NET "I0/clk15M1" TNM_NET = "I0/clk15M1";
TIMESPEC "TS_I0_clk15M1" = PERIOD "I0/clk15M1" 66.666666 ns HIGH 50 %;
NET "clkin" TNM_NET = "clkin";
TIMESPEC "TS_clkin" = PERIOD "clkin" 22.222222 ns HIGH 50 %;
NET "I0/clk60M1" TNM_NET = "I0/clk60M1";
TIMESPEC "TS_I0_clk60M1" = PERIOD "I0/clk60M1" 16.666666 ns HIGH 50 %;
NET "I0/clk45M1" TNM_NET = "I0/clk45M1";
TIMESPEC "TS_I0_clk45M1" = PERIOD "I0/clk45M1" 22.222222 ns HIGH 50 %;
NET "spi_clk" TNM_NET = "spi_clk";
TIMESPEC "TS_spi_clk" = PERIOD "spi_clk" 50 ns HIGH 50 %;
NET "clkin" LOC = "P127";
NET "pixelclock" LOC = "P128";
NET "digitalvideo<0>" LOC = "P108";
NET "digitalvideo<1>" LOC = "P107";
NET "digitalvideo<2>" LOC = "P112";
NET "digitalvideo<3>" LOC = "P113";
NET "digitalvideo<4>" LOC = "P116";
NET "digitalvideo<5>" LOC = "P118";
NET "digitalvideo<6>" LOC = "P119";
NET "digitalvideo<7>" LOC = "P122";
NET "digitalvideo<8>" LOC = "P123";
NET "digitalvideo<9>" LOC = "P129";
NET "reset" LOC = "P105";
NET "spi_ss" LOC = "P102";
NET "spi_clk" LOC = "P125";
NET "spi_data" LOC = "P104";
NET "spi_cd" LOC = "P103";
NET "ram_adr<0>" LOC = "P77";
NET "ram_adr<1>" LOC = "P74";
NET "ram_adr<2>" LOC = "P70";
NET "ram_adr<3>" LOC = "P68";
NET "ram_adr<4>" LOC = "P60";
NET "ram_adr<5>" LOC = "P52";
NET "ram_adr<6>" LOC = "P50";
NET "ram_adr<7>" LOC = "P46";
NET "ram_adr<8>" LOC = "P41";
NET "ram_adr<9>" LOC = "P40";
NET "ram_adr<10>" LOC = "P44";
NET "ram_adr<11>" LOC = "P47";
NET "ram_adr<12>" LOC = "P51";
NET "ram_adr<13>" LOC = "P53";
NET "ram_adr<14>" LOC = "P57";
NET "ram_adr<15>" LOC = "P63";
NET "ram_adr<16>" LOC = "P69";
NET "ram_adr<17>" LOC = "P73";
NET "ram_adr<18>" LOC = "P76";
NET "ram_data<0>" LOC = "P23";
NET "ram_data<1>" LOC = "P24";
NET "ram_data<2>" LOC = "P25";
NET "ram_data<3>" LOC = "P26";
NET "ram_data<4>" LOC = "P17";
NET "ram_data<5>" LOC = "P18";
NET "ram_data<6>" LOC = "P20";
NET "ram_data<7>" LOC = "P21";
NET "ram_data<8>" LOC = "P32";
NET "ram_data<9>" LOC = "P33";
NET "ram_data<10>" LOC = "P35";
NET "ram_data<11>" LOC = "P36";
NET "ram_data<12>" LOC = "P27";
NET "ram_data<13>" LOC = "P28";
NET "ram_data<14>" LOC = "P30";
NET "ram_data<15>" LOC = "P31";
NET "ram_wr" LOC = "P55";
NET "ram_rd" LOC = "P59";
NET "ram_cs" LOC = "P56";