| 1 |
67 |
julius |
/****************************************************************************************
|
| 2 |
|
|
*
|
| 3 |
|
|
* Disclaimer This software code and all associated documentation, comments or other
|
| 4 |
|
|
* of Warranty: information (collectively "Software") is provided "AS IS" without
|
| 5 |
|
|
* warranty of any kind. MICRON TECHNOLOGY, INC. ("MTI") EXPRESSLY
|
| 6 |
|
|
* DISCLAIMS ALL WARRANTIES EXPRESS OR IMPLIED, INCLUDING BUT NOT LIMITED
|
| 7 |
|
|
* TO, NONINFRINGEMENT OF THIRD PARTY RIGHTS, AND ANY IMPLIED WARRANTIES
|
| 8 |
|
|
* OF MERCHANTABILITY OR FITNESS FOR ANY PARTICULAR PURPOSE. MTI DOES NOT
|
| 9 |
|
|
* WARRANT THAT THE SOFTWARE WILL MEET YOUR REQUIREMENTS, OR THAT THE
|
| 10 |
|
|
* OPERATION OF THE SOFTWARE WILL BE UNINTERRUPTED OR ERROR-FREE.
|
| 11 |
|
|
* FURTHERMORE, MTI DOES NOT MAKE ANY REPRESENTATIONS REGARDING THE USE OR
|
| 12 |
|
|
* THE RESULTS OF THE USE OF THE SOFTWARE IN TERMS OF ITS CORRECTNESS,
|
| 13 |
|
|
* ACCURACY, RELIABILITY, OR OTHERWISE. THE ENTIRE RISK ARISING OUT OF USE
|
| 14 |
|
|
* OR PERFORMANCE OF THE SOFTWARE REMAINS WITH YOU. IN NO EVENT SHALL MTI,
|
| 15 |
|
|
* ITS AFFILIATED COMPANIES OR THEIR SUPPLIERS BE LIABLE FOR ANY DIRECT,
|
| 16 |
|
|
* INDIRECT, CONSEQUENTIAL, INCIDENTAL, OR SPECIAL DAMAGES (INCLUDING,
|
| 17 |
|
|
* WITHOUT LIMITATION, DAMAGES FOR LOSS OF PROFITS, BUSINESS INTERRUPTION,
|
| 18 |
|
|
* OR LOSS OF INFORMATION) ARISING OUT OF YOUR USE OF OR INABILITY TO USE
|
| 19 |
|
|
* THE SOFTWARE, EVEN IF MTI HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH
|
| 20 |
|
|
* DAMAGES. Because some jurisdictions prohibit the exclusion or
|
| 21 |
|
|
* limitation of liability for consequential or incidental damages, the
|
| 22 |
|
|
* above limitation may not apply to you.
|
| 23 |
|
|
*
|
| 24 |
|
|
* Copyright 2003 Micron Technology, Inc. All rights reserved.
|
| 25 |
|
|
*
|
| 26 |
|
|
****************************************************************************************/
|
| 27 |
|
|
|
| 28 |
|
|
// Parameters current with 512Mb datasheet rev N
|
| 29 |
|
|
|
| 30 |
|
|
// Timing parameters based on Speed Grade
|
| 31 |
|
|
|
| 32 |
|
|
// SYMBOL UNITS DESCRIPTION
|
| 33 |
412 |
julius |
`define sg37E
|
| 34 |
|
|
`define x16
|
| 35 |
67 |
julius |
|
| 36 |
|
|
`ifdef sg37E
|
| 37 |
|
|
parameter TCK_MIN = 3750; // tCK ps Minimum Clock Cycle Time
|
| 38 |
|
|
parameter TJIT_PER = 125; // tJIT(per) ps Period JItter
|
| 39 |
|
|
parameter TJIT_DUTY = 125; // tJIT(duty) ps Half Period Jitter
|
| 40 |
|
|
parameter TJIT_CC = 250; // tJIT(cc) ps Cycle to Cycle jitter
|
| 41 |
|
|
parameter TERR_2PER = 175; // tERR(nper) ps Accumulated Error (2-cycle)
|
| 42 |
|
|
parameter TERR_3PER = 225; // tERR(nper) ps Accumulated Error (3-cycle)
|
| 43 |
|
|
parameter TERR_4PER = 250; // tERR(nper) ps Accumulated Error (4-cycle)
|
| 44 |
|
|
parameter TERR_5PER = 250; // tERR(nper) ps Accumulated Error (5-cycle)
|
| 45 |
|
|
parameter TERR_N1PER = 350; // tERR(nper) ps Accumulated Error (6-10-cycle)
|
| 46 |
|
|
parameter TERR_N2PER = 450; // tERR(nper) ps Accumulated Error (11-50-cycle)
|
| 47 |
|
|
parameter TQHS = 400; // tQHS ps Data hold skew factor
|
| 48 |
|
|
parameter TAC = 500; // tAC ps DQ output access time from CK/CK#
|
| 49 |
|
|
parameter TDS = 100; // tDS ps DQ and DM input setup time relative to DQS
|
| 50 |
|
|
parameter TDH = 225; // tDH ps DQ and DM input hold time relative to DQS
|
| 51 |
|
|
parameter TDQSCK = 450; // tDQSCK ps DQS output access time from CK/CK#
|
| 52 |
|
|
parameter TDQSQ = 300; // tDQSQ ps DQS-DQ skew, DQS to last DQ valid, per group, per access
|
| 53 |
|
|
parameter TIS = 250; // tIS ps Input Setup Time
|
| 54 |
|
|
parameter TIH = 375; // tIH ps Input Hold Time
|
| 55 |
|
|
parameter TRC = 55000; // tRC ps Active to Active/Auto Refresh command time
|
| 56 |
|
|
parameter TRCD = 15000; // tRCD ps Active to Read/Write command time
|
| 57 |
|
|
parameter TWTR = 7500; // tWTR ps Write to Read command delay
|
| 58 |
|
|
parameter TRP = 15000; // tRP ps Precharge command period
|
| 59 |
|
|
parameter TRPA = 15000; // tRPA ps Precharge All period
|
| 60 |
|
|
parameter TXARDS = 6; // tXARDS tCK Exit low power active power down to a read command
|
| 61 |
|
|
parameter TXARD = 2; // tXARD tCK Exit active power down to a read command
|
| 62 |
|
|
parameter TXP = 2; // tXP tCK Exit power down to a non-read command
|
| 63 |
|
|
parameter TANPD = 3; // tANPD tCK ODT to power-down entry latency
|
| 64 |
|
|
parameter TAXPD = 8; // tAXPD tCK ODT power-down exit latency
|
| 65 |
|
|
parameter CL_TIME = 15000; // CL ps Minimum CAS Latency
|
| 66 |
|
|
`else // ------ ----- -----------
|
| 67 |
|
|
`ifdef sg187E
|
| 68 |
|
|
parameter TCK_MIN = 1875; // tCK ps Minimum Clock Cycle Time
|
| 69 |
|
|
parameter TJIT_PER = 90; // tJIT(per) ps Period JItter
|
| 70 |
|
|
parameter TJIT_DUTY = 75; // tJIT(duty) ps Half Period Jitter
|
| 71 |
|
|
parameter TJIT_CC = 180; // tJIT(cc) ps Cycle to Cycle jitter
|
| 72 |
|
|
parameter TERR_2PER = 132; // tERR(nper) ps Accumulated Error (2-cycle)
|
| 73 |
|
|
parameter TERR_3PER = 157; // tERR(nper) ps Accumulated Error (3-cycle)
|
| 74 |
|
|
parameter TERR_4PER = 175; // tERR(nper) ps Accumulated Error (4-cycle)
|
| 75 |
|
|
parameter TERR_5PER = 188; // tERR(nper) ps Accumulated Error (5-cycle)
|
| 76 |
|
|
parameter TERR_N1PER = 250; // tERR(nper) ps Accumulated Error (6-10-cycle)
|
| 77 |
|
|
parameter TERR_N2PER = 425; // tERR(nper) ps Accumulated Error (11-50-cycle)
|
| 78 |
|
|
parameter TQHS = 250; // tQHS ps Data hold skew factor
|
| 79 |
|
|
parameter TAC = 350; // tAC ps DQ output access time from CK/CK#
|
| 80 |
|
|
parameter TDS = 0; // tDS ps DQ and DM input setup time relative to DQS
|
| 81 |
|
|
parameter TDH = 75; // tDH ps DQ and DM input hold time relative to DQS
|
| 82 |
|
|
parameter TDQSCK = 300; // tDQSCK ps DQS output access time from CK/CK#
|
| 83 |
|
|
parameter TDQSQ = 175; // tDQSQ ps DQS-DQ skew, DQS to last DQ valid, per group, per access
|
| 84 |
|
|
parameter TIS = 125; // tIS ps Input Setup Time
|
| 85 |
|
|
parameter TIH = 200; // tIH ps Input Hold Time
|
| 86 |
|
|
parameter TRC = 54000; // tRC ps Active to Active/Auto Refresh command time
|
| 87 |
|
|
parameter TRCD = 13125; // tRCD ps Active to Read/Write command time
|
| 88 |
|
|
parameter TWTR = 7500; // tWTR ps Write to Read command delay
|
| 89 |
|
|
parameter TRP = 13125; // tRP ps Precharge command period
|
| 90 |
|
|
parameter TRPA = 13125; // tRPA ps Precharge All period
|
| 91 |
|
|
parameter TXARDS = 10; // tXARDS tCK Exit low power active power down to a read command
|
| 92 |
|
|
parameter TXARD = 3; // tXARD tCK Exit active power down to a read command
|
| 93 |
|
|
parameter TXP = 3; // tXP tCK Exit power down to a non-read command
|
| 94 |
|
|
parameter TANPD = 4; // tANPD tCK ODT to power-down entry latency
|
| 95 |
|
|
parameter TAXPD = 11; // tAXPD tCK ODT power-down exit latency
|
| 96 |
|
|
parameter CL_TIME = 13125; // CL ps Minimum CAS Latency
|
| 97 |
|
|
`else `ifdef sg25E
|
| 98 |
|
|
parameter TCK_MIN = 2500; // tCK ps Minimum Clock Cycle Time
|
| 99 |
|
|
parameter TJIT_PER = 100; // tJIT(per) ps Period JItter
|
| 100 |
|
|
parameter TJIT_DUTY = 100; // tJIT(duty) ps Half Period Jitter
|
| 101 |
|
|
parameter TJIT_CC = 200; // tJIT(cc) ps Cycle to Cycle jitter
|
| 102 |
|
|
parameter TERR_2PER = 150; // tERR(nper) ps Accumulated Error (2-cycle)
|
| 103 |
|
|
parameter TERR_3PER = 175; // tERR(nper) ps Accumulated Error (3-cycle)
|
| 104 |
|
|
parameter TERR_4PER = 200; // tERR(nper) ps Accumulated Error (4-cycle)
|
| 105 |
|
|
parameter TERR_5PER = 200; // tERR(nper) ps Accumulated Error (5-cycle)
|
| 106 |
|
|
parameter TERR_N1PER = 300; // tERR(nper) ps Accumulated Error (6-10-cycle)
|
| 107 |
|
|
parameter TERR_N2PER = 450; // tERR(nper) ps Accumulated Error (11-50-cycle)
|
| 108 |
|
|
parameter TQHS = 300; // tQHS ps Data hold skew factor
|
| 109 |
|
|
parameter TAC = 400; // tAC ps DQ output access time from CK/CK#
|
| 110 |
|
|
parameter TDS = 50; // tDS ps DQ and DM input setup time relative to DQS
|
| 111 |
|
|
parameter TDH = 125; // tDH ps DQ and DM input hold time relative to DQS
|
| 112 |
|
|
parameter TDQSCK = 350; // tDQSCK ps DQS output access time from CK/CK#
|
| 113 |
|
|
parameter TDQSQ = 200; // tDQSQ ps DQS-DQ skew, DQS to last DQ valid, per group, per access
|
| 114 |
|
|
parameter TIS = 175; // tIS ps Input Setup Time
|
| 115 |
|
|
parameter TIH = 250; // tIH ps Input Hold Time
|
| 116 |
|
|
parameter TRC = 55000; // tRC ps Active to Active/Auto Refresh command time
|
| 117 |
|
|
parameter TRCD = 12500; // tRCD ps Active to Read/Write command time
|
| 118 |
|
|
parameter TWTR = 7500; // tWTR ps Write to Read command delay
|
| 119 |
|
|
parameter TRP = 12500; // tRP ps Precharge command period
|
| 120 |
|
|
parameter TRPA = 12500; // tRPA ps Precharge All period
|
| 121 |
|
|
parameter TXARDS = 8; // tXARDS tCK Exit low power active power down to a read command
|
| 122 |
|
|
parameter TXARD = 2; // tXARD tCK Exit active power down to a read command
|
| 123 |
|
|
parameter TXP = 2; // tXP tCK Exit power down to a non-read command
|
| 124 |
|
|
parameter TANPD = 3; // tANPD tCK ODT to power-down entry latency
|
| 125 |
|
|
parameter TAXPD = 10; // tAXPD tCK ODT power-down exit latency
|
| 126 |
|
|
parameter CL_TIME = 12500; // CL ps Minimum CAS Latency
|
| 127 |
|
|
`else `ifdef sg25
|
| 128 |
|
|
parameter TCK_MIN = 2500; // tCK ps Minimum Clock Cycle Time
|
| 129 |
|
|
parameter TJIT_PER = 100; // tJIT(per) ps Period JItter
|
| 130 |
|
|
parameter TJIT_DUTY = 100; // tJIT(duty) ps Half Period Jitter
|
| 131 |
|
|
parameter TJIT_CC = 200; // tJIT(cc) ps Cycle to Cycle jitter
|
| 132 |
|
|
parameter TERR_2PER = 150; // tERR(nper) ps Accumulated Error (2-cycle)
|
| 133 |
|
|
parameter TERR_3PER = 175; // tERR(nper) ps Accumulated Error (3-cycle)
|
| 134 |
|
|
parameter TERR_4PER = 200; // tERR(nper) ps Accumulated Error (4-cycle)
|
| 135 |
|
|
parameter TERR_5PER = 200; // tERR(nper) ps Accumulated Error (5-cycle)
|
| 136 |
|
|
parameter TERR_N1PER = 300; // tERR(nper) ps Accumulated Error (6-10-cycle)
|
| 137 |
|
|
parameter TERR_N2PER = 450; // tERR(nper) ps Accumulated Error (11-50-cycle)
|
| 138 |
|
|
parameter TQHS = 300; // tQHS ps Data hold skew factor
|
| 139 |
|
|
parameter TAC = 400; // tAC ps DQ output access time from CK/CK#
|
| 140 |
|
|
parameter TDS = 50; // tDS ps DQ and DM input setup time relative to DQS
|
| 141 |
|
|
parameter TDH = 125; // tDH ps DQ and DM input hold time relative to DQS
|
| 142 |
|
|
parameter TDQSCK = 350; // tDQSCK ps DQS output access time from CK/CK#
|
| 143 |
|
|
parameter TDQSQ = 200; // tDQSQ ps DQS-DQ skew, DQS to last DQ valid, per group, per access
|
| 144 |
|
|
parameter TIS = 175; // tIS ps Input Setup Time
|
| 145 |
|
|
parameter TIH = 250; // tIH ps Input Hold Time
|
| 146 |
|
|
parameter TRC = 55000; // tRC ps Active to Active/Auto Refresh command time
|
| 147 |
|
|
parameter TRCD = 15000; // tRCD ps Active to Read/Write command time
|
| 148 |
|
|
parameter TWTR = 7500; // tWTR ps Write to Read command delay
|
| 149 |
|
|
parameter TRP = 15000; // tRP ps Precharge command period
|
| 150 |
|
|
parameter TRPA = 15000; // tRPA ps Precharge All period
|
| 151 |
|
|
parameter TXARDS = 8; // tXARDS tCK Exit low power active power down to a read command
|
| 152 |
|
|
parameter TXARD = 2; // tXARD tCK Exit active power down to a read command
|
| 153 |
|
|
parameter TXP = 2; // tXP tCK Exit power down to a non-read command
|
| 154 |
|
|
parameter TANPD = 3; // tANPD tCK ODT to power-down entry latency
|
| 155 |
|
|
parameter TAXPD = 10; // tAXPD tCK ODT power-down exit latency
|
| 156 |
|
|
parameter CL_TIME = 15000; // CL ps Minimum CAS Latency
|
| 157 |
|
|
`else `ifdef sg3E
|
| 158 |
|
|
parameter TCK_MIN = 3000; // tCK ps Minimum Clock Cycle Time
|
| 159 |
|
|
parameter TJIT_PER = 125; // tJIT(per) ps Period JItter
|
| 160 |
|
|
parameter TJIT_DUTY = 125; // tJIT(duty) ps Half Period Jitter
|
| 161 |
|
|
parameter TJIT_CC = 250; // tJIT(cc) ps Cycle to Cycle jitter
|
| 162 |
|
|
parameter TERR_2PER = 175; // tERR(nper) ps Accumulated Error (2-cycle)
|
| 163 |
|
|
parameter TERR_3PER = 225; // tERR(nper) ps Accumulated Error (3-cycle)
|
| 164 |
|
|
parameter TERR_4PER = 250; // tERR(nper) ps Accumulated Error (4-cycle)
|
| 165 |
|
|
parameter TERR_5PER = 250; // tERR(nper) ps Accumulated Error (5-cycle)
|
| 166 |
|
|
parameter TERR_N1PER = 350; // tERR(nper) ps Accumulated Error (6-10-cycle)
|
| 167 |
|
|
parameter TERR_N2PER = 450; // tERR(nper) ps Accumulated Error (11-50-cycle)
|
| 168 |
|
|
parameter TQHS = 340; // tQHS ps Data hold skew factor
|
| 169 |
|
|
parameter TAC = 450; // tAC ps DQ output access time from CK/CK#
|
| 170 |
|
|
parameter TDS = 100; // tDS ps DQ and DM input setup time relative to DQS
|
| 171 |
|
|
parameter TDH = 175; // tDH ps DQ and DM input hold time relative to DQS
|
| 172 |
|
|
parameter TDQSCK = 400; // tDQSCK ps DQS output access time from CK/CK#
|
| 173 |
|
|
parameter TDQSQ = 240; // tDQSQ ps DQS-DQ skew, DQS to last DQ valid, per group, per access
|
| 174 |
|
|
parameter TIS = 200; // tIS ps Input Setup Time
|
| 175 |
|
|
parameter TIH = 275; // tIH ps Input Hold Time
|
| 176 |
|
|
parameter TRC = 54000; // tRC ps Active to Active/Auto Refresh command time
|
| 177 |
|
|
parameter TRCD = 12000; // tRCD ps Active to Read/Write command time
|
| 178 |
|
|
parameter TWTR = 7500; // tWTR ps Write to Read command delay
|
| 179 |
|
|
parameter TRP = 12000; // tRP ps Precharge command period
|
| 180 |
|
|
parameter TRPA = 12000; // tRPA ps Precharge All period
|
| 181 |
|
|
parameter TXARDS = 7; // tXARDS tCK Exit low power active power down to a read command
|
| 182 |
|
|
parameter TXARD = 2; // tXARD tCK Exit active power down to a read command
|
| 183 |
|
|
parameter TXP = 2; // tXP tCK Exit power down to a non-read command
|
| 184 |
|
|
parameter TANPD = 3; // tANPD tCK ODT to power-down entry latency
|
| 185 |
|
|
parameter TAXPD = 8; // tAXPD tCK ODT power-down exit latency
|
| 186 |
|
|
parameter CL_TIME = 12000; // CL ps Minimum CAS Latency
|
| 187 |
|
|
`else `ifdef sg3
|
| 188 |
|
|
parameter TCK_MIN = 3000; // tCK ps Minimum Clock Cycle Time
|
| 189 |
|
|
parameter TJIT_PER = 125; // tJIT(per) ps Period JItter
|
| 190 |
|
|
parameter TJIT_DUTY = 125; // tJIT(duty) ps Half Period Jitter
|
| 191 |
|
|
parameter TJIT_CC = 250; // tJIT(cc) ps Cycle to Cycle jitter
|
| 192 |
|
|
parameter TERR_2PER = 175; // tERR(nper) ps Accumulated Error (2-cycle)
|
| 193 |
|
|
parameter TERR_3PER = 225; // tERR(nper) ps Accumulated Error (3-cycle)
|
| 194 |
|
|
parameter TERR_4PER = 250; // tERR(nper) ps Accumulated Error (4-cycle)
|
| 195 |
|
|
parameter TERR_5PER = 250; // tERR(nper) ps Accumulated Error (5-cycle)
|
| 196 |
|
|
parameter TERR_N1PER = 350; // tERR(nper) ps Accumulated Error (6-10-cycle)
|
| 197 |
|
|
parameter TERR_N2PER = 450; // tERR(nper) ps Accumulated Error (11-50-cycle)
|
| 198 |
|
|
parameter TQHS = 340; // tQHS ps Data hold skew factor
|
| 199 |
|
|
parameter TAC = 450; // tAC ps DQ output access time from CK/CK#
|
| 200 |
|
|
parameter TDS = 100; // tDS ps DQ and DM input setup time relative to DQS
|
| 201 |
|
|
parameter TDH = 175; // tDH ps DQ and DM input hold time relative to DQS
|
| 202 |
|
|
parameter TDQSCK = 400; // tDQSCK ps DQS output access time from CK/CK#
|
| 203 |
|
|
parameter TDQSQ = 240; // tDQSQ ps DQS-DQ skew, DQS to last DQ valid, per group, per access
|
| 204 |
|
|
parameter TIS = 200; // tIS ps Input Setup Time
|
| 205 |
|
|
parameter TIH = 275; // tIH ps Input Hold Time
|
| 206 |
|
|
parameter TRC = 55000; // tRC ps Active to Active/Auto Refresh command time
|
| 207 |
|
|
parameter TRCD = 15000; // tRCD ps Active to Read/Write command time
|
| 208 |
|
|
parameter TWTR = 7500; // tWTR ps Write to Read command delay
|
| 209 |
|
|
parameter TRP = 15000; // tRP ps Precharge command period
|
| 210 |
|
|
parameter TRPA = 15000; // tRPA ps Precharge All period
|
| 211 |
|
|
parameter TXARDS = 7; // tXARDS tCK Exit low power active power down to a read command
|
| 212 |
|
|
parameter TXARD = 2; // tXARD tCK Exit active power down to a read command
|
| 213 |
|
|
parameter TXP = 2; // tXP tCK Exit power down to a non-read command
|
| 214 |
|
|
parameter TANPD = 3; // tANPD tCK ODT to power-down entry latency
|
| 215 |
|
|
parameter TAXPD = 8; // tAXPD tCK ODT power-down exit latency
|
| 216 |
|
|
parameter CL_TIME = 15000; // CL ps Minimum CAS Latency
|
| 217 |
|
|
`else `define sg5E
|
| 218 |
|
|
parameter TCK_MIN = 5000; // tCK ps Minimum Clock Cycle Time
|
| 219 |
|
|
parameter TJIT_PER = 125; // tJIT(per) ps Period JItter
|
| 220 |
|
|
parameter TJIT_DUTY = 150; // tJIT(duty) ps Half Period Jitter
|
| 221 |
|
|
parameter TJIT_CC = 250; // tJIT(cc) ps Cycle to Cycle jitter
|
| 222 |
|
|
parameter TERR_2PER = 175; // tERR(nper) ps Accumulated Error (2-cycle)
|
| 223 |
|
|
parameter TERR_3PER = 225; // tERR(nper) ps Accumulated Error (3-cycle)
|
| 224 |
|
|
parameter TERR_4PER = 250; // tERR(nper) ps Accumulated Error (4-cycle)
|
| 225 |
|
|
parameter TERR_5PER = 250; // tERR(nper) ps Accumulated Error (5-cycle)
|
| 226 |
|
|
parameter TERR_N1PER = 350; // tERR(nper) ps Accumulated Error (6-10-cycle)
|
| 227 |
|
|
parameter TERR_N2PER = 450; // tERR(nper) ps Accumulated Error (11-50-cycle)
|
| 228 |
|
|
parameter TQHS = 450; // tQHS ps Data hold skew factor
|
| 229 |
|
|
parameter TAC = 600; // tAC ps DQ output access time from CK/CK#
|
| 230 |
|
|
parameter TDS = 150; // tDS ps DQ and DM input setup time relative to DQS
|
| 231 |
|
|
parameter TDH = 275; // tDH ps DQ and DM input hold time relative to DQS
|
| 232 |
|
|
parameter TDQSCK = 500; // tDQSCK ps DQS output access time from CK/CK#
|
| 233 |
|
|
parameter TDQSQ = 350; // tDQSQ ps DQS-DQ skew, DQS to last DQ valid, per group, per access
|
| 234 |
|
|
parameter TIS = 350; // tIS ps Input Setup Time
|
| 235 |
|
|
parameter TIH = 475; // tIH ps Input Hold Time
|
| 236 |
|
|
parameter TRC = 55000; // tRC ps Active to Active/Auto Refresh command time
|
| 237 |
|
|
parameter TRCD = 15000; // tRCD ps Active to Read/Write command time
|
| 238 |
|
|
parameter TWTR = 10000; // tWTR ps Write to Read command delay
|
| 239 |
|
|
parameter TRP = 15000; // tRP ps Precharge command period
|
| 240 |
|
|
parameter TRPA = 15000; // tRPA ps Precharge All period
|
| 241 |
|
|
parameter TXARDS = 6; // tXARDS tCK Exit low power active power down to a read command
|
| 242 |
|
|
parameter TXARD = 2; // tXARD tCK Exit active power down to a read command
|
| 243 |
|
|
parameter TXP = 2; // tXP tCK Exit power down to a non-read command
|
| 244 |
|
|
parameter TANPD = 3; // tANPD tCK ODT to power-down entry latency
|
| 245 |
|
|
parameter TAXPD = 8; // tAXPD tCK ODT power-down exit latency
|
| 246 |
|
|
parameter CL_TIME = 15000; // CL ps Minimum CAS Latency
|
| 247 |
|
|
`endif `endif `endif `endif `endif `endif
|
| 248 |
|
|
|
| 249 |
|
|
`ifdef x16
|
| 250 |
|
|
`ifdef sg187E
|
| 251 |
|
|
parameter TFAW = 45000; // tFAW ps Four Bank Activate window
|
| 252 |
|
|
`else `ifdef sg25E
|
| 253 |
|
|
parameter TFAW = 45000; // tFAW ps Four Bank Activate window
|
| 254 |
|
|
`else `ifdef sg25
|
| 255 |
|
|
parameter TFAW = 45000; // tFAW ps Four Bank Activate window
|
| 256 |
|
|
`else // sg3E, sg3, sg37E, sg5E
|
| 257 |
|
|
parameter TFAW = 50000; // tFAW ps Four Bank Activate window
|
| 258 |
|
|
`endif `endif `endif
|
| 259 |
|
|
`else // x4, x8
|
| 260 |
|
|
`ifdef sg187E
|
| 261 |
|
|
parameter TFAW = 35000; // tFAW ps Four Bank Activate window
|
| 262 |
|
|
`else `ifdef sg25E
|
| 263 |
|
|
parameter TFAW = 35000; // tFAW ps Four Bank Activate window
|
| 264 |
|
|
`else `ifdef sg25
|
| 265 |
|
|
parameter TFAW = 35000; // tFAW ps Four Bank Activate window
|
| 266 |
|
|
`else // sg3E, sg3, sg37E, sg5E
|
| 267 |
|
|
parameter TFAW = 37500; // tFAW ps Four Bank Activate window
|
| 268 |
|
|
`endif `endif `endif
|
| 269 |
|
|
`endif
|
| 270 |
|
|
|
| 271 |
|
|
// Timing Parameters
|
| 272 |
|
|
|
| 273 |
|
|
// Mode Register
|
| 274 |
|
|
parameter AL_MIN = 0; // AL tCK Minimum Additive Latency
|
| 275 |
|
|
parameter AL_MAX = 6; // AL tCK Maximum Additive Latency
|
| 276 |
|
|
parameter CL_MIN = 3; // CL tCK Minimum CAS Latency
|
| 277 |
|
|
parameter CL_MAX = 7; // CL tCK Maximum CAS Latency
|
| 278 |
|
|
parameter WR_MIN = 2; // WR tCK Minimum Write Recovery
|
| 279 |
|
|
parameter WR_MAX = 8; // WR tCK Maximum Write Recovery
|
| 280 |
|
|
parameter BL_MIN = 4; // BL tCK Minimum Burst Length
|
| 281 |
|
|
parameter BL_MAX = 8; // BL tCK Minimum Burst Length
|
| 282 |
|
|
// Clock
|
| 283 |
|
|
parameter TCK_MAX = 8000; // tCK ps Maximum Clock Cycle Time
|
| 284 |
|
|
parameter TCH_MIN = 0.48; // tCH tCK Minimum Clock High-Level Pulse Width
|
| 285 |
|
|
parameter TCH_MAX = 0.52; // tCH tCK Maximum Clock High-Level Pulse Width
|
| 286 |
|
|
parameter TCL_MIN = 0.48; // tCL tCK Minimum Clock Low-Level Pulse Width
|
| 287 |
|
|
parameter TCL_MAX = 0.52; // tCL tCK Maximum Clock Low-Level Pulse Width
|
| 288 |
|
|
// Data
|
| 289 |
|
|
parameter TLZ = TAC; // tLZ ps Data-out low-impedance window from CK/CK#
|
| 290 |
|
|
parameter THZ = TAC; // tHZ ps Data-out high impedance window from CK/CK#
|
| 291 |
|
|
parameter TDIPW = 0.35; // tDIPW tCK DQ and DM input Pulse Width
|
| 292 |
|
|
// Data Strobe
|
| 293 |
|
|
parameter TDQSH = 0.35; // tDQSH tCK DQS input High Pulse Width
|
| 294 |
|
|
parameter TDQSL = 0.35; // tDQSL tCK DQS input Low Pulse Width
|
| 295 |
|
|
parameter TDSS = 0.20; // tDSS tCK DQS falling edge to CLK rising (setup time)
|
| 296 |
|
|
parameter TDSH = 0.20; // tDSH tCK DQS falling edge from CLK rising (hold time)
|
| 297 |
|
|
parameter TWPRE = 0.35; // tWPRE tCK DQS Write Preamble
|
| 298 |
|
|
parameter TWPST = 0.40; // tWPST tCK DQS Write Postamble
|
| 299 |
|
|
parameter TDQSS = 0.25; // tDQSS tCK Rising clock edge to DQS/DQS# latching transition
|
| 300 |
|
|
// Command and Address
|
| 301 |
|
|
parameter TIPW = 0.6; // tIPW tCK Control and Address input Pulse Width
|
| 302 |
|
|
parameter TCCD = 2; // tCCD tCK Cas to Cas command delay
|
| 303 |
|
|
parameter TRAS_MIN = 40000; // tRAS ps Minimum Active to Precharge command time
|
| 304 |
|
|
parameter TRAS_MAX =70000000; // tRAS ps Maximum Active to Precharge command time
|
| 305 |
|
|
parameter TRTP = 7500; // tRTP ps Read to Precharge command delay
|
| 306 |
|
|
parameter TWR = 15000; // tWR ps Write recovery time
|
| 307 |
|
|
parameter TMRD = 2; // tMRD tCK Load Mode Register command cycle time
|
| 308 |
|
|
parameter TDLLK = 200; // tDLLK tCK DLL locking time
|
| 309 |
|
|
// Refresh
|
| 310 |
|
|
parameter TRFC_MIN = 105000; // tRFC ps Refresh to Refresh Command interval minimum value
|
| 311 |
|
|
parameter TRFC_MAX =70000000; // tRFC ps Refresh to Refresh Command Interval maximum value
|
| 312 |
|
|
// Self Refresh
|
| 313 |
|
|
parameter TXSNR = TRFC_MIN + 10000; // tXSNR ps Exit self refesh to a non-read command
|
| 314 |
|
|
parameter TXSRD = 200; // tXSRD tCK Exit self refresh to a read command
|
| 315 |
|
|
parameter TISXR = TIS; // tISXR ps CKE setup time during self refresh exit.
|
| 316 |
|
|
// ODT
|
| 317 |
|
|
parameter TAOND = 2; // tAOND tCK ODT turn-on delay
|
| 318 |
|
|
parameter TAOFD = 2.5; // tAOFD tCK ODT turn-off delay
|
| 319 |
|
|
parameter TAONPD = 2000; // tAONPD ps ODT turn-on (precharge power-down mode)
|
| 320 |
|
|
parameter TAOFPD = 2000; // tAOFPD ps ODT turn-off (precharge power-down mode)
|
| 321 |
|
|
parameter TMOD = 12000; // tMOD ps ODT enable in EMR to ODT pin transition
|
| 322 |
|
|
// Power Down
|
| 323 |
|
|
parameter TCKE = 3; // tCKE tCK CKE minimum high or low pulse width
|
| 324 |
|
|
|
| 325 |
|
|
// Size Parameters based on Part Width
|
| 326 |
|
|
|
| 327 |
|
|
`ifdef x4
|
| 328 |
|
|
parameter ADDR_BITS = 14; // Address Bits
|
| 329 |
|
|
parameter ROW_BITS = 14; // Number of Address bits
|
| 330 |
|
|
parameter COL_BITS = 11; // Number of Column bits
|
| 331 |
|
|
parameter DM_BITS = 1; // Number of Data Mask bits
|
| 332 |
|
|
parameter DQ_BITS = 4; // Number of Data bits
|
| 333 |
|
|
parameter DQS_BITS = 1; // Number of Dqs bits
|
| 334 |
|
|
parameter TRRD = 7500; // tRRD Active bank a to Active bank b command time
|
| 335 |
|
|
`else `ifdef x8
|
| 336 |
|
|
parameter ADDR_BITS = 14; // Address Bits
|
| 337 |
|
|
parameter ROW_BITS = 14; // Number of Address bits
|
| 338 |
|
|
parameter COL_BITS = 10; // Number of Column bits
|
| 339 |
|
|
parameter DM_BITS = 1; // Number of Data Mask bits
|
| 340 |
|
|
parameter DQ_BITS = 8; // Number of Data bits
|
| 341 |
|
|
parameter DQS_BITS = 1; // Number of Dqs bits
|
| 342 |
|
|
parameter TRRD = 7500; // tRRD Active bank a to Active bank b command time
|
| 343 |
|
|
`else `define x16
|
| 344 |
|
|
parameter ADDR_BITS = 13; // Address Bits
|
| 345 |
|
|
parameter ROW_BITS = 13; // Number of Address bits
|
| 346 |
|
|
parameter COL_BITS = 10; // Number of Column bits
|
| 347 |
|
|
parameter DM_BITS = 2; // Number of Data Mask bits
|
| 348 |
|
|
parameter DQ_BITS = 16; // Number of Data bits
|
| 349 |
|
|
parameter DQS_BITS = 2; // Number of Dqs bits
|
| 350 |
|
|
parameter TRRD = 10000; // tRRD Active bank a to Active bank b command time
|
| 351 |
|
|
`endif `endif
|
| 352 |
|
|
|
| 353 |
|
|
`ifdef QUAD_RANK
|
| 354 |
|
|
`define DUAL_RANK // also define DUAL_RANK
|
| 355 |
|
|
parameter CS_BITS = 4; // Number of Chip Select Bits
|
| 356 |
|
|
parameter RANKS = 4; // Number of Chip Select Bits
|
| 357 |
|
|
`else `ifdef DUAL_RANK
|
| 358 |
|
|
parameter CS_BITS = 2; // Number of Chip Select Bits
|
| 359 |
|
|
parameter RANKS = 2; // Number of Chip Select Bits
|
| 360 |
|
|
`else
|
| 361 |
|
|
parameter CS_BITS = 2; // Number of Chip Select Bits
|
| 362 |
|
|
parameter RANKS = 1; // Number of Chip Select Bits
|
| 363 |
|
|
`endif `endif
|
| 364 |
|
|
|
| 365 |
|
|
// Size Parameters
|
| 366 |
|
|
parameter BA_BITS = 2; // Set this parmaeter to control how many Bank Address bits
|
| 367 |
412 |
julius |
// if MEM_BITS== 14, a DQ=16 each part, DQ=64 total (4 parts) => 1MB total (256KB each)
|
| 368 |
|
|
// if MEM_BITS== 15, a DQ=16 each part, DQ=64 total (4 parts) => 2MB total (512KB each)
|
| 369 |
|
|
// if MEM_BITS== 16, a DQ=16 each part, DQ=64 total (4 parts) => 4MB total (1MB each)
|
| 370 |
|
|
// if MEM_BITS== 17, a DQ=16 each part, DQ=64 total (4 parts) => 8MB total (2MB each)
|
| 371 |
|
|
//parameter MEM_BITS = 14; // Number of write data bursts can be stored in memory. The default is 2^10=1024.
|
| 372 |
|
|
parameter MEM_BITS = 17; // Number of write data bursts can be stored in memory.
|
| 373 |
67 |
julius |
parameter AP = 10; // the address bit that controls auto-precharge and precharge-all
|
| 374 |
|
|
parameter BL_BITS = 3; // the number of bits required to count to MAX_BL
|
| 375 |
|
|
parameter BO_BITS = 2; // the number of Burst Order Bits
|
| 376 |
|
|
|
| 377 |
|
|
// Simulation parameters
|
| 378 |
|
|
parameter STOP_ON_ERROR = 1; // If set to 1, the model will halt on command sequence/major errors
|
| 379 |
|
|
parameter DEBUG = 0; // Turn on Debug messages
|
| 380 |
|
|
parameter BUS_DELAY = 0; // delay in nanoseconds
|
| 381 |
|
|
parameter RANDOM_OUT_DELAY = 0; // If set to 1, the model will put a random amount of delay on DQ/DQS during reads
|
| 382 |
|
|
parameter RANDOM_SEED = 711689044; //seed value for random generator.
|
| 383 |
|
|
|
| 384 |
|
|
parameter RDQSEN_PRE = 2; // DQS driving time prior to first read strobe
|
| 385 |
|
|
parameter RDQSEN_PST = 1; // DQS driving time after last read strobe
|
| 386 |
|
|
parameter RDQS_PRE = 2; // DQS low time prior to first read strobe
|
| 387 |
|
|
parameter RDQS_PST = 1; // DQS low time after last valid read strobe
|
| 388 |
|
|
parameter RDQEN_PRE = 0; // DQ/DM driving time prior to first read data
|
| 389 |
|
|
parameter RDQEN_PST = 0; // DQ/DM driving time after last read data
|
| 390 |
|
|
parameter WDQS_PRE = 1; // DQS half clock periods prior to first write strobe
|
| 391 |
|
|
parameter WDQS_PST = 1; // DQS half clock periods after last valid write strobe
|