OpenCores
URL https://opencores.org/ocsvn/openrisc/openrisc/trunk

Subversion Repositories openrisc

[/] [openrisc/] [trunk/] [gnu-stable/] [gcc-4.5.1/] [gcc/] [ada/] [sem_ch12.ads] - Blame information for rev 826

Details | Compare with Previous | View Log

Line No. Rev Author Line
1 281 jeremybenn
------------------------------------------------------------------------------
2
--                                                                          --
3
--                         GNAT COMPILER COMPONENTS                         --
4
--                                                                          --
5
--                             S E M _ C H 1 2                              --
6
--                                                                          --
7
--                                 S p e c                                  --
8
--                                                                          --
9
--          Copyright (C) 1992-2009, Free Software Foundation, Inc.         --
10
--                                                                          --
11
-- GNAT is free software;  you can  redistribute it  and/or modify it under --
12
-- terms of the  GNU General Public License as published  by the Free Soft- --
13
-- ware  Foundation;  either version 3,  or (at your option) any later ver- --
14
-- sion.  GNAT is distributed in the hope that it will be useful, but WITH- --
15
-- OUT ANY WARRANTY;  without even the  implied warranty of MERCHANTABILITY --
16
-- or FITNESS FOR A PARTICULAR PURPOSE.  See the GNU General Public License --
17
-- for  more details.  You should have  received  a copy of the GNU General --
18
-- Public License  distributed with GNAT; see file COPYING3.  If not, go to --
19
-- http://www.gnu.org/licenses for a complete copy of the license.          --
20
--                                                                          --
21
-- GNAT was originally developed  by the GNAT team at  New York University. --
22
-- Extensive contributions were provided by Ada Core Technologies Inc.      --
23
--                                                                          --
24
------------------------------------------------------------------------------
25
 
26
with Inline; use Inline;
27
with Types;  use Types;
28
 
29
package Sem_Ch12 is
30
   procedure Analyze_Generic_Package_Declaration        (N : Node_Id);
31
   procedure Analyze_Generic_Subprogram_Declaration     (N : Node_Id);
32
   procedure Analyze_Package_Instantiation              (N : Node_Id);
33
   procedure Analyze_Procedure_Instantiation            (N : Node_Id);
34
   procedure Analyze_Function_Instantiation             (N : Node_Id);
35
   procedure Analyze_Formal_Object_Declaration          (N : Node_Id);
36
   procedure Analyze_Formal_Type_Declaration            (N : Node_Id);
37
   procedure Analyze_Formal_Subprogram                  (N : Node_Id);
38
   procedure Analyze_Formal_Package                     (N : Node_Id);
39
 
40
   procedure Start_Generic;
41
   --  Must be invoked before starting to process a generic spec or body
42
 
43
   procedure End_Generic;
44
   --  Must be invoked just at the end of the end of the processing of a
45
   --  generic spec or body.
46
 
47
   procedure Check_Generic_Child_Unit
48
     (Gen_Id           : Node_Id;
49
      Parent_Installed : in out Boolean);
50
   --  If the name of the generic unit in an instantiation or a renaming is a
51
   --  selected component, then the prefix may be an instance and the selector
52
   --  may designate a child unit. Retrieve the parent generic and search for
53
   --  the child unit that must be declared within. Similarly, if this is the
54
   --  name of a generic child unit within an instantiation of its own parent,
55
   --  retrieve the parent generic. If the parent is installed as a result of
56
   --  this call, then Parent_Installed is set True, otherwise Parent_Intalled
57
   --  is unchanged by the call.
58
 
59
   function Copy_Generic_Node
60
     (N             : Node_Id;
61
      Parent_Id     : Node_Id;
62
      Instantiating : Boolean) return Node_Id;
63
   --  Copy the tree for a generic unit or its body. The unit is copied
64
   --  repeatedly: once to produce a copy on which semantic analysis of
65
   --  the generic is performed, and once for each instantiation. The tree
66
   --  being copied is not semantically analyzed, except that references to
67
   --  global entities are marked on terminal nodes.
68
 
69
   function Get_Instance_Of (A : Entity_Id) return Entity_Id;
70
   --  Retrieve actual associated with given generic parameter.
71
   --  If A is uninstantiated or not a generic parameter, return A.
72
 
73
   function Get_Package_Instantiation_Node (A : Entity_Id) return Node_Id;
74
   --  Given the entity of a unit that is an instantiation, retrieve the
75
   --  original instance node. This is used when loading the instantiations
76
   --  of the ancestors of a child generic that is being instantiated.
77
 
78
   procedure Instantiate_Package_Body
79
     (Body_Info     : Pending_Body_Info;
80
      Inlined_Body  : Boolean := False;
81
      Body_Optional : Boolean := False);
82
   --  Called after semantic analysis, to complete the instantiation of
83
   --  package instances. The flag Inlined_Body is set if the body is
84
   --  being instantiated on the fly for inlined purposes.
85
   --
86
   --  The flag Body_Optional indicates that the call is for an instance
87
   --  that precedes the current instance in the same declarative part.
88
   --  This call is needed when instantiating a nested generic whose body
89
   --  is to be found in the body of an instance. Normally we instantiate
90
   --  package bodies only when they appear in the main unit, or when their
91
   --  contents are needed for a nested generic G. If unit U contains several
92
   --  instances I1, I2, etc. and I2 contains a nested generic, then when U
93
   --  appears in the context of some other unit P that contains an instance
94
   --  of G, we compile the body of I2, but not that of I1. However, when we
95
   --  compile U as the main unit, we compile both bodies. This will lead to
96
   --  lead to link-time errors if the compilation of I1 generates public
97
   --  symbols, because those in I2 will receive different names in both
98
   --  cases. This forces us to analyze the body of I1 even when U is not the
99
   --  main unit. We don't want this additional mechanism to generate an error
100
   --  when the body of the generic for I1 is not present, and this is the
101
   --  reason for the presence of the flag Body_Optional, which is exchanged
102
   --  between the current procedure and Load_Parent_Of_Generic.
103
 
104
   procedure Instantiate_Subprogram_Body
105
     (Body_Info     : Pending_Body_Info;
106
      Body_Optional : Boolean := False);
107
   --  Called after semantic analysis, to complete the instantiation of
108
   --  function and procedure instances. The flag Body_Optional has the
109
   --  same purpose as described for Instantiate_Package_Body.
110
 
111
   function Need_Subprogram_Instance_Body
112
     (N    : Node_Id;
113
      Subp : Entity_Id) return Boolean;
114
 
115
   --  If a subprogram instance is inlined, indicate that the body of it
116
   --  must be created, to be used in inlined calls by the back-end. The
117
   --  subprogram may be inlined because the generic itself carries the
118
   --  pragma, or because a pragma appears for the instance in the scope.
119
   --  of the instance.
120
 
121
   procedure Save_Global_References (N : Node_Id);
122
   --  Traverse the original generic unit, and capture all references to
123
   --  entities that are defined outside of the generic in the analyzed
124
   --  tree for the template. These references are copied into the original
125
   --  tree, so that they appear automatically in every instantiation.
126
   --  A critical invariant in this approach is that if an id in the generic
127
   --  resolves to a local entity, the corresponding id in the instance
128
   --  will resolve to the homologous entity in the instance, even though
129
   --  the enclosing context for resolution is different, as long as the
130
   --  global references have been captured as described here.
131
 
132
   --  Because instantiations can be nested, the environment of the instance,
133
   --  involving the actuals and other data-structures, must be saved and
134
   --  restored in stack-like fashion. Front-end inlining also uses these
135
   --  structures for the management of private/full views.
136
 
137
   procedure Set_Copied_Sloc_For_Inlined_Body (N : Node_Id; E : Entity_Id);
138
   --  This procedure is used when a subprogram body is inlined. This process
139
   --  shares the same circuitry as the creation of an instantiated copy of
140
   --  a generic template. The call to this procedure establishes a new source
141
   --  file entry representing the inlined body as an instantiation, marked as
142
   --  an inlined body (so that errout can distinguish cases for generating
143
   --  error messages, otherwise the treatment is identical). In this call
144
   --  N is the subprogram body and E is the defining identifier of the
145
   --  subprogram in question. The resulting Sloc adjustment factor is
146
   --  saved as part of the internal state of the Sem_Ch12 package for use
147
   --  in subsequent calls to copy nodes.
148
 
149
   procedure Save_Env
150
     (Gen_Unit : Entity_Id;
151
      Act_Unit : Entity_Id);
152
   --   ??? comment needed
153
 
154
   procedure Restore_Env;
155
   --   ??? comment needed
156
 
157
   procedure Initialize;
158
   --  Initializes internal data structures
159
 
160
   procedure Check_Private_View (N : Node_Id);
161
   --  Check whether the type of a generic entity has a different view between
162
   --  the point of generic analysis and the point of instantiation. If the
163
   --  view has changed, then at the point of instantiation we restore the
164
   --  correct view to perform semantic analysis of the instance, and reset
165
   --  the current view after instantiation. The processing is driven by the
166
   --  current private status of the type of the node, and Has_Private_View,
167
   --  a flag that is set at the point of generic compilation. If view and
168
   --  flag are inconsistent then the type is updated appropriately.
169
   --
170
   --  This subprogram is used in Check_Generic_Actuals and Copy_Generic_Node,
171
   --  and is exported here for the purpose of front-end inlining (see Exp_Ch6.
172
   --  Expand_Inlined_Call.Process_Formals).
173
 
174
end Sem_Ch12;

powered by: WebSVN 2.1.0

© copyright 1999-2024 OpenCores.org, equivalent to Oliscience, all rights reserved. OpenCores®, registered trademark.