OpenCores
URL https://opencores.org/ocsvn/openrisc_me/openrisc_me/trunk

Subversion Repositories openrisc_me

[/] [openrisc/] [trunk/] [gnu-src/] [gcc-4.5.1/] [gcc/] [testsuite/] [ada/] [acats/] [tests/] [cxg/] [cxg1003.a] - Rev 309

Go to most recent revision | Compare with Previous | Blame | View Log

-- CXG1003.A
--
--                             Grant of Unlimited Rights
--
--     Under contracts F33600-87-D-0337, F33600-84-D-0280, MDA903-79-C-0687,
--     F08630-91-C-0015, and DCA100-97-D-0025, the U.S. Government obtained 
--     unlimited rights in the software and documentation contained herein.
--     Unlimited rights are defined in DFAR 252.227-7013(a)(19).  By making 
--     this public release, the Government intends to confer upon all 
--     recipients unlimited rights  equal to those held by the Government.  
--     These rights include rights to use, duplicate, release or disclose the 
--     released technical data and computer software in whole or in part, in 
--     any manner and for any purpose whatsoever, and to have or permit others 
--     to do so.
--
--                                    DISCLAIMER
--
--     ALL MATERIALS OR INFORMATION HEREIN RELEASED, MADE AVAILABLE OR
--     DISCLOSED ARE AS IS.  THE GOVERNMENT MAKES NO EXPRESS OR IMPLIED 
--     WARRANTY AS TO ANY MATTER WHATSOEVER, INCLUDING THE CONDITIONS OF THE
--     SOFTWARE, DOCUMENTATION OR OTHER INFORMATION RELEASED, MADE AVAILABLE 
--     OR DISCLOSED, OR THE OWNERSHIP, MERCHANTABILITY, OR FITNESS FOR A
--     PARTICULAR PURPOSE OF SAID MATERIAL.
--*
--
-- OBJECTIVE:
--      Check that the subprograms defined in the package Text_IO.Complex_IO
--      provide correct results.  
--
-- TEST DESCRIPTION:
--      The generic package Ada.Numerics.Generic_Complex_Types is instantiated 
--      with a real type (new Float). The resulting new package is used as
--      the generic actual to package Complex_IO.
--      Two different versions of Put and Get are examined in this test, 
--      those that input/output complex data values from/to Text_IO files,
--      and those that input/output complex data values from/to strings.
--      Two procedures are defined to perform the file data manipulations;
--      one to place complex data into the file, and one to retrieve the data
--      from the file and verify its correctness.
--      Complex data is also put into string variables using the Procedure
--      Put for strings, and this data is then retrieved and reconverted into
--      complex values using the Get procedure.
--
--
-- APPLICABILITY CRITERIA: 
--      This test is only applicable to implementations that:
--         support Annex G,
--         support Text_IO and external files
--
--       
-- CHANGE HISTORY:
--      06 Dec 94   SAIC    ACVC 2.0
--      29 Dec 94   SAIC    Modified Width parameter in Get function calls.
--      16 Nov 95   SAIC    Corrected visibility problems for ACVC 2.0.1.
--      29 Sep 96   SAIC    Incorporated reviewer comments.
--
--!

with Ada.Text_IO.Complex_IO;
with Ada.Numerics.Generic_Complex_Types;
with Report;

procedure CXG1003 is
begin

   Report.Test ("CXG1003", "Check that the subprograms defined in " &
                           "the package Text_IO.Complex_IO " & 
                           "provide correct results");

   Test_for_Text_IO_Support:
   declare
      use Ada;

      Data_File     : Ada.Text_IO.File_Type;
      Data_Filename : constant String := Report.Legal_File_Name;

   begin

      -- An application creates a text file in mode Out_File, with the 
      -- intention of entering complex data into the file as appropriate.  
      -- In the event that the particular environment where the application 
      -- is running does not support Text_IO, Use_Error or Name_Error will be 
      -- raised on calls to Text_IO operations.  Either of these exceptions
      -- will be handled to produce a Not_Applicable result.

      Text_IO.Create (File => Data_File,
                      Mode => Ada.Text_IO.Out_File,
                      Name => Data_Filename);

      Test_Block:
      declare

         TC_Verbose : Boolean := False;

         type Real_Type is new Float;

         package Complex_Pack is new 
           Ada.Numerics.Generic_Complex_Types(Real_Type);

         package C_IO is new Ada.Text_IO.Complex_IO(Complex_Pack);

         use Ada.Text_IO, C_IO;
         use type Complex_Pack.Complex;

         Number_Of_Complex_Items : constant := 6;
         Number_Of_Error_Items   : constant := 2;

         TC_Complex              : Complex_Pack.Complex;
         TC_Last_Character_Read  : Positive;

         Complex_Array : array (1..Number_Of_Complex_Items) 
           of Complex_Pack.Complex := ( (3.0, 9.0),
                                        (4.0, 7.0),
                                        (5.0, 6.0),
                                        (6.0, 3.0),
                                        (2.0, 5.0),
                                        (3.0, 7.0) );


         procedure Load_Data_File (The_File : in out Text_IO.File_Type) is
            use Ada.Text_IO;
         begin
            -- This procedure does not create, open, or close the data file;
            -- The_File file object must be Open at this point.
            -- This procedure is designed to load complex data into a data 
            -- file twice, first using Text_IO, then Complex_IO.  In this
            -- first case, the complex data values are entered as strings,
            -- assuming a variety of legal formats, as provided in the 
            -- reference manual.

            Put_Line(The_File, "(3.0, 9.0)");
            Put_Line(The_File, "+4. +7.");    -- Relaxed real literal format.
            Put_Line(The_File, "(5.0 6.)");
            Put_Line(The_File, "6., 3.0");
            Put_Line(The_File, "  (  2.0  ,  5.0  )  ");
            Put_Line(The_File, "(");           -- Complex data separated over
            Put_Line(The_File, "3.0");         -- several (5) lines.
            Put_Line(The_File, " , ");        
            Put_Line(The_File, "7.0  ");
            Put_Line(The_File, ")");

            if TC_Verbose then
               Report.Comment("Complex values entered into data file using " &
                              "Text_IO, Procedure Load_Data_File");
            end if;

            -- Use the Complex_IO procedure Put to enter Complex data items
            -- into the data file.
            -- Note: Data is being entered into the file for the *second* time
            --       at this point. (Using Complex_IO here, Text_IO above)

            for i in 1..Number_Of_Complex_Items loop
               C_IO.Put(File => The_File, 
                        Item => Complex_Array(i), 
                        Fore => 1, 
                        Aft  => 1, 
                        Exp  => 0);
            end loop;

            if TC_Verbose then
               Report.Comment("Complex values entered into data file using " &
                              "Complex_IO, Procedure Load_Data_File");
            end if;

            Put_Line(The_File, "(5A,3)");      -- data to raise Data_Error.
            Put_Line(The_File, "(3.0,,8.0)");  -- data to raise Data_Error.

         end Load_Data_File;



         procedure Process_Data_File (The_File : in out Text_IO.File_Type) is
             TC_Complex : Complex_Pack.Complex := (0.0, 0.0);
             TC_Width   : Integer := 0;
         begin
            -- This procedure does not create, open, or close the data file;
            -- The_File file object must be Open at this point.
            -- Use procedure Get (for Files) to extract the complex data from
            -- the Text_IO file.  This data was placed into the file using
            -- Text_IO.


            for i in 1..Number_Of_Complex_Items loop
           
               C_IO.Get(The_File, TC_Complex, TC_Width);

               if TC_Complex /= Complex_Array(i) then
                  Report.Failed("Incorrect complex data read from file " &
                                "when using Text_IO procedure Get, "     &
                                "data item #" & Integer'Image(i));
               end if;
            end loop;

            if TC_Verbose then
               Report.Comment("First set of complex values extracted " &
                              "from data file using Complex_IO, "      &
                              "Procedure Process_Data_File");
            end if;

            -- Use procedure Get (for Files) to extract the complex data from
            -- the Text_IO file.  This data was placed into the file using
            -- procedure Complex_IO.Put.
            -- Note: Data is being extracted from the file for the *second*
            --       time at this point (Using Complex_IO here, Text_IO above)

            for i in 1..Number_Of_Complex_Items loop
    
               C_IO.Get(The_File, TC_Complex, TC_Width);
          
               if TC_Complex /= Complex_Array(i) then
                  Report.Failed("Incorrect complex data read from file " &
                                "when using Complex_IO procedure Get, "  &
                                "data item #" & Integer'Image(i));
               end if;
            end loop;

            if TC_Verbose then
               Report.Comment("Second set of complex values extracted " &
                              "from data file using Complex_IO, "       &
                              "Procedure Process_Data_File");
            end if;

            -- The final items in the Data_File are complex values with 
            -- incorrect syntax, which should raise Data_Error on an attempt
            -- to read them from the file.
            TC_Width := 10;
            for i in 1..Number_Of_Error_Items loop
               begin
                  C_IO.Get(The_File, TC_Complex, TC_Width);
                  Report.Failed
                    ("Exception Data_Error not raised when Complex_IO.Get " &
                     "was used to read complex data with incorrect "        &
                     "syntax from the Data_File, data item #"               &
                     Integer'Image(i));
               exception
                  when Ada.Text_IO.Data_Error => -- OK, expected exception.
                     Text_IO.Skip_Line(The_File);
                  when others =>
                     Report.Failed
                       ("Unexpected exception raised when Complex_IO.Get " &
                        "was used to read complex data with incorrect "    &
                        "syntax from the Data_File, data item #"           &
                         Integer'Image(i));
               end;
            end loop;

            if TC_Verbose then
               Report.Comment("Erroneous set of complex values extracted " &
                              "from data file using Complex_IO, "          &
                              "Procedure Process_Data_File");
            end if;


         exception
            when others =>
              Report.Failed
                ("Unexpected exception raised in Process_Data_File");
         end Process_Data_File;



      begin  -- Test_Block.

         -- Place complex values into data file.

         Load_Data_File(Data_File);
         Text_IO.Close(Data_File);

         if TC_Verbose then
            Report.Comment("Data file loaded with Complex values");
         end if;

         -- Read complex values from data file.

         Text_IO.Open(Data_File, Text_IO.In_File, Data_Filename);
         Process_Data_File(Data_File);

         if TC_Verbose then
            Report.Comment("Complex values extracted from data file");
         end if;



         -- Verify versions of Procedures Put and Get for Strings.

         declare
            TC_String_Array : array (1..Number_Of_Complex_Items) 
                              of String(1..15) := (others =>(others => ' '));
         begin

            -- Place complex values into strings using the Procedure Put.

            for i in 1..Number_Of_Complex_Items loop
               C_IO.Put(To   => TC_String_Array(i),
                        Item => Complex_Array(i),
                        Aft  => 1,
                        Exp  => 0);
            end loop;

            if TC_Verbose then
               Report.Comment("Complex values placed into string array");
            end if;

            -- Check the format of the strings containing a complex number.
            -- The resulting strings are of 15 character length, with the
            -- real component left justified within the string, followed by
            -- a comma, and with the imaginary component and closing 
            -- parenthesis right justified in the string, with blank fill
            -- for the balance of the string.

            if TC_String_Array(1) /= "(3.0,      9.0)" or
               TC_String_Array(2) /= "(4.0,      7.0)" or
               TC_String_Array(3) /= "(5.0,      6.0)" or
               TC_String_Array(4) /= "(6.0,      3.0)" or
               TC_String_Array(5) /= "(2.0,      5.0)" or
               TC_String_Array(6) /= "(3.0,      7.0)" 
            then
               Report.Failed("Incorrect format for complex values that " &
                             "have been placed into string variables "   &
                             "using the Complex_IO.Put procedure for "   &
                             "strings");
            end if;

            if TC_Verbose then
               Report.Comment("String format of Complex values verified");
            end if;

            -- Get complex values from strings using the Procedure Get.
            -- Compare with expected complex values.

            for i in 1..Number_Of_Complex_Items loop

               C_IO.Get(From => TC_String_Array(i),
                        Item => TC_Complex,
                        Last => TC_Last_Character_Read);

               if TC_Complex /= Complex_Array(i) then
                  Report.Failed("Incorrect complex data value obtained "   &
                                "from String following use of Procedures " &
                                "Put and Get from Strings, Complex_Array " &
                                "item #" & Integer'Image(i));
               end if;
            end loop;
         
            if TC_Verbose then
               Report.Comment("Complex values removed from String array");
            end if;

            -- Verify that Layout_Error is raised if the given string is
            -- too short to hold the formatted output.
            Layout_Error_On_Put:
            declare
               Much_Too_Short : String(1..2);
               Complex_Value  : Complex_Pack.Complex := (5.0, 0.0);
            begin
               C_IO.Put(Much_Too_Short, Complex_Value);
               Report.Failed("Layout_Error not raised by Procedure Put " &
                             "when the given string was too short to "   &
                             "hold the formatted output");
            exception
               when Layout_Error => null;  -- OK, expected exception.
               when others =>
                  Report.Failed
                    ("Unexpected exception raised by Procedure Put when " &
                     "the given string was too short to hold the "        &
                     "formatted output");
            end Layout_Error_On_Put;

            if TC_Verbose then
               Report.Comment("Layout Errors verified");
            end if;

         exception
            when others => 
               Report.Failed("Unexpected exception raised during the " &
                             "evaluation of Put and Get for Strings");
         end;


         -- Place complex values into strings using a variety of legal
         -- complex data formats.
         declare

            type String_Ptr is access String;

            TC_Complex_String_Array : 
              array (1..Number_Of_Complex_Items) of String_Ptr := 
              (new String'( "(3.0, 9.0  )"           ), 
               new String'( "+4.0  +7.0"             ),
               new String'( "(5.0 6.0)"              ),
               new String'( "6.0, 3.0"               ),
               new String'( "  (   2.0   , 5.0  )  " ),
               new String'( "(3.0              7.0)" ));

            -- The following array contains Positive values that correspond
            -- to the last character that will be read by Procedure Get when
            -- given each of the above strings as input.

            TC_Last_Char_Array : array (1..Number_Of_Complex_Items) 
               of Positive := (12,10,9,8,20,22);

         begin

            -- Get complex values from strings using the Procedure Get.
            -- Compare with expected complex values.

            for i in 1..Number_Of_Complex_Items loop

               C_IO.Get(TC_Complex_String_Array(i).all, 
                        TC_Complex,
                        TC_Last_Character_Read);

               if TC_Complex /= Complex_Array(i) then
                  Report.Failed
                    ("Incorrect complex data value obtained from " &
                     "Procedure Get with complex data input of: "  & 
                     TC_Complex_String_Array(i).all);
               end if;

               if TC_Last_Character_Read /= TC_Last_Char_Array(i) then
                  Report.Failed
                    ("Incorrect value returned as the last character of " &
                     "the input string processed by Procedure Get, "      &
                     "string value : " & TC_Complex_String_Array(i).all   &
                     "  expected last character value read : "            & 
                     Positive'Image(TC_Last_Char_Array(i))                &
                     "  last character value read : "                     &
                     Positive'Image(TC_Last_Character_Read));
               end if;

            end loop;

            if TC_Verbose then
               Report.Comment("Complex values removed from strings and " &
                              "verified against expected values");
            end if;

         exception
            when others => 
               Report.Failed("Unexpected exception raised during the " &
                             "evaluation of Get for Strings");
         end;

      exception
         when others => Report.Failed ("Exception raised in Test_Block");
      end Test_Block;


      -- Delete the external file.
      if Ada.Text_IO.Is_Open(Data_File) then
         Ada.Text_IO.Delete(Data_File);
      else
         Ada.Text_IO.Open(Data_File, 
                          Ada.Text_IO.In_File,
                          Data_Filename);
         Ada.Text_IO.Delete(Data_File);
      end if;

   exception

      -- Since Use_Error can be raised if, for the specified mode,
      -- the environment does not support Text_IO operations, the 
      -- following handlers are included:

      when Ada.Text_IO.Use_Error  =>
         Report.Not_Applicable ("Use_Error raised on Text_IO Create");

      when Ada.Text_IO.Name_Error  =>
         Report.Not_Applicable ("Name_Error raised on Text_IO Create");

      when others             =>
         Report.Failed ("Unexpected exception raised on text file Create");

   end Test_for_Text_IO_Support;

   Report.Result;

end CXG1003;

Go to most recent revision | Compare with Previous | Blame | View Log

powered by: WebSVN 2.1.0

© copyright 1999-2024 OpenCores.org, equivalent to Oliscience, all rights reserved. OpenCores®, registered trademark.