OpenCores
URL https://opencores.org/ocsvn/pltbutils/pltbutils/trunk

Subversion Repositories pltbutils

Compare Revisions

  • This comparison shows the changes necessary to convert path
    /pltbutils/trunk/src/vhdl
    from Rev 34 to Rev 35
    Reverse comparison

Rev 34 → Rev 35

/pltbutils_user_cfg_pkg.vhd
54,10 → 54,9
library ieee;
use ieee.std_logic_1164.all;
use ieee.numeric_std.all;
use std.textio.all;
--use std.textio.all;
--use std.env.all; -- Uncomment if using stop or finish in custom_stopsim() below.
use work.txt_util.all;
use work.pltbutils_type_pkg.all; -- Use for VHDL-2002 protected types, comment out for VHDL-93
 
package pltbutils_user_cfg_pkg is
 
81,6 → 80,10
--- Procedure declarations ---
-- The user should NOT modify these.
procedure custom_stopsim(
constant timestamp : in time
);
procedure custom_startsim_msg(
constant testcase_name : in string;
constant timestamp : in time
111,6 → 114,7
procedure custom_check_msg(
constant rpt : in string;
constant timestamp : in time;
constant expr : in boolean;
constant actual : in string;
constant expected : in string;
128,11 → 132,7
constant test_name : in string;
constant err_cnt_in_test : in integer
);
procedure custom_stopsim(
constant timestamp : in time
);
--- User's function and procedure declarations ---
-- Example for use with TeamCity. Remove, modify or replace
-- to suit other other continous integration tools or scripts, if you need to.
147,6 → 147,29
--- Procedure definitions ---
-- The user should NOT modify the arguments,
-- but the behaviour is free to modify to fit the user's requirements.
procedure custom_stopsim(
constant timestamp : in time
) is
begin
-- The best way to stop a simulation differs between different simulators.
-- Below are some examples. Modify to suit your simulator.
-- Works with some simulators that supports VHDL-2008.
-- Requires that 'use std.env.all' at the top of the file is uncommented.
--stop;
-- Works with some simulators that support VHDL-2008.
-- Requires that 'use std.env.all' at the top of the file is uncommented.
--finish;
-- Works in all simulators known by the author, but ugly.
assert false
report "--- FORCE END OF SIMULATION ---" &
" (ignore this false failure message, it's not a real failure)"
severity failure;
end procedure custom_stopsim;
 
-- Example custom messages for TeamCity.
-- Edit to suit other continous integration tools or scripts, if you need to.
199,6 → 222,7
 
procedure custom_check_msg(
constant rpt : in string;
constant timestamp : in time;
constant expr : in boolean;
constant actual : in string;
constant expected : in string;
264,29 → 288,6
end if;
end procedure custom_error_msg;
procedure custom_stopsim(
constant timestamp : in time
) is
begin
-- The best way to stop a simulation differs between different simulators.
-- Below are some examples. Modify to suit your simulator.
-- Works with some simulators.
-- Requires that 'use std.env.all' at the top of the file is uncommented.
--stop; -- VHDL-2008
-- Works with some simulators.
-- Requires that 'use std.env.all' at the top of the file is uncommented.
--finish; -- VHDL-2008
-- Works in all simulators known by the author, but ugly.
assert false
report "--- FORCE END OF SIMULATION ---" &
" (ignore this false failure message, it's not a real failure)"
severity failure;
end procedure custom_stopsim;
 
--- User's function and procedure definitions ---
-- Example for use with TeamCity. Remove, modify or replace
-- to suit other other continous integration tools or scripts, if you need to.