URL
https://opencores.org/ocsvn/openrisc_me/openrisc_me/trunk
Subversion Repositories openrisc_me
[/] [openrisc/] [trunk/] [gnu-src/] [gcc-4.5.1/] [gcc/] [testsuite/] [ada/] [acats/] [tests/] [c9/] [c954a03.a] - Rev 294
Compare with Previous | Blame | View Log
-- C954A03.A
--
-- Grant of Unlimited Rights
--
-- Under contracts F33600-87-D-0337, F33600-84-D-0280, MDA903-79-C-0687,
-- F08630-91-C-0015, and DCA100-97-D-0025, the U.S. Government obtained
-- unlimited rights in the software and documentation contained herein.
-- Unlimited rights are defined in DFAR 252.227-7013(a)(19). By making
-- this public release, the Government intends to confer upon all
-- recipients unlimited rights equal to those held by the Government.
-- These rights include rights to use, duplicate, release or disclose the
-- released technical data and computer software in whole or in part, in
-- any manner and for any purpose whatsoever, and to have or permit others
-- to do so.
--
-- DISCLAIMER
--
-- ALL MATERIALS OR INFORMATION HEREIN RELEASED, MADE AVAILABLE OR
-- DISCLOSED ARE AS IS. THE GOVERNMENT MAKES NO EXPRESS OR IMPLIED
-- WARRANTY AS TO ANY MATTER WHATSOEVER, INCLUDING THE CONDITIONS OF THE
-- SOFTWARE, DOCUMENTATION OR OTHER INFORMATION RELEASED, MADE AVAILABLE
-- OR DISCLOSED, OR THE OWNERSHIP, MERCHANTABILITY, OR FITNESS FOR A
-- PARTICULAR PURPOSE OF SAID MATERIAL.
--*
--
-- OBJECTIVE:
-- Check that a requeue statement in an accept_statement with
-- parameters may requeue the entry call to a protected entry with no
-- parameters. Check that, if the call is queued on the new entry's
-- queue, the original caller remains blocked after the requeue, but
-- the accept_statement containing the requeue is completed.
--
-- Note that this test uses a requeue "with abort," although it does not
-- check that such a requeued caller can be aborted; that feature is
-- tested elsewhere.
--
-- TEST DESCRIPTION:
-- Declare a protected type which simulates a printer device driver
-- (foundation code).
--
-- Declare a task which simulates a printer server for multiple printers.
--
-- For the protected type, declare an entry with a barrier that is set
-- false by a protected procedure (which simulates starting a print job
-- on the printer), and is set true by a second protected procedure (which
-- simulates a handler called when the printer interrupts, indicating
-- that printing is done).
--
-- For the task, declare an entry whose corresponding accept statement
-- contains a call to first protected procedure of the protected type
-- (which sets the barrier of the protected entry to false), followed by
-- a requeue with abort to the protected entry. Declare a second entry
-- which does nothing.
--
-- Declare a "requesting" task which calls the printer server task entry
-- (and thus executes the requeue). Verify that, following the requeue,
-- the requesting task remains blocked. Call the second entry of the
-- printer server task (the acceptance of this entry call verifies that
-- the requeue statement completed the entry call by the requesting task.
-- Call the second protected procedure of the protected type (the
-- interrupt handler) and verify that the protected entry completes for
-- the requesting task (which verifies that the requeue statement queued
-- the first task object to the protected entry).
--
-- TEST FILES:
-- This test depends on the following foundation code:
--
-- F954A00.A
--
--
-- CHANGE HISTORY:
-- 06 Dec 94 SAIC ACVC 2.0
-- 10 Oct 96 SAIC Added pragma elaborate.
--
--!
package C954A03_0 is -- Printer server abstraction.
-- Simulate a system with multiple printers. The entry Print requests
-- that data be printed on the next available printer. The entry call
-- is accepted when a printer is available, and completes when printing
-- is done.
task Printer_Server is
entry Print (File_Name : String); -- Test the requeue statement.
entry Verify_Results; -- Artifice for test purposes.
end Printer_Server;
end C954A03_0;
--==================================================================--
with Report;
with ImpDef;
with F954A00; -- Printer device abstraction.
use F954A00;
pragma Elaborate(F954a00);
package body C954A03_0 is -- Printer server abstraction.
task body Printer_Server is
Printers_Busy : Boolean := True;
Index : Printer_ID := 1;
Print_Accepted : Boolean := False;
begin
loop
-- Wait for a printer to become available:
while Printers_Busy loop
Printers_Busy := False; -- Exit loop if
-- entry accepted.
select
Printer(Index).Done_Printing; -- Accepted immed.
-- when printer is
-- available.
else
Index := 1 + (Index mod Number_Of_Printers);-- Entry not immed.
Printers_Busy := True; -- accepted; keep
end select; -- looping.
-- Allow other tasks to get control
delay ImpDef.Minimum_Task_Switch;
end loop;
-- Value of Index
-- at loop exit
-- identifies the
-- avail. printer.
-- Wait for a print request or terminate:
select
accept Print (File_Name : String) do
Print_Accepted := True; -- Allow
-- Verify_Results
-- to be accepted.
Printer(Index).Start_Printing (File_Name); -- Begin printing on
-- the available
-- -- -- printer.
-- Requeue is tested here --
-- --
-- Requeue caller so
requeue Printer(Index).Done_Printing -- server task free
with abort; -- to accept other
end Print; -- requests.
or
-- Guard ensures that Verify_Results cannot be accepted
-- until after Print has been accepted. This avoids a
-- race condition in the main program.
when Print_Accepted => accept Verify_Results; -- Artifice for
-- testing purposes.
or
terminate;
end select;
end loop;
exception
when others =>
Report.Failed ("Exception raised in Printer_Server task");
end Printer_Server;
end C954A03_0;
--==================================================================--
with Report;
with ImpDef;
with F954A00; -- Printer device abstraction.
with C954A03_0; -- Printer server abstraction.
use C954A03_0;
use F954A00;
procedure C954A03 is
Long_Enough : constant Duration := ImpDef.Clear_Ready_Queue;
--==============================================--
Task_Completed : Boolean := False; -- Testing flag.
protected Interlock is -- Artifice for test purposes.
entry Wait; -- Wait for lock to be released.
procedure Release; -- Release the lock.
private
Locked : Boolean := True;
end Interlock;
protected body Interlock is
entry Wait when not Locked is -- Calls are queued until after
-- -- Release is called.
begin
Task_Completed := True;
end Wait;
procedure Release is -- Called by Print_Request.
begin
Locked := False;
end Release;
end Interlock;
--==============================================--
task Print_Request is -- Send a print request.
end Print_Request;
task body Print_Request is
My_File : constant String := "MYFILE.DAT";
begin
Printer_Server.Print (My_File); -- Invoke requeue statement.
Interlock.Release; -- Allow main to continue.
exception
when others =>
Report.Failed ("Exception raised in Print_Request task");
end Print_Request;
--==============================================--
begin -- Main program.
Report.Test ("C954A03", "Requeue from an Accept with parameters" &
" to a Protected Entry without parameters");
-- To pass this test, the following must be true:
--
-- (A) The Print entry call made by the task Print_Request must be
-- completed by the requeue statement.
-- (B) Print_Request must remain blocked following the requeue.
-- (C) Print_Request must be queued on the Done_Printing queue of
-- Printer(1).
-- (D) Print_Request must continue execution after Done_Printing is
-- complete.
--
-- First, verify (A): that the Print entry call is complete.
--
-- Call the entry Verify_Results. If the requeue statement completed the
-- entry call to Print, the entry call to Verify_Results should be
-- accepted. Since the main will hang if this is NOT the case, make this
-- a timed entry call.
select
Printer_Server.Verify_Results; -- Accepted if requeue completed
-- entry call to Print.
or
delay Long_Enough; -- Time out otherwise.
Report.Failed ("Requeue did not complete entry call");
end select;
-- Now verify (B): that Print_Request remains blocked following the
-- requeue. Also verify that Done_Printing (the entry to which
-- Print_Request should have been queued) has not yet executed.
if Printer(1).Is_Done then
Report.Failed ("Target entry of requeue executed prematurely");
elsif Print_Request'Terminated then
Report.Failed ("Caller did not remain blocked after the requeue");
else
-- Verify (C): that Print_Request is queued on the
-- Done_Printing queue of Printer(1).
--
-- Set the barrier for Printer(1).Done_Printing to true. Check
-- that the Done flag is updated and that Print_Request terminates.
Printer(1).Handle_Interrupt; -- Simulate a printer interrupt,
-- signaling that printing is
-- done.
-- The Done_Printing entry body will complete before the next
-- protected action is called (Printer(1).Is_Done).
if not Printer(1).Is_Done then
Report.Failed ("Caller was not requeued on target entry");
end if;
-- Finally, verify (D): that Print_Request continues after Done_Printing
-- completes.
--
-- After Done_Printing completes, there is a potential race condition
-- between the main program and Print_Request. The protected object
-- Interlock is provided to ensure that the check of whether
-- Print_Request continued is made *after* it has had a chance to do so.
-- The main program waits until the statement in Print_Request following
-- the requeue-causing statement has executed, then checks to see
-- whether Print_Request did in fact continue executing.
--
-- Note that the test will hang here if Print_Request does not continue
-- executing following the completion of the requeued entry call.
Interlock.Wait; -- Wait until Print_Request is
-- done.
if not Task_Completed then
Report.Failed ("Caller remained blocked after target " &
"entry released");
end if;
-- Wait for Print_Request to finish before calling Report.Result.
while not Print_Request'Terminated loop
delay ImpDef.Minimum_Task_Switch;
end loop;
end if;
Report.Result;
end C954A03;