URL
https://opencores.org/ocsvn/openrisc_2011-10-31/openrisc_2011-10-31/trunk
Subversion Repositories openrisc_2011-10-31
[/] [openrisc/] [trunk/] [gnu-src/] [gcc-4.5.1/] [gcc/] [testsuite/] [ada/] [acats/] [tests/] [c9/] [c940013.a] - Rev 294
Compare with Previous | Blame | View Log
-- C940013.A
--
-- Grant of Unlimited Rights
--
-- Under contracts F33600-87-D-0337, F33600-84-D-0280, MDA903-79-C-0687,
-- F08630-91-C-0015, and DCA100-97-D-0025, the U.S. Government obtained
-- unlimited rights in the software and documentation contained herein.
-- Unlimited rights are defined in DFAR 252.227-7013(a)(19). By making
-- this public release, the Government intends to confer upon all
-- recipients unlimited rights equal to those held by the Government.
-- These rights include rights to use, duplicate, release or disclose the
-- released technical data and computer software in whole or in part, in
-- any manner and for any purpose whatsoever, and to have or permit others
-- to do so.
--
-- DISCLAIMER
--
-- ALL MATERIALS OR INFORMATION HEREIN RELEASED, MADE AVAILABLE OR
-- DISCLOSED ARE AS IS. THE GOVERNMENT MAKES NO EXPRESS OR IMPLIED
-- WARRANTY AS TO ANY MATTER WHATSOEVER, INCLUDING THE CONDITIONS OF THE
-- SOFTWARE, DOCUMENTATION OR OTHER INFORMATION RELEASED, MADE AVAILABLE
-- OR DISCLOSED, OR THE OWNERSHIP, MERCHANTABILITY, OR FITNESS FOR A
-- PARTICULAR PURPOSE OF SAID MATERIAL.
--*
--
-- OBJECTIVE:
-- Check that items queued on a protected entry are handled FIFO and that
-- the 'count attribute of that entry reflects the length of the queue.
--
-- TEST DESCRIPTION:
-- Use a small subset of the freeway ramp simulation shown in other
-- tests. With the timing pulse off (which prevents items from being
-- removed from the queue) queue up a small number of calls. Start the
-- timing pulse and, at the first execution of the entry code, check the
-- 'count attribute. Empty the queue. Pass the items being removed from
-- the queue to the Ramp_Sensor_01 task; there check that the items are
-- arriving in FIFO order. Check the final 'count value
--
-- Send another batch of items at a rate which will, if the delay timing
-- of the implementation is reasonable, cause the queue length to
-- fluctuate in both directions. Again check that all items arrive
-- FIFO. At the end check that the 'count returned to zero reflecting
-- the empty queue.
--
--
-- CHANGE HISTORY:
-- 06 Dec 94 SAIC ACVC 2.0
--
--!
with Report;
with ImpDef;
with Ada.Calendar;
procedure C940013 is
TC_Failed_1 : Boolean := false;
begin
Report.Test ("C940013", "Check that queues on protected entries are " &
"handled FIFO and that 'count is correct");
declare -- encapsulate the test
function "+" (Left : Ada.Calendar.Time; Right: Duration)
return Ada.Calendar.Time renames Ada.Calendar."+";
-- Weighted load given to each potential problem area and accumulated
type Load_Factor is range 0..8;
Clear_Level : constant Load_Factor := 0;
Minimum_Level : constant Load_Factor := 1;
Moderate_Level : constant Load_Factor := 2;
Serious_Level : constant Load_Factor := 4;
Critical_Level : constant Load_Factor := 6;
TC_Expected_Passage_Total : constant integer := 624;
-- For this test give each vehicle an integer ID incremented
-- by one for each successive vehicle. In reality this would be
-- a more complex alpha-numeric ID assigned at pickup time.
type Vehicle_ID is range 1..5000;
Next_ID : Vehicle_ID := Vehicle_ID'first;
-- In reality this would be about 5 seconds. The default value of
-- this constant in the implementation defined package is similar
-- but could, of course be considerably different - it would not
-- affect the test
--
Pulse_Time_Delta : duration := ImpDef.Clear_Ready_Queue;
task Pulse_Task; -- task to generate a pulse for each ramp
-- Carrier task. One is created for each vehicle arriving at the ramp
task type Vehicle is
entry Get_ID (Input_ID : in Vehicle_ID);
end Vehicle;
type acc_Vehicle is access Vehicle;
task Ramp_Sensor_01 is
entry Accept_Vehicle (Input_ID : in Vehicle_ID);
entry TC_First_Three_Handled;
entry TC_All_Done;
end Ramp_Sensor_01;
protected Pulse_State is
procedure Start_Pulse;
procedure Stop_Pulse;
function Pulsing return Boolean;
private
State : Boolean := false; -- start test will pulse off
end Pulse_State;
protected body Pulse_State is
procedure Start_Pulse is
begin
State := true;
end Start_Pulse;
procedure Stop_Pulse is
begin
State := false;
end Stop_Pulse;
function Pulsing return Boolean is
begin
return State;
end Pulsing;
end Pulse_State;
--================================================================
protected Test_Ramp is
function Meter_in_use_State return Boolean;
procedure Time_Pulse_Received;
entry Wait_at_Meter;
procedure TC_Passage (Pass_Point : Integer);
function TC_Get_Passage_Total return integer;
function TC_Get_Count return integer;
private
Release_One_Vehicle : Boolean := false;
-- For this test have Meter_in_Use already set
Meter_in_Use : Boolean := true;
TC_Wait_at_Meter_First : Boolean := true;
TC_Entry_Queue_Count : integer := 0; -- 'count of Wait_at_Meter
TC_Passage_Total : integer := 0;
TC_Pass_Point_WAM : integer := 23;
end Test_Ramp;
--================================================================
protected body Test_Ramp is
-- External call for Meter_in_Use
function Meter_in_Use_State return Boolean is
begin
return Meter_in_Use;
end Meter_in_Use_State;
-- Trace the paths through the various routines by totalling the
-- weighted call parameters
procedure TC_Passage (Pass_Point : Integer) is
begin
TC_Passage_Total := TC_Passage_Total + Pass_Point;
end TC_Passage;
-- For the final check of the whole test
function TC_Get_Passage_Total return integer is
begin
return TC_Passage_Total;
end TC_Get_Passage_Total;
function TC_Get_Count return integer is
begin
return TC_Entry_Queue_Count;
end TC_Get_Count;
-- Here each Vehicle task queues itself awaiting release
--
entry Wait_at_Meter when Release_One_Vehicle is
-- EXAMPLE OF ENTRY WITH BARRIERS AND PERSISTENT SIGNAL
begin
--
TC_Passage ( TC_Pass_Point_WAM ); -- note passage
-- For this test three vehicles are queued before the first
-- is released. If the queueing mechanism is working correctly
-- the first time we pass through here the entry'count should
-- reflect this
if TC_Wait_at_Meter_First then
if Wait_at_Meter'count /= 2 then
TC_Failed_1 := true;
end if;
TC_Wait_at_Meter_First := false;
end if;
TC_Entry_Queue_Count := Wait_at_Meter'count; -- note for later
Release_One_Vehicle := false; -- Consume the signal
null; -- stub ::: Decrement count of number of vehicles on ramp
end Wait_at_Meter;
procedure Time_Pulse_Received is
Load : Load_factor := Minimum_Level; -- for this version of the
Freeway_Breakdown : Boolean := false; -- test, freeway is Minimum
begin
-- if broken down, no vehicles are released
if not Freeway_Breakdown then
if Load < Moderate_Level then
Release_One_Vehicle := true;
end if;
null; -- stub ::: If other levels, release every other
-- pulse, every third pulse etc.
end if;
end Time_Pulse_Received;
end Test_Ramp;
--================================================================
-- Simulate the arrival of a vehicle at the Ramp_Receiver and the
-- generation of an accompanying carrier task
procedure New_Arrival is
Next_Vehicle_Task: acc_Vehicle := new Vehicle;
TC_Pass_Point : constant integer := 3;
begin
Next_ID := Next_ID + 1;
Next_Vehicle_Task.Get_ID(Next_ID);
Test_Ramp.TC_Passage ( TC_Pass_Point ); -- Note passage through here
null;
end New_arrival;
-- Carrier task. One is created for each vehicle arriving at the ramp
task body Vehicle is
This_ID : Vehicle_ID;
TC_Pass_Point_2 : constant integer := 21;
begin
accept Get_ID (Input_ID : in Vehicle_ID) do
This_ID := Input_ID;
end Get_ID;
if Test_Ramp.Meter_in_Use_State then
Test_Ramp.TC_Passage ( TC_Pass_Point_2 ); -- note passage
null; -- stub::: Increment count of number of vehicles on ramp
Test_Ramp.Wait_at_Meter; -- Queue on the meter entry
end if;
-- Call to the first in the series of the Ramp_Sensors
-- this "passes" the vehicle from one sensor to the next
-- Each sensor will requeue the call to the next thus this
-- rendezvous will only be completed as the vehicle is released
-- by the last sensor on the ramp.
Ramp_Sensor_01.Accept_Vehicle (This_ID);
exception
when others =>
Report.Failed ("Unexpected exception in Vehicle Task");
end Vehicle;
task body Ramp_Sensor_01 is
TC_Pass_Point : constant integer := 31;
This_ID : Vehicle_ID;
TC_Last_ID : Vehicle_ID := Vehicle_ID'first;
begin
loop
select
accept Accept_Vehicle (Input_ID : in Vehicle_ID) do
null; -- stub:::: match up with next Real-Time notification
-- from the sensor. Requeue to next ramp sensor
This_ID := Input_ID;
-- The following is all Test_Control code
Test_Ramp.TC_Passage ( TC_Pass_Point ); -- note passage
-- The items arrive in the order they are taken from
-- the Wait_at_Meter entry queue
if ( This_ID - TC_Last_ID ) /= 1 then
-- The tasks are being queued (or unqueued) in the
-- wrong order
Report.Failed
("Queueing on the Wait_at_Meter queue failed");
end if;
TC_Last_ID := This_ID; -- for the next check
if TC_Last_ID = 4 then
-- rendezvous with the test driver
accept TC_First_Three_Handled;
elsif TC_Last_ID = 9 then
-- rendezvous with the test driver
accept TC_All_Done;
end if;
end Accept_Vehicle;
or
terminate;
end select;
end loop;
exception
when others =>
Report.Failed ("Unexpected exception in Ramp_Sensor_01");
end Ramp_Sensor_01;
-- Task transmits a synchronizing "pulse" to all ramps
--
task body Pulse_Task is
Pulse_Time : Ada.Calendar.Time;
begin
While not Pulse_State.Pulsing loop
-- Starts up in the quiescent state
delay ImpDef.Minimum_Task_Switch;
end loop;
Pulse_Time := Ada.Calendar.Clock;
While Pulse_State.Pulsing loop
delay until Pulse_Time;
Test_Ramp. Time_Pulse_Received; -- Transmit pulse to test_ramp
-- :::::::::: and to all the other ramps
Pulse_Time := Pulse_Time + Pulse_Time_Delta; -- calculate next
end loop;
exception
when others =>
Report.Failed ("Unexpected exception in Pulse_Task");
end Pulse_Task;
begin -- declare
-- Test driver. This is ALL test control code
-- Arrange to queue three vehicles on the Wait_at_Meter queue. The
-- timing pulse is quiescent so the queue will build
for i in 1..3 loop
New_Arrival;
end loop;
delay Pulse_Time_Delta; -- ensure all is settled
Pulse_State.Start_Pulse; -- Start the timing pulse, the queue will
-- be serviced
-- wait here until the first three are complete
Ramp_Sensor_01.TC_First_Three_Handled;
if Test_Ramp.TC_Get_Count /= 0 then
Report.Failed ("Intermediate Wait_at_Entry'count is incorrect");
end if;
-- generate new arrivals at a rate that will make the queue increase
-- and decrease "randomly"
for i in 1..5 loop
New_Arrival;
delay Pulse_Time_Delta/2;
end loop;
-- wait here till all have been handled
Ramp_Sensor_01.TC_All_Done;
if Test_Ramp.TC_Get_Count /= 0 then
Report.Failed ("Final Wait_at_Entry'count is incorrect");
end if;
Pulse_State.Stop_Pulse; -- finish test
if TC_Expected_Passage_Total /= Test_Ramp.TC_Get_Passage_Total then
Report.Failed ("Unexpected paths taken");
end if;
end; -- declare
if TC_Failed_1 then
Report.Failed ("Wait_at_Meter'count incorrect");
end if;
Report.Result;
end C940013;