OpenCores
URL https://opencores.org/ocsvn/openrisc/openrisc/trunk

Subversion Repositories openrisc

[/] [openrisc/] [trunk/] [gnu-old/] [gcc-4.2.2/] [gcc/] [testsuite/] [ada/] [acats/] [tests/] [c9/] [c974007.a] - Blame information for rev 149

Go to most recent revision | Details | Compare with Previous | View Log

Line No. Rev Author Line
1 149 jeremybenn
-- C974007.A
2
--
3
--                             Grant of Unlimited Rights
4
--
5
--     Under contracts F33600-87-D-0337, F33600-84-D-0280, MDA903-79-C-0687,
6
--     F08630-91-C-0015, and DCA100-97-D-0025, the U.S. Government obtained
7
--     unlimited rights in the software and documentation contained herein.
8
--     Unlimited rights are defined in DFAR 252.227-7013(a)(19).  By making
9
--     this public release, the Government intends to confer upon all
10
--     recipients unlimited rights  equal to those held by the Government.
11
--     These rights include rights to use, duplicate, release or disclose the
12
--     released technical data and computer software in whole or in part, in
13
--     any manner and for any purpose whatsoever, and to have or permit others
14
--     to do so.
15
--
16
--                                    DISCLAIMER
17
--
18
--     ALL MATERIALS OR INFORMATION HEREIN RELEASED, MADE AVAILABLE OR
19
--     DISCLOSED ARE AS IS.  THE GOVERNMENT MAKES NO EXPRESS OR IMPLIED
20
--     WARRANTY AS TO ANY MATTER WHATSOEVER, INCLUDING THE CONDITIONS OF THE
21
--     SOFTWARE, DOCUMENTATION OR OTHER INFORMATION RELEASED, MADE AVAILABLE
22
--     OR DISCLOSED, OR THE OWNERSHIP, MERCHANTABILITY, OR FITNESS FOR A
23
--     PARTICULAR PURPOSE OF SAID MATERIAL.
24
--*
25
--
26
-- OBJECTIVE:
27
--      Check that the sequence of statements of the triggering alternative
28
--      of an asynchronous select statement is not executed if the triggering
29
--      statement is a protected entry call, and the entry is not accepted
30
--      before the abortable part completes. Check that execution continues
31
--      immediately following the asynchronous select.
32
--
33
-- TEST DESCRIPTION:
34
--      Declare a main procedure containing an asynchronous select with a
35
--      protected entry call as triggering statement. Declare a protected
36
--      procedure which sets the protected entry's barrier true. Ensure
37
--      that the entry call is never accepted by not calling the protected
38
--      procedure; the barrier remains false, and the entry call from
39
--      asynchronous select is queued. Since the abortable part will complete
40
--      before the entry is accepted, the sequence of statements of the
41
--      triggering alternative is never executed.
42
--
43
--
44
-- CHANGE HISTORY:
45
--      06 Dec 94   SAIC    ACVC 2.0
46
--
47
--!
48
 
49
 
50
package C974007_0 is  -- Automated teller machine abstraction.
51
 
52
 
53
   -- Flags for testing purposes:
54
   --
55
   Abortable_Part_Executed       : Boolean := False;
56
   Perform_Transaction_Executed  : Boolean := False;
57
   Triggering_Statement_Executed : Boolean := False;
58
 
59
 
60
   type Key_Enum is (None, Cancel, Deposit, Withdraw);
61
 
62
   type Card_Number_Type is private;
63
   type Card_PIN_Type    is private;
64
   type ATM_Card_Type    is private;
65
 
66
 
67
   Transaction_Canceled : exception;
68
 
69
 
70
   protected type ATM_Keyboard_Protected is
71
      entry Cancel_Pressed;
72
      procedure Read_Key;
73
   private
74
      Last_Key_Pressed : Key_Enum := None;
75
   end ATM_Keyboard_Protected;
76
 
77
 
78
   procedure Read_Card (Card : in out ATM_Card_Type);
79
 
80
   procedure Validate_Card (Card : in ATM_Card_Type);
81
 
82
   procedure Perform_Transaction (Card : in ATM_Card_Type);
83
 
84
private
85
 
86
   type Card_Number_Type is range   1 .. 9999;
87
   type Card_PIN_Type    is range 100 ..  999;
88
 
89
   type ATM_Card_Type is record
90
      Number : Card_Number_Type;
91
      PIN    : Card_PIN_Type;
92
   end record;
93
 
94
end C974007_0;
95
 
96
 
97
     --==================================================================--
98
 
99
 
100
with Report;
101
package body C974007_0 is
102
 
103
 
104
   protected body ATM_Keyboard_Protected is
105
 
106
      -- Barrier is false for the live of the test
107
      entry Cancel_Pressed when (Last_Key_Pressed = Cancel) is
108
      begin
109
      Triggering_Statement_Executed  := true;   -- Test has failed
110
      -- (Note: cannot call Report.Failed in the protected entry body]
111
      end Cancel_Pressed;
112
 
113
      procedure Read_Key is                                     -- Never
114
      begin                                                     -- called.
115
         -- Simulate a procedure which reads user keyboard input, and
116
         -- which is called by some interrupt handler.
117
         Last_Key_Pressed := Cancel;
118
      end Read_Key;
119
 
120
   end ATM_Keyboard_Protected;
121
 
122
 
123
   procedure Read_Card (Card : in out ATM_Card_Type) is
124
   begin
125
      Card.Number := 9999;
126
      Card.PIN    := 111;
127
   end Read_Card;
128
 
129
 
130
   procedure Validate_Card (Card : in ATM_Card_Type) is
131
   begin
132
      Abortable_Part_Executed := True;
133
   end Validate_Card;
134
 
135
 
136
   procedure Perform_Transaction (Card : in ATM_Card_Type) is
137
   begin
138
      Perform_Transaction_Executed := True;
139
   end Perform_Transaction;
140
 
141
 
142
end C974007_0;
143
 
144
 
145
     --==================================================================--
146
with Report;
147
 
148
with C974007_0;  -- Automated teller machine abstraction.
149
use  C974007_0;
150
 
151
procedure C974007 is
152
 
153
   Card_Data : ATM_Card_Type;
154
 
155
begin
156
 
157
   Report.Test ("C974007", "ATC: trigger is protected entry call" &
158
                              " and abortable part completes first");
159
 
160
   Read_Card (Card_Data);
161
 
162
   declare
163
      Keyboard : C974007_0.ATM_Keyboard_Protected;
164
   begin
165
 
166
      --                                    --
167
      -- Asynchronous select is tested here --
168
      --                                    --
169
 
170
      select
171
         Keyboard.Cancel_Pressed;        -- Barrier is never set true, so
172
                                         -- entry call is queued and never
173
                                         -- accepted.
174
 
175
         raise Transaction_Canceled;     -- Should not be executed.
176
      then abort
177
         Validate_Card (Card_Data);      -- This call completes before
178
                                         -- Keyboard.Cancel_Pressed can be
179
                                         -- accepted.
180
      end select;
181
      Perform_Transaction (Card_Data);   -- Execution proceeds here after
182
                                         -- Validate_Card completes.
183
   exception
184
      when Transaction_Canceled =>
185
         Report.Failed ("Triggering alternative sequence of statements " &
186
                        "executed");
187
   end;
188
 
189
 
190
   if Triggering_Statement_Executed  then
191
      Report.Failed ("Triggering statement was executed");
192
   end if;
193
 
194
   if not Abortable_Part_Executed then
195
      Report.Failed ("Abortable part not executed");
196
   end if;
197
 
198
   if not Perform_Transaction_Executed then
199
      Report.Failed ("Statements following asynchronous select not " &
200
                     "executed");
201
   end if;
202
 
203
   Report.Result;
204
 
205
end C974007;

powered by: WebSVN 2.1.0

© copyright 1999-2024 OpenCores.org, equivalent to Oliscience, all rights reserved. OpenCores®, registered trademark.