OpenCores
URL https://opencores.org/ocsvn/openrisc/openrisc/trunk

Subversion Repositories openrisc

[/] [openrisc/] [trunk/] [gnu-old/] [binutils-2.18.50/] [include/] [opcode/] [ppc.h] - Blame information for rev 853

Go to most recent revision | Details | Compare with Previous | View Log

Line No. Rev Author Line
1 38 julius
/* ppc.h -- Header file for PowerPC opcode table
2
   Copyright 1994, 1995, 1999, 2000, 2001, 2002, 2003, 2004, 2005, 2006,
3
   2007 Free Software Foundation, Inc.
4
   Written by Ian Lance Taylor, Cygnus Support
5
 
6
This file is part of GDB, GAS, and the GNU binutils.
7
 
8
GDB, GAS, and the GNU binutils are free software; you can redistribute
9
them and/or modify them under the terms of the GNU General Public
10
License as published by the Free Software Foundation; either version
11
1, or (at your option) any later version.
12
 
13
GDB, GAS, and the GNU binutils are distributed in the hope that they
14
will be useful, but WITHOUT ANY WARRANTY; without even the implied
15
warranty of MERCHANTABILITY or FITNESS FOR A PARTICULAR PURPOSE.  See
16
the GNU General Public License for more details.
17
 
18
You should have received a copy of the GNU General Public License
19
along with this file; see the file COPYING.  If not, write to the Free
20
Software Foundation, 51 Franklin Street - Fifth Floor, Boston, MA 02110-1301, USA.  */
21
 
22
#ifndef PPC_H
23
#define PPC_H
24
 
25
/* The opcode table is an array of struct powerpc_opcode.  */
26
 
27
struct powerpc_opcode
28
{
29
  /* The opcode name.  */
30
  const char *name;
31
 
32
  /* The opcode itself.  Those bits which will be filled in with
33
     operands are zeroes.  */
34
  unsigned long opcode;
35
 
36
  /* The opcode mask.  This is used by the disassembler.  This is a
37
     mask containing ones indicating those bits which must match the
38
     opcode field, and zeroes indicating those bits which need not
39
     match (and are presumably filled in by operands).  */
40
  unsigned long mask;
41
 
42
  /* One bit flags for the opcode.  These are used to indicate which
43
     specific processors support the instructions.  The defined values
44
     are listed below.  */
45
  unsigned long flags;
46
 
47
  /* An array of operand codes.  Each code is an index into the
48
     operand table.  They appear in the order which the operands must
49
     appear in assembly code, and are terminated by a zero.  */
50
  unsigned char operands[8];
51
};
52
 
53
/* The table itself is sorted by major opcode number, and is otherwise
54
   in the order in which the disassembler should consider
55
   instructions.  */
56
extern const struct powerpc_opcode powerpc_opcodes[];
57
extern const int powerpc_num_opcodes;
58
 
59
/* Values defined for the flags field of a struct powerpc_opcode.  */
60
 
61
/* Opcode is defined for the PowerPC architecture.  */
62
#define PPC_OPCODE_PPC                   1
63
 
64
/* Opcode is defined for the POWER (RS/6000) architecture.  */
65
#define PPC_OPCODE_POWER                 2
66
 
67
/* Opcode is defined for the POWER2 (Rios 2) architecture.  */
68
#define PPC_OPCODE_POWER2                4
69
 
70
/* Opcode is only defined on 32 bit architectures.  */
71
#define PPC_OPCODE_32                    8
72
 
73
/* Opcode is only defined on 64 bit architectures.  */
74
#define PPC_OPCODE_64                 0x10
75
 
76
/* Opcode is supported by the Motorola PowerPC 601 processor.  The 601
77
   is assumed to support all PowerPC (PPC_OPCODE_PPC) instructions,
78
   but it also supports many additional POWER instructions.  */
79
#define PPC_OPCODE_601                0x20
80
 
81
/* Opcode is supported in both the Power and PowerPC architectures
82
   (ie, compiler's -mcpu=common or assembler's -mcom).  */
83
#define PPC_OPCODE_COMMON             0x40
84
 
85
/* Opcode is supported for any Power or PowerPC platform (this is
86
   for the assembler's -many option, and it eliminates duplicates).  */
87
#define PPC_OPCODE_ANY                0x80
88
 
89
/* Opcode is supported as part of the 64-bit bridge.  */
90
#define PPC_OPCODE_64_BRIDGE         0x100
91
 
92
/* Opcode is supported by Altivec Vector Unit */
93
#define PPC_OPCODE_ALTIVEC           0x200
94
 
95
/* Opcode is supported by PowerPC 403 processor.  */
96
#define PPC_OPCODE_403               0x400
97
 
98
/* Opcode is supported by PowerPC BookE processor.  */
99
#define PPC_OPCODE_BOOKE             0x800
100
 
101
/* Opcode is only supported by 64-bit PowerPC BookE processor.  */
102
#define PPC_OPCODE_BOOKE64          0x1000
103
 
104
/* Opcode is supported by PowerPC 440 processor.  */
105
#define PPC_OPCODE_440              0x2000
106
 
107
/* Opcode is only supported by Power4 architecture.  */
108
#define PPC_OPCODE_POWER4           0x4000
109
 
110
/* Opcode isn't supported by Power4 architecture.  */
111
#define PPC_OPCODE_NOPOWER4         0x8000
112
 
113
/* Opcode is only supported by POWERPC Classic architecture.  */
114
#define PPC_OPCODE_CLASSIC         0x10000
115
 
116
/* Opcode is only supported by e500x2 Core.  */
117
#define PPC_OPCODE_SPE             0x20000
118
 
119
/* Opcode is supported by e500x2 Integer select APU.  */
120
#define PPC_OPCODE_ISEL            0x40000
121
 
122
/* Opcode is an e500 SPE floating point instruction.  */
123
#define PPC_OPCODE_EFS             0x80000
124
 
125
/* Opcode is supported by branch locking APU.  */
126
#define PPC_OPCODE_BRLOCK         0x100000
127
 
128
/* Opcode is supported by performance monitor APU.  */
129
#define PPC_OPCODE_PMR            0x200000
130
 
131
/* Opcode is supported by cache locking APU.  */
132
#define PPC_OPCODE_CACHELCK       0x400000
133
 
134
/* Opcode is supported by machine check APU.  */
135
#define PPC_OPCODE_RFMCI          0x800000
136
 
137
/* Opcode is only supported by Power5 architecture.  */
138
#define PPC_OPCODE_POWER5        0x1000000
139
 
140
/* Opcode is supported by PowerPC e300 family.  */
141
#define PPC_OPCODE_E300          0x2000000
142
 
143
/* Opcode is only supported by Power6 architecture.  */
144
#define PPC_OPCODE_POWER6        0x4000000
145
 
146
/* Opcode is only supported by PowerPC Cell family.  */
147
#define PPC_OPCODE_CELL          0x8000000
148
 
149
/* Opcode is supported by CPUs with paired singles support.  */
150
#define PPC_OPCODE_PPCPS         0x10000000
151
 
152
/* Opcode is supported by Power E500MC */
153
#define PPC_OPCODE_E500MC        0x20000000
154
 
155
/* A macro to extract the major opcode from an instruction.  */
156
#define PPC_OP(i) (((i) >> 26) & 0x3f)
157
 
158
/* The operands table is an array of struct powerpc_operand.  */
159
 
160
struct powerpc_operand
161
{
162
  /* A bitmask of bits in the operand.  */
163
  unsigned int bitm;
164
 
165
  /* How far the operand is left shifted in the instruction.
166
     -1 to indicate that BITM and SHIFT cannot be used to determine
167
     where the operand goes in the insn.  */
168
  int shift;
169
 
170
  /* Insertion function.  This is used by the assembler.  To insert an
171
     operand value into an instruction, check this field.
172
 
173
     If it is NULL, execute
174
         i |= (op & o->bitm) << o->shift;
175
     (i is the instruction which we are filling in, o is a pointer to
176
     this structure, and op is the operand value).
177
 
178
     If this field is not NULL, then simply call it with the
179
     instruction and the operand value.  It will return the new value
180
     of the instruction.  If the ERRMSG argument is not NULL, then if
181
     the operand value is illegal, *ERRMSG will be set to a warning
182
     string (the operand will be inserted in any case).  If the
183
     operand value is legal, *ERRMSG will be unchanged (most operands
184
     can accept any value).  */
185
  unsigned long (*insert)
186
    (unsigned long instruction, long op, int dialect, const char **errmsg);
187
 
188
  /* Extraction function.  This is used by the disassembler.  To
189
     extract this operand type from an instruction, check this field.
190
 
191
     If it is NULL, compute
192
         op = (i >> o->shift) & o->bitm;
193
         if ((o->flags & PPC_OPERAND_SIGNED) != 0)
194
           sign_extend (op);
195
     (i is the instruction, o is a pointer to this structure, and op
196
     is the result).
197
 
198
     If this field is not NULL, then simply call it with the
199
     instruction value.  It will return the value of the operand.  If
200
     the INVALID argument is not NULL, *INVALID will be set to
201
     non-zero if this operand type can not actually be extracted from
202
     this operand (i.e., the instruction does not match).  If the
203
     operand is valid, *INVALID will not be changed.  */
204
  long (*extract) (unsigned long instruction, int dialect, int *invalid);
205
 
206
  /* One bit syntax flags.  */
207
  unsigned long flags;
208
};
209
 
210
/* Elements in the table are retrieved by indexing with values from
211
   the operands field of the powerpc_opcodes table.  */
212
 
213
extern const struct powerpc_operand powerpc_operands[];
214
extern const unsigned int num_powerpc_operands;
215
 
216
/* Values defined for the flags field of a struct powerpc_operand.  */
217
 
218
/* This operand takes signed values.  */
219
#define PPC_OPERAND_SIGNED (0x1)
220
 
221
/* This operand takes signed values, but also accepts a full positive
222
   range of values when running in 32 bit mode.  That is, if bits is
223
   16, it takes any value from -0x8000 to 0xffff.  In 64 bit mode,
224
   this flag is ignored.  */
225
#define PPC_OPERAND_SIGNOPT (0x2)
226
 
227
/* This operand does not actually exist in the assembler input.  This
228
   is used to support extended mnemonics such as mr, for which two
229
   operands fields are identical.  The assembler should call the
230
   insert function with any op value.  The disassembler should call
231
   the extract function, ignore the return value, and check the value
232
   placed in the valid argument.  */
233
#define PPC_OPERAND_FAKE (0x4)
234
 
235
/* The next operand should be wrapped in parentheses rather than
236
   separated from this one by a comma.  This is used for the load and
237
   store instructions which want their operands to look like
238
       reg,displacement(reg)
239
   */
240
#define PPC_OPERAND_PARENS (0x8)
241
 
242
/* This operand may use the symbolic names for the CR fields, which
243
   are
244
       lt  0    gt  1   eq  2   so  3   un  3
245
       cr0 0    cr1 1   cr2 2   cr3 3
246
       cr4 4    cr5 5   cr6 6   cr7 7
247
   These may be combined arithmetically, as in cr2*4+gt.  These are
248
   only supported on the PowerPC, not the POWER.  */
249
#define PPC_OPERAND_CR (0x10)
250
 
251
/* This operand names a register.  The disassembler uses this to print
252
   register names with a leading 'r'.  */
253
#define PPC_OPERAND_GPR (0x20)
254
 
255
/* Like PPC_OPERAND_GPR, but don't print a leading 'r' for r0.  */
256
#define PPC_OPERAND_GPR_0 (0x40)
257
 
258
/* This operand names a floating point register.  The disassembler
259
   prints these with a leading 'f'.  */
260
#define PPC_OPERAND_FPR (0x80)
261
 
262
/* This operand is a relative branch displacement.  The disassembler
263
   prints these symbolically if possible.  */
264
#define PPC_OPERAND_RELATIVE (0x100)
265
 
266
/* This operand is an absolute branch address.  The disassembler
267
   prints these symbolically if possible.  */
268
#define PPC_OPERAND_ABSOLUTE (0x200)
269
 
270
/* This operand is optional, and is zero if omitted.  This is used for
271
   example, in the optional BF field in the comparison instructions.  The
272
   assembler must count the number of operands remaining on the line,
273
   and the number of operands remaining for the opcode, and decide
274
   whether this operand is present or not.  The disassembler should
275
   print this operand out only if it is not zero.  */
276
#define PPC_OPERAND_OPTIONAL (0x400)
277
 
278
/* This flag is only used with PPC_OPERAND_OPTIONAL.  If this operand
279
   is omitted, then for the next operand use this operand value plus
280
   1, ignoring the next operand field for the opcode.  This wretched
281
   hack is needed because the Power rotate instructions can take
282
   either 4 or 5 operands.  The disassembler should print this operand
283
   out regardless of the PPC_OPERAND_OPTIONAL field.  */
284
#define PPC_OPERAND_NEXT (0x800)
285
 
286
/* This operand should be regarded as a negative number for the
287
   purposes of overflow checking (i.e., the normal most negative
288
   number is disallowed and one more than the normal most positive
289
   number is allowed).  This flag will only be set for a signed
290
   operand.  */
291
#define PPC_OPERAND_NEGATIVE (0x1000)
292
 
293
/* This operand names a vector unit register.  The disassembler
294
   prints these with a leading 'v'.  */
295
#define PPC_OPERAND_VR (0x2000)
296
 
297
/* This operand is for the DS field in a DS form instruction.  */
298
#define PPC_OPERAND_DS (0x4000)
299
 
300
/* This operand is for the DQ field in a DQ form instruction.  */
301
#define PPC_OPERAND_DQ (0x8000)
302
 
303
/* Valid range of operand is 0..n rather than 0..n-1.  */
304
#define PPC_OPERAND_PLUS1 (0x10000)
305
 
306
/* The POWER and PowerPC assemblers use a few macros.  We keep them
307
   with the operands table for simplicity.  The macro table is an
308
   array of struct powerpc_macro.  */
309
 
310
struct powerpc_macro
311
{
312
  /* The macro name.  */
313
  const char *name;
314
 
315
  /* The number of operands the macro takes.  */
316
  unsigned int operands;
317
 
318
  /* One bit flags for the opcode.  These are used to indicate which
319
     specific processors support the instructions.  The values are the
320
     same as those for the struct powerpc_opcode flags field.  */
321
  unsigned long flags;
322
 
323
  /* A format string to turn the macro into a normal instruction.
324
     Each %N in the string is replaced with operand number N (zero
325
     based).  */
326
  const char *format;
327
};
328
 
329
extern const struct powerpc_macro powerpc_macros[];
330
extern const int powerpc_num_macros;
331
 
332
#endif /* PPC_H */

powered by: WebSVN 2.1.0

© copyright 1999-2024 OpenCores.org, equivalent to Oliscience, all rights reserved. OpenCores®, registered trademark.