OpenCores
URL https://opencores.org/ocsvn/openrisc/openrisc/trunk

Subversion Repositories openrisc

[/] [openrisc/] [trunk/] [rtos/] [ecos-2.0/] [doc/] [html/] [ref/] [net-snmp-configuring-ecos.html] - Blame information for rev 588

Go to most recent revision | Details | Compare with Previous | View Log

Line No. Rev Author Line
1 28 unneback
<!-- Copyright (C) 2003 Red Hat, Inc.                                -->
2
<!-- This material may be distributed only subject to the terms      -->
3
<!-- and conditions set forth in the Open Publication License, v1.0  -->
4
<!-- or later (the latest version is presently available at          -->
5
<!-- http://www.opencontent.org/openpub/).                           -->
6
<!-- Distribution of the work or derivative of the work in any       -->
7
<!-- standard (paper) book form is prohibited unless prior           -->
8
<!-- permission is obtained from the copyright holder.               -->
9
<HTML
10
><HEAD
11
><TITLE
12
>Configuring eCos</TITLE
13
><meta name="MSSmartTagsPreventParsing" content="TRUE">
14
<META
15
NAME="GENERATOR"
16
CONTENT="Modular DocBook HTML Stylesheet Version 1.76b+
17
"><LINK
18
REL="HOME"
19
TITLE="eCos Reference Manual"
20
HREF="ecos-ref.html"><LINK
21
REL="UP"
22
TITLE="SNMP for eCos"
23
HREF="net-snmp-ecos-port.html"><LINK
24
REL="PREVIOUS"
25
TITLE="Starting the SNMP Agent"
26
HREF="net-snmp-starting-the-snmp-agent.html"><LINK
27
REL="NEXT"
28
TITLE="Test cases"
29
HREF="net-snmp-test-cases.html"></HEAD
30
><BODY
31
CLASS="SECT1"
32
BGCOLOR="#FFFFFF"
33
TEXT="#000000"
34
LINK="#0000FF"
35
VLINK="#840084"
36
ALINK="#0000FF"
37
><DIV
38
CLASS="NAVHEADER"
39
><TABLE
40
SUMMARY="Header navigation table"
41
WIDTH="100%"
42
BORDER="0"
43
CELLPADDING="0"
44
CELLSPACING="0"
45
><TR
46
><TH
47
COLSPAN="3"
48
ALIGN="center"
49
>eCos Reference Manual</TH
50
></TR
51
><TR
52
><TD
53
WIDTH="10%"
54
ALIGN="left"
55
VALIGN="bottom"
56
><A
57
HREF="net-snmp-starting-the-snmp-agent.html"
58
ACCESSKEY="P"
59
>Prev</A
60
></TD
61
><TD
62
WIDTH="80%"
63
ALIGN="center"
64
VALIGN="bottom"
65
>Chapter 47. SNMP for <SPAN
66
CLASS="emphasis"
67
><I
68
CLASS="EMPHASIS"
69
>eCos</I
70
></SPAN
71
></TD
72
><TD
73
WIDTH="10%"
74
ALIGN="right"
75
VALIGN="bottom"
76
><A
77
HREF="net-snmp-test-cases.html"
78
ACCESSKEY="N"
79
>Next</A
80
></TD
81
></TR
82
></TABLE
83
><HR
84
ALIGN="LEFT"
85
WIDTH="100%"></DIV
86
><DIV
87
CLASS="SECT1"
88
><H1
89
CLASS="SECT1"
90
><A
91
NAME="NET-SNMP-CONFIGURING-ECOS">Configuring eCos</H1
92
><P
93
>To use the SNMP agent, the SNMP library and agent packages must be
94
included in your configuration. To incorporate the stack into your
95
configuration select the SNMP library and SNMP agent packages in the
96
eCos Configuration Tool, or at the command line type:
97
<TABLE
98
BORDER="5"
99
BGCOLOR="#E0E0F0"
100
WIDTH="70%"
101
><TR
102
><TD
103
><PRE
104
CLASS="SCREEN"
105
>$ <TT
106
CLASS="USERINPUT"
107
><B
108
>ecosconfig add snmplib snmpagent</B
109
></TT
110
></PRE
111
></TD
112
></TR
113
></TABLE
114
></P
115
><P
116
>After adding the networking, common ethernet device drivers,
117
snmp library and snmp agent packages, there is no configuration
118
required. However there are a number of configuration options
119
that can be set such as some details for the System MIB, and
120
disabling SNMPv3 support (see below).</P
121
><P
122
>Starting the SNMP agent is not integrated into network
123
tests other than <TT
124
CLASS="FILENAME"
125
>snmpping</TT
126
> below, nor is it
127
started automatically in normal eCos startup -
128
it is up to the application to start the agent when it is ready,
129
at least after the network interfaces are both &#8216;up&#8217;.</P
130
><DIV
131
CLASS="SECT2"
132
><H2
133
CLASS="SECT2"
134
><A
135
NAME="NET-SNMP-VERSION-USAGE">Version usage (v1, v2 or v3)</H2
136
><P
137
>The default build supports all three versions of the SNMP protocol, but without
138
any dispatcher functionality (rfc 2571, section 3.1.1.2). This has the
139
following implications :</P
140
><P
141
> 1. There is no community authentication for v1 and v2c.</P
142
><P
143
>2. Security provided by v3 can be bypassed by using v1/v2c protocol.</P
144
><P
145
>To provide the dispatcher with rfc 2571 type functionality, it is required to
146
set up security models and access profiles. This can be provided in the normal
147
Unix style by writing the required configurations in <TT
148
CLASS="LITERAL"
149
>snmpd.conf</TT
150
>
151
file. Application code may setup profiles in <TT
152
CLASS="LITERAL"
153
>snmpd.conf</TT
154
> and
155
optionally set the environment variable <TT
156
CLASS="LITERAL"
157
>SNMPCONFPATH</TT
158
> to
159
point to the file if it is not in the usual location. The whole concept works
160
in the usual way as with the standard UCD-SNMP distribution.</P
161
></DIV
162
><DIV
163
CLASS="SECT2"
164
><H2
165
CLASS="SECT2"
166
><A
167
NAME="TRAPS">Traps</H2
168
><P
169
>The support of the <TT
170
CLASS="LITERAL"
171
>trapsink</TT
172
> command in the
173
<A
174
HREF="net-snmp-agent-manpages-snmpd.conf.html"
175
>snmpd.conf</A
176
> file is not tested
177
and there may be problems for it working as expected. Moreover, in systems that do not
178
have filesystem support, there is no way to configure a trap-session in the
179
conventional way.</P
180
><P
181
>For reasons mentioned above, applications need to initialize their own trap
182
sessions and pass it the details of trap-sink. The following is a small sample
183
for initializing a v1 trap session :</P
184
><TABLE
185
BORDER="5"
186
BGCOLOR="#E0E0F0"
187
WIDTH="70%"
188
><TR
189
><TD
190
><PRE
191
CLASS="PROGRAMLISTING"
192
>typedef struct trap {
193
        unsigned char ip [4];
194
        unsigned int  port;
195
        unsigned char community [256];
196
}
197
 
198
trap            trapsink;
199
unsinged char   sink [16];
200
 
201
...
202
...
203
 
204
if (trapsink.ip != 0) {
205
        sprintf (sink, "%d.%d.%d.%d",
206
                 trapsink[0], trapsink[1], trapsink[2], trapsink[3]);
207
        if (create_trap_session (sink,
208
                trapsink.port,
209
                (char *)trapsink.community,
210
                SNMP_VERSION_1,
211
                SNMP_MSG_TRAP) == 0) {
212
                log_error ("Creation of trap session failed \n");
213
        }
214
}</PRE
215
></TD
216
></TR
217
></TABLE
218
></DIV
219
><DIV
220
CLASS="SECT2"
221
><H2
222
CLASS="SECT2"
223
><A
224
NAME="NET-SNMP-SNMPD-CONF"><TT
225
CLASS="LITERAL"
226
>snmpd.conf</TT
227
> file</H2
228
><P
229
>Using snmpd.conf requires the inclusion of one of the file-system packages
230
(eg. CYGPKG_RAMFS) and CYGPKG_FILEIO. With these two packages included, the
231
SNMP sub-system will read the snmpd.conf file from the location specified in
232
<TT
233
CLASS="LITERAL"
234
>SNMPCONFPATH</TT
235
>, or the standard builtin locations, and use
236
these profiles. Only the profiles specified in the <TT
237
CLASS="LITERAL"
238
>ACCESS-CONTROL</TT
239
>
240
section of <A
241
HREF="net-snmp-agent-manpages-snmpd.conf.html"
242
>snmpd.conf</A
243
> file have
244
been tested and shown to work. Other profiles which have been implemented in
245
<TT
246
CLASS="LITERAL"
247
>UCD-SNMP-4.1.2</TT
248
>'s <TT
249
CLASS="LITERAL"
250
>snmpd.conf</TT
251
> may not work
252
because the sole purpose of adding support for the snmpd.conf file has been to
253
set up <TT
254
CLASS="LITERAL"
255
>ACCESS-CONTROL</TT
256
> models.</P
257
><P
258
>At startup, the SNMP module tries to look for file <TT
259
CLASS="FILENAME"
260
>snmp.conf</TT
261
>.
262
If this file is not available, the module successively looks for files
263
<TT
264
CLASS="FILENAME"
265
>snmpd.conf</TT
266
>, <TT
267
CLASS="FILENAME"
268
>snmp.local.conf</TT
269
> and
270
<TT
271
CLASS="FILENAME"
272
>snmpd.local.conf</TT
273
> at the locations pointed to by <TT
274
CLASS="LITERAL"
275
>SNMPCONFPATH</TT
276
> environment variable. In case <TT
277
CLASS="LITERAL"
278
>SNMPCONFPATH</TT
279
> is not defined, the search sequence is carried out in default directories.
280
The default directories are :<TT
281
CLASS="FILENAME"
282
>/usr/share/snmp</TT
283
>, <TT
284
CLASS="FILENAME"
285
>/usr/local/share/snmp</TT
286
> and <TT
287
CLASS="FILENAME"
288
>$(HOME)/.snmp</TT
289
>.
290
The configurations read from these files are used to control both, SNMP
291
applications and the SNMP agent; in the usual UNIX fashion.</P
292
><P
293
>The inclusion of snmpd.conf support is enabled by default when suitable
294
filesystems and FILEIO packages are active.</P
295
></DIV
296
></DIV
297
><DIV
298
CLASS="NAVFOOTER"
299
><HR
300
ALIGN="LEFT"
301
WIDTH="100%"><TABLE
302
SUMMARY="Footer navigation table"
303
WIDTH="100%"
304
BORDER="0"
305
CELLPADDING="0"
306
CELLSPACING="0"
307
><TR
308
><TD
309
WIDTH="33%"
310
ALIGN="left"
311
VALIGN="top"
312
><A
313
HREF="net-snmp-starting-the-snmp-agent.html"
314
ACCESSKEY="P"
315
>Prev</A
316
></TD
317
><TD
318
WIDTH="34%"
319
ALIGN="center"
320
VALIGN="top"
321
><A
322
HREF="ecos-ref.html"
323
ACCESSKEY="H"
324
>Home</A
325
></TD
326
><TD
327
WIDTH="33%"
328
ALIGN="right"
329
VALIGN="top"
330
><A
331
HREF="net-snmp-test-cases.html"
332
ACCESSKEY="N"
333
>Next</A
334
></TD
335
></TR
336
><TR
337
><TD
338
WIDTH="33%"
339
ALIGN="left"
340
VALIGN="top"
341
>Starting the SNMP Agent</TD
342
><TD
343
WIDTH="34%"
344
ALIGN="center"
345
VALIGN="top"
346
><A
347
HREF="net-snmp-ecos-port.html"
348
ACCESSKEY="U"
349
>Up</A
350
></TD
351
><TD
352
WIDTH="33%"
353
ALIGN="right"
354
VALIGN="top"
355
>Test cases</TD
356
></TR
357
></TABLE
358
></DIV
359
></BODY
360
></HTML
361
>

powered by: WebSVN 2.1.0

© copyright 1999-2024 OpenCores.org, equivalent to Oliscience, all rights reserved. OpenCores®, registered trademark.