain instructions, both
249
to optimize performance and to satisfy architectural requirements.
250
 
251
As an optimization to improve performance, the assembler attempts to
252
align branch targets so they do not cross instruction fetch boundaries.
253
(Xtensa processors can be configured with either 32-bit or 64-bit
254
instruction fetch widths.)  An
255
instruction immediately following a call is treated as a branch target
256
in this context, because it will be the target of a return from the
257
call.  This alignment has the potential to reduce branch penalties at
258
some expense in code size.
259
This optimization is enabled by default.  You can disable it with the
260
@samp{--no-target-@-align} command-line option (@pxref{Xtensa Options,
261
,Command Line Options}).
262
 
263
The target alignment optimization is done without adding instructions
264
that could increase the execution time of the program.  If there are
265
density instructions in the code preceding a target, the assembler can
266
change the target alignment by widening some of those instructions to
267
the equivalent 24-bit instructions.  Extra bytes of padding can be
268
inserted immediately following unconditional jump and return
269
instructions.
270
This approach is usually successful in aligning many, but not all,
271
branch targets.
272
 
273
The @code{LOOP} family of instructions must be aligned such that the
274
first instruction in the loop body does not cross an instruction fetch
275
boundary (e.g., with a 32-bit fetch width, a @code{LOOP} instruction
276
must be on either a 1 or 2 mod 4 byte boundary).  The assembler knows
277
about this restriction and inserts the minimal number of 2 or 3 byte
278
no-op instructions to satisfy it.  When no-op instructions are added,
279
any label immediately preceding the original loop will be moved in order
280
to refer to the loop instruction, not the newly generated no-op
281
instruction.  To preserve binary compatibility across processors with
282
different fetch widths, the assembler conservatively assumes a 32-bit
283
fetch width when aligning @code{LOOP} instructions (except if the first
284
instruction in the loop is a 64-bit instruction).
285
 
286
Previous versions of the assembler automatically aligned @code{ENTRY}
287
instructions to 4-byte boundaries, but that alignment is now the
288
programmer's responsibility.
289
 
290
@node Xtensa Relaxation
291
@section Xtensa Relaxation
292
@cindex relaxation
293
 
294
When an instruction operand is outside the range allowed for that
295
particular instruction field, @command{@value{AS}} can transform the code
296
to use a functionally-equivalent instruction or sequence of
297
instructions.  This process is known as @dfn{relaxation}.  This is
298
typically done for branch instructions because the distance of the
299
branch targets is not known until assembly-time.  The Xtensa assembler
300
offers branch relaxation and also extends this concept to function
301
calls, @code{MOVI} instructions and other instructions with immediate
302
fields.
303
 
304
@menu
305
* Xtensa Branch Relaxation::        Relaxation of Branches.
306
* Xtensa Call Relaxation::          Relaxation of Function Calls.
307
* Xtensa Immediate Relaxation::     Relaxation of other Immediate Fields.
308
@end menu
309
 
310
@node Xtensa Branch Relaxation
311
@subsection Conditional Branch Relaxation
312
@cindex relaxation of branch instructions
313
@cindex branch instructions, relaxation
314
 
315
When the target of a branch is too far away from the branch itself,
316
i.e., when the offset from the branch to the target is too large to fit
317
in the immediate field of the branch instruction, it may be necessary to
318
replace the branch with a branch around a jump.  For example,
319
 
320
@smallexample
321
    beqz    a2, L
322
@end smallexample
323
 
324
may result in:
325
 
326
@smallexample
327
@group
328
    bnez.n  a2, M
329
    j L
330
M:
331
@end group
332
@end smallexample
333
 
334
(The @code{BNEZ.N} instruction would be used in this example only if the
335
density option is available.  Otherwise, @code{BNEZ} would be used.)
336
 
337
This relaxation works well because the unconditional jump instruction
338
has a much larger offset range than the various conditional branches.
339
However, an error will occur if a branch target is beyond the range of a
340
jump instruction.  @command{@value{AS}} cannot relax unconditional jumps.
341
Similarly, an error will occur if the original input contains an
342
unconditional jump to a target that is out of range.
343
 
344
Branch relaxation is enabled by default.  It can be disabled by using
345
underscore prefixes (@pxref{Xtensa Opcodes, ,Opcode Names}), the
346
@samp{--no-transform} command-line option (@pxref{Xtensa Options,
347
,Command Line Options}), or the @code{no-transform} directive
348
(@pxref{Transform Directive, ,transform}).
349
 
350
@node Xtensa Call Relaxation
351
@subsection Function Call Relaxation
352
@cindex relaxation of call instructions
353
@cindex call instructions, relaxation
354
 
355
Function calls may require relaxation because the Xtensa immediate call
356
instructions (@code{CALL0}, @code{CALL4}, @code{CALL8} and
357
@code{CALL12}) provide a PC-relative offset of only 512 Kbytes in either
358
direction.  For larger programs, it may be necessary to use indirect
359
calls (@code{CALLX0}, @code{CALLX4}, @code{CALLX8} and @code{CALLX12})
360
where the target address is specified in a register.  The Xtensa
361
assembler can automatically relax immediate call instructions into
362
indirect call instructions.  This relaxation is done by loading the
363
address of the called function into the callee's return address register
364
and then using a @code{CALLX} instruction.  So, for example:
365
 
366
@smallexample
367
    call8 func
368
@end smallexample
369
 
370
might be relaxed to:
371
 
372
@smallexample
373
@group
374
    .literal .L1, func
375
    l32r    a8, .L1
376
    callx8  a8
377
@end group
378
@end smallexample
379
 
380
Because the addresses of targets of function calls are not generally
381
known until link-time, the assembler must assume the worst and relax all
382
the calls to functions in other source files, not just those that really
383
will be out of range.  The linker can recognize calls that were
384
unnecessarily relaxed, and it will remove the overhead introduced by the
385
assembler for those cases where direct calls are sufficient.
386
 
387
Call relaxation is disabled by default because it can have a negative
388
effect on both code size and performance, although the linker can
389
usually eliminate the unnecessary overhead.  If a program is too large
390
and some of the calls are out of range, function call relaxation can be
391
enabled using the @samp{--longcalls} command-line option or the
392
@code{longcalls} directive (@pxref{Longcalls Directive, ,longcalls}).
393
 
394
@node Xtensa Immediate Relaxation
395
@subsection Other Immediate Field Relaxation
396
@cindex immediate fields, relaxation
397
@cindex relaxation of immediate fields
398
 
399
The assembler normally performs the following other relaxations.  They
400
can be disabled by using underscore prefixes (@pxref{Xtensa Opcodes,
401
,Opcode Names}), the @samp{--no-transform} command-line option
402
(@pxref{Xtensa Options, ,Command Line Options}), or the
403
@code{no-transform} directive (@pxref{Transform Directive, ,transform}).
404
 
405
@cindex @code{MOVI} instructions, relaxation
406
@cindex relaxation of @code{MOVI} instructions
407
The @code{MOVI} machine instruction can only materialize values in the
408
range from -2048 to 2047.  Values outside this range are best
409
materialized with @code{L32R} instructions.  Thus:
410
 
411
@smallexample
412
    movi a0, 100000
413
@end smallexample
414
 
415
is assembled into the following machine code:
416
 
417
@smallexample
418
@group
419
    .literal .L1, 100000
420
    l32r a0, .L1
421
@end group
422
@end smallexample
423
 
424
@cindex @code{L8UI} instructions, relaxation
425
@cindex @code{L16SI} instructions, relaxation
426
@cindex @code{L16UI} instructions, relaxation
427
@cindex @code{L32I} instructions, relaxation
428
@cindex relaxation of @code{L8UI} instructions
429
@cindex relaxation of @code{L16SI} instructions
430
@cindex relaxation of @code{L16UI} instructions
431
@cindex relaxation of @code{L32I} instructions
432
The @code{L8UI} machine instruction can only be used with immediate
433
offsets in the range from 0 to 255. The @code{L16SI} and @code{L16UI}
434
machine instructions can only be used with offsets from 0 to 510.  The
435
@code{L32I} machine instruction can only be used with offsets from 0 to
436
1020.  A load offset outside these ranges can be materialized with
437
an @code{L32R} instruction if the destination register of the load
438
is different than the source address register.  For example:
439
 
440
@smallexample
441
    l32i a1, a0, 2040
442
@end smallexample
443
 
444
is translated to:
445
 
446
@smallexample
447
@group
448
    .literal .L1, 2040
449
    l32r a1, .L1
450
@end group
451
@group
452
    add a1, a0, a1
453
    l32i a1, a1, 0
454
@end group
455
@end smallexample
456
 
457
@noindent
458
If the load destination and source address register are the same, an
459
out-of-range offset causes an error.
460
 
461
@cindex @code{ADDI} instructions, relaxation
462
@cindex relaxation of @code{ADDI} instructions
463
The Xtensa @code{ADDI} instruction only allows immediate operands in the
464
range from -128 to 127.  There are a number of alternate instruction
465
sequences for the @code{ADDI} operation.  First, if the
466
immediate is 0, the @code{ADDI} will be turned into a @code{MOV.N}
467
instruction (or the equivalent @code{OR} instruction if the code density
468
option is not available).  If the @code{ADDI} immediate is outside of
469
the range -128 to 127, but inside the range -32896 to 32639, an
470
@code{ADDMI} instruction or @code{ADDMI}/@code{ADDI} sequence will be
471
used.  Finally, if the immediate is outside of this range and a free
472
register is available, an @code{L32R}/@code{ADD} sequence will be used
473
with a literal allocated from the literal pool.
474
 
475
For example:
476
 
477
@smallexample
478
@group
479
    addi    a5, a6, 0
480
    addi    a5, a6, 512
481
@end group
482
@group
483
    addi    a5, a6, 513
484
    addi    a5, a6, 50000
485
@end group
486
@end smallexample
487
 
488
is assembled into the following:
489
 
490
@smallexample
491
@group
492
    .literal .L1, 50000
493
    mov.n   a5, a6
494
@end group
495
    addmi   a5, a6, 0x200
496
    addmi   a5, a6, 0x200
497
    addi    a5, a5, 1
498
@group
499
    l32r    a5, .L1
500
    add     a5, a6, a5
501
@end group
502
@end smallexample
503
 
504
@node Xtensa Directives
505
@section Directives
506
@cindex Xtensa directives
507
@cindex directives, Xtensa
508
 
509
The Xtensa assembler supports a region-based directive syntax:
510
 
511
@smallexample
512
@group
513
    .begin @var{directive} [@var{options}]
514
    @dots{}
515
    .end @var{directive}
516
@end group
517
@end smallexample
518
 
519
All the Xtensa-specific directives that apply to a region of code use
520
this syntax.
521
 
522
The directive applies to code between the @code{.begin} and the
523
@code{.end}.  The state of the option after the @code{.end} reverts to
524
what it was before the @code{.begin}.
525
A nested @code{.begin}/@code{.end} region can further
526
change the state of the directive without having to be aware of its
527
outer state.  For example, consider:
528
 
529
@smallexample
530
@group
531
    .begin no-transform
532
L:  add a0, a1, a2
533
@end group
534
    .begin transform
535
M:  add a0, a1, a2
536
    .end transform
537
@group
538
N:  add a0, a1, a2
539
    .end no-transform
540
@end group
541
@end smallexample
542
 
543
The @code{ADD} opcodes at @code{L} and @code{N} in the outer
544
@code{no-transform} region both result in @code{ADD} machine instructions,
545
but the assembler selects an @code{ADD.N} instruction for the
546
@code{ADD} at @code{M} in the inner @code{transform} region.
547
 
548
The advantage of this style is that it works well inside macros which can
549
preserve the context of their callers.
550
 
551
The following directives are available:
552
@menu
553
* Schedule Directive::         Enable instruction scheduling.
554
* Longcalls Directive::        Use Indirect Calls for Greater Range.
555
* Transform Directive::        Disable All Assembler Transformations.
556
* Literal Directive::          Intermix Literals with Instructions.
557
* Literal Position Directive:: Specify Inline Literal Pool Locations.
558
* Literal Prefix Directive::   Specify Literal Section Name Prefix.
559
* Absolute Literals Directive:: Control PC-Relative vs. Absolute Literals.
560
@end menu
561
 
562
@node Schedule Directive
563
@subsection schedule
564
@cindex @code{schedule} directive
565
@cindex @code{no-schedule} directive
566
 
567
The @code{schedule} directive is recognized only for compatibility with
568
Tensilica's assembler.
569
 
570
@smallexample
571
@group
572
    .begin [no-]schedule
573
    .end [no-]schedule
574
@end group
575
@end smallexample
576
 
577
This directive is ignored and has no effect on @command{@value{AS}}.
578
 
579
@node Longcalls Directive
580
@subsection longcalls
581
@cindex @code{longcalls} directive
582
@cindex @code{no-longcalls} directive
583
 
584
The @code{longcalls} directive enables or disables function call
585
relaxation.  @xref{Xtensa Call Relaxation, ,Function Call Relaxation}.
586
 
587
@smallexample
588
@group
589
    .begin [no-]longcalls
590
    .end [no-]longcalls
591
@end group
592
@end smallexample
593
 
594
Call relaxation is disabled by default unless the @samp{--longcalls}
595
command-line option is specified.  The @code{longcalls} directive
596
overrides the default determined by the command-line options.
597
 
598
@node Transform Directive
599
@subsection transform
600
@cindex @code{transform} directive
601
@cindex @code{no-transform} directive
602
 
603
This directive enables or disables all assembler transformation,
604
including relaxation (@pxref{Xtensa Relaxation, ,Xtensa Relaxation}) and
605
optimization (@pxref{Xtensa Optimizations, ,Xtensa Optimizations}).
606
 
607
@smallexample
608
@group
609
    .begin [no-]transform
610
    .end [no-]transform
611
@end group
612
@end smallexample
613
 
614
Transformations are enabled by default unless the @samp{--no-transform}
615
option is used.  The @code{transform} directive overrides the default
616
determined by the command-line options.  An underscore opcode prefix,
617
disabling transformation of that opcode, always takes precedence over
618
both directives and command-line flags.
619
 
620
@node Literal Directive
621
@subsection literal
622
@cindex @code{literal} directive
623
 
624
The @code{.literal} directive is used to define literal pool data, i.e.,
625
read-only 32-bit data accessed via @code{L32R} instructions.
626
 
627
@smallexample
628
    .literal @var{label}, @var{value}[, @var{value}@dots{}]
629
@end smallexample
630
 
631
This directive is similar to the standard @code{.word} directive, except
632
that the actual location of the literal data is determined by the
633
assembler and linker, not by the position of the @code{.literal}
634
directive.  Using this directive gives the assembler freedom to locate
635
the literal data in the most appropriate place and possibly to combine
636
identical literals.  For example, the code:
637
 
638
@smallexample
639
@group
640
    entry sp, 40
641
    .literal .L1, sym
642
    l32r    a4, .L1
643
@end group
644
@end smallexample
645
 
646
can be used to load a pointer to the symbol @code{sym} into register
647
@code{a4}.  The value of @code{sym} will not be placed between the
648
@code{ENTRY} and @code{L32R} instructions; instead, the assembler puts
649
the data in a literal pool.
650
 
651
Literal pools are placed by default in separate literal sections;
652
however, when using the @samp{--text-@-section-@-literals}
653
option (@pxref{Xtensa Options, ,Command Line Options}), the literal
654
pools for PC-relative mode @code{L32R} instructions
655
are placed in the current section.@footnote{Literals for the
656
@code{.init} and @code{.fini} sections are always placed in separate
657
sections, even when @samp{--text-@-section-@-literals} is enabled.}
658
These text section literal
659
pools are created automatically before @code{ENTRY} instructions and
660
manually after @samp{.literal_position} directives (@pxref{Literal
661
Position Directive, ,literal_position}).  If there are no preceding
662
@code{ENTRY} instructions, explicit @code{.literal_position} directives
663
must be used to place the text section literal pools; otherwise,
664
@command{@value{AS}} will report an error.
665
 
666
When literals are placed in separate sections, the literal section names
667
are derived from the names of the sections where the literals are
668
defined.  The base literal section names are @code{.literal} for
669
PC-relative mode @code{L32R} instructions and @code{.lit4} for absolute
670
mode @code{L32R} instructions (@pxref{Absolute Literals Directive,
671
,absolute-literals}).  These base names are used for literals defined in
672
the default @code{.text} section.  For literals defined in other
673
sections or within the scope of a @code{literal_prefix} directive
674
(@pxref{Literal Prefix Directive, ,literal_prefix}), the following rules
675
determine the literal section name:
676
 
677
@enumerate
678
@item
679
If the current section is a member of a section group, the literal
680
section name includes the group name as a suffix to the base
681
@code{.literal} or @code{.lit4} name, with a period to separate the base
682
name and group name.  The literal section is also made a member of the
683
group.
684
 
685
@item
686
If the current section name (or @code{literal_prefix} value) begins with
687
``@code{.gnu.linkonce.@var{kind}.}'', the literal section name is formed
688
by replacing ``@code{.@var{kind}}'' with the base @code{.literal} or
689
@code{.lit4} name.  For example, for literals defined in a section named
690
@code{.gnu.linkonce.t.func}, the literal section will be
691
@code{.gnu.linkonce.literal.func} or @code{.gnu.linkonce.lit4.func}.
692
 
693
@item
694
If the current section name (or @code{literal_prefix} value) ends with
695
@code{.text}, the literal section name is formed by replacing that
696
suffix with the base @code{.literal} or @code{.lit4} name.  For example,
697
for literals defined in a section named @code{.iram0.text}, the literal
698
section will be @code{.iram0.literal} or @code{.iram0.lit4}.
699
 
700
@item
701
If none of the preceding conditions apply, the literal section name is
702
formed by adding the base @code{.literal} or @code{.lit4} name as a
703
suffix to the current section name (or @code{literal_prefix} value).
704
@end enumerate
705
 
706
@node Literal Position Directive
707
@subsection literal_position
708
@cindex @code{literal_position} directive
709
 
710
When using @samp{--text-@-section-@-literals} to place literals inline
711
in the section being assembled, the @code{.literal_position} directive
712
can be used to mark a potential location for a literal pool.
713
 
714
@smallexample
715
    .literal_position
716
@end smallexample
717
 
718
The @code{.literal_position} directive is ignored when the
719
@samp{--text-@-section-@-literals} option is not used or when
720
@code{L32R} instructions use the absolute addressing mode.
721
 
722
The assembler will automatically place text section literal pools
723
before @code{ENTRY} instructions, so the @code{.literal_position}
724
directive is only needed to specify some other location for a literal
725
pool.  You may need to add an explicit jump instruction to skip over an
726
inline literal pool.
727
 
728
For example, an interrupt vector does not begin with an @code{ENTRY}
729
instruction so the assembler will be unable to automatically find a good
730
place to put a literal pool.  Moreover, the code for the interrupt
731
vector must be at a specific starting address, so the literal pool
732
cannot come before the start of the code.  The literal pool for the
733
vector must be explicitly positioned in the middle of the vector (before
734
any uses of the literals, due to the negative offsets used by
735
PC-relative @code{L32R} instructions).  The @code{.literal_position}
736
directive can be used to do this.  In the following code, the literal
737
for @samp{M} will automatically be aligned correctly and is placed after
738
the unconditional jump.
739
 
740
@smallexample
741
@group
742
    .global M
743
code_start:
744
@end group
745
    j continue
746
    .literal_position
747
    .align 4
748
@group
749
continue:
750
    movi    a4, M
751
@end group
752
@end smallexample
753
 
754
@node Literal Prefix Directive
755
@subsection literal_prefix
756
@cindex @code{literal_prefix} directive
757
 
758
The @code{literal_prefix} directive allows you to override the default
759
literal section names, which are derived from the names of the sections
760
where the literals are defined.
761
 
762
@smallexample
763
@group
764
    .begin literal_prefix [@var{name}]
765
    .end literal_prefix
766
@end group
767
@end smallexample
768
 
769
For literals defined within the delimited region, the literal section
770
names are derived from the @var{name} argument instead of the name of
771
the current section.  The rules used to derive the literal section names
772
do not change.  @xref{Literal Directive, ,literal}.  If the @var{name}
773
argument is omitted, the literal sections revert to the defaults.  This
774
directive has no effect when using the
775
@samp{--text-@-section-@-literals} option (@pxref{Xtensa Options,
776
,Command Line Options}).
777
 
778
@node Absolute Literals Directive
779
@subsection absolute-literals
780
@cindex @code{absolute-literals} directive
781
@cindex @code{no-absolute-literals} directive
782
 
783
The @code{absolute-@-literals} and @code{no-@-absolute-@-literals}
784
directives control the absolute vs.@: PC-relative mode for @code{L32R}
785
instructions.  These are relevant only for Xtensa configurations that
786
include the absolute addressing option for @code{L32R} instructions.
787
 
788
@smallexample
789
@group
790
    .begin [no-]absolute-literals
791
    .end [no-]absolute-literals
792
@end group
793
@end smallexample
794
 
795
These directives do not change the @code{L32R} mode---they only cause
796
the assembler to emit the appropriate kind of relocation for @code{L32R}
797
instructions and to place the literal values in the appropriate section.
798
To change the @code{L32R} mode, the program must write the
799
@code{LITBASE} special register.  It is the programmer's responsibility
800
to keep track of the mode and indicate to the assembler which mode is
801
used in each region of code.
802
 
803
If the Xtensa configuration includes the absolute @code{L32R} addressing
804
option, the default is to assume absolute @code{L32R} addressing unless
805
the @samp{--no-@-absolute-@-literals} command-line option is specified.
806
Otherwise, the default is to assume PC-relative @code{L32R} addressing.
807
The @code{absolute-@-literals} directive can then be used to override
808
the default determined by the command-line options.
809
 
810
@c Local Variables:
811
@c fill-column: 72
812
@c End:

powered by: WebSVN 2.1.0

© copyright 1999-2024 OpenCores.org, equivalent to Oliscience, all rights reserved. OpenCores®, registered trademark.