OpenCores
URL https://opencores.org/ocsvn/openrisc_me/openrisc_me/trunk

Subversion Repositories openrisc_me

[/] [openrisc/] [trunk/] [gnu-src/] [binutils-2.18.50/] [gas/] [doc/] [c-sh64.texi] - Blame information for rev 438

Go to most recent revision | Details | Compare with Previous | View Log

Line No. Rev Author Line
1 38 julius
@c Copyright (C) 2002, 2003 Free Software Foundation, Inc.
2
@c This is part of the GAS manual.
3
@c For copying conditions, see the file as.texinfo.
4
@page
5
@node SH64-Dependent
6
@chapter SuperH SH64 Dependent Features
7
 
8
@cindex SH64 support
9
@menu
10
* SH64 Options::              Options
11
* SH64 Syntax::               Syntax
12
* SH64 Directives::           SH64 Machine Directives
13
* SH64 Opcodes::              Opcodes
14
@end menu
15
 
16
@node SH64 Options
17
@section Options
18
 
19
@cindex SH64 options
20
@cindex options, SH64
21
@table @code
22
 
23
@cindex SH64 ISA options
24
@cindex ISA options, SH64
25
@item -isa=sh4 | sh4a
26
Specify the sh4 or sh4a instruction set.
27
@item -isa=dsp
28
Enable sh-dsp insns, and disable sh3e / sh4 insns.
29
@item -isa=fp
30
Enable sh2e, sh3e, sh4, and sh4a insn sets.
31
@item -isa=all
32
Enable sh1, sh2, sh2e, sh3, sh3e, sh4, sh4a, and sh-dsp insn sets.
33
@item -isa=shmedia | -isa=shcompact
34
Specify the default instruction set.  @code{SHmedia} specifies the
35
32-bit opcodes, and @code{SHcompact} specifies the 16-bit opcodes
36
compatible with previous SH families.  The default depends on the ABI
37
selected; the default for the 64-bit ABI is SHmedia, and the default for
38
the 32-bit ABI is SHcompact.  If neither the ABI nor the ISA is
39
specified, the default is 32-bit SHcompact.
40
 
41
Note that the @code{.mode} pseudo-op is not permitted if the ISA is not
42
specified on the command line.
43
 
44
@cindex SH64 ABI options
45
@cindex ABI options, SH64
46
@item -abi=32 | -abi=64
47
Specify the default ABI.  If the ISA is specified and the ABI is not,
48
the default ABI depends on the ISA, with SHmedia defaulting to 64-bit
49
and SHcompact defaulting to 32-bit.
50
 
51
Note that the @code{.abi} pseudo-op is not permitted if the ABI is not
52
specified on the command line.  When the ABI is specified on the command
53
line, any @code{.abi} pseudo-ops in the source must match it.
54
 
55
@item -shcompact-const-crange
56
Emit code-range descriptors for constants in SHcompact code sections.
57
 
58
@item -no-mix
59
Disallow SHmedia code in the same section as constants and SHcompact
60
code.
61
 
62
@item -no-expand
63
Do not expand MOVI, PT, PTA or PTB instructions.
64
 
65
@item -expand-pt32
66
With -abi=64, expand PT, PTA and PTB instructions to 32 bits only.
67
 
68
@end table
69
 
70
@node SH64 Syntax
71
@section Syntax
72
 
73
@menu
74
* SH64-Chars::                Special Characters
75
* SH64-Regs::                 Register Names
76
* SH64-Addressing::           Addressing Modes
77
@end menu
78
 
79
@node SH64-Chars
80
@subsection Special Characters
81
 
82
@cindex line comment character, SH64
83
@cindex SH64 line comment character
84
@samp{!} is the line comment character.
85
 
86
@cindex line separator, SH64
87
@cindex statement separator, SH64
88
@cindex SH64 line separator
89
You can use @samp{;} instead of a newline to separate statements.
90
 
91
@cindex symbol names, @samp{$} in
92
@cindex @code{$} in symbol names
93
Since @samp{$} has no special meaning, you may use it in symbol names.
94
 
95
@node SH64-Regs
96
@subsection Register Names
97
 
98
@cindex SH64 registers
99
@cindex registers, SH64
100
You can use the predefined symbols @samp{r0} through @samp{r63} to refer
101
to the SH64 general registers, @samp{cr0} through @code{cr63} for
102
control registers, @samp{tr0} through @samp{tr7} for target address
103
registers, @samp{fr0} through @samp{fr63} for single-precision floating
104
point registers, @samp{dr0} through @samp{dr62} (even numbered registers
105
only) for double-precision floating point registers, @samp{fv0} through
106
@samp{fv60} (multiples of four only) for single-precision floating point
107
vectors, @samp{fp0} through @samp{fp62} (even numbered registers only)
108
for single-precision floating point pairs, @samp{mtrx0} through
109
@samp{mtrx48} (multiples of 16 only) for 4x4 matrices of
110
single-precision floating point registers, @samp{pc} for the program
111
counter, and @samp{fpscr} for the floating point status and control
112
register.
113
 
114
You can also refer to the control registers by the mnemonics @samp{sr},
115
@samp{ssr}, @samp{pssr}, @samp{intevt}, @samp{expevt}, @samp{pexpevt},
116
@samp{tra}, @samp{spc}, @samp{pspc}, @samp{resvec}, @samp{vbr},
117
@samp{tea}, @samp{dcr}, @samp{kcr0}, @samp{kcr1}, @samp{ctc}, and
118
@samp{usr}.
119
 
120
@node SH64-Addressing
121
@subsection Addressing Modes
122
 
123
@cindex addressing modes, SH64
124
@cindex SH64 addressing modes
125
 
126
SH64 operands consist of either a register or immediate value.  The
127
immediate value can be a constant or label reference (or portion of a
128
label reference), as in this example:
129
 
130
@example
131
        movi    4,r2
132
        pt      function, tr4
133
        movi    (function >> 16) & 65535,r0
134
        shori   function & 65535, r0
135
        ld.l    r0,4,r0
136
@end example
137
 
138
@cindex datalabel, SH64
139
Instruction label references can reference labels in either SHmedia or
140
SHcompact.  To differentiate between the two, labels in SHmedia sections
141
will always have the least significant bit set (i.e. they will be odd),
142
which SHcompact labels will have the least significant bit reset
143
(i.e. they will be even).  If you need to reference the actual address
144
of a label, you can use the @code{datalabel} modifier, as in this
145
example:
146
 
147
@example
148
        .long   function
149
        .long   datalabel function
150
@end example
151
 
152
In that example, the first longword may or may not have the least
153
significant bit set depending on whether the label is an SHmedia label
154
or an SHcompact label.  The second longword will be the actual address
155
of the label, regardless of what type of label it is.
156
 
157
@node SH64 Directives
158
@section SH64 Machine Directives
159
 
160
In addition to the SH directives, the SH64 provides the following
161
directives:
162
 
163
@cindex SH64 machine directives
164
@cindex machine directives, SH64
165
 
166
@table @code
167
 
168
@item .mode [shmedia|shcompact]
169
@itemx .isa [shmedia|shcompact]
170
Specify the ISA for the following instructions (the two directives are
171
equivalent).  Note that programs such as @code{objdump} rely on symbolic
172
labels to determine when such mode switches occur (by checking the least
173
significant bit of the label's address), so such mode/isa changes should
174
always be followed by a label (in practice, this is true anyway).  Note
175
that you cannot use these directives if you didn't specify an ISA on the
176
command line.
177
 
178
@item .abi [32|64]
179
Specify the ABI for the following instructions.  Note that you cannot use
180
this directive unless you specified an ABI on the command line, and the
181
ABIs specified must match.
182
 
183
@item .uaquad
184
Like .uaword and .ualong, this allows you to specify an intentionally
185
unaligned quadword (64 bit word).
186
 
187
@end table
188
 
189
@node SH64 Opcodes
190
@section Opcodes
191
 
192
@cindex SH64 opcode summary
193
@cindex opcode summary, SH64
194
@cindex mnemonics, SH64
195
@cindex instruction summary, SH64
196
For detailed information on the SH64 machine instruction set, see
197
@cite{SuperH 64 bit RISC Series Architecture Manual} (SuperH, Inc.).
198
 
199
@code{@value{AS}} implements all the standard SH64 opcodes.  In
200
addition, the following pseudo-opcodes may be expanded into one or more
201
alternate opcodes:
202
 
203
@table @code
204
 
205
@item movi
206
If the value doesn't fit into a standard @code{movi} opcode,
207
@code{@value{AS}} will replace the @code{movi} with a sequence of
208
@code{movi} and @code{shori} opcodes.
209
 
210
@item pt
211
This expands to a sequence of @code{movi} and @code{shori} opcode,
212
followed by a @code{ptrel} opcode, or to a @code{pta} or @code{ptb}
213
opcode, depending on the label referenced.
214
 
215
@end table

powered by: WebSVN 2.1.0

© copyright 1999-2024 OpenCores.org, equivalent to Oliscience, all rights reserved. OpenCores®, registered trademark.