OpenCores
URL https://opencores.org/ocsvn/or1k_old/or1k_old/trunk

Subversion Repositories or1k_old

[/] [or1k_old/] [trunk/] [ecos-2.0/] [doc/] [html/] [ref/] [redboot-commands-and-examples.html] - Rev 1782

Compare with Previous | Blame | View Log

<!-- Copyright (C) 2003 Red Hat, Inc.                                -->
<!-- This material may be distributed only subject to the terms      -->
<!-- and conditions set forth in the Open Publication License, v1.0  -->
<!-- or later (the latest version is presently available at          -->
<!-- http://www.opencontent.org/openpub/).                           -->
<!-- Distribution of the work or derivative of the work in any       -->
<!-- standard (paper) book form is prohibited unless prior           -->
<!-- permission is obtained from the copyright holder.               -->
<HTML
><HEAD
><TITLE
>RedBoot Commands and Examples</TITLE
><meta name="MSSmartTagsPreventParsing" content="TRUE">
<META
NAME="GENERATOR"
CONTENT="Modular DocBook HTML Stylesheet Version 1.76b+
"><LINK
REL="HOME"
TITLE="eCos Reference Manual"
HREF="ecos-ref.html"><LINK
REL="UP"
TITLE="RedBoot&#8482; User's Guide"
HREF="redboot.html"><LINK
REL="PREVIOUS"
TITLE="Configuring the RedBoot Environment"
HREF="configuring-the-redboot-environment.html"><LINK
REL="NEXT"
TITLE="Common Commands"
HREF="common-commands.html"></HEAD
><BODY
CLASS="CHAPTER"
BGCOLOR="#FFFFFF"
TEXT="#000000"
LINK="#0000FF"
VLINK="#840084"
ALINK="#0000FF"
><DIV
CLASS="NAVHEADER"
><TABLE
SUMMARY="Header navigation table"
WIDTH="100%"
BORDER="0"
CELLPADDING="0"
CELLSPACING="0"
><TR
><TH
COLSPAN="3"
ALIGN="center"
>eCos Reference Manual</TH
></TR
><TR
><TD
WIDTH="10%"
ALIGN="left"
VALIGN="bottom"
><A
HREF="configuring-the-redboot-environment.html"
ACCESSKEY="P"
>Prev</A
></TD
><TD
WIDTH="80%"
ALIGN="center"
VALIGN="bottom"
></TD
><TD
WIDTH="10%"
ALIGN="right"
VALIGN="bottom"
><A
HREF="common-commands.html"
ACCESSKEY="N"
>Next</A
></TD
></TR
></TABLE
><HR
ALIGN="LEFT"
WIDTH="100%"></DIV
><DIV
CLASS="CHAPTER"
><H1
><A
NAME="REDBOOT-COMMANDS-AND-EXAMPLES">Chapter 2. RedBoot Commands and Examples</H1
><DIV
CLASS="TOC"
><DL
><DT
><B
>Table of Contents</B
></DT
><DT
><A
HREF="redboot-commands-and-examples.html#AEN2850"
>Introduction</A
></DT
><DT
><A
HREF="common-commands.html"
>Common Commands</A
></DT
><DT
><A
HREF="flash-image-system.html"
>Flash Image System (FIS)</A
></DT
><DT
><A
HREF="persistent-state-flash.html"
>Persistent State Flash-based Configuration and Control</A
></DT
><DT
><A
HREF="executing-programs.html"
>Executing Programs from RedBoot</A
></DT
></DL
></DIV
><DIV
CLASS="SECT1"
><H1
CLASS="SECT1"
><A
NAME="AEN2850">Introduction</H1
><P
>RedBoot provides three basic classes of commands:    <P
></P
><UL
><LI
><P
>Program loading and execution</P
></LI
><LI
><P
>Flash image and configuration management</P
></LI
><LI
><P
>Miscellaneous commands</P
></LI
></UL
>Given the extensible and configurable nature of eCos and RedBoot,
there may be extended or enhanced sets of commands available.</P
><P
>The basic format for commands is:    <TABLE
BORDER="5"
BGCOLOR="#E0E0F0"
WIDTH="70%"
><TR
><TD
><PRE
CLASS="PROGRAMLISTING"
>RedBoot&#62; COMMAND [-S]... [-s val]... operand</PRE
></TD
></TR
></TABLE
></P
><P
>Commands may require additional information beyond the basic
command name. In most cases this additional information is optional, with
suitable default values provided if they are not present. 
 
      <DIV
CLASS="INFORMALTABLE"
><A
NAME="AEN2868"><P
></P
><TABLE
BORDER="1"
CLASS="CALSTABLE"
><THEAD
><TR
><TH
WIDTH="33%"
ALIGN="LEFT"
VALIGN="TOP"
>Format</TH
><TH
WIDTH="33%"
ALIGN="LEFT"
VALIGN="TOP"
>Description</TH
><TH
WIDTH="33%"
ALIGN="LEFT"
VALIGN="TOP"
>Example</TH
></TR
></THEAD
><TBODY
><TR
><TD
WIDTH="33%"
ALIGN="LEFT"
VALIGN="TOP"
>-S</TD
><TD
WIDTH="33%"
ALIGN="LEFT"
VALIGN="TOP"
>A boolean switch; the behavior of the command will differ, depending
on the presence of the switch.  In this example, the <TT
CLASS="USERINPUT"
><B
>-f</B
></TT
> switch
indicates that a complete initialization of the FIS data should be performed.
There may be many such switches available for any given command and any or all of
them may be present, in any order.</TD
><TD
WIDTH="33%"
ALIGN="LEFT"
VALIGN="TOP"
>                <TT
CLASS="COMPUTEROUTPUT"
> RedBoot&#62; <TT
CLASS="USERINPUT"
><B
>fis init -f</B
></TT
></TT
>
              </TD
></TR
><TR
><TD
WIDTH="33%"
ALIGN="LEFT"
VALIGN="TOP"
>-s<TT
CLASS="REPLACEABLE"
><I
> val</I
></TT
></TD
><TD
WIDTH="33%"
ALIGN="LEFT"
VALIGN="TOP"
>A qualified value; the letter "s" introduces the value, qualifying it's meaning.  In the
example, <TT
CLASS="USERINPUT"
><B
>-b 0x100000</B
></TT
> specifies where the memory dump should begin.
There may be many such switches available for any given command and any or all of
them may be present, in any order.</TD
><TD
WIDTH="33%"
ALIGN="LEFT"
VALIGN="TOP"
>                <TT
CLASS="COMPUTEROUTPUT"
> RedBoot&#62; <TT
CLASS="USERINPUT"
><B
>dump -b 0x100000 -l 0x20</B
></TT
></TT
>
              </TD
></TR
><TR
><TD
WIDTH="33%"
ALIGN="LEFT"
VALIGN="TOP"
><TT
CLASS="REPLACEABLE"
><I
> operand</I
></TT
></TD
><TD
WIDTH="33%"
ALIGN="LEFT"
VALIGN="TOP"
>A simple value; some commands require a single parameter for which an additional
<TT
CLASS="USERINPUT"
><B
>-X</B
></TT
> switch would be redundant.  In the example, <TT
CLASS="USERINPUT"
><B
>JFFS2</B
></TT
>
is the name of a flash image.  The image name is always required, thus is no need to qualify it with 
a switch.
Note that any un-qualified operand must always appear at the end of the command.</TD
><TD
WIDTH="33%"
ALIGN="LEFT"
VALIGN="TOP"
>                <TT
CLASS="COMPUTEROUTPUT"
> RedBoot&#62; <TT
CLASS="USERINPUT"
><B
>fis delete JFFS2</B
></TT
></TT
>
              </TD
></TR
></TBODY
></TABLE
><P
></P
></DIV
>&#13;</P
><P
>The list of available commands, and their syntax, can be obtained by
typing <B
CLASS="COMMAND"
>help</B
> at the command line:    
<TABLE
BORDER="5"
BGCOLOR="#E0E0F0"
WIDTH="70%"
><TR
><TD
><PRE
CLASS="SCREEN"
>RedBoot&#62; <TT
CLASS="USERINPUT"
><B
>help</B
></TT
>
Manage aliases kept in FLASH memory
      alias name [value]
Set/Query the system console baud rate
      baudrate [-b &lt;rate&#62;]
Manage machine caches
      cache [ON | OFF]
Display/switch console channel
      channel [-1|&lt;channel number&#62;]
Display disk partitions
      disks
Display (hex dump) a range of memory
      dump -b &lt;location&#62; [-l &lt;length&#62;] [-s]
Manage flash images
      fis {cmds}
Manage configuration kept in FLASH memory
      fconfig [-i] [-l] [-n] [-f] [-d] | [-d] nickname [value]
Execute code at a location
      go [-w &lt;timeout&#62;] [entry]
Help about help?
      help [&lt;topic&#62;]
Set/change IP addresses
      ip_address [-l &lt;local_ip_address&#62;] [-h &lt;server_address&#62;]
Load a file
      load [-r] [-v] [-d] [-c &lt;channel&#62;] [-h &lt;host&#62;] [-m {TFTP | HTTP | {x|y}MODEM | disk}]
      [-b &lt;base_address&#62;] &lt;file_name&#62;
Network connectivity test
      ping [-v] [-n &lt;count&#62;] [-t &lt;timeout&#62;] [-i &lt;IP_addr]
      -h &lt;host&#62;
Reset the system
      reset
Display RedBoot version information
      version
Display (hex dump) a range of memory
      x -b &lt;location&#62; [-l &lt;length&#62;] [-s]</PRE
></TD
></TR
></TABLE
></P
><P
>Commands can be abbreviated to their shortest
unique string. Thus in the list above, <B
CLASS="COMMAND"
>d,du,dum</B
>
and dump are all valid for the <B
CLASS="COMMAND"
>dump</B
> command. The <B
CLASS="COMMAND"
>fconfig</B
>
command can be abbreviated <B
CLASS="COMMAND"
>fc</B
>, but 
<B
CLASS="COMMAND"
>f</B
> would be ambiguous with <B
CLASS="COMMAND"
>fis</B
>.</P
><P
>There is one additional, special command. When RedBoot detects '$' or '+'
(unless escaped via '\') in a command, it switches to GDB protocol mode. At this
point, the eCos GDB stubs take over, allowing connections from a GDB host.
The only way to get back to RedBoot from GDB mode is to restart the platform.</P
><DIV
CLASS="NOTE"
><BLOCKQUOTE
CLASS="NOTE"
><P
><B
>NOTE: </B
>Multiple commands may be entered on a single line, separated by the semi-colon &#8220;;&#8221; character.</P
></BLOCKQUOTE
></DIV
><P
>The standard RedBoot command set is structured around the bootstrap
environment. These commands are designed to be simple to use and remember,
while still providing sufficient power and flexibility to be useful. No attempt
has been made to render RedBoot as the end-all product. As such, things such
as the debug environment are left to other modules, such as GDB stubs, which
are typically included in RedBoot. </P
><P
>The command set may be also be extended on a platform basis. </P
></DIV
></DIV
><DIV
CLASS="NAVFOOTER"
><HR
ALIGN="LEFT"
WIDTH="100%"><TABLE
SUMMARY="Footer navigation table"
WIDTH="100%"
BORDER="0"
CELLPADDING="0"
CELLSPACING="0"
><TR
><TD
WIDTH="33%"
ALIGN="left"
VALIGN="top"
><A
HREF="configuring-the-redboot-environment.html"
ACCESSKEY="P"
>Prev</A
></TD
><TD
WIDTH="34%"
ALIGN="center"
VALIGN="top"
><A
HREF="ecos-ref.html"
ACCESSKEY="H"
>Home</A
></TD
><TD
WIDTH="33%"
ALIGN="right"
VALIGN="top"
><A
HREF="common-commands.html"
ACCESSKEY="N"
>Next</A
></TD
></TR
><TR
><TD
WIDTH="33%"
ALIGN="left"
VALIGN="top"
>Configuring the RedBoot Environment</TD
><TD
WIDTH="34%"
ALIGN="center"
VALIGN="top"
><A
HREF="redboot.html"
ACCESSKEY="U"
>Up</A
></TD
><TD
WIDTH="33%"
ALIGN="right"
VALIGN="top"
>Common Commands</TD
></TR
></TABLE
></DIV
></BODY
></HTML
>

Compare with Previous | Blame | View Log

powered by: WebSVN 2.1.0

© copyright 1999-2024 OpenCores.org, equivalent to Oliscience, all rights reserved. OpenCores®, registered trademark.