OpenCores
URL https://opencores.org/ocsvn/yacc/yacc/trunk

Subversion Repositories yacc

[/] [yacc/] [trunk/] [syn/] [xilinx/] [s3_vsmpl.par] - Rev 2

Go to most recent revision | Compare with Previous | Blame | View Log

Release 7.1i par H.38
Copyright (c) 1995-2005 Xilinx, Inc.  All rights reserved.

ATHRON::  Wed Apr 13 22:25:08 2005

par -w -intstyle ise -ol std -t 1 s3_vsmpl_map.ncd s3_vsmpl.ncd s3_vsmpl.pcf 


Constraints file: s3_vsmpl.pcf.
Loading device for application Rf_Device from file '3s200.nph' in environment
E:/Xilinx7.1.
   "s3_vsmpl" is an NCD, version 3.1, device xc3s200, package ft256, speed -4

Initializing temperature to 85.000 Celsius. (default - Range: 0.000 to 85.000
Celsius)
Initializing voltage to 1.140 Volts. (default - Range: 1.140 to 1.260 Volts)


Device speed data version:  "PRODUCTION 1.35 2005-01-22".


Device Utilization Summary:

   Number of BUFGMUXs                  2 out of 8      25%
   Number of External IOBs           103 out of 173    59%
      Number of LOCed IOBs           103 out of 103   100%

   Number of MULT18X18s                2 out of 12     16%
   Number of RAMB16s                  11 out of 12     91%
   Number of Slices                 1918 out of 1920   99%
      Number of SLICEMs                1 out of 960     1%



Overall effort level (-ol):   Standard (set by user)
Placer effort level (-pl):    Standard (set by user)
Placer cost table entry (-t): 1
Router effort level (-rl):    Standard (set by user)

WARNING:Par:276 - The signal button<0>_IBUF has no load
WARNING:Par:276 - The signal button<1>_IBUF has no load
WARNING:Par:276 - The signal button<2>_IBUF has no load
WARNING:Par:276 - The signal PS2_DATA_IBUF has no load
WARNING:Par:276 - The signal PS2_CLK_IBUF has no load

Starting Placer

Phase 1.1
Phase 1.1 (Checksum:99018f) REAL time: 5 secs 

Phase 2.31
Phase 2.31 (Checksum:1312cfe) REAL time: 5 secs 

Phase 3.2
.


Phase 3.2 (Checksum:1c9c37d) REAL time: 6 secs 

Phase 4.8
..................................................
Phase 4.8 (Checksum:1108dd3) REAL time: 20 secs 

Phase 5.5
Phase 5.5 (Checksum:2faf07b) REAL time: 21 secs 

Phase 6.18
Phase 6.18 (Checksum:39386fa) REAL time: 29 secs 

Phase 7.5
Phase 7.5 (Checksum:42c1d79) REAL time: 29 secs 

Writing design to file s3_vsmpl.ncd


Total REAL time to Placer completion: 31 secs 
Total CPU time to Placer completion: 24 secs 

Starting Router

Phase 1: 13709 unrouted;       REAL time: 31 secs 

Phase 2: 12745 unrouted;       REAL time: 32 secs 

Phase 3: 11145 unrouted;       REAL time: 36 secs 

Phase 4: 0 unrouted;       REAL time: 3 mins 13 secs 


WARNING:CLK Net:clk25M<0>
may have excessive skew because 1 NON-CLK pins
failed to route using a CLK template.

Total REAL time to Router completion: 3 mins 13 secs 
Total CPU time to Router completion: 2 mins 57 secs 

Generating "PAR" statistics.

**************************
Generating Clock Report
**************************

+---------------------+--------------+------+------+------------+-------------+
|        Clock Net    |   Resource   |Locked|Fanout|Net Skew(ns)|Max Delay(ns)|
+---------------------+--------------+------+------+------------+-------------+
|           clk25M<0> |      BUFGMUX7| No   |  804 |  0.041     |  1.052      |
+---------------------+--------------+------+------+------------+-------------+
|           clk_BUFGP |      BUFGMUX0| No   |    3 |  0.040     |  1.050      |
+---------------------+--------------+------+------+------------+-------------+

INFO:Par:340 - 
   The Delay report will not be generated when running non-timing driven PAR
   with effort level Standard or Medium. If a delay report is required please do
   one of the following:  1) use effort level High, 2) use the following
   environment variable "XIL_PAR_GENERATE_DLY_REPORT", 3) create Timing
   constraints for the design.
Generating Pad Report.

All signals are completely routed.

Total REAL time to PAR completion: 3 mins 18 secs 
Total CPU time to PAR completion: 3 mins 

Peak Memory Usage:  104 MB

Placement: Completed - No errors found.
Routing: Completed - No errors found.

Number of error messages: 0
Number of warning messages: 5
Number of info messages: 1

Writing design to file s3_vsmpl.ncd



PAR done!

Go to most recent revision | Compare with Previous | Blame | View Log

powered by: WebSVN 2.1.0