OpenCores
URL https://opencores.org/ocsvn/openrisc_me/openrisc_me/trunk

Subversion Repositories openrisc_me

[/] [openrisc/] [trunk/] [gnu-src/] [binutils-2.20.1/] [gas/] [doc/] [c-sh64.texi] - Blame information for rev 301

Go to most recent revision | Details | Compare with Previous | View Log

Line No. Rev Author Line
1 205 julius
@c Copyright (C) 2002, 2003, 2008 Free Software Foundation, Inc.
2
@c This is part of the GAS manual.
3
@c For copying conditions, see the file as.texinfo.
4
@page
5
@node SH64-Dependent
6
@chapter SuperH SH64 Dependent Features
7
 
8
@cindex SH64 support
9
@menu
10
* SH64 Options::              Options
11
* SH64 Syntax::               Syntax
12
* SH64 Directives::           SH64 Machine Directives
13
* SH64 Opcodes::              Opcodes
14
@end menu
15
 
16
@node SH64 Options
17
@section Options
18
 
19
@cindex SH64 options
20
@cindex options, SH64
21
@table @code
22
 
23
@cindex SH64 ISA options
24
@cindex ISA options, SH64
25
@item -isa=sh4 | sh4a
26
Specify the sh4 or sh4a instruction set.
27
@item -isa=dsp
28
Enable sh-dsp insns, and disable sh3e / sh4 insns.
29
@item -isa=fp
30
Enable sh2e, sh3e, sh4, and sh4a insn sets.
31
@item -isa=all
32
Enable sh1, sh2, sh2e, sh3, sh3e, sh4, sh4a, and sh-dsp insn sets.
33
@item -isa=shmedia | -isa=shcompact
34
Specify the default instruction set.  @code{SHmedia} specifies the
35
32-bit opcodes, and @code{SHcompact} specifies the 16-bit opcodes
36
compatible with previous SH families.  The default depends on the ABI
37
selected; the default for the 64-bit ABI is SHmedia, and the default for
38
the 32-bit ABI is SHcompact.  If neither the ABI nor the ISA is
39
specified, the default is 32-bit SHcompact.
40
 
41
Note that the @code{.mode} pseudo-op is not permitted if the ISA is not
42
specified on the command line.
43
 
44
@cindex SH64 ABI options
45
@cindex ABI options, SH64
46
@item -abi=32 | -abi=64
47
Specify the default ABI.  If the ISA is specified and the ABI is not,
48
the default ABI depends on the ISA, with SHmedia defaulting to 64-bit
49
and SHcompact defaulting to 32-bit.
50
 
51
Note that the @code{.abi} pseudo-op is not permitted if the ABI is not
52
specified on the command line.  When the ABI is specified on the command
53
line, any @code{.abi} pseudo-ops in the source must match it.
54
 
55
@item -shcompact-const-crange
56
Emit code-range descriptors for constants in SHcompact code sections.
57
 
58
@item -no-mix
59
Disallow SHmedia code in the same section as constants and SHcompact
60
code.
61
 
62
@item -no-expand
63
Do not expand MOVI, PT, PTA or PTB instructions.
64
 
65
@item -expand-pt32
66
With -abi=64, expand PT, PTA and PTB instructions to 32 bits only.
67
 
68
@item -h-tick-hex
69
Support H'00 style hex constants in addition to 0x00 style.
70
 
71
@end table
72
 
73
@node SH64 Syntax
74
@section Syntax
75
 
76
@menu
77
* SH64-Chars::                Special Characters
78
* SH64-Regs::                 Register Names
79
* SH64-Addressing::           Addressing Modes
80
@end menu
81
 
82
@node SH64-Chars
83
@subsection Special Characters
84
 
85
@cindex line comment character, SH64
86
@cindex SH64 line comment character
87
@samp{!} is the line comment character.
88
 
89
@cindex line separator, SH64
90
@cindex statement separator, SH64
91
@cindex SH64 line separator
92
You can use @samp{;} instead of a newline to separate statements.
93
 
94
@cindex symbol names, @samp{$} in
95
@cindex @code{$} in symbol names
96
Since @samp{$} has no special meaning, you may use it in symbol names.
97
 
98
@node SH64-Regs
99
@subsection Register Names
100
 
101
@cindex SH64 registers
102
@cindex registers, SH64
103
You can use the predefined symbols @samp{r0} through @samp{r63} to refer
104
to the SH64 general registers, @samp{cr0} through @code{cr63} for
105
control registers, @samp{tr0} through @samp{tr7} for target address
106
registers, @samp{fr0} through @samp{fr63} for single-precision floating
107
point registers, @samp{dr0} through @samp{dr62} (even numbered registers
108
only) for double-precision floating point registers, @samp{fv0} through
109
@samp{fv60} (multiples of four only) for single-precision floating point
110
vectors, @samp{fp0} through @samp{fp62} (even numbered registers only)
111
for single-precision floating point pairs, @samp{mtrx0} through
112
@samp{mtrx48} (multiples of 16 only) for 4x4 matrices of
113
single-precision floating point registers, @samp{pc} for the program
114
counter, and @samp{fpscr} for the floating point status and control
115
register.
116
 
117
You can also refer to the control registers by the mnemonics @samp{sr},
118
@samp{ssr}, @samp{pssr}, @samp{intevt}, @samp{expevt}, @samp{pexpevt},
119
@samp{tra}, @samp{spc}, @samp{pspc}, @samp{resvec}, @samp{vbr},
120
@samp{tea}, @samp{dcr}, @samp{kcr0}, @samp{kcr1}, @samp{ctc}, and
121
@samp{usr}.
122
 
123
@node SH64-Addressing
124
@subsection Addressing Modes
125
 
126
@cindex addressing modes, SH64
127
@cindex SH64 addressing modes
128
 
129
SH64 operands consist of either a register or immediate value.  The
130
immediate value can be a constant or label reference (or portion of a
131
label reference), as in this example:
132
 
133
@example
134
        movi    4,r2
135
        pt      function, tr4
136
        movi    (function >> 16) & 65535,r0
137
        shori   function & 65535, r0
138
        ld.l    r0,4,r0
139
@end example
140
 
141
@cindex datalabel, SH64
142
Instruction label references can reference labels in either SHmedia or
143
SHcompact.  To differentiate between the two, labels in SHmedia sections
144
will always have the least significant bit set (i.e. they will be odd),
145
which SHcompact labels will have the least significant bit reset
146
(i.e. they will be even).  If you need to reference the actual address
147
of a label, you can use the @code{datalabel} modifier, as in this
148
example:
149
 
150
@example
151
        .long   function
152
        .long   datalabel function
153
@end example
154
 
155
In that example, the first longword may or may not have the least
156
significant bit set depending on whether the label is an SHmedia label
157
or an SHcompact label.  The second longword will be the actual address
158
of the label, regardless of what type of label it is.
159
 
160
@node SH64 Directives
161
@section SH64 Machine Directives
162
 
163
In addition to the SH directives, the SH64 provides the following
164
directives:
165
 
166
@cindex SH64 machine directives
167
@cindex machine directives, SH64
168
 
169
@table @code
170
 
171
@item .mode [shmedia|shcompact]
172
@itemx .isa [shmedia|shcompact]
173
Specify the ISA for the following instructions (the two directives are
174
equivalent).  Note that programs such as @code{objdump} rely on symbolic
175
labels to determine when such mode switches occur (by checking the least
176
significant bit of the label's address), so such mode/isa changes should
177
always be followed by a label (in practice, this is true anyway).  Note
178
that you cannot use these directives if you didn't specify an ISA on the
179
command line.
180
 
181
@item .abi [32|64]
182
Specify the ABI for the following instructions.  Note that you cannot use
183
this directive unless you specified an ABI on the command line, and the
184
ABIs specified must match.
185
 
186
@item .uaquad
187
Like .uaword and .ualong, this allows you to specify an intentionally
188
unaligned quadword (64 bit word).
189
 
190
@end table
191
 
192
@node SH64 Opcodes
193
@section Opcodes
194
 
195
@cindex SH64 opcode summary
196
@cindex opcode summary, SH64
197
@cindex mnemonics, SH64
198
@cindex instruction summary, SH64
199
For detailed information on the SH64 machine instruction set, see
200
@cite{SuperH 64 bit RISC Series Architecture Manual} (SuperH, Inc.).
201
 
202
@code{@value{AS}} implements all the standard SH64 opcodes.  In
203
addition, the following pseudo-opcodes may be expanded into one or more
204
alternate opcodes:
205
 
206
@table @code
207
 
208
@item movi
209
If the value doesn't fit into a standard @code{movi} opcode,
210
@code{@value{AS}} will replace the @code{movi} with a sequence of
211
@code{movi} and @code{shori} opcodes.
212
 
213
@item pt
214
This expands to a sequence of @code{movi} and @code{shori} opcode,
215
followed by a @code{ptrel} opcode, or to a @code{pta} or @code{ptb}
216
opcode, depending on the label referenced.
217
 
218
@end table

powered by: WebSVN 2.1.0

© copyright 1999-2024 OpenCores.org, equivalent to Oliscience, all rights reserved. OpenCores®, registered trademark.