URL
https://opencores.org/ocsvn/openrisc/openrisc/trunk
Subversion Repositories openrisc
[/] [openrisc/] [trunk/] [gnu-old/] [gcc-4.2.2/] [gcc/] [testsuite/] [ada/] [acats/] [tests/] [c4/] [c45622a.ada] - Rev 816
Compare with Previous | Blame | View Log
-- C45622A.ADA -- Grant of Unlimited Rights -- -- Under contracts F33600-87-D-0337, F33600-84-D-0280, MDA903-79-C-0687, -- F08630-91-C-0015, and DCA100-97-D-0025, the U.S. Government obtained -- unlimited rights in the software and documentation contained herein. -- Unlimited rights are defined in DFAR 252.227-7013(a)(19). By making -- this public release, the Government intends to confer upon all -- recipients unlimited rights equal to those held by the Government. -- These rights include rights to use, duplicate, release or disclose the -- released technical data and computer software in whole or in part, in -- any manner and for any purpose whatsoever, and to have or permit others -- to do so. -- -- DISCLAIMER -- -- ALL MATERIALS OR INFORMATION HEREIN RELEASED, MADE AVAILABLE OR -- DISCLOSED ARE AS IS. THE GOVERNMENT MAKES NO EXPRESS OR IMPLIED -- WARRANTY AS TO ANY MATTER WHATSOEVER, INCLUDING THE CONDITIONS OF THE -- SOFTWARE, DOCUMENTATION OR OTHER INFORMATION RELEASED, MADE AVAILABLE -- OR DISCLOSED, OR THE OWNERSHIP, MERCHANTABILITY, OR FITNESS FOR A -- PARTICULAR PURPOSE OF SAID MATERIAL. --* -- OBJECTIVE: -- FOR EXPONENTIATION OF FLOATING POINT TYPES, CHECK THAT -- CONSTRAINT_ERROR IS RAISED IF -- MACHINE_OVERFLOWS IS TRUE AND THE RESULT IS OUTSIDE THE RANGE OF -- THE BASE TYPE. THIS TESTS DIGITS 5. -- *** NOTE: This test has been modified since ACVC version 1.11 to -- 9X -- *** remove incompatibilities associated with the transition -- 9X -- *** to Ada 9X. -- 9X -- *** -- 9X -- HISTORY: -- BCB 02/09/88 CREATED ORIGINAL TEST. -- MRM 03/30/93 REMOVED NUMERIC_ERROR FOR 9X COMPATIBILITY WITH REPORT; USE REPORT; PROCEDURE C45622A IS TYPE FLT IS DIGITS 5; F : FLT; FUNCTION EQUAL_FLT (ONE, TWO : FLT) RETURN BOOLEAN IS BEGIN RETURN ONE = TWO * FLT (IDENT_INT(1)); END EQUAL_FLT; BEGIN TEST ("C45622A", "FOR EXPONENTIATION OF FLOATING POINT TYPES, " & "CHECK THAT CONSTRAINT_ERROR " & "IS RAISED IF MACHINE_OVERFLOWS IS TRUE AND " & "THE RESULT IS OUTSIDE THE RANGE OF THE BASE " & "TYPE. THIS TESTS DIGITS 5"); IF FLT'MACHINE_OVERFLOWS THEN BEGIN F := (FLT'BASE'LAST)**IDENT_INT (2); FAILED ("CONSTRAINT_ERROR WAS NOT RAISED FOR " & "EXPONENTIATION"); IF NOT EQUAL_FLT(F,F) THEN COMMENT ("DON'T OPTIMIZE F"); END IF; EXCEPTION WHEN CONSTRAINT_ERROR => COMMENT ("CONSTRAINT_ERROR WAS RAISED FOR " & "EXPONENTIATION"); WHEN OTHERS => FAILED ("AN EXCEPTION OTHER THAN CONSTRAINT_ERROR " & "WAS RAISED FOR EXPONENTIATION"); END; ELSE NOT_APPLICABLE ("THIS TEST IS NOT APPLICABLE DUE TO " & "MACHINE_OVERFLOWS BEING FALSE"); END IF; RESULT; END C45622A;