OpenCores
URL https://opencores.org/ocsvn/openrisc/openrisc/trunk

Subversion Repositories openrisc

[/] [openrisc/] [trunk/] [gnu-stable/] [gcc-4.5.1/] [gcc/] [ada/] [a-textio.adb] - Rev 826

Compare with Previous | Blame | View Log

------------------------------------------------------------------------------
--                                                                          --
--                         GNAT RUN-TIME COMPONENTS                         --
--                                                                          --
--                          A D A . T E X T _ I O                           --
--                                                                          --
--                                 B o d y                                  --
--                                                                          --
--          Copyright (C) 1992-2009, Free Software Foundation, Inc.         --
--                                                                          --
-- GNAT is free software;  you can  redistribute it  and/or modify it under --
-- terms of the  GNU General Public License as published  by the Free Soft- --
-- ware  Foundation;  either version 3,  or (at your option) any later ver- --
-- sion.  GNAT is distributed in the hope that it will be useful, but WITH- --
-- OUT ANY WARRANTY;  without even the  implied warranty of MERCHANTABILITY --
-- or FITNESS FOR A PARTICULAR PURPOSE.                                     --
--                                                                          --
-- As a special exception under Section 7 of GPL version 3, you are granted --
-- additional permissions described in the GCC Runtime Library Exception,   --
-- version 3.1, as published by the Free Software Foundation.               --
--                                                                          --
-- You should have received a copy of the GNU General Public License and    --
-- a copy of the GCC Runtime Library Exception along with this program;     --
-- see the files COPYING3 and COPYING.RUNTIME respectively.  If not, see    --
-- <http://www.gnu.org/licenses/>.                                          --
--                                                                          --
-- GNAT was originally developed  by the GNAT team at  New York University. --
-- Extensive contributions were provided by Ada Core Technologies Inc.      --
--                                                                          --
------------------------------------------------------------------------------
 
with Ada.Streams;          use Ada.Streams;
with Interfaces.C_Streams; use Interfaces.C_Streams;
 
with System.File_IO;
with System.CRTL;
with System.WCh_Cnv;       use System.WCh_Cnv;
with System.WCh_Con;       use System.WCh_Con;
 
with Ada.Unchecked_Conversion;
with Ada.Unchecked_Deallocation;
 
pragma Elaborate_All (System.File_IO);
--  Needed because of calls to Chain_File in package body elaboration
 
package body Ada.Text_IO is
 
   package FIO renames System.File_IO;
 
   subtype AP is FCB.AFCB_Ptr;
 
   function To_FCB is new Ada.Unchecked_Conversion (File_Mode, FCB.File_Mode);
   function To_TIO is new Ada.Unchecked_Conversion (FCB.File_Mode, File_Mode);
   use type FCB.File_Mode;
 
   use type System.CRTL.size_t;
 
   WC_Encoding : Character;
   pragma Import (C, WC_Encoding, "__gl_wc_encoding");
   --  Default wide character encoding
 
   Err_Name : aliased String := "*stderr" & ASCII.NUL;
   In_Name  : aliased String := "*stdin" & ASCII.NUL;
   Out_Name : aliased String := "*stdout" & ASCII.NUL;
   --  Names of standard files
   --
   --  Use "preallocated" strings to avoid calling "new" during the elaboration
   --  of the run time. This is needed in the tasking case to avoid calling
   --  Task_Lock too early. A filename is expected to end with a null character
   --  in the runtime, here the null characters are added just to have a
   --  correct filename length.
   --
   --  Note: the names for these files are bogus, and probably it would be
   --  better for these files to have no names, but the ACVC tests insist!
   --  We use names that are bound to fail in open etc.
 
   Null_Str : aliased constant String := "";
   --  Used as form string for standard files
 
   -----------------------
   -- Local Subprograms --
   -----------------------
 
   function Get_Upper_Half_Char
     (C    : Character;
      File : File_Type) return Character;
   --  This function is shared by Get and Get_Immediate to extract an encoded
   --  upper half character value from the given File. The first byte has
   --  already been read and is passed in C. The character value is returned as
   --  the result, and the file pointer is bumped past the character.
   --  Constraint_Error is raised if the encoded value is outside the bounds of
   --  type Character.
 
   function Get_Upper_Half_Char_Immed
     (C    : Character;
      File : File_Type) return Character;
   --  This routine is identical to Get_Upper_Half_Char, except that the reads
   --  are done in Get_Immediate mode (i.e. without waiting for a line return).
 
   function Getc (File : File_Type) return int;
   --  Gets next character from file, which has already been checked for being
   --  in read status, and returns the character read if no error occurs. The
   --  result is EOF if the end of file was read.
 
   function Getc_Immed (File : File_Type) return int;
   --  This routine is identical to Getc, except that the read is done in
   --  Get_Immediate mode (i.e. without waiting for a line return).
 
   function Has_Upper_Half_Character (Item : String) return Boolean;
   --  Returns True if any of the characters is in the range 16#80#-16#FF#
 
   function Nextc (File : File_Type) return int;
   --  Returns next character from file without skipping past it (i.e. it is a
   --  combination of Getc followed by an Ungetc).
 
   procedure Put_Encoded (File : File_Type; Char : Character);
   --  Called to output a character Char to the given File, when the encoding
   --  method for the file is other than brackets, and Char is upper half.
 
   procedure Putc (ch : int; File : File_Type);
   --  Outputs the given character to the file, which has already been checked
   --  for being in output status. Device_Error is raised if the character
   --  cannot be written.
 
   procedure Set_WCEM (File : in out File_Type);
   --  Called by Open and Create to set the wide character encoding method for
   --  the file, processing a WCEM form parameter if one is present. File is
   --  IN OUT because it may be closed in case of an error.
 
   procedure Terminate_Line (File : File_Type);
   --  If the file is in Write_File or Append_File mode, and the current line
   --  is not terminated, then a line terminator is written using New_Line.
   --  Note that there is no Terminate_Page routine, because the page mark at
   --  the end of the file is implied if necessary.
 
   procedure Ungetc (ch : int; File : File_Type);
   --  Pushes back character into stream, using ungetc. The caller has checked
   --  that the file is in read status. Device_Error is raised if the character
   --  cannot be pushed back. An attempt to push back and end of file character
   --  (EOF) is ignored.
 
   -------------------
   -- AFCB_Allocate --
   -------------------
 
   function AFCB_Allocate (Control_Block : Text_AFCB) return FCB.AFCB_Ptr is
      pragma Unreferenced (Control_Block);
   begin
      return new Text_AFCB;
   end AFCB_Allocate;
 
   ----------------
   -- AFCB_Close --
   ----------------
 
   procedure AFCB_Close (File : not null access Text_AFCB) is
   begin
      --  If the file being closed is one of the current files, then close
      --  the corresponding current file. It is not clear that this action
      --  is required (RM A.10.3(23)) but it seems reasonable, and besides
      --  ACVC test CE3208A expects this behavior.
 
      if File_Type (File) = Current_In then
         Current_In := null;
      elsif File_Type (File) = Current_Out then
         Current_Out := null;
      elsif File_Type (File) = Current_Err then
         Current_Err := null;
      end if;
 
      Terminate_Line (File_Type (File));
   end AFCB_Close;
 
   ---------------
   -- AFCB_Free --
   ---------------
 
   procedure AFCB_Free (File : not null access Text_AFCB) is
      type FCB_Ptr is access all Text_AFCB;
      FT : FCB_Ptr := FCB_Ptr (File);
 
      procedure Free is new Ada.Unchecked_Deallocation (Text_AFCB, FCB_Ptr);
 
   begin
      Free (FT);
   end AFCB_Free;
 
   -----------
   -- Close --
   -----------
 
   procedure Close (File : in out File_Type) is
   begin
      FIO.Close (AP (File)'Unrestricted_Access);
   end Close;
 
   ---------
   -- Col --
   ---------
 
   --  Note: we assume that it is impossible in practice for the column
   --  to exceed the value of Count'Last, i.e. no check is required for
   --  overflow raising layout error.
 
   function Col (File : File_Type) return Positive_Count is
   begin
      FIO.Check_File_Open (AP (File));
      return File.Col;
   end Col;
 
   function Col return Positive_Count is
   begin
      return Col (Current_Out);
   end Col;
 
   ------------
   -- Create --
   ------------
 
   procedure Create
     (File : in out File_Type;
      Mode : File_Mode := Out_File;
      Name : String := "";
      Form : String := "")
   is
      Dummy_File_Control_Block : Text_AFCB;
      pragma Warnings (Off, Dummy_File_Control_Block);
      --  Yes, we know this is never assigned a value, only the tag
      --  is used for dispatching purposes, so that's expected.
 
   begin
      FIO.Open (File_Ptr  => AP (File),
                Dummy_FCB => Dummy_File_Control_Block,
                Mode      => To_FCB (Mode),
                Name      => Name,
                Form      => Form,
                Amethod   => 'T',
                Creat     => True,
                Text      => True);
 
      File.Self := File;
      Set_WCEM (File);
   end Create;
 
   -------------------
   -- Current_Error --
   -------------------
 
   function Current_Error return File_Type is
   begin
      return Current_Err;
   end Current_Error;
 
   function Current_Error return File_Access is
   begin
      return Current_Err.Self'Access;
   end Current_Error;
 
   -------------------
   -- Current_Input --
   -------------------
 
   function Current_Input return File_Type is
   begin
      return Current_In;
   end Current_Input;
 
   function Current_Input return File_Access is
   begin
      return Current_In.Self'Access;
   end Current_Input;
 
   --------------------
   -- Current_Output --
   --------------------
 
   function Current_Output return File_Type is
   begin
      return Current_Out;
   end Current_Output;
 
   function Current_Output return File_Access is
   begin
      return Current_Out.Self'Access;
   end Current_Output;
 
   ------------
   -- Delete --
   ------------
 
   procedure Delete (File : in out File_Type) is
   begin
      FIO.Delete (AP (File)'Unrestricted_Access);
   end Delete;
 
   -----------------
   -- End_Of_File --
   -----------------
 
   function End_Of_File (File : File_Type) return Boolean is
      ch : int;
 
   begin
      FIO.Check_Read_Status (AP (File));
 
      if File.Before_Upper_Half_Character then
         return False;
 
      elsif File.Before_LM then
         if File.Before_LM_PM then
            return Nextc (File) = EOF;
         end if;
 
      else
         ch := Getc (File);
 
         if ch = EOF then
            return True;
 
         elsif ch /= LM then
            Ungetc (ch, File);
            return False;
 
         else -- ch = LM
            File.Before_LM := True;
         end if;
      end if;
 
      --  Here we are just past the line mark with Before_LM set so that we
      --  do not have to try to back up past the LM, thus avoiding the need
      --  to back up more than one character.
 
      ch := Getc (File);
 
      if ch = EOF then
         return True;
 
      elsif ch = PM and then File.Is_Regular_File then
         File.Before_LM_PM := True;
         return Nextc (File) = EOF;
 
      --  Here if neither EOF nor PM followed end of line
 
      else
         Ungetc (ch, File);
         return False;
      end if;
 
   end End_Of_File;
 
   function End_Of_File return Boolean is
   begin
      return End_Of_File (Current_In);
   end End_Of_File;
 
   -----------------
   -- End_Of_Line --
   -----------------
 
   function End_Of_Line (File : File_Type) return Boolean is
      ch : int;
 
   begin
      FIO.Check_Read_Status (AP (File));
 
      if File.Before_Upper_Half_Character then
         return False;
 
      elsif File.Before_LM then
         return True;
 
      else
         ch := Getc (File);
 
         if ch = EOF then
            return True;
 
         else
            Ungetc (ch, File);
            return (ch = LM);
         end if;
      end if;
   end End_Of_Line;
 
   function End_Of_Line return Boolean is
   begin
      return End_Of_Line (Current_In);
   end End_Of_Line;
 
   -----------------
   -- End_Of_Page --
   -----------------
 
   function End_Of_Page (File : File_Type) return Boolean is
      ch  : int;
 
   begin
      FIO.Check_Read_Status (AP (File));
 
      if not File.Is_Regular_File then
         return False;
 
      elsif File.Before_Upper_Half_Character then
         return False;
 
      elsif File.Before_LM then
         if File.Before_LM_PM then
            return True;
         end if;
 
      else
         ch := Getc (File);
 
         if ch = EOF then
            return True;
 
         elsif ch /= LM then
            Ungetc (ch, File);
            return False;
 
         else -- ch = LM
            File.Before_LM := True;
         end if;
      end if;
 
      --  Here we are just past the line mark with Before_LM set so that we
      --  do not have to try to back up past the LM, thus avoiding the need
      --  to back up more than one character.
 
      ch := Nextc (File);
 
      return ch = PM or else ch = EOF;
   end End_Of_Page;
 
   function End_Of_Page return Boolean is
   begin
      return End_Of_Page (Current_In);
   end End_Of_Page;
 
   --------------
   -- EOF_Char --
   --------------
 
   function EOF_Char return Integer is
   begin
      return EOF;
   end EOF_Char;
 
   -----------
   -- Flush --
   -----------
 
   procedure Flush (File : File_Type) is
   begin
      FIO.Flush (AP (File));
   end Flush;
 
   procedure Flush is
   begin
      Flush (Current_Out);
   end Flush;
 
   ----------
   -- Form --
   ----------
 
   function Form (File : File_Type) return String is
   begin
      return FIO.Form (AP (File));
   end Form;
 
   ---------
   -- Get --
   ---------
 
   procedure Get
     (File : File_Type;
      Item : out Character)
   is
      ch : int;
 
   begin
      FIO.Check_Read_Status (AP (File));
 
      if File.Before_Upper_Half_Character then
         File.Before_Upper_Half_Character := False;
         Item := File.Saved_Upper_Half_Character;
 
      elsif File.Before_LM then
         File.Before_LM := False;
         File.Col := 1;
 
         if File.Before_LM_PM then
            File.Line := 1;
            File.Page := File.Page + 1;
            File.Before_LM_PM := False;
         else
            File.Line := File.Line + 1;
         end if;
      end if;
 
      loop
         ch := Getc (File);
 
         if ch = EOF then
            raise End_Error;
 
         elsif ch = LM then
            File.Line := File.Line + 1;
            File.Col := 1;
 
         elsif ch = PM and then File.Is_Regular_File then
            File.Page := File.Page + 1;
            File.Line := 1;
 
         else
            Item := Character'Val (ch);
            File.Col := File.Col + 1;
            return;
         end if;
      end loop;
   end Get;
 
   procedure Get (Item : out Character) is
   begin
      Get (Current_In, Item);
   end Get;
 
   procedure Get
     (File : File_Type;
      Item : out String)
   is
      ch : int;
      J  : Natural;
 
   begin
      FIO.Check_Read_Status (AP (File));
 
      if File.Before_LM then
         File.Before_LM := False;
         File.Before_LM_PM := False;
         File.Col := 1;
 
         if File.Before_LM_PM then
            File.Line := 1;
            File.Page := File.Page + 1;
            File.Before_LM_PM := False;
 
         else
            File.Line := File.Line + 1;
         end if;
      end if;
 
      J := Item'First;
      while J <= Item'Last loop
         ch := Getc (File);
 
         if ch = EOF then
            raise End_Error;
 
         elsif ch = LM then
            File.Line := File.Line + 1;
            File.Col := 1;
 
         elsif ch = PM and then File.Is_Regular_File then
            File.Page := File.Page + 1;
            File.Line := 1;
 
         else
            Item (J) := Character'Val (ch);
            J := J + 1;
            File.Col := File.Col + 1;
         end if;
      end loop;
   end Get;
 
   procedure Get (Item : out String) is
   begin
      Get (Current_In, Item);
   end Get;
 
   -------------------
   -- Get_Immediate --
   -------------------
 
   procedure Get_Immediate
     (File : File_Type;
      Item : out Character)
   is
      ch          : int;
 
   begin
      FIO.Check_Read_Status (AP (File));
 
      if File.Before_Upper_Half_Character then
         File.Before_Upper_Half_Character := False;
         Item := File.Saved_Upper_Half_Character;
 
      elsif File.Before_LM then
         File.Before_LM := False;
         File.Before_LM_PM := False;
         Item := Character'Val (LM);
 
      else
         ch := Getc_Immed (File);
 
         if ch = EOF then
            raise End_Error;
         else
            Item :=
              (if not Is_Start_Of_Encoding (Character'Val (ch), File.WC_Method)
               then Character'Val (ch)
               else Get_Upper_Half_Char_Immed (Character'Val (ch), File));
         end if;
      end if;
   end Get_Immediate;
 
   procedure Get_Immediate
     (Item : out Character)
   is
   begin
      Get_Immediate (Current_In, Item);
   end Get_Immediate;
 
   procedure Get_Immediate
     (File      : File_Type;
      Item      : out Character;
      Available : out Boolean)
   is
      ch          : int;
      end_of_file : int;
      avail       : int;
 
      procedure getc_immediate_nowait
        (stream      : FILEs;
         ch          : out int;
         end_of_file : out int;
         avail       : out int);
      pragma Import (C, getc_immediate_nowait, "getc_immediate_nowait");
 
   begin
      FIO.Check_Read_Status (AP (File));
      Available := True;
 
      if File.Before_Upper_Half_Character then
         File.Before_Upper_Half_Character := False;
         Item := File.Saved_Upper_Half_Character;
 
      elsif File.Before_LM then
         File.Before_LM := False;
         File.Before_LM_PM := False;
         Item := Character'Val (LM);
 
      else
         getc_immediate_nowait (File.Stream, ch, end_of_file, avail);
 
         if ferror (File.Stream) /= 0 then
            raise Device_Error;
 
         elsif end_of_file /= 0 then
            raise End_Error;
 
         elsif avail = 0 then
            Available := False;
            Item := ASCII.NUL;
 
         else
            Available := True;
 
            Item :=
              (if Is_Start_Of_Encoding (Character'Val (ch), File.WC_Method)
               then Character'Val (ch)
               else Get_Upper_Half_Char_Immed (Character'Val (ch), File));
         end if;
      end if;
 
   end Get_Immediate;
 
   procedure Get_Immediate
     (Item      : out Character;
      Available : out Boolean)
   is
   begin
      Get_Immediate (Current_In, Item, Available);
   end Get_Immediate;
 
   --------------
   -- Get_Line --
   --------------
 
   procedure Get_Line
     (File : File_Type;
      Item : out String;
      Last : out Natural)
   is
      ch : int;
 
   begin
      FIO.Check_Read_Status (AP (File));
      Last := Item'First - 1;
 
      --  Immediate exit for null string, this is a case in which we do not
      --  need to test for end of file and we do not skip a line mark under
      --  any circumstances.
 
      if Last >= Item'Last then
         return;
      end if;
 
      --  Here we have at least one character, if we are immediately before
      --  a line mark, then we will just skip past it storing no characters.
 
      if File.Before_LM then
         File.Before_LM := False;
         File.Before_LM_PM := False;
 
      --  Otherwise we need to read some characters
 
      else
         ch := Getc (File);
 
         --  If we are at the end of file now, it means we are trying to
         --  skip a file terminator and we raise End_Error (RM A.10.7(20))
 
         if ch = EOF then
            raise End_Error;
         end if;
 
         --  Loop through characters. Don't bother if we hit a page mark,
         --  since in normal files, page marks can only follow line marks
         --  in any case and we only promise to treat the page nonsense
         --  correctly in the absense of such rogue page marks.
 
         loop
            --  Exit the loop if read is terminated by encountering line mark
 
            exit when ch = LM;
 
            --  Otherwise store the character, note that we know that ch is
            --  something other than LM or EOF. It could possibly be a page
            --  mark if there is a stray page mark in the middle of a line,
            --  but this is not an official page mark in any case, since
            --  official page marks can only follow a line mark. The whole
            --  page business is pretty much nonsense anyway, so we do not
            --  want to waste time trying to make sense out of non-standard
            --  page marks in the file! This means that the behavior of
            --  Get_Line is different from repeated Get of a character, but
            --  that's too bad. We only promise that page numbers etc make
            --  sense if the file is formatted in a standard manner.
 
            --  Note: we do not adjust the column number because it is quicker
            --  to adjust it once at the end of the operation than incrementing
            --  it each time around the loop.
 
            Last := Last + 1;
            Item (Last) := Character'Val (ch);
 
            --  All done if the string is full, this is the case in which
            --  we do not skip the following line mark. We need to adjust
            --  the column number in this case.
 
            if Last = Item'Last then
               File.Col := File.Col + Count (Item'Length);
               return;
            end if;
 
            --  Otherwise read next character. We also exit from the loop if
            --  we read an end of file. This is the case where the last line
            --  is not terminated with a line mark, and we consider that there
            --  is an implied line mark in this case (this is a non-standard
            --  file, but it is nice to treat it reasonably).
 
            ch := Getc (File);
            exit when ch = EOF;
         end loop;
      end if;
 
      --  We have skipped past, but not stored, a line mark. Skip following
      --  page mark if one follows, but do not do this for a non-regular
      --  file (since otherwise we get annoying wait for an extra character)
 
      File.Line := File.Line + 1;
      File.Col := 1;
 
      if File.Before_LM_PM then
         File.Line := 1;
         File.Before_LM_PM := False;
         File.Page := File.Page + 1;
 
      elsif File.Is_Regular_File then
         ch := Getc (File);
 
         if ch = PM and then File.Is_Regular_File then
            File.Line := 1;
            File.Page := File.Page + 1;
         else
            Ungetc (ch, File);
         end if;
      end if;
   end Get_Line;
 
   procedure Get_Line
     (Item : out String;
      Last : out Natural)
   is
   begin
      Get_Line (Current_In, Item, Last);
   end Get_Line;
 
   function Get_Line (File : File_Type) return String is
      Buffer : String (1 .. 500);
      Last   : Natural;
 
      function Get_Rest (S : String) return String;
      --  This is a recursive function that reads the rest of the line and
      --  returns it. S is the part read so far.
 
      --------------
      -- Get_Rest --
      --------------
 
      function Get_Rest (S : String) return String is
 
         --  Each time we allocate a buffer the same size as what we have
         --  read so far. This limits us to a logarithmic number of calls
         --  to Get_Rest and also ensures only a linear use of stack space.
 
         Buffer : String (1 .. S'Length);
         Last   : Natural;
 
      begin
         Get_Line (File, Buffer, Last);
 
         declare
            R : constant String := S & Buffer (1 .. Last);
         begin
            if Last < Buffer'Last then
               return R;
            else
               return Get_Rest (R);
            end if;
         end;
      end Get_Rest;
 
   --  Start of processing for Get_Line
 
   begin
      Get_Line (File, Buffer, Last);
 
      if Last < Buffer'Last then
         return Buffer (1 .. Last);
      else
         return Get_Rest (Buffer (1 .. Last));
      end if;
   end Get_Line;
 
   function Get_Line return String is
   begin
      return Get_Line (Current_In);
   end Get_Line;
 
   -------------------------
   -- Get_Upper_Half_Char --
   -------------------------
 
   function Get_Upper_Half_Char
     (C    : Character;
      File : File_Type) return Character
   is
      Result : Wide_Character;
 
      function In_Char return Character;
      --  Function used to obtain additional characters it the wide character
      --  sequence is more than one character long.
 
      function WC_In is new Char_Sequence_To_Wide_Char (In_Char);
 
      -------------
      -- In_Char --
      -------------
 
      function In_Char return Character is
         ch : constant Integer := Getc (File);
      begin
         if ch = EOF then
            raise End_Error;
         else
            return Character'Val (ch);
         end if;
      end In_Char;
 
   --  Start of processing for Get_Upper_Half_Char
 
   begin
      Result := WC_In (C, File.WC_Method);
 
      if Wide_Character'Pos (Result) > 16#FF# then
         raise Constraint_Error with
           "invalid wide character in Text_'I'O input";
      else
         return Character'Val (Wide_Character'Pos (Result));
      end if;
   end Get_Upper_Half_Char;
 
   -------------------------------
   -- Get_Upper_Half_Char_Immed --
   -------------------------------
 
   function Get_Upper_Half_Char_Immed
     (C    : Character;
      File : File_Type) return Character
   is
      Result : Wide_Character;
 
      function In_Char return Character;
      --  Function used to obtain additional characters it the wide character
      --  sequence is more than one character long.
 
      function WC_In is new Char_Sequence_To_Wide_Char (In_Char);
 
      -------------
      -- In_Char --
      -------------
 
      function In_Char return Character is
         ch : constant Integer := Getc_Immed (File);
      begin
         if ch = EOF then
            raise End_Error;
         else
            return Character'Val (ch);
         end if;
      end In_Char;
 
   --  Start of processing for Get_Upper_Half_Char_Immed
 
   begin
      Result := WC_In (C, File.WC_Method);
 
      if Wide_Character'Pos (Result) > 16#FF# then
         raise Constraint_Error with
           "invalid wide character in Text_'I'O input";
      else
         return Character'Val (Wide_Character'Pos (Result));
      end if;
   end Get_Upper_Half_Char_Immed;
 
   ----------
   -- Getc --
   ----------
 
   function Getc (File : File_Type) return int is
      ch : int;
 
   begin
      ch := fgetc (File.Stream);
 
      if ch = EOF and then ferror (File.Stream) /= 0 then
         raise Device_Error;
      else
         return ch;
      end if;
   end Getc;
 
   ----------------
   -- Getc_Immed --
   ----------------
 
   function Getc_Immed (File : File_Type) return int is
      ch          : int;
      end_of_file : int;
 
      procedure getc_immediate
        (stream : FILEs; ch : out int; end_of_file : out int);
      pragma Import (C, getc_immediate, "getc_immediate");
 
   begin
      FIO.Check_Read_Status (AP (File));
 
      if File.Before_LM then
         File.Before_LM := False;
         File.Before_LM_PM := False;
         ch := LM;
 
      else
         getc_immediate (File.Stream, ch, end_of_file);
 
         if ferror (File.Stream) /= 0 then
            raise Device_Error;
         elsif end_of_file /= 0 then
            return EOF;
         end if;
      end if;
 
      return ch;
   end Getc_Immed;
 
   ------------------------------
   -- Has_Upper_Half_Character --
   ------------------------------
 
   function Has_Upper_Half_Character (Item : String) return Boolean is
   begin
      for J in Item'Range loop
         if Character'Pos (Item (J)) >= 16#80# then
            return True;
         end if;
      end loop;
 
      return False;
   end Has_Upper_Half_Character;
 
   -------------------------------
   -- Initialize_Standard_Files --
   -------------------------------
 
   procedure Initialize_Standard_Files is
   begin
      Standard_Err.Stream            := stderr;
      Standard_Err.Name              := Err_Name'Access;
      Standard_Err.Form              := Null_Str'Unrestricted_Access;
      Standard_Err.Mode              := FCB.Out_File;
      Standard_Err.Is_Regular_File   := is_regular_file (fileno (stderr)) /= 0;
      Standard_Err.Is_Temporary_File := False;
      Standard_Err.Is_System_File    := True;
      Standard_Err.Is_Text_File      := True;
      Standard_Err.Access_Method     := 'T';
      Standard_Err.Self              := Standard_Err;
      Standard_Err.WC_Method         := Default_WCEM;
 
      Standard_In.Stream             := stdin;
      Standard_In.Name               := In_Name'Access;
      Standard_In.Form               := Null_Str'Unrestricted_Access;
      Standard_In.Mode               := FCB.In_File;
      Standard_In.Is_Regular_File    := is_regular_file (fileno (stdin)) /= 0;
      Standard_In.Is_Temporary_File  := False;
      Standard_In.Is_System_File     := True;
      Standard_In.Is_Text_File       := True;
      Standard_In.Access_Method      := 'T';
      Standard_In.Self               := Standard_In;
      Standard_In.WC_Method          := Default_WCEM;
 
      Standard_Out.Stream            := stdout;
      Standard_Out.Name              := Out_Name'Access;
      Standard_Out.Form              := Null_Str'Unrestricted_Access;
      Standard_Out.Mode              := FCB.Out_File;
      Standard_Out.Is_Regular_File   := is_regular_file (fileno (stdout)) /= 0;
      Standard_Out.Is_Temporary_File := False;
      Standard_Out.Is_System_File    := True;
      Standard_Out.Is_Text_File      := True;
      Standard_Out.Access_Method     := 'T';
      Standard_Out.Self              := Standard_Out;
      Standard_Out.WC_Method         := Default_WCEM;
 
      FIO.Make_Unbuffered (AP (Standard_Out));
      FIO.Make_Unbuffered (AP (Standard_Err));
   end Initialize_Standard_Files;
 
   -------------
   -- Is_Open --
   -------------
 
   function Is_Open (File : File_Type) return Boolean is
   begin
      return FIO.Is_Open (AP (File));
   end Is_Open;
 
   ----------
   -- Line --
   ----------
 
   --  Note: we assume that it is impossible in practice for the line
   --  to exceed the value of Count'Last, i.e. no check is required for
   --  overflow raising layout error.
 
   function Line (File : File_Type) return Positive_Count is
   begin
      FIO.Check_File_Open (AP (File));
      return File.Line;
   end Line;
 
   function Line return Positive_Count is
   begin
      return Line (Current_Out);
   end Line;
 
   -----------------
   -- Line_Length --
   -----------------
 
   function Line_Length (File : File_Type) return Count is
   begin
      FIO.Check_Write_Status (AP (File));
      return File.Line_Length;
   end Line_Length;
 
   function Line_Length return Count is
   begin
      return Line_Length (Current_Out);
   end Line_Length;
 
   ----------------
   -- Look_Ahead --
   ----------------
 
   procedure Look_Ahead
     (File        : File_Type;
      Item        : out Character;
      End_Of_Line : out Boolean)
   is
      ch : int;
 
   begin
      FIO.Check_Read_Status (AP (File));
 
      --  If we are logically before a line mark, we can return immediately
 
      if File.Before_LM then
         End_Of_Line := True;
         Item := ASCII.NUL;
 
      --  If we are before an upper half character just return it (this can
      --  happen if there are two calls to Look_Ahead in a row).
 
      elsif File.Before_Upper_Half_Character then
         End_Of_Line := False;
         Item := File.Saved_Upper_Half_Character;
 
      --  Otherwise we must read a character from the input stream
 
      else
         ch := Getc (File);
 
         if ch = LM
           or else ch = EOF
           or else (ch = PM and then File.Is_Regular_File)
         then
            End_Of_Line := True;
            Ungetc (ch, File);
            Item := ASCII.NUL;
 
         --  Case where character obtained does not represent the start of an
         --  encoded sequence so it stands for itself and we can unget it with
         --  no difficulty.
 
         elsif not Is_Start_Of_Encoding
                     (Character'Val (ch), File.WC_Method)
         then
            End_Of_Line := False;
            Ungetc (ch, File);
            Item := Character'Val (ch);
 
         --  For the start of an encoding, we read the character using the
         --  Get_Upper_Half_Char routine. It will occupy more than one byte
         --  so we can't put it back with ungetc. Instead we save it in the
         --  control block, setting a flag that everyone interested in reading
         --  characters must test before reading the stream.
 
         else
            Item := Get_Upper_Half_Char (Character'Val (ch), File);
            End_Of_Line := False;
            File.Saved_Upper_Half_Character := Item;
            File.Before_Upper_Half_Character := True;
         end if;
      end if;
   end Look_Ahead;
 
   procedure Look_Ahead
     (Item        : out Character;
      End_Of_Line : out Boolean)
   is
   begin
      Look_Ahead (Current_In, Item, End_Of_Line);
   end Look_Ahead;
 
   ----------
   -- Mode --
   ----------
 
   function Mode (File : File_Type) return File_Mode is
   begin
      return To_TIO (FIO.Mode (AP (File)));
   end Mode;
 
   ----------
   -- Name --
   ----------
 
   function Name (File : File_Type) return String is
   begin
      return FIO.Name (AP (File));
   end Name;
 
   --------------
   -- New_Line --
   --------------
 
   procedure New_Line
     (File    : File_Type;
      Spacing : Positive_Count := 1)
   is
   begin
      --  Raise Constraint_Error if out of range value. The reason for this
      --  explicit test is that we don't want junk values around, even if
      --  checks are off in the caller.
 
      if not Spacing'Valid then
         raise Constraint_Error;
      end if;
 
      FIO.Check_Write_Status (AP (File));
 
      for K in 1 .. Spacing loop
         Putc (LM, File);
         File.Line := File.Line + 1;
 
         if File.Page_Length /= 0
           and then File.Line > File.Page_Length
         then
            Putc (PM, File);
            File.Line := 1;
            File.Page := File.Page + 1;
         end if;
      end loop;
 
      File.Col := 1;
   end New_Line;
 
   procedure New_Line (Spacing : Positive_Count := 1) is
   begin
      New_Line (Current_Out, Spacing);
   end New_Line;
 
   --------------
   -- New_Page --
   --------------
 
   procedure New_Page (File : File_Type) is
   begin
      FIO.Check_Write_Status (AP (File));
 
      if File.Col /= 1 or else File.Line = 1 then
         Putc (LM, File);
      end if;
 
      Putc (PM, File);
      File.Page := File.Page + 1;
      File.Line := 1;
      File.Col := 1;
   end New_Page;
 
   procedure New_Page is
   begin
      New_Page (Current_Out);
   end New_Page;
 
   -----------
   -- Nextc --
   -----------
 
   function Nextc (File : File_Type) return int is
      ch : int;
 
   begin
      ch := fgetc (File.Stream);
 
      if ch = EOF then
         if ferror (File.Stream) /= 0 then
            raise Device_Error;
         end if;
 
      else
         if ungetc (ch, File.Stream) = EOF then
            raise Device_Error;
         end if;
      end if;
 
      return ch;
   end Nextc;
 
   ----------
   -- Open --
   ----------
 
   procedure Open
     (File : in out File_Type;
      Mode : File_Mode;
      Name : String;
      Form : String := "")
   is
      Dummy_File_Control_Block : Text_AFCB;
      pragma Warnings (Off, Dummy_File_Control_Block);
      --  Yes, we know this is never assigned a value, only the tag
      --  is used for dispatching purposes, so that's expected.
 
   begin
      FIO.Open (File_Ptr  => AP (File),
                Dummy_FCB => Dummy_File_Control_Block,
                Mode      => To_FCB (Mode),
                Name      => Name,
                Form      => Form,
                Amethod   => 'T',
                Creat     => False,
                Text      => True);
 
      File.Self := File;
      Set_WCEM (File);
   end Open;
 
   ----------
   -- Page --
   ----------
 
   --  Note: we assume that it is impossible in practice for the page
   --  to exceed the value of Count'Last, i.e. no check is required for
   --  overflow raising layout error.
 
   function Page (File : File_Type) return Positive_Count is
   begin
      FIO.Check_File_Open (AP (File));
      return File.Page;
   end Page;
 
   function Page return Positive_Count is
   begin
      return Page (Current_Out);
   end Page;
 
   -----------------
   -- Page_Length --
   -----------------
 
   function Page_Length (File : File_Type) return Count is
   begin
      FIO.Check_Write_Status (AP (File));
      return File.Page_Length;
   end Page_Length;
 
   function Page_Length return Count is
   begin
      return Page_Length (Current_Out);
   end Page_Length;
 
   ---------
   -- Put --
   ---------
 
   procedure Put
     (File : File_Type;
      Item : Character)
   is
   begin
      FIO.Check_Write_Status (AP (File));
 
      if File.Line_Length /= 0 and then File.Col > File.Line_Length then
         New_Line (File);
      end if;
 
      --  If lower half character, or brackets encoding, output directly
 
      if Character'Pos (Item) < 16#80#
        or else File.WC_Method = WCEM_Brackets
      then
         if fputc (Character'Pos (Item), File.Stream) = EOF then
            raise Device_Error;
         end if;
 
      --  Case of upper half character with non-brackets encoding
 
      else
         Put_Encoded (File, Item);
      end if;
 
      File.Col := File.Col + 1;
   end Put;
 
   procedure Put (Item : Character) is
   begin
      FIO.Check_Write_Status (AP (Current_Out));
 
      if Current_Out.Line_Length /= 0
        and then Current_Out.Col > Current_Out.Line_Length
      then
         New_Line (Current_Out);
      end if;
 
      --  If lower half character, or brackets encoding, output directly
 
      if Character'Pos (Item) < 16#80#
        or else Default_WCEM = WCEM_Brackets
      then
         if fputc (Character'Pos (Item), Current_Out.Stream) = EOF then
            raise Device_Error;
         end if;
 
      --  Case of upper half character with non-brackets encoding
 
      else
         Put_Encoded (Current_Out, Item);
      end if;
 
      Current_Out.Col := Current_Out.Col + 1;
   end Put;
 
   ---------
   -- Put --
   ---------
 
   procedure Put
     (File : File_Type;
      Item : String)
   is
   begin
      FIO.Check_Write_Status (AP (File));
 
      --  Only have something to do if string is non-null
 
      if Item'Length > 0 then
 
         --  If we have bounded lines, or if the file encoding is other than
         --  Brackets and the string has at least one upper half character,
         --  then output the string character by character.
 
         if File.Line_Length /= 0
           or else (File.WC_Method /= WCEM_Brackets
                      and then Has_Upper_Half_Character (Item))
         then
            for J in Item'Range loop
               Put (File, Item (J));
            end loop;
 
         --  Otherwise we can output the entire string at once. Note that if
         --  there are LF or FF characters in the string, we do not bother to
         --  count them as line or page terminators.
 
         else
            FIO.Write_Buf (AP (File), Item'Address, Item'Length);
            File.Col := File.Col + Item'Length;
         end if;
      end if;
   end Put;
 
   procedure Put (Item : String) is
   begin
      Put (Current_Out, Item);
   end Put;
 
   -----------------
   -- Put_Encoded --
   -----------------
 
   procedure Put_Encoded (File : File_Type; Char : Character) is
      procedure Out_Char (C : Character);
      --  Procedure to output one character of an upper half encoded sequence
 
      procedure WC_Out is new Wide_Char_To_Char_Sequence (Out_Char);
 
      --------------
      -- Out_Char --
      --------------
 
      procedure Out_Char (C : Character) is
      begin
         Putc (Character'Pos (C), File);
      end Out_Char;
 
   --  Start of processing for Put_Encoded
 
   begin
      WC_Out (Wide_Character'Val (Character'Pos (Char)), File.WC_Method);
   end Put_Encoded;
 
   --------------
   -- Put_Line --
   --------------
 
   procedure Put_Line
     (File : File_Type;
      Item : String)
   is
      Ilen   : Natural := Item'Length;
      Istart : Natural := Item'First;
 
   begin
      FIO.Check_Write_Status (AP (File));
 
      --  If we have bounded lines, or if the file encoding is other than
      --  Brackets and the string has at least one upper half character, then
      --  output the string character by character.
 
      if File.Line_Length /= 0
        or else (File.WC_Method /= WCEM_Brackets
                   and then Has_Upper_Half_Character (Item))
      then
         for J in Item'Range loop
            Put (File, Item (J));
         end loop;
 
         New_Line (File);
         return;
      end if;
 
      --  Normal case where we do not need to output character by character
 
      --  We setup a single string that has the necessary terminators and
      --  then write it with a single call. The reason for doing this is
      --  that it gives better behavior for the use of Put_Line in multi-
      --  tasking programs, since often the OS will treat the entire put
      --  operation as an atomic operation.
 
      --  We only do this if the message is 512 characters or less in length,
      --  since otherwise Put_Line would use an unbounded amount of stack
      --  space and could cause undetected stack overflow. If we have a
      --  longer string, then output the first part separately to avoid this.
 
      if Ilen > 512 then
         FIO.Write_Buf (AP (File), Item'Address, size_t (Ilen - 512));
         Istart := Istart + Ilen - 512;
         Ilen   := 512;
      end if;
 
      --  Now prepare the string with its terminator
 
      declare
         Buffer : String (1 .. Ilen + 2);
         Plen   : size_t;
 
      begin
         Buffer (1 .. Ilen) := Item (Istart .. Item'Last);
         Buffer (Ilen + 1) := Character'Val (LM);
 
         if File.Page_Length /= 0
           and then File.Line > File.Page_Length
         then
            Buffer (Ilen + 2) := Character'Val (PM);
            Plen := size_t (Ilen) + 2;
            File.Line := 1;
            File.Page := File.Page + 1;
 
         else
            Plen := size_t (Ilen) + 1;
            File.Line := File.Line + 1;
         end if;
 
         FIO.Write_Buf (AP (File), Buffer'Address, Plen);
 
         File.Col := 1;
      end;
   end Put_Line;
 
   procedure Put_Line (Item : String) is
   begin
      Put_Line (Current_Out, Item);
   end Put_Line;
 
   ----------
   -- Putc --
   ----------
 
   procedure Putc (ch : int; File : File_Type) is
   begin
      if fputc (ch, File.Stream) = EOF then
         raise Device_Error;
      end if;
   end Putc;
 
   ----------
   -- Read --
   ----------
 
   --  This is the primitive Stream Read routine, used when a Text_IO file
   --  is treated directly as a stream using Text_IO.Streams.Stream.
 
   procedure Read
     (File : in out Text_AFCB;
      Item : out Stream_Element_Array;
      Last : out Stream_Element_Offset)
   is
      Discard_ch : int;
      pragma Warnings (Off, Discard_ch);
 
   begin
      --  Need to deal with Before_Upper_Half_Character ???
 
      if File.Mode /= FCB.In_File then
         raise Mode_Error;
      end if;
 
      --  Deal with case where our logical and physical position do not match
      --  because of being after an LM or LM-PM sequence when in fact we are
      --  logically positioned before it.
 
      if File.Before_LM then
 
         --  If we are before a PM, then it is possible for a stream read
         --  to leave us after the LM and before the PM, which is a bit
         --  odd. The easiest way to deal with this is to unget the PM,
         --  so we are indeed positioned between the characters. This way
         --  further stream read operations will work correctly, and the
         --  effect on text processing is a little weird, but what can
         --  be expected if stream and text input are mixed this way?
 
         if File.Before_LM_PM then
            Discard_ch := ungetc (PM, File.Stream);
            File.Before_LM_PM := False;
         end if;
 
         File.Before_LM := False;
 
         Item (Item'First) := Stream_Element (Character'Pos (ASCII.LF));
 
         if Item'Length = 1 then
            Last := Item'Last;
 
         else
            Last :=
              Item'First +
                Stream_Element_Offset
                  (fread (buffer => Item'Address,
                          index  => size_t (Item'First + 1),
                          size   => 1,
                          count  => Item'Length - 1,
                          stream => File.Stream));
         end if;
 
         return;
      end if;
 
      --  Now we do the read. Since this is a text file, it is normally in
      --  text mode, but stream data must be read in binary mode, so we
      --  temporarily set binary mode for the read, resetting it after.
      --  These calls have no effect in a system (like Unix) where there is
      --  no distinction between text and binary files.
 
      set_binary_mode (fileno (File.Stream));
 
      Last :=
        Item'First +
          Stream_Element_Offset
            (fread (Item'Address, 1, Item'Length, File.Stream)) - 1;
 
      if Last < Item'Last then
         if ferror (File.Stream) /= 0 then
            raise Device_Error;
         end if;
      end if;
 
      set_text_mode (fileno (File.Stream));
   end Read;
 
   -----------
   -- Reset --
   -----------
 
   procedure Reset
     (File : in out File_Type;
      Mode : File_Mode)
   is
   begin
      --  Don't allow change of mode for current file (RM A.10.2(5))
 
      if (File = Current_In  or else
          File = Current_Out or else
          File = Current_Error)
        and then To_FCB (Mode) /= File.Mode
      then
         raise Mode_Error;
      end if;
 
      Terminate_Line (File);
      FIO.Reset (AP (File)'Unrestricted_Access, To_FCB (Mode));
      File.Page := 1;
      File.Line := 1;
      File.Col  := 1;
      File.Line_Length := 0;
      File.Page_Length := 0;
      File.Before_LM := False;
      File.Before_LM_PM := False;
   end Reset;
 
   procedure Reset (File : in out File_Type) is
   begin
      Terminate_Line (File);
      FIO.Reset (AP (File)'Unrestricted_Access);
      File.Page := 1;
      File.Line := 1;
      File.Col  := 1;
      File.Line_Length := 0;
      File.Page_Length := 0;
      File.Before_LM := False;
      File.Before_LM_PM := False;
   end Reset;
 
   -------------
   -- Set_Col --
   -------------
 
   procedure Set_Col
     (File : File_Type;
      To   : Positive_Count)
   is
      ch : int;
 
   begin
      --  Raise Constraint_Error if out of range value. The reason for this
      --  explicit test is that we don't want junk values around, even if
      --  checks are off in the caller.
 
      if not To'Valid then
         raise Constraint_Error;
      end if;
 
      FIO.Check_File_Open (AP (File));
 
      --  Output case
 
      if Mode (File) >= Out_File then
 
         --  Error if we attempt to set Col to a value greater than the
         --  maximum permissible line length.
 
         if File.Line_Length /= 0 and then To > File.Line_Length then
            raise Layout_Error;
         end if;
 
         --  If we are behind current position, then go to start of new line
 
         if To < File.Col then
            New_Line (File);
         end if;
 
         --  Loop to output blanks till we are at the required column
 
         while File.Col < To loop
            Put (File, ' ');
         end loop;
 
      --  Input case
 
      else
         --  If we are logically before a LM, but physically after it, the
         --  file position still reflects the position before the LM, so eat
         --  it now and adjust the file position appropriately.
 
         if File.Before_LM then
            File.Before_LM := False;
            File.Before_LM_PM := False;
            File.Line := File.Line + 1;
            File.Col := 1;
         end if;
 
         --  Loop reading characters till we get one at the required Col value
 
         loop
            --  Read next character. The reason we have to read ahead is to
            --  skip formatting characters, the effect of Set_Col is to set
            --  us to a real character with the right Col value, and format
            --  characters don't count.
 
            ch := Getc (File);
 
            --  Error if we hit an end of file
 
            if ch = EOF then
               raise End_Error;
 
            --  If line mark, eat it and adjust file position
 
            elsif ch = LM then
               File.Line := File.Line + 1;
               File.Col := 1;
 
            --  If recognized page mark, eat it, and adjust file position
 
            elsif ch = PM and then File.Is_Regular_File then
               File.Page := File.Page + 1;
               File.Line := 1;
               File.Col := 1;
 
            --  Otherwise this is the character we are looking for, so put it
            --  back in the input stream (we have not adjusted the file
            --  position yet, so everything is set right after this ungetc).
 
            elsif To = File.Col then
               Ungetc (ch, File);
               return;
 
            --  Keep skipping characters if we are not there yet, updating the
            --  file position past the skipped character.
 
            else
               File.Col := File.Col + 1;
            end if;
         end loop;
      end if;
   end Set_Col;
 
   procedure Set_Col (To : Positive_Count) is
   begin
      Set_Col (Current_Out, To);
   end Set_Col;
 
   ---------------
   -- Set_Error --
   ---------------
 
   procedure Set_Error (File : File_Type) is
   begin
      FIO.Check_Write_Status (AP (File));
      Current_Err := File;
   end Set_Error;
 
   ---------------
   -- Set_Input --
   ---------------
 
   procedure Set_Input (File : File_Type) is
   begin
      FIO.Check_Read_Status (AP (File));
      Current_In := File;
   end Set_Input;
 
   --------------
   -- Set_Line --
   --------------
 
   procedure Set_Line
     (File : File_Type;
      To   : Positive_Count)
   is
   begin
      --  Raise Constraint_Error if out of range value. The reason for this
      --  explicit test is that we don't want junk values around, even if
      --  checks are off in the caller.
 
      if not To'Valid then
         raise Constraint_Error;
      end if;
 
      FIO.Check_File_Open (AP (File));
 
      if To = File.Line then
         return;
      end if;
 
      if Mode (File) >= Out_File then
         if File.Page_Length /= 0 and then To > File.Page_Length then
            raise Layout_Error;
         end if;
 
         if To < File.Line then
            New_Page (File);
         end if;
 
         while File.Line < To loop
            New_Line (File);
         end loop;
 
      else
         while To /= File.Line loop
            Skip_Line (File);
         end loop;
      end if;
   end Set_Line;
 
   procedure Set_Line (To : Positive_Count) is
   begin
      Set_Line (Current_Out, To);
   end Set_Line;
 
   ---------------------
   -- Set_Line_Length --
   ---------------------
 
   procedure Set_Line_Length (File : File_Type; To : Count) is
   begin
      --  Raise Constraint_Error if out of range value. The reason for this
      --  explicit test is that we don't want junk values around, even if
      --  checks are off in the caller.
 
      if not To'Valid then
         raise Constraint_Error;
      end if;
 
      FIO.Check_Write_Status (AP (File));
      File.Line_Length := To;
   end Set_Line_Length;
 
   procedure Set_Line_Length (To : Count) is
   begin
      Set_Line_Length (Current_Out, To);
   end Set_Line_Length;
 
   ----------------
   -- Set_Output --
   ----------------
 
   procedure Set_Output (File : File_Type) is
   begin
      FIO.Check_Write_Status (AP (File));
      Current_Out := File;
   end Set_Output;
 
   ---------------------
   -- Set_Page_Length --
   ---------------------
 
   procedure Set_Page_Length (File : File_Type; To : Count) is
   begin
      --  Raise Constraint_Error if out of range value. The reason for this
      --  explicit test is that we don't want junk values around, even if
      --  checks are off in the caller.
 
      if not To'Valid then
         raise Constraint_Error;
      end if;
 
      FIO.Check_Write_Status (AP (File));
      File.Page_Length := To;
   end Set_Page_Length;
 
   procedure Set_Page_Length (To : Count) is
   begin
      Set_Page_Length (Current_Out, To);
   end Set_Page_Length;
 
   --------------
   -- Set_WCEM --
   --------------
 
   procedure Set_WCEM (File : in out File_Type) is
      Start : Natural;
      Stop  : Natural;
 
   begin
      File.WC_Method := WCEM_Brackets;
      FIO.Form_Parameter (File.Form.all, "wcem", Start, Stop);
 
      if Start = 0 then
         File.WC_Method := WCEM_Brackets;
 
      else
         if Stop = Start then
            for J in WC_Encoding_Letters'Range loop
               if File.Form (Start) = WC_Encoding_Letters (J) then
                  File.WC_Method := J;
                  return;
               end if;
            end loop;
         end if;
 
         Close (File);
         raise Use_Error with "invalid WCEM form parameter";
      end if;
   end Set_WCEM;
 
   ---------------
   -- Skip_Line --
   ---------------
 
   procedure Skip_Line
     (File    : File_Type;
      Spacing : Positive_Count := 1)
   is
      ch : int;
 
   begin
      --  Raise Constraint_Error if out of range value. The reason for this
      --  explicit test is that we don't want junk values around, even if
      --  checks are off in the caller.
 
      if not Spacing'Valid then
         raise Constraint_Error;
      end if;
 
      FIO.Check_Read_Status (AP (File));
 
      for L in 1 .. Spacing loop
         if File.Before_LM then
            File.Before_LM := False;
 
            --  Note that if File.Before_LM_PM is currently set, we also have
            --  to reset it (because it makes sense for Before_LM_PM to be set
            --  only when Before_LM is also set). This is done later on in this
            --  subprogram, as soon as Before_LM_PM has been taken into account
            --  for the purpose of page and line counts.
 
         else
            ch := Getc (File);
 
            --  If at end of file now, then immediately raise End_Error. Note
            --  that we can never be positioned between a line mark and a page
            --  mark, so if we are at the end of file, we cannot logically be
            --  before the implicit page mark that is at the end of the file.
 
            --  For the same reason, we do not need an explicit check for a
            --  page mark. If there is a FF in the middle of a line, the file
            --  is not in canonical format and we do not care about the page
            --  numbers for files other than ones in canonical format.
 
            if ch = EOF then
               raise End_Error;
            end if;
 
            --  If not at end of file, then loop till we get to an LM or EOF.
            --  The latter case happens only in non-canonical files where the
            --  last line is not terminated by LM, but we don't want to blow
            --  up for such files, so we assume an implicit LM in this case.
 
            loop
               exit when ch = LM or else ch = EOF;
               ch := Getc (File);
            end loop;
         end if;
 
         --  We have got past a line mark, now, for a regular file only,
         --  see if a page mark immediately follows this line mark and
         --  if so, skip past the page mark as well. We do not do this
         --  for non-regular files, since it would cause an undesirable
         --  wait for an additional character.
 
         File.Col := 1;
         File.Line := File.Line + 1;
 
         if File.Before_LM_PM then
            File.Page := File.Page + 1;
            File.Line := 1;
            File.Before_LM_PM := False;
 
         elsif File.Is_Regular_File then
            ch := Getc (File);
 
            --  Page mark can be explicit, or implied at the end of the file
 
            if (ch = PM or else ch = EOF)
              and then File.Is_Regular_File
            then
               File.Page := File.Page + 1;
               File.Line := 1;
            else
               Ungetc (ch, File);
            end if;
         end if;
      end loop;
 
      File.Before_Upper_Half_Character := False;
   end Skip_Line;
 
   procedure Skip_Line (Spacing : Positive_Count := 1) is
   begin
      Skip_Line (Current_In, Spacing);
   end Skip_Line;
 
   ---------------
   -- Skip_Page --
   ---------------
 
   procedure Skip_Page (File : File_Type) is
      ch : int;
 
   begin
      FIO.Check_Read_Status (AP (File));
 
      --  If at page mark already, just skip it
 
      if File.Before_LM_PM then
         File.Before_LM := False;
         File.Before_LM_PM := False;
         File.Page := File.Page + 1;
         File.Line := 1;
         File.Col  := 1;
         return;
      end if;
 
      --  This is a bit tricky, if we are logically before an LM then
      --  it is not an error if we are at an end of file now, since we
      --  are not really at it.
 
      if File.Before_LM then
         File.Before_LM := False;
         File.Before_LM_PM := False;
         ch := Getc (File);
 
      --  Otherwise we do raise End_Error if we are at the end of file now
 
      else
         ch := Getc (File);
 
         if ch = EOF then
            raise End_Error;
         end if;
      end if;
 
      --  Now we can just rumble along to the next page mark, or to the
      --  end of file, if that comes first. The latter case happens when
      --  the page mark is implied at the end of file.
 
      loop
         exit when ch = EOF
           or else (ch = PM and then File.Is_Regular_File);
         ch := Getc (File);
      end loop;
 
      File.Page := File.Page + 1;
      File.Line := 1;
      File.Col  := 1;
      File.Before_Upper_Half_Character := False;
   end Skip_Page;
 
   procedure Skip_Page is
   begin
      Skip_Page (Current_In);
   end Skip_Page;
 
   --------------------
   -- Standard_Error --
   --------------------
 
   function Standard_Error return File_Type is
   begin
      return Standard_Err;
   end Standard_Error;
 
   function Standard_Error return File_Access is
   begin
      return Standard_Err'Access;
   end Standard_Error;
 
   --------------------
   -- Standard_Input --
   --------------------
 
   function Standard_Input return File_Type is
   begin
      return Standard_In;
   end Standard_Input;
 
   function Standard_Input return File_Access is
   begin
      return Standard_In'Access;
   end Standard_Input;
 
   ---------------------
   -- Standard_Output --
   ---------------------
 
   function Standard_Output return File_Type is
   begin
      return Standard_Out;
   end Standard_Output;
 
   function Standard_Output return File_Access is
   begin
      return Standard_Out'Access;
   end Standard_Output;
 
   --------------------
   -- Terminate_Line --
   --------------------
 
   procedure Terminate_Line (File : File_Type) is
   begin
      FIO.Check_File_Open (AP (File));
 
      --  For file other than In_File, test for needing to terminate last line
 
      if Mode (File) /= In_File then
 
         --  If not at start of line definition need new line
 
         if File.Col /= 1 then
            New_Line (File);
 
         --  For files other than standard error and standard output, we
         --  make sure that an empty file has a single line feed, so that
         --  it is properly formatted. We avoid this for the standard files
         --  because it is too much of a nuisance to have these odd line
         --  feeds when nothing has been written to the file.
 
         --  We also avoid this for files opened in append mode, in
         --  accordance with (RM A.8.2(10))
 
         elsif (File /= Standard_Err and then File /= Standard_Out)
           and then (File.Line = 1 and then File.Page = 1)
           and then Mode (File) = Out_File
         then
            New_Line (File);
         end if;
      end if;
   end Terminate_Line;
 
   ------------
   -- Ungetc --
   ------------
 
   procedure Ungetc (ch : int; File : File_Type) is
   begin
      if ch /= EOF then
         if ungetc (ch, File.Stream) = EOF then
            raise Device_Error;
         end if;
      end if;
   end Ungetc;
 
   -----------
   -- Write --
   -----------
 
   --  This is the primitive Stream Write routine, used when a Text_IO file
   --  is treated directly as a stream using Text_IO.Streams.Stream.
 
   procedure Write
     (File : in out Text_AFCB;
      Item : Stream_Element_Array)
   is
      pragma Warnings (Off, File);
      --  Because in this implementation we don't need IN OUT, we only read
 
      function Has_Translated_Characters return Boolean;
      --  return True if Item array contains a character which will be
      --  translated under the text file mode. There is only one such
      --  character under DOS based systems which is character 10.
 
      text_translation_required : Boolean;
      for text_translation_required'Size use Character'Size;
      pragma Import (C, text_translation_required,
                     "__gnat_text_translation_required");
 
      Siz : constant size_t := Item'Length;
 
      -------------------------------
      -- Has_Translated_Characters --
      -------------------------------
 
      function Has_Translated_Characters return Boolean is
      begin
         for K in Item'Range loop
            if Item (K) = 10 then
               return True;
            end if;
         end loop;
         return False;
      end Has_Translated_Characters;
 
      Needs_Binary_Write : constant Boolean :=
                             text_translation_required
                               and then Has_Translated_Characters;
 
   --  Start of processing for Write
 
   begin
      if File.Mode = FCB.In_File then
         raise Mode_Error;
      end if;
 
      --  Now we do the write. Since this is a text file, it is normally in
      --  text mode, but stream data must be written in binary mode, so we
      --  temporarily set binary mode for the write, resetting it after. This
      --  is done only if needed (i.e. there is some characters in Item which
      --  needs to be written using the binary mode).
      --  These calls have no effect in a system (like Unix) where there is
      --  no distinction between text and binary files.
 
      --  Since the character translation is done at the time the buffer is
      --  written (this is true under Windows) we first flush current buffer
      --  with text mode if needed.
 
      if Needs_Binary_Write then
         if fflush (File.Stream) = -1 then
            raise Device_Error;
         end if;
 
         set_binary_mode (fileno (File.Stream));
      end if;
 
      if fwrite (Item'Address, 1, Siz, File.Stream) /= Siz then
         raise Device_Error;
      end if;
 
      --  At this point we need to flush the buffer using the binary mode then
      --  we reset to text mode.
 
      if Needs_Binary_Write then
         if fflush (File.Stream) = -1 then
            raise Device_Error;
         end if;
 
         set_text_mode (fileno (File.Stream));
      end if;
   end Write;
 
begin
   --  Initialize Standard Files
 
   for J in WC_Encoding_Method loop
      if WC_Encoding = WC_Encoding_Letters (J) then
         Default_WCEM := J;
      end if;
   end loop;
 
   Initialize_Standard_Files;
 
   FIO.Chain_File (AP (Standard_In));
   FIO.Chain_File (AP (Standard_Out));
   FIO.Chain_File (AP (Standard_Err));
 
end Ada.Text_IO;
 

Compare with Previous | Blame | View Log

powered by: WebSVN 2.1.0

© copyright 1999-2024 OpenCores.org, equivalent to Oliscience, all rights reserved. OpenCores®, registered trademark.