OpenCores
URL https://opencores.org/ocsvn/openrisc_me/openrisc_me/trunk

Subversion Repositories openrisc_me

[/] [openrisc/] [trunk/] [gnu-src/] [gcc-4.5.1/] [gcc/] [testsuite/] [ada/] [acats/] [tests/] [ce/] [ce3806h.ada] - Rev 294

Compare with Previous | Blame | View Log

-- CE3806H.ADA
 
--                             Grant of Unlimited Rights
--
--     Under contracts F33600-87-D-0337, F33600-84-D-0280, MDA903-79-C-0687,
--     F08630-91-C-0015, and DCA100-97-D-0025, the U.S. Government obtained 
--     unlimited rights in the software and documentation contained herein.
--     Unlimited rights are defined in DFAR 252.227-7013(a)(19).  By making 
--     this public release, the Government intends to confer upon all 
--     recipients unlimited rights  equal to those held by the Government.  
--     These rights include rights to use, duplicate, release or disclose the 
--     released technical data and computer software in whole or in part, in 
--     any manner and for any purpose whatsoever, and to have or permit others 
--     to do so.
--
--                                    DISCLAIMER
--
--     ALL MATERIALS OR INFORMATION HEREIN RELEASED, MADE AVAILABLE OR
--     DISCLOSED ARE AS IS.  THE GOVERNMENT MAKES NO EXPRESS OR IMPLIED 
--     WARRANTY AS TO ANY MATTER WHATSOEVER, INCLUDING THE CONDITIONS OF THE
--     SOFTWARE, DOCUMENTATION OR OTHER INFORMATION RELEASED, MADE AVAILABLE 
--     OR DISCLOSED, OR THE OWNERSHIP, MERCHANTABILITY, OR FITNESS FOR A
--     PARTICULAR PURPOSE OF SAID MATERIAL.
--*
-- OBJECTIVE:
--     CHECK THAT FIXED_IO PUT RAISES LAYOUT_ERROR WHEN THE NUMBER OF
--     CHARACTERS TO BE OUTPUT EXCEEDS THE MAXIMUM LINE LENGTH.  CHECK
--     THAT IT IS NOT RAISED, BUT RATHER NEW_LINE IS CALLED, WHEN THE
--     NUMBER DOES NOT EXCEED THE MAX, BUT WHEN ADDED TO THE CURRENT
--     COLUMN NUMBER, THE TOTAL EXCEEDS THE MAX.
 
-- APPLICABILITY CRITERIA:
--     THIS TEST IS APPLICABLE ONLY TO IMPLEMENTATIONS WHICH SUPPORT
--     TEXT FILES.
 
-- HISTORY:
--     JLH 09/15/87  CREATED ORIGINAL TEST.
 
WITH REPORT; USE REPORT;
WITH TEXT_IO; USE TEXT_IO;
WITH CHECK_FILE;
 
PROCEDURE CE3806H IS
 
BEGIN
 
     TEST ("CE3806H", "CHECK THAT FIXED_IO PUT RAISES " &
                      "LAYOUT_ERROR CORRECTLY");
 
     DECLARE
          FT : FILE_TYPE;
          TYPE FX IS DELTA 0.01 RANGE -200.0 .. 200.0;
          PACKAGE FXIO IS NEW FIXED_IO (FX);
          USE FXIO;
          INCOMPLETE : EXCEPTION;
          X : FX := 126.5;
          Y : FX := -134.0;
          Z : FX := 120.0;
 
     BEGIN
 
          BEGIN
               CREATE (FT, OUT_FILE, LEGAL_FILE_NAME);
          EXCEPTION
               WHEN USE_ERROR =>
                    NOT_APPLICABLE ("USE_ERROR RAISED ON TEXT CREATE " &
                                    "WITH OUT_FILE MODE");
                    RAISE INCOMPLETE;
               WHEN NAME_ERROR =>
                    NOT_APPLICABLE ("NAME_ERROR RAISED ON TEXT " &
                                    "CREATE WITH OUT_FILE MODE");
                    RAISE INCOMPLETE;
          END;
 
          SET_LINE_LENGTH (FT, 4);
 
          BEGIN
               PUT (FT, X, FORE => 3, AFT => 1);
               FAILED ("LAYOUT_ERROR NOT RAISED - FIXED");
          EXCEPTION
               WHEN LAYOUT_ERROR =>
                    NULL;
               WHEN OTHERS =>
                    FAILED ("WRONG EXCEPTION RAISED - FIXED");
          END;
 
          SET_LINE_LENGTH (FT,7);
 
          BEGIN
               PUT (FT, Y, FORE => 3, AFT => 2);
          EXCEPTION
               WHEN LAYOUT_ERROR =>
                    FAILED ("LAYOUT_ERROR RAISED SECOND PUT - " &
                            "FIXED");
               WHEN OTHERS =>
                    FAILED ("SOME EXCEPTION RAISED SECOND PUT - " &
                            "FIXED");
          END;
 
          BEGIN
               PUT (FT,Z, FORE => 4, AFT => 2);
               IF LINE (FT) /= 2 THEN
                    FAILED ("NEW_LINE NOT CALLED - FIXED");
               END IF;
          EXCEPTION
               WHEN LAYOUT_ERROR =>
                    FAILED ("LAYOUT_ERROR RAISED THIRD PUT - " &
                            "FIXED");
               WHEN OTHERS =>
                    FAILED ("EXCEPTION RAISED THIRD PUT - FIXED");
          END;
 
          BEGIN
               PUT (FT, "Y");
               PUT (FT, Z, FORE => 3, AFT => 0);
               NEW_LINE (FT);
               PUT (FT, "Z");
               PUT (FT, Y, FORE => 3, AFT => 2);
          EXCEPTION
               WHEN LAYOUT_ERROR =>
                    FAILED ("LAYOUT_ERROR RAISED LAST PUT - " &
                            "FIXED");
               WHEN OTHERS =>
                    FAILED ("EXCEPTION RAISED LAST PUT - FIXED ");
          END;
 
          CHECK_FILE (FT, "-134.00# 120.00#Y120.0#Z#-134.00#@%");
 
          BEGIN
               DELETE (FT);
          EXCEPTION
               WHEN USE_ERROR =>
                    NULL;
          END;
 
     EXCEPTION
          WHEN INCOMPLETE =>
               NULL;
 
     END;
 
     RESULT;
 
END CE3806H;
 

Compare with Previous | Blame | View Log

powered by: WebSVN 2.1.0

© copyright 1999-2024 OpenCores.org, equivalent to Oliscience, all rights reserved. OpenCores®, registered trademark.