OpenCores
URL https://opencores.org/ocsvn/or1k/or1k/trunk

Subversion Repositories or1k

[/] [or1k/] [trunk/] [insight/] [tix/] [man/] [Control.n] - Blame information for rev 1774

Go to most recent revision | Details | Compare with Previous | View Log

Line No. Rev Author Line
1 578 markom
'\"
2
'\" Copyright (c) 1996, Expert Interface Technologies
3
'\"
4
'\" See the file "license.terms" for information on usage and redistribution
5
'\" of this file, and for a DISCLAIMER OF ALL WARRANTIES.
6
'\"
7
'\" The file man.macros and some of the macros used by this file are
8
'\" copyrighted: (c) 1990 The Regents of the University of California.
9
'\"              (c) 1994-1995 Sun Microsystems, Inc.
10
'\" The license terms of the Tcl/Tk distrobution are in the file
11
'\" license.tcl.
12
.so man.macros
13
'----------------------------------------------------------------------
14
.HS tixControl tix 4.0
15
.BS
16
'
17
'
18
'----------------------------------------------------------------------
19
.SH NAME
20
tixControl \- Create and manipulate tixControl widgets
21
'
22
'
23
'
24
'----------------------------------------------------------------------
25
.SH SYNOPSIS
26
\fBtixControl\fI \fIpathName ?\fIoptions\fR?
27
'
28
'
29
'----------------------------------------------------------------------
30
.PP
31
.SH SUPER-CLASS
32
The \fBTixControl\fR class is derived from the \fBTixLabelWidget\fR
33
class and inherits all the commands, options and subwidgets of its
34
super-class.
35
'
36
'----------------------------------------------------------------------
37
.SH "STANDARD OPTIONS"
38
'
39
The Control widget supports all the standard options of a frame
40
widget. See the \fBoptions(n)\fR manual entry for details on the
41
standard options.
42
'
43
'
44
'----------------------------------------------------------------------
45
.SH "WIDGET-SPECIFIC OPTIONS"
46
'
47
'----------BEGIN
48
.LP
49
.nf
50
Name:           \fBallowEmpty\fR
51
Class:          \fBAllowEmpty\fR
52
Switch:         \fB\-allowempty\fR
53
.fi
54
.IP
55
Specifies whether the Control widget should allow the empty string
56
as a valid input.
57
'----------END
58
'
59
'----------BEGIN
60
.LP
61
.nf
62
Name:           \fBautorepeat\fR
63
Class:          \fBAutoRepeat\fR
64
Switch:         \fB\-autorepeat\fR
65
.fi
66
.IP
67
Specifies whether the Control widget should have autorepeat behavior.
68
If set to be "true", the value of the Control widget will be
69
automatically incremented or decremented when the user holds down the
70
mouse button over the arrow buttons. Only values "true" and
71
"false" will be recognized.
72
'----------END
73
'
74
'
75
'----------BEGIN
76
.LP
77
.nf
78
Name:           \fBcommand\fR
79
Class:          \fBCommand\fR
80
Switch:         \fB\-command\fR
81
.fi
82
.IP
83
Specifies the command to be called when the \fB\-value\fR option of
84
the Control widget is changed.  The command will be called with one
85
arguments -- the new value of the Control widget.
86
'----------END
87
'
88
'
89
'----------BEGIN
90
.LP
91
.nf
92
Name:           \fBdecrCmd\fR
93
Class:          \fBDecrCmd\fR
94
Switch:         \fB\-decrcmd\fR
95
.fi
96
.IP
97
Specifies a TCL command to be called when the the user presses the
98
down-arrow button subwidget. This command is called with one parameter
99
-- the current \fB\-value\fR of this Control widget. This
100
command is to decrement this value by one step, according to its own
101
definition of "decrement", and return the decremented value, which
102
will be stored in the \fB\-value\fR of this Control widget.
103
'----------END
104
'
105
'----------BEGIN
106
.LP
107
.nf
108
Name:           \fBdisableCallback\fR
109
Class:          \fBDisableCallback\fR
110
Switch:         \fB\-disablecallback\fR
111
.fi
112
.IP
113
A boolean value indicating whether callbacks should be disabled. When
114
set to true, the TCL command specified by the \fB\-command\fR option
115
is not executed when the \fB\-value\fR of the Control widget
116
changes.
117
'----------END
118
'
119
'----------BEGIN
120
.LP
121
.nf
122
Name:           \fBdisableForeground\fR
123
Class:          \fBDisableForeground\fR
124
Switch:         \fB\-disableforeground\fR
125
.fi
126
.IP
127
The foreground color to use for of the entry subwidget when the
128
Control widget is disabled.
129
'----------END
130
'
131
'
132
'----------BEGIN
133
.LP
134
.nf
135
Name:           \fBincrCmd\fR
136
Class:          \fBIncrCmd\fR
137
Switch:         \fB\-incrcmd\fR
138
.fi
139
.IP
140
Specifies a TCL command to be called when the the user presses the
141
up-arrow button subwidget. This command is called with one parameter
142
-- the current \fB\-value\fR of this Control widget. This
143
command is to increment this value by one step, according to its own
144
definition of "increment", and return the incremented value, which
145
will be stored in the \fB\-value\fR of this Control widget.
146
'----------END
147
'
148
'----------BEGIN
149
.LP
150
.nf
151
Name:           \fBinitwait\fR
152
Class:          \fBInitwait\fR
153
Switch:         \fB\-initwait\fR
154
.fi
155
.IP
156
Specifies how long the Control widget should wait initially before
157
it starts to automatically increment or decrement its value in the
158
autorepeat mode. In milliseconds.
159
'----------END
160
'
161
'----------BEGIN
162
.LP
163
.nf
164
Name:           \fBinteger\fR
165
Class:          \fBInteger\fR
166
Switch:         \fB\-integer\fR
167
.fi
168
.IP
169
A Boolean value specifying whether only integer numbers are accepted.
170
'----------END
171
'
172
'----------BEGIN
173
.LP
174
.nf
175
Name:           \fBlabel\fR
176
Class:          \fBLabel\fR
177
Switch:         \fB\-label\fR
178
.fi
179
.IP
180
Specifies the string to display as the label of this Control widget.
181
'----------END
182
'
183
'----------BEGIN
184
.LP
185
.nf
186
Name:           \fBlabelSide\fR
187
Class:          \fBLabelSide\fR
188
Switch:         \fB\-labelside\fR
189
.fi
190
.IP
191
Specifies where the label should be displayed relative to the entry
192
subwidget. Valid options are: \fBtop\fR, \fBleft\fR, \fBright\fR,
193
\fBbottom\fR, \fBnone\fR or \fBacrosstop\fR.
194
'----------END
195
'
196
'
197
'----------BEGIN
198
.LP
199
.nf
200
Name:           \fBmax\fR
201
Class:          \fBMax\fR
202
Switch:         \fB\-max\fR
203
Alias:          \fB\-ulimit\fR
204
.fi
205
.IP
206
Specifies the upper limit of the value of the Control widget. When set
207
to empty string, the Control widget has no upper limit.
208
'----------END
209
''
210
'----------BEGIN
211
.LP
212
.nf
213
Name:           \fBmin\fR
214
Class:          \fBMin\fR
215
Switch:         \fB\-min\fR
216
Alias:          \fB\-llimit\fR
217
.fi
218
.IP
219
Specifies the lower limit of the value of the Control widget.When set
220
to empty string, the Control widget has no lower limit.
221
'----------END
222
'
223
'----------BEGIN
224
.LP
225
.nf
226
Name:           \fBrepeatRate\fR
227
Class:          \fBRepeatRate\fR
228
Switch:         \fB\-repeatrate\fR
229
.fi
230
.IP
231
Specifies how often the value of the Control widget should be
232
incremented or decremented when it is in the autorepeat mode. In
233
milliseconds.
234
'----------END
235
'
236
'----------BEGIN
237
.LP
238
.nf
239
Name:           \fBselectMode\fR
240
Class:          \fBSelectMode\fR
241
Switch:         \fB\-selectmode\fR
242
.fi
243
.IP
244
Specifies how the Control widget should react to \fC\fR
245
events. When set to "immediate", any user keyboard inputs will
246
immediately change the \fB\-value\fR option. When set to "normal", the
247
user keyboard inputs will be copied to the \fB\-value\fR option only
248
if the\fC \fR key is pressed or the keyboard focus is
249
changed. The use of the immediate mode is discouraged. For effective
250
use of the Control widget, one should use the normal mode together
251
with the \fBupdate\fR widget command (see below).
252
'----------END
253
'
254
'----------BEGIN
255
.LP
256
.nf
257
Name:           \fBstate\fR
258
Class:          \fBState\fR
259
Switch:         \fB\-state\fR
260
.fi
261
.IP
262
Specifies the whether the Control widget is normal or
263
disabled.  Only the values "normal" and "disabled" are recognized.
264
'----------END
265
'
266
'----------BEGIN
267
.LP
268
.nf
269
Name:           \fBstep\fR
270
Class:          \fBStep\fR
271
Switch:         \fB\-step\fR
272
.fi
273
.IP
274
Specifies by how much the value of the Control widget should be
275
incremented or decrmented when the user press the arrow buttons.
276
'----------END
277
'
278
'
279
'----------BEGIN
280
.LP
281
.nf
282
Name:           \fBvalidateCmd\fR
283
Class:          \fBValidateCmd\fR
284
Switch:         \fB\-validatecmd\fR
285
.fi
286
.IP
287
Specifies a TCL command to be called when the -value of the
288
Control widget is about to change. This command is called
289
with one parameter -- the new \fB\-value\fR entered by the user. This
290
command is to validate this new value by returning a value it deems
291
valid.
292
'----------END
293
'
294
'----------BEGIN
295
.LP
296
.nf
297
Name:           \fBvalue\fR
298
Class:          \fBValue\fR
299
Switch:         \fB\-value\fR
300
.fi
301
.IP
302
Specifies the value of the Control widget.
303
'----------END
304
'
305
'----------BEGIN
306
.LP
307
.nf
308
Name:           \fBvariable\fR
309
Class:          \fBVariable\fR
310
Switch:         \fB\-variable\fR
311
.fi
312
.IP
313
Specifies the global variable in which the value of the
314
Control widget should be stored. The value of the Control widget
315
will be automatically updated when this variable is changed.
316
'----------END
317
'
318
'----------------------------------------------------------------------
319
.SH SUBWIDGETS
320
'----------BEGIN
321
.LP
322
.nf
323
Name:           \fBdecr\fR
324
Class:          \fBButton\fR
325
.fi
326
.IP
327
The down arrow button.
328
'----------END
329
'
330
'----------BEGIN
331
.LP
332
.nf
333
Name:           \fBentry\fR
334
Class:          \fBEntry\fR
335
.fi
336
.IP
337
The entry that shows the value of this Control widget.
338
'----------END
339
'
340
'----------BEGIN
341
.LP
342
.nf
343
Name:           \fBincr\fR
344
Class:          \fBButton\fR
345
.fi
346
.IP
347
The up arrow button.
348
'----------END
349
'
350
'----------BEGIN
351
.LP
352
.nf
353
Name:           \fBlabel\fR
354
Class:          \fBLabel\fR
355
.fi
356
.IP
357
The label subwidget.
358
'----------END
359
'
360
.BE
361
'
362
'
363
'----------------------------------------------------------------------
364
.SH DESCRIPTION
365
'
366
.PP
367
'
368
The \fBtixControl\fR command creates a new window (given by the
369
\fIpathName\fR argument) and makes it into a Control widget.
370
Additional options, described above, may be specified on the command
371
line or in the option database to configure aspects of the
372
Control widget such as its cursor and relief.
373
 
374
The Control widget is also known as the \fBSpinBox\fR widget.
375
It is generally used to control a value. The user can adjust the value
376
by pressing the two arrow buttons or by entering the value directly
377
into the entry. The new value will be checked against the user-defined
378
upper and lower limits.
379
'
380
'
381
'----------------------------------------------------------------------
382
.SH WIDGET COMMANDS
383
.PP
384
'
385
The \fBtixControl\fR command creates a new Tcl command whose name is
386
the same as the path name of the Control widget's window.  This
387
command may be used to invoke various operations on the widget. It has
388
the following general form:
389
'
390
.DS C
391
'
392
\fIpathName option \fR?\fIarg arg ...\fR?
393
.PP
394
.DE
395
'
396
\fIPathName\fR is the name of the command, which is the same as the
397
Control widget's path name.  \fIOption\fR and the \fIarg\fRs
398
determine the exact behavior of the command.  The following commands
399
are possible for Control widgets:
400
'
401
.TP
402
\fIpathName \fBcget\fR \fIoption\fR
403
'
404
Returns the current value of the configuration option given by
405
\fIoption\fR. \fIOption\fR may have any of the values accepted by the
406
\fBtixControl\fR command.
407
'
408
'
409
.TP
410
'
411
\fIpathName \fBconfigure\fR ?\fIoption\fR? \fI?value option value ...\fR?
412
'
413
Query or modify the configuration options of the widget.  If no
414
\fIoption\fR is specified, returns a list describing all of the
415
available options for \fIpathName\fR (see \fBTk_ConfigureInfo\fR for
416
information on the format of this list).  If \fIoption\fR is specified
417
with no \fIvalue\fR, then the command returns a list describing the
418
one named option (this list will be identical to the corresponding
419
sublist of the value returned if no \fIoption\fR is specified).  If
420
one or more \fIoption\-value\fR pairs are specified, then the command
421
modifies the given widget option(s) to have the given value(s); in
422
this case the command returns an empty string.  \fIOption\fR may have
423
any of the values accepted by the \fBtixControl\fR command.
424
'
425
.TP
426
\fIpathName \fBdecr\fR
427
'
428
Decrements the value of the Control widget by the step specified
429
by the \fI\-step\fR option.
430
'
431
'
432
.TP
433
\fIpathName \fBincr\fR
434
'
435
Increments the value of the Control widget by the step
436
specified by the \fI\-step\fR option.
437
'
438
'
439
.TP
440
\fIpathName \fBinvoke\fR
441
'
442
Causes the command specified by the \fI\-command\fR option to be
443
invoked.
444
'
445
.TP
446
\fIpathName \fBupdate\fR
447
'
448
If the user has modified the entry using keyboard inputs, the update
449
command will \fBupdate\fR the \fB\-value\fR of this Control
450
widget. When the Control widget's \fB\-selectmode\fR option is set to
451
"normal", one should call the \fBupdate\fR command on this widget
452
before examining its \fB\-value\fR option. This command has no effect
453
in if the \fB\-selectmode\fR option is set to "immediate".
454
'
455
.TP
456
\fIpathName \fBsubwidget \fI name ?args?\fR
457
'
458
When no options are given, this command returns the pathname of the
459
subwidget of the specified name.
460
 
461
When options are given, the widget command of the specified subwidget
462
will be called with these options.
463
'
464
'
465
'
466
'----------------------------------------------------------------------
467
.SH BINDINGS
468
.PP
469
'
470
When the user presses the up/down arrow buttons (or press the  and
471
 arrow keys on the keyboard), the value of the tixControl widget
472
is adjusted according to the \fB\-validatecmd\fR, \fB\-incrcmd\fR,
473
\fB\-decrcmd\fR, \fB\-step\fR, \fB\-max\fR and \fB\-min\fR options.
474
'
475
'
476
'----------------------------------------------------------------------
477
.SH KEYWORDS
478
Tix(n)

powered by: WebSVN 2.1.0

© copyright 1999-2024 OpenCores.org, equivalent to Oliscience, all rights reserved. OpenCores®, registered trademark.